Common Laboratory Equipment
Filter
Showing 4681–4710 of 4952 results
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER 158 |
| Configuration | 3-channel or 6-channel |
| Compliance | AOAC, ISO 1443, ISO 6497, EPA 907.1, APHA 2710B, UNI EN 14082 |
| Solvent Recovery Rate | >90% |
| Safety Certification | CE |
| Heating Control | PID-regulated electric heating elements with TEMS™ thermal energy management system |
| Sample Handling | Fully automated Randall extraction cycle with SafeEnd™ overheat protection and SolventXpress™ solvent delivery |
| Data Management | Onboard LCD touchscreen interface with audit-trail-capable result storage and GLP-compliant reporting |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER148 |
| Extraction Channels | 6 |
| Sample Capacity per Channel | 0.5–15 g |
| Reproducibility | ±1% |
| Solvent Volume Range | 30–100 mL |
| Solvent Recovery Rate | 50–75% |
| Temperature Control Range | 100–260 °C |
| Immersion Time | 0–999 min |
| Washing Time | 0–999 min |
| Power Consumption | 900 W |
| Net Weight | 40 kg |
| Brand | Vigor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | SPS |
| Pricing | Available Upon Request |
| Solvent Configurations | 3-, 5-, or 7-solvent modular units (customizable) |
| Purification Capacity per Unit | 800 L |
| Safety Integration | Compatible with flammable-solvent-rated safety cabinets |
| System Integration | Direct interface option with Vigor gloveboxes |
| Compliance Context | Designed for inert-atmosphere laboratory workflows requiring ultra-low H₂O/O₂ solvent handling (≤1 ppm H₂O, ≤1 ppm O₂ typical after regeneration) |
| Brand | Vigor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Vigor Single-Station Glove Box (Flexible Solar Cell Application) |
| Pricing | Available Upon Request |
| Brand | Vigor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Vigor Single-Station Vacuum Glove Box |
| Instrument Classification | Vacuum Glove Box |
| Filtration Class | ISO Class 2 (≤0.05 vol%/h leakage rate) |
| FFU Configuration | Integrated Fan + H14 HEPA Filter + Dual-Layer Perforated Floor + Rear Gas Return Duct |
| Airflow Pattern | Unidirectional Downward Flow (UDF) with Full-Volume Coverage via Top-Mounted Flow Distributor |
| Sealing System | Patented Multi-Point Dynamic Gasket Seal |
| Gas Purification | Integrated Catalytic Oxygen/H₂O Scrubbing Module (O₂ < 1 ppm, H₂O < 1 ppm after stabilization) |
| Control System | Embedded Industrial PLC with Touchscreen HMI, Real-Time Atmosphere Monitoring (O₂, H₂O, Pressure), and Audit-Trail-Enabled Logging |
| Brand | VMI |
|---|---|
| Origin | France |
| Model | Turbotest |
| Instrument Type | Probe-type Rotor-Stator Homogenizer |
| Power | 440 W DC |
| Speed Range | 50–3300 rpm |
| Processing Volume | 50–3300 mL (200 mL–20 L typical operational range) |
| Dimensions (W×D×H) | 998×447×430 mm |
| Max. Beaker Diameter | 300 mm |
| Max. Beaker Height | 300 mm |
| Safety Compliance | 2006/42/EC Machinery Directive |
| Construction | 316L Stainless Steel Shaft, ABS/PMMA Housing |
| Voltage | 100–240 V AC, 50/60 Hz |
| Interface Options | RS-232 or USB data logging port (optional) |
| Temperature Monitoring | Optional digital PT100 probe |
| Brand | VPI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SD-650MHG |
| Target Diameter | 2 inches |
| Vacuum System | High-vacuum compatible (≤5×10⁻⁶ Torr base pressure) |
| Integration Interface | Front-mounted flush-mount viewport with CF-40 or KF-40 vacuum flange |
| Sealing Standard | Metal-gasketed static seal compliant with ISO-KF and ISO-FM specifications |
| Power Supply | DC/RF configurable (optional upgrade) |
| Substrate Holder | Manual tilt-adjustable stage (max. Φ100 mm) |
| Brand | VPI (BoYuan Micro-Nano) |
|---|---|
| Origin | Beijing, China |
| Model | SD-900C |
| Sputtering Target Materials | Au, Ag, Pt, Cr, Al, Cu |
| Target Dimensions | Ø50 mm × 0.12 mm |
| Sputtering Voltage Range | 0–1600 V DC |
| Sputtering Current Range | 0–50 mA |
| Sputtering Time Control | 0–360 s |
| Carbon Evaporation Current | 0–100 A AC |
| Evaporation Voltage | 0–30 V AC |
| Evaporation Time | 0–1 s |
| Chamber Material | Borosilicate Glass |
| Chamber Dimensions | 160 mm × 110 mm (D × H) |
| Sample Stage Diameter Range | Ø50–70 mm |
| Sputtering Gases | Ar, N₂, O₂ |
| Vacuum System | VRD-8 Rotary Vane Pump (2 L/min) |
| Input Power | 220 V / 50 Hz (optional 110 V configuration) |
| Brand | VPI |
|---|---|
| Model | SD-980 |
| Type | Thermal Evaporation Coater |
| Origin | Beijing, China |
| Target Material | Carbon Fiber Rope |
| Target Diameter | 30 mm |
| Chamber Dimensions (W×D×H) | 340 × 390 × 300 mm |
| Sample Stage Diameter | 70 mm |
| Vacuum Chamber (D×H) | 160 × 110 mm (Borosilicate Glass) |
| Ultimate Vacuum | 5 Pa |
| Evaporation Current Range | 50–80 A |
| Pulse Count Setting | 0–9 pulses |
| Control Interface | Touchscreen HMI |
| Power Supply | 220 V AC, 50 Hz, Grounded |
| Pump | VRD-8 Rotary Vane Pump (2 L/min) |
| Weight | ~50 kg |
| Max. Power Consumption | 1.6 kW |
| Sputtering Gas Required | None |
| Brand | VWR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LX-120T2Z |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Range | Up to 12,000 rpm |
| Max RCF | 7,325 × g |
| Capacity | 8 × 1.5/2.0 mL tubes |
| Rotor Type | Fixed-Angle Rotor |
| Application Class | Cellular & Bacterial Separation |
| Dimensions (W×D×H) | 152 × 142 × 122 mm |
| Noise Level | ≤50 dB(A) |
| Motor Suspension | Floating Damping System |
| Display | OLED Screen |
| Safety Features | Auto Rotor Stop on Lid Opening, Liquid Leakage Detection, Over-Speed Protection |
| Brand | VWR |
|---|---|
| Origin | Shanghai, China |
| Model | LX-185T100R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 500–18,500 rpm |
| Max RCF | 30,130 × g |
| Max Capacity | 6 × 100 mL |
| Noise Level | ≤52 dB(A) |
| Dimensions (W×D×H) | 420 × 680 × 330 mm |
| Rotor Configuration | Horizontal (Swinging-Bucket) |
| Cooling Range | -20 °C to +40 °C |
| Chamber Material | 316 Stainless Steel |
| Display | 7-inch Capacitive Touchscreen (Glove-Compatible) |
| Vibration Amplitude | <0.02 mm |
| Door Lock | Auto-Suction Damping Lock |
| Features | Pre-cooling Function, Integrated Drain Channel, Triple-Damping System |
| Application Scope | Cell, Bacterial, Viral, Protein, Nucleic Acid, and Blood Component Separation |
| Brand | VWR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | 521-2845 |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Range | ≥6,000 rpm |
| Max RCF | 2,000 × g |
| Max Capacity | 8 × 1.5 mL microtubes |
| Dimensions (W×D×H) | 132 × 155 × 110 mm |
| Construction | Metal base, ABS housing, transparent polycarbonate safety lid |
| Compliance | CE, IEC 61010-1, UL 61010-1 |
| Brand | Wasserlab |
|---|---|
| Origin | Spain |
| Model | ULTRAMATIC PLUS |
| Output Water Grade | Type I (ASTM D1193-20, ISO 3696:1987 Class 1) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| TOC | <3 ppb |
| Endotoxin | <0.03 EU/mL |
| Bacterial Count | <1 CFU/mL |
| Flow Rate | 1.1 L/min |
| Feed Water Conductivity Limit | ≤20 µS/cm |
| Operating Pressure Range | 1–6 bar |
| Feed Water Temperature | ≤30 °C |
| Power Supply | 110–220 VAC, 50–60 Hz |
| Dimensions (H×W×D) | 60 × 36 × 49 cm |
| Weight | 35 kg |
| Terminal Filtration | 0.22 µm hydrophilic membrane |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Andrew+ Pipetting Robot |
| Pricing | Available Upon Request |
| Brand | Systec |
|---|---|
| Origin | USA |
| Model | 9000-1472 |
| Vacuum Level | ≤5 mTorr (typical) |
| Motor Type | Brushless DC Stepper Motor |
| Power Supply | 12–24 VDC, <15 W |
| Flow Path Materials | PTFE, FFKM, 316 Stainless Steel |
| Diaphragm Design | Continuously Purged Two-Stage Teflon |
| Compliance | CE, RoHS |
| Dimensions | 125 × 85 × 65 mm |
| Weight | 0.95 kg |
| Brand | -- |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Model | WaveDriver 200 |
| Price | Upon Request |
| Working Electrode Configuration | Single or dual WE with shared RE and CE |
| Current Range | ±100 nA to ±1 A |
| Potential Range | ±2.5 V / ±10 V / ±15 V (selectable) |
| EIS Frequency Range | 10 µHz – 1 MHz |
| DC Techniques | CV, LSV, CA, DPV, SWV, NPV, ASV, OCP, ZRA, RCP, BE, etc. |
| AC Techniques | EIS, Mott-Schottky, iR Compensation Measurement |
| Optional Accessories | RRDE, RDE, Spectroelectrochemical Cells |
| Software | AfterMath (EIS equivalent circuit fitting, Kramers–Kronig validation, data transformation, advanced analysis modules) |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | AP-WP Series |
| Power Supply | Rechargeable Li-ion Battery (Long Runtime) |
| Construction | Full 304 Stainless Steel |
| Cable Management | Fully Concealed |
| Surface Finish | Electropolished, Clean-in-Place (CIP)-Compatible |
| Load Capacity | 0–1000 kg (Configurable Range) |
| Readability Options | 0.01 kg, 0.02 kg, 0.05 kg, 0.1 kg, 0.2 kg, 0.5 kg |
| Footprint Customization | Length, Width, Height Fully Adjustable |
| Mobility | Integrated Heavy-Duty Casters with Locking Brakes & Removable Ramp |
| Sensor Configuration | Four High-Stability Shear-Beam Load Cells |
| Compliance | Designed to Support GMP/GLP Environments, Compatible with FDA 21 CFR Part 11 Data Integrity Requirements (via Optional Software Integration) |
| Brand | WEIYEE |
|---|---|
| Origin | Guangdong, China |
| Model | MP-2DA |
| Disc Diameter | 200 mm (8") |
| Number of Grinding/Polishing Plates | 2 |
| Rotational Speed Range (Plates) | 50–1500 rpm (infinitely variable + 6 preset speeds: 250/500/750/1000/1250/1500 rpm) |
| Plate Rotation Direction | Reversible (CW/CCW) |
| Pressure Control | Pneumatic single-point loading with adjustable pressure |
| Grinding/Polishing Head Speed | 20–120 rpm (infinitely variable) |
| Control Interface | 7-inch high-resolution capacitive touchscreen |
| Sample Capacity | Up to 6 specimens simultaneously |
| Liquid Delivery | Dual-channel intermittent dispensing system |
| Power Supply | 220 V AC, 50/60 Hz |
| Enclosure Material | Reinforced plastic-steel composite housing |
| Operating Modes | Fully automatic, semi-automatic, and manual |
| Brand | WEIYEE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SDJ-2 |
| Speed Range | 50–1500 rpm (infinitely variable) |
| Number of Grinding Belts | 2 |
| Belt Dimensions | 100 × 920 mm |
| Rotation | Bidirectional (forward/reverse) |
| Power Supply | 220 V AC |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Pump Type | Piston Vacuum Pump |
| Ultimate Vacuum | 80 mbar (60 mmHg) |
| Flow Rate | 38 L/min (2.3 m³/h, 50 Hz) |
| Exhaust Pressure | 100 PSI |
| Dimensions | 254 mm × 191 mm × 229 mm (W × D × H) |
| Weight | 6.3 kg |
| Inlet/Outlet Port | 1/4″ NPT (7 mm) |
| Power Supply | 230 V, 50 Hz |
| Display & Adjustable Vacuum Control | Yes |
| Lubrication | Oil-free, Dry-running Operation |
| Brand | Wener |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WenerLab V20 |
| Quotation | Upon Request |
| Deck Positions | 20 |
| Pipetting Accuracy | ≤5% at 1 μL |
| Pipetting Range | 0.5–1000 μL |
| Throughput Configurations | Single-channel, 8-channel, 16-channel |
| Dimensions (W×D×H) | 990 × 708 × 865 mm |
| Brand | Wener |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WenerLab V30 |
| Plate Positions | 30 |
| Pipetting Accuracy | CV ≤5% at 1 µL |
| Pipetting Range | 0.5–1000 µL |
| Sample Throughput | 96 samples per run |
| Dimensions | 1200 × 780 × 930 mm |
| Weight | 168 kg |
| Control System | External PC with Open API |
| Standard Tips | 96-channel (10 µL / 200 µL / 1000 µL) |
| Integrated Modules | Shaker, magnetic stand, PCR module, temperature controller, barcode scanner |
| Safety Features | Emergency stop button, optional UV lamp + HEPA filtration |
| Connectivity | Ethernet |
| Software Interface | Drag-and-drop graphical programming, real-time data logging, LIMS integration capability |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | 2755-25 |
| Configuration | Includes SL29GL-A glass cold trap, Dewar vessel, lid, exhaust tubing, and 25 L LN₂ storage tank |
| Compliance | Designed for cryogenic vacuum applications requiring stable condensation surface temperature and reproducible low-temperature operation |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | 2760-25 |
| Application | Cryogenic Sample Immersion & Thermal Contraction Testing |
| Includes | 25 L LN₂ Storage Dewar, Dual Temperature Sensors, Control Unit, Transfer Tubing, Vent Line, Two Sample Supports |
| Power Supply | 24 V DC |
| Valve Type | Solenoid Valve (24 V DC) |
| Sensor Principle | Cryogenic Temperature Threshold Detection |
| Compliance | Designed for GLP-aligned laboratory environments |
| Brand | WIGGENS |
|---|---|
| Origin | Shanghai, China |
| Model | A410 |
| Pump Type | Dual-Stage Diaphragm Pump |
| Ultimate Vacuum | ≤13 mbar |
| Flow Rate | ≤25 L/min |
| Motor Speed | 1450 rpm |
| Dimensions (W×D×H) | 230 × 155 × 173 mm |
| Weight | 4.5 kg |
| Rated Power | 95 W |
| Noise Level | 50 dB(A) |
| Power Supply | 220–240 V / 50 Hz |
| Inlet/Outlet Port | 10 mm ID |
| Protection | Thermal Overload Cut-Off |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Autoloop Pro |
| Sterilization Method | Flame-based (compatible with WIGGENS Fuego Bunsen burners) |
| Control System | Microprocessor-controlled with LED interface |
| Loop Capacity | 1–4 loops |
| Sterilization Time Range | 1–15 s (adjustable in 1-s increments) |
| Cooling Time Range | 1–45 s (adjustable in 1-s increments) |
| Auto-Shutdown | Yes (configurable: 15 min or 1 hr) |
| Rotation Direction | Bidirectional (left/right selectable) |
| Flame Intensity | Two preset levels |
| Status Indication | Dual-color LED (red = hot, green = cooled) |
| Construction | Stainless steel housing with heat-resistant tempered glass display cover |
| Dimensions (W×D×H) | 135 × 180 × 305 mm |
| Weight | 1200 g |
| Compliance | Designed for GLP-compliant microbiological workflows |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac 225 |
| Vacuum Level | ≥100 mbar |
| Flow Rate | ≤25 L/min |
| Weight | 4.3 kg |
| Dimensions (L×W×H) | 37 × 15 × 25 cm |
| Waste Bottle Capacity | 1000 mL (1 pc) |
| Filtration | 0.2 µm PTFE disc filter |
| Sterilization | Autoclavable (waste bottle & filter) |
| Foot Switch | Included |
| Accessories | 4 suction sets |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac 235 |
| Vacuum Level | ≥100 mbar |
| Flow Rate | ≤35 L/min |
| Weight | 6.9 kg |
| Dimensions (W×D×H) | 27 × 30 × 28 cm |
| Waste Bottle Capacity | 1500 mL × 2 |
| Filtration | 0.2 µm PTFE disc filter |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Foot Switch | Included |
| Accessories | 4-piece aspiration kit |
| Compliance | CE, ISO 13485-design aligned |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac 240 |
| Vacuum Level | ≥80 mbar |
| Flow Rate | ≤40 L/min |
| Foot Switch | Yes |
| Weight | 12 kg |
| Dimensions (L×W×H) | 54 × 26 × 35 cm |
| Waste Bottle Capacity | 3000 mL × 1 |
| Filtration | 0.2 µm PTFE disc filter |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Accessories Included | 4-piece aspiration kit |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac320A |
| Pump Flow Rate | 34 L/min |
| Ultimate Vacuum | ≤150 mbar |
| Waste Bottle Capacity | 3000 mL (PC) |
| Number of Filtration Ports | 3 |
| Filtration Plate Material | SS316 Stainless Steel |
| Filter Membrane Diameter | 47 mm / 50 mm |
| Filtration Flask Capacity | 300 mL |
| Effective Filtration Area per Port | 9.6 cm² |
| Hose Inner Diameter | 8 mm |
| Magnetic Flask Retention System | Yes |
| Sterilization Compatibility | Autoclave, Dry Heat, Flame |