Common Laboratory Equipment
Filter
Showing 6451–6480 of 18046 results
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HR/T16MM |
| Instrument Type | Benchtop High-Speed Refrigerated Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Function | Refrigerated Centrifugation |
| Configuration | Fixed-Angle Rotor |
| Max Capacity | 24 × 1.5 mL |
| Max Speed | 16,500 rpm |
| Max RCF | 22,500 × g |
| Dimensions (L×W×H) | 680 × 350 × 300 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp Control Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Certifications | CFDA Registered, ISO 9001:2015 & ISO 13485:2016 Certified |
| Rotor Material | Forged Aluminum Alloy |
| Rotor Compatibility | 0.2–2.0 mL tubes, PCR strip tubes |
| Display | TFT-LCD with Touch + Keypad Dual Interface |
| Safety Features | Biocontainment rotor seal (RoHS 2015/863 compliant), triple-damping suspension, automatic door lock, imbalance/over-speed/over-temp/under-voltage protection |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HR/T20M |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | General-Purpose Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Max Capacity | 4 × 100 mL |
| Max Speed | 20,000 rpm |
| Max RCF | 28,800 × g |
| Dimensions | 710 × 630 × 350 mm |
| Refrigeration System | Imported non-CFC compressor with R404a refrigerant |
| Temp Range | −20 °C to +40 °C |
| Temp Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 1.5 kW |
| Weight | 73 kg |
| Certifications | CFDA Registration & Manufacturing License, ISO 9001:2015, ISO 13485:2016 |
| Compliance | RoHS 2015/863 (silicone rubber rotor seals) |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | HR/T20MM |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor System |
| Maximum Capacity | 4 × 750 mL |
| Maximum Speed | 21,000 rpm |
| Maximum RCF | 31,750 × g |
| Dimensions (L×W×H) | 710 × 560 × 770 mm |
| Temperature Range | −20 °C to +40 °C |
| Temperature Accuracy | ±1 °C |
| Acceleration/Deceleration Rates | 10 programmable profiles |
| Preset Programs | 35 user-definable protocols |
| Rotor Autoidentification | Yes |
| Noise Level | ≤65 dB(A) |
| Power Supply | 2.0 kW |
| Timer Range | 0–99 h 59 min |
| Rotor Sterilization | Autoclavable at 121 °C (20 min) |
| Certifications | CE, ISO 13485, ISO 9001, IEC 61010-2-020 |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hettich HR20M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | 10,000–30,000 rpm (High-Speed) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Max Capacity | 6 × 500 mL |
| Max Speed | 20,000 rpm |
| Max RCF | 48,745 × g |
| Dimensions | 840 × 730 × 960 mm |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R404a (non-ozone-depleting, EPA SNAP-approved) |
| Control System | Mitsubishi PLC (compliant with EU EMC Directive 2014/30/EU & IEC 61131-2:2007), Weintek HMI (NEMA 4-rated, CE-certified) |
| Safety Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registration & Manufacturing License |
| Rotor Material | Aerospace-grade forged aluminum (angle rotors only) |
| Sealing | Integrated silicone O-ring (RoHS 2015/863 compliant) |
| Drive | High-torque AC frequency-controlled motor |
| Braking | 10-step programmable deceleration |
| Acceleration | 10-step programmable acceleration |
| Programs | 16 user-defined protocols |
| Data Display | Real-time curves for speed ramping, RCF integration, and temperature profiling |
| Structural Integrity | Triple-damping system, stainless-steel centrifuge chamber, three-layer steel safety housing, mechanical door interlock |
| Mobility | Dual-position casters with leveling feet |
| Brand | Hettich |
|---|---|
| Model | LR10M |
| Type | Floor-standing refrigerated centrifuge |
| Max. Capacity | 6 × 1000 mL |
| Max. Speed | 10,000 rpm |
| Max. RCF | 15,875 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Programmable Methods | 16 user-defined protocols |
| Dimensions (W×D×H) | 840 × 730 × 950 mm |
| Weight | 280 kg |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 5.7 kW |
| Noise Level | <65 dB(A) |
| Refrigerant | R404a (non-CFC) |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LR5M Mobile Blood Collection Vehicle Refrigerated Centrifuge |
| Instrument Type | Floor-standing Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2620 × g |
| Max Capacity | 12 × 5 mL (vacutainer & nucleic acid tubes) |
| Refrigeration System | R404a eco-friendly refrigerant with brushless DC compressor |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±2 °C |
| Speed Accuracy | ±50 rpm |
| Timer Range | 0 min – 99 h 59 min (continuous & short-spin modes) |
| Drive System | High-torque brushless DC motor with microprocessor control |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 0.6 kW |
| Net Weight | 52.5 kg |
| Dimensions (L×W×H) | 340 × 562 × 396 mm |
| Foot Design | Vacuum suction base for vehicle-mounted stability |
| Compliance | Designed for ISO 13485-aligned blood collection workflows |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Hettich LR6M |
| Instrument Type | Floor-standing Centrifuge |
| Speed Class | Low-speed Centrifuge (≤ 6,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Separation Level | Cell & Bacterial Pelletization |
| Max Capacity | 6 × 1000 mL |
| Max Speed | 4200 rpm |
| Max RCF | 5167 × g |
| Dimensions (W×D×H) | 840 × 730 × 950 mm |
| Weight | 270 kg |
| Power Supply | AC 220 V / 50 Hz |
| Total Power | 4.0 kW |
| Noise Level | <65 dB(A) |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Timer Range | 1 min – 99 h 59 min |
| Speed Accuracy | ±50 rpm |
| Acceleration/Deceleration | 10-step programmable |
| Programmable Methods | 16 user-defined protocols |
| Display | TFT-LCD color touchscreen with multilingual UI (EN/CN) |
| Safety Certifications | CFDA registration & manufacturing license, ISO 9001:2015, ISO 13485:2016 |
| Compliance | EU EMC Directive 2014/30/EU, IEC 61131-2:2007, NEMA 4-rated HMI, CE-marked electrical system |
| Refrigerant | R404a (non-CFC, ozone-friendly) |
| Rotor Locking | Mechanical interlocked lid |
| Chassis | AISI 304 stainless steel chamber, powder-coated steel housing, triple-layer reinforced front panel |
| Mobility | Integrated casters with leveling feet |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LR6M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Category | Low-Speed Centrifuge (≤6,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor |
| Separation Class | Cell & Bacterial Pelletization |
| Max Capacity | 6 × 1000 mL |
| Max Speed | 4200 rpm |
| Max RCF | 5167 × g |
| Dimensions | 840 × 730 × 950 mm |
| Weight | 270 kg |
| Power Supply | AC 220 V / 50 Hz |
| Total Power | 4.0 kW |
| Noise Level | <65 dB(A) |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Timer Range | 1 min – 99 h 59 min |
| Speed Accuracy | ±50 rpm |
| Refrigerant | R404a (non-CFC, ozone-friendly) |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA Registered & Certified |
| Control System | Mitsubishi PLC (IEC 61131-2:2007, EU EMC Directive 2014/30/EU), Weintek HMI (NEMA 4, CE certified) |
| Rotor Material | Austenitic 304 Stainless Steel Chamber |
| Safety | Mechanical door lock, triple-layer steel protection housing, imbalance detection, over-speed/over-temp/under-voltage/over-pressure alarms, auto-balance compensation, active vibration damping |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hettich LR8M |
| Instrument Type | Floor-standing Centrifuge |
| Speed Range | Up to 8,000 rpm |
| Rotor Configuration | Horizontal Swing-out Rotor (6 × 1000 mL) |
| Max Capacity | 6 × 1000 mL |
| Max RCF | 11,377 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Programmable Methods | 16 user-defined protocols |
| Drive System | High-torque AC frequency-controlled motor |
| Refrigeration | CFC-free R404a compressor system |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Dimensions (W×D×H) | 840 × 730 × 950 mm |
| Weight | 270 kg |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V / 50 Hz |
| Total Power Consumption | 4.0 kW |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | Mikro 185 |
| Instrument Type | Benchtop Centrifuge |
| Function | General-Purpose Microcentrifuge |
| Configuration | Fixed-Angle Rotor |
| Maximum Capacity | 24 × 1.5/2.0 mL |
| Maximum Speed | 14,000 rpm |
| Maximum RCF | 18,845 × g |
| Dimensions (H×W×D) | 261 × 353 × 238 mm |
| Weight | 11 kg |
| Power Supply | 200–240 V, 50–60 Hz |
| Power Consumption | 330 VA |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Timer Range | 1–99 min, ∞ (continuous), and short-spin mode |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | Mikro 185 |
| Centrifuge Type | Benchtop Microcentrifuge |
| Speed Range | Up to 14,000 min⁻¹ |
| Max RCF | 18,845 × g |
| Max Capacity | 24 × 1.5 / 2.0 mL tubes |
| Dimensions (W × D × H) | 228 × 262 × 352 mm |
| Rotor Options | 4 interchangeable rotors |
| Display | LCD with real-time RPM/RCF readout |
| Safety Features | Automatic imbalance shutdown, rotor auto-recognition, emergency lid release, instant centrifugation button |
| Compliance | IEC 61010-1, EN 61326-1, CE-marked for laboratory use |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | MIKRO 200 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 15,000 rpm |
| Max RCF | 21,382 × g |
| Max Capacity | 30 × 1.5/2.0 mL |
| Dimensions (H×W×D) | 260 × 275 × 344 mm |
| Weight | ~11.5 kg |
| Cooling | Ventilated (non-refrigerated) |
| Rotor Types | Fixed-angle rotors (24–30 position), including 24×2.0 mL (40°/45°), 30×2.0 mL (dual-row, 40°/52.5°), 20×2.0 mL cryotube rotor, and 4×0.2 mL PCR strip rotor |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | MIKRO 200R |
| Centrifuge Type | Benchtop Refrigerated Microcentrifuge |
| Max Speed | 15,000 rpm |
| Max RCF | 21,382 × g |
| Max Capacity | 30 × 1.5 mL / 2.0 mL tubes |
| Temperature Range | –10 °C to +40 °C (infinitely adjustable) |
| Dimensions (H×W×D) | 260 × 281 × 547 mm |
| Weight | 28 kg |
| Power Supply | 200–240 V, 50 Hz, 450 VA |
| Compliance | EN/IEC 61326-1 Class B |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | MIKRO 220 / MIKRO 220R |
| Type | Benchtop Centrifuge |
| Speed Range | 0–18,000 rpm |
| Max RCF | 31,514 × g |
| Max Capacity | 48 × 1.5 mL / 2.0 mL (angular rotor) or 60 × 1.5 mL / 2.0 mL (swing-bucket rotor) |
| Temperature Range (MIKRO 220R) | –20 °C to +40 °C |
| Dimensions (W × D × H) | 330 mm × 420 mm × 313 mm (MIKRO 220), 330 mm × 650 mm × 313 mm (MIKRO 220R) |
| Weight | 21 kg (MIKRO 220), 42 kg (MIKRO 220R) |
| Power Input | 200–240 V, 50–60 Hz |
| Compliance | EN/IEC 61326-1 Class B |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTANTA 460 / ROTANTA 460R |
| Type | Benchtop Centrifuge |
| Speed Range | 15,000 min⁻¹ |
| Max RCF | 24,400 × g |
| Max Capacity | 4 × 1000 mL |
| Dimensions (H×W×D) | ROTANTA 460: 456 × 554 × 706 mm |
| ROTANTA 460R | 456 × 770 × 706 mm |
| Weight | 101 kg / 141 kg |
| Power Supply | 200–240 V, 1~ |
| Power Consumption | 1000 VA (460) / 1800 VA (460R) |
| EMC Compliance | EN/IEC 61326-1 Class B |
| Timer Range | 1 sec – 99 h 59 min 59 sec + ∞ / pulse mode |
| Rotor Recognition | Automatic |
| Safety Features | Lid interlock with emergency release, imbalance detection & auto-shutdown, large transparent lid window, no external safety hood required |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTINA 380 / ROTINA 380R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 15,000 min⁻¹ |
| Max RCF | 24,400 × g |
| Max Capacity | 4 × 290 mL (swing bucket) |
| Temperature Range (ROTINA 380R only) | −20 °C to +40 °C |
| Dimensions (ROTINA 380) | 418 × 457 × 600 mm (H × W × D) |
| Dimensions (ROTINA 380R) | 260 × 281 × 547 mm (H × W × D) |
| Weight (ROTINA 380) | 58.5 kg |
| Weight (ROTINA 380R) | 88.5 kg |
| Power Supply | 200–240 V, 1~, 50–60 Hz |
| Power Consumption | 650 VA (ROTINA 380), 1300 VA (ROTINA 380R) |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Safety Compliance | IEC 61010-2-020, EN 61326-1 |
| Programmable Methods | 98 user-defined protocols |
| Rotor Recognition | Automatic |
| Unbalance Detection | Real-time electronic monitoring |
| Emergency Lid Release | Yes |
| Refrigeration | Compressor-based (ROTINA 380R only) |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTINA 380 |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Max Capacity (Horizontal Rotor) | 4 × 290 mL |
| Max Capacity (Fixed-Angle Rotor) | 6 × 94 mL or 30 × 2.0 mL |
| Max Speed | 15,000 rpm |
| Max RCF | 24,400 × g |
| Dimensions (H×W×D) | 418 × 457 × 600 mm |
| Weight | ~51 kg |
| Cooling Type | Ventilated (Non-refrigerated) |
| Rotor Compatibility | Fixed-angle, horizontal, slide, and drum rotors |
| Application Class | Biomolecular separation (nucleic acids, proteins, organelles) |
| Key Rotors | 30-place 2.0 mL fixed-angle rotor (Cat. No. 1789-A, 24,400 × g), 4-place 290 mL horizontal rotor (Cat. No. 1754, 4,863 × g), 6-place 94 mL fixed-angle rotor (Cat. No. 1792, 16,504 × g), 8-place microscope slide rotor (Cat. No. 1748, 2,415 × g) |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop Centrifuge |
| Rotor Configuration | Horizontal Swing-Out Rotor |
| Max Capacity | 4 × 600 mL |
| Max Speed | 15,000 rpm |
| Max RCF | 24,400 × g |
| Temperature Range | –20 °C to +40 °C (adjustable in 0.1 °C increments) |
| Dimensions (H×W×D) | 423 × 713 × 654 mm |
| Weight | 117 kg (ROTINA 420R) |
| Safety Compliance | EN/IEC 61326-1 Class B, EN 61010-1, IEC 61010-2-020 |
| Programmability | 99 user-defined protocols with recall function |
| Cooling | Active refrigeration with standby cooling |
| Rotor Recognition | Automatic detection via RFID or mechanical coding |
| Unbalance Protection | Real-time dynamic imbalance sensing and automatic shutdown |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTINA 420R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 100–15,000 min⁻¹ |
| Max RCF | 24,400 × g |
| Max Capacity | 4 × 600 mL |
| Temperature Range | –20 °C to +40 °C (adjustable in 0.1 °C increments) |
| Dimensions (W × D × H) | 713 × 654 × 423 mm |
| Weight | 117 kg |
| Power Supply | 200–240 V, 1~, 50–60 Hz |
| Max Power Consumption | 1600 VA |
| Safety Certifications | ISO 9001, ISO 13485/MDSAP, ISO 14001, EC Declaration of Conformity, Biosafety Lid Certificate (Zertifikat_1752) |
| Electromagnetic Compatibility | EN/IEC 61326-1 Class B |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTIXA 500 RS |
| Instrument Type | Floor-standing Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 11,500 rpm) |
| Max. Capacity | 4 × 1000 mL |
| Max. RCF | 18,038 × g |
| Dimensions (W×D×H) | 814 × 973 × 650 mm |
| Weight | 219 kg |
| Temperature Range | –20 °C to +40 °C (continuously adjustable) |
| Acceleration/Deceleration | Ultra-fast ramp profiles |
| Control Interface | RS232 port for PC connectivity (up to 29 units per host), 89 programmable protocols |
| Motor | Frequency-controlled brushless DC motor |
| Compliance | EN/IEC 61326-1 Class B (EMC), UVV-compliant maintenance design |
| Power Supply | 230–240 V, 50–60 Hz, 3800 VA |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTIXA 500 RS |
| Type | Floor-standing refrigerated centrifuge |
| Speed Range | Up to 10,000 rpm |
| Max RCF | 17,441 × g |
| Max Capacity | 4 × 1000 mL (horizontal rotor) |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (H×W×D) | 973 × 650 × 814 mm |
| Weight | ~172 kg |
| Rotor Compatibility | Multiple horizontal and angular rotors including 4×1000 mL (RCF 5,252), 6×250 mL (RCF 3,631), 2×microplate (RCF 2,652), ASTM bottle rotor (RCF 984), Schlenk bottle rotor (RCF 805) |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTIXA 500 RS |
| Type | Floor-standing Refrigerated Centrifuge |
| Max Speed | 11,500 rpm |
| Max RCF | 18,038 × g |
| Max Capacity | 4 × 1000 mL (horizontal rotor) |
| Temperature Range | −20 °C to +40 °C |
| Dimensions (W×D×H) | 650 × 814 × 973 mm |
| Weight | ~219 kg |
| Noise Level | 58 dB(A) |
| Power Supply | 230–240 V, 1~ |
| Power Consumption | 3,800 VA |
| EMC Compliance | EN/IEC 61326-1, Class B |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTO SILENTA 630 RS |
| Instrument Type | Floor-standing Centrifuge |
| Speed Range | 100–6,000 min⁻¹ |
| Max. RCF | 6,520 × g |
| Max. Capacity | 6 × 2,000 mL |
| Temperature Range | −20 °C to +40 °C |
| Dimensions (H×W×D) | 973 × 813 × 1015 mm |
| Weight | 355 kg |
| Power Supply | 400 V, 3~ + N, 50–60 Hz |
| Max. Power Consumption | 9,700 VA |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Programmable Methods | 89 stored protocols |
| Communication Interface | RS232 |
| Continuous Operation Mode | Yes |
| Rotor Auto-recognition | Yes |
| Safety Certifications | IEC 61010-2-020, EN 61326-1 |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTOFIX 32A |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–6000 rpm |
| Max RCF | 4226 × g |
| Max Capacity | 4 × 100 mL or 32 × 15 mL |
| Dimensions (H×W×D) | 257 × 366 × 430 mm |
| Weight | 23 kg |
| Power Supply | 208–240 V, 50–60 Hz |
| Power Consumption | 300 VA |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Timer Range | 1 s to 99 min 59 s, continuous mode (∞), and short-spin mode |
| Rotor Recognition | Automatic |
| Safety Features | Lid interlock, anti-slip lid latch, imbalance detection, emergency lid release |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop Centrifuge |
| Category | Low-Speed Centrifuge |
| Max. Speed | 4000 min⁻¹ (ROTOFIX 46) / 2000 min⁻¹ (ROTOFIX 46H) |
| Max. RCF | 3095 × g (ROTOFIX 46) / 984 × g (ROTOFIX 46H) |
| Max. Capacity | 4 × 290 mL (ROTOFIX 46) / 4 × 100 mL (ROTOFIX 46H) |
| Temperature Range (ROTOFIX 46H only) | +10 °C to +90 °C, continuously adjustable |
| Dimensions (H×W×D) | 345 × 538 × 647 mm |
| Weight | 60 kg |
| Power Supply | 200–240 V, 50–60 Hz |
| Power Consumption | 460 VA (ROTOFIX 46) / 600 VA (ROTOFIX 46H) |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Programmable Methods | 10 stored protocols |
| Acceleration/Deceleration | 9 selectable ramp levels |
| Safety Features | Automatic lid lock & emergency release, lid support mechanism, rotor auto-recognition, imbalance detection, motor & chamber overheat protection |
| Rotor Options | 4 interchangeable rotors available |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTOLAVIT II |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–3,500 rpm |
| Max RCF | 1,438 × g |
| Rotor Radius | 105 mm |
| Capacity | 24 × standard tubes (10 × 75 mm or 12 × 75 mm) |
| Timer Range | 1 sec – 9 min 59 sec |
| Dimensions (H×W×D) | 330 × 480 × 280 mm |
| Power Supply | 200–240 V AC, 50–60 Hz |
| Compliance | IEC 61010-1, EN 61326-1, CE-marked for in vitro diagnostic use |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Hettich TDL5M |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–5500 rpm |
| Max RCF | 4800 × g |
| Max Capacity | 4 × 500 mL |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤65 dB(A) |
| Dimensions (L×W×H) | 630 × 760 × 400 mm |
| Weight | 110 kg |
| Power Consumption | 1.8 kW |
| Timer Range | 1 min – 99 h 59 min |
| Drive System | High-torque AC brushless motor |
| Control Interface | TFT-LCD touchscreen + physical keys |
| Language Options | English, Chinese, Russian, Portuguese |
| Safety Certifications | CFDA Registered & Manufactured, ISO 9001:2015, ISO 13485:2016 |
| Rotor Compatibility | Horizontal swing-out rotors, bio-sealed angular rotors (RoHS 2015/863 compliant silicone gasket), PCR plates, microtiter plates, cell culture plates, deep-well plates |
| Cooling System | Imported CFC-free compressor with R404a refrigerant |
| Features | Pre-cooling, standby cooling, auto-defrost, imbalance detection, overspeed/overtemperature/under-voltage/over-voltage protection, triple-damping vibration isolation, electromechanical door lock |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TDL6M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Class | Low-Speed Centrifuge (max 6500 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Separation Target | Biological Macromolecules |
| Max Capacity | 4 × 500 mL |
| Max Speed | 6500 rpm |
| Max RCF | 4800 × g |
| Dimensions | 630 × 760 × 400 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp Control Accuracy | ±1 °C |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Motor | High-Torque Brushless Frequency-Controlled AC Motor |
| Drive & Control | Microprocessor-Based Digital Control System |
| Acceleration/Deceleration | 10 Adjustable Ramp Profiles |
| Programmable Protocols | 20 Predefined & User-Editable Methods |
| Display | 4.3-inch TFT True-Color Touchscreen with Dual Touch/Keypad Interface |
| Data Logging | Automatic Run Parameter Recording (Time, Speed, RCF, Temp, Rotor ID) |
| Rotor Recognition | Manual Input (No Auto-ID Sensor) |
| Construction | Full Steel Frame with Stainless Steel Centrifuge Chamber |
| Door Lock | Electromechanical Quiet-Lock System |
| Weight | 110 kg |
| Rated Power | 1.8 kW |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hettich TDL8M |
| Instrument Type | Benchtop Centrifuge |
| Speed Class | Low-Speed Centrifuge (up to 8,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Max Capacity | 4 × 500 mL |
| Max Speed | 8,000 rpm |
| Max RCF | 6,460 × g |
| Dimensions (L×W×H) | 630 × 760 × 400 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp. Control Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤65 dB(A) |
| Power Consumption | 1.8 kW |
| Weight | 110 kg |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registered & Manufactured |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TDZ6-WS |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–6000 rpm |
| Max RCF | 4800 × g |
| Max Capacity | 4 × 100 mL |
| Rotor Configuration | Horizontal Swing-Out |
| Application Class | Cell & Bacterial Separation |
| Drive System | Brushless Frequency-Controlled Motor |
| Control Interface | TFT Color Touchscreen + Digital Display |
| Acceleration/Deceleration Profiles | 10 selectable ramps |
| Stored Programs | 20 user-defined protocols |
| Timer Range | 0–99 h 59 min, continuous, or momentary spin |
| Power Consumption | 500 W |
| Noise Level | ≤65 dB(A) |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Electrical Supply | AC 220 V, 50 Hz |
| Rotor Recognition | Visual on-screen rotor diagram display |
| Safety Features | Automatic imbalance detection, motorized safety door lock, stainless steel chamber, multi-stage vibration damping system |