| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | DD5 Automated Cap-Removal Centrifuge |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 3020 ×g |
| Speed Accuracy | ±50 rpm |
| Capacity | 48 or 76 vacuum blood collection tubes (75 mm or 100 mm) |
| Temperature Control | Refrigerated (operating range: –20 °C to +40 °C) |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 630 × 500 × 420 mm |
| Weight | 50 kg |
| Certifications | CFDA Registration & Manufacturing License, ISO 9001:2015, ISO 13485:2016 |
| Compliance | Designed for IVD sample preparation per CLSI GP44-A4 and ISO 15189 pre-analytical requirements |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | DD5M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | Up to 4000 rpm |
| Max RCF | 3580 ×g |
| Capacity | 124–148 vacuum blood collection tubes (75 mm / 100 mm) |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤65 dB(A) |
| Dimensions (L×W×H) | 710×560×770 mm |
| Weight | 75 kg |
| Certifications | CFDA Registered & Manufactured, ISO 9001:2015, ISO 13485:2016 |
| Display | TFT-LCD with bilingual (EN/CN) interface |
| Drive System | High-torque AC/DC brushless inverter motor |
| Safety | Triple-damping suspension, imbalance detection, overspeed/overtemperature/under-voltage/over-voltage protection, 304 stainless steel rotor chamber, electro-mechanical auto-lock door |
| Brand | Hershey |
|---|---|
| Model | HR20M |
| Type | Floor-standing refrigerated high-speed centrifuge |
| Max. Speed | 20,000 rpm |
| Max. RCF | 48,745 × g |
| Max. Capacity | 4 × 1000 mL |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | <65 dB(A) |
| Dimensions (L×W×H) | 820 × 710 × 950 mm |
| Weight | 240 kg |
| Power Supply | AC 220 V / 50 Hz / 30 A |
| Total Power | 4.0 kW |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA registered, CE-compliant (EMC Directive 2014/30/EU, IEC 61131-2:2007), NEMA 4-rated HMI, RoHS 2015/863 |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | HR21M |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | 10,000–30,000 rpm (max 21,000 rpm) |
| Refrigerated | Yes |
| Configuration | Horizontal rotor compatible |
| Max Capacity | 4 × 1000 mL |
| Max RCF | 53,741 × g |
| Dimensions | 820 × 710 × 950 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Programs | 16 user-defined |
| Noise Level | ≤65 dB(A) |
| Power | 4.0 kW |
| Weight | 240 kg |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Safety | RoHS-compliant silicone sealing, NEMA4-rated HMI, CE/EMC (2014/30/EU), IEC 61131-2:2007, mechanical door lock, triple-damping suspension |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | HT12MM |
| Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 4000 rpm |
| Max RCF | 2200 ×g |
| Capacity | 12 tubes (standard configuration) |
| Rotor Options | SERO rotor (4000 rpm, 1842 ×g), HLS rotor (4200 rpm, 2200 ×g), Microgel Card rotor (4000 rpm, 1824 ×g) |
| Timer Range | 1 min – 99 h 59 min |
| Speed Accuracy | ±50 rpm |
| Drive System | High-torque brushless DC motor |
| Noise Level | ≤60 dB(A) |
| Dimensions | 550 × 440 × 330 mm |
| Weight | 35 kg |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 120 W |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | LR10M |
| Instrument Type | Floor-standing refrigerated centrifuge |
| Speed Range | 0–10,000 rpm |
| Max Capacity | 6 × 1000 mL |
| Max RCF | 15,875 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp Control Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Programmable Methods | 16 user-defined protocols |
| Display | TFT-LCD color touchscreen with multilingual UI (EN/CN) |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Power Supply | AC 220 V, 50 Hz |
| Noise Level | <65 dB(A) |
| Dimensions (L×W×H) | 840 × 730 × 950 mm |
| Weight | 280 kg |
| Refrigerant | R404a (non-CFC) |
| Drive System | AC brushless frequency-controlled motor |
| Safety | Mechanical door lock, 3-layer steel safety housing, imbalance/over-speed/over-temperature/under-voltage/over-voltage protection |
| Chamber Material | AISI 304 stainless steel |
| Certifications | CE (EMC Directive 2014/30/EU, IEC 61131-2:2007), NEMA 4-rated HMI |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LT7Y |
| Instrument Type | Floor-standing Centrifuge |
| Speed Class | Low-speed Centrifuge (≤5000 rpm) |
| Function | Standard Centrifuge for ASTM D95 / GB/T 6533-2012 Compliance |
| Configuration | Horizontal Swing-out Rotor |
| Maximum Capacity | 4 × 4 × 100 mL |
| Maximum Speed | 5000 rpm |
| Maximum RCF | 4500 × g |
| Dimensions (W×D×H) | 600 × 490 × 760 mm |
| Weight | 270 kg |
| Temperature Control Range | Ambient to 70 °C |
| Temperature Accuracy | ±2 °C |
| Speed Accuracy | ±50 rpm |
| Timer Range | 1 min – 99 h 59 min (continuous & short-spin modes) |
| Noise Level | ≤65 dB(A) |
| Drive System | High-torque AC/DC brushless frequency-converter motor with microprocessor control |
| Control Interface | Mitsubishi PLC (IEC 61131-2:2007, EMC Directive 2014/30/EU) + Weinview HMI (NEMA 4, CE certified) |
| Chamber Material | Austenitic 304 stainless steel |
| Safety | Triple-layer steel protective housing, automatic rotor imbalance detection, dual-damping suspension, interlocked motorized door lock (NEMA 4-rated), adjustable leveling feet with casters |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registration & Manufacturing License |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | TD5A |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 5500 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 250 mL |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Power Supply | AC 220 V, 50 Hz |
| Motor | Brushless AC Frequency-Controlled Motor |
| Control System | Microprocessor-Based with TFT Touchscreen Interface |
| Timer Range | 0–99 h 59 min / Continuous / Short-Term Mode |
| Programmable Methods | 20 User-Defined Protocols |
| Acceleration/Deceleration Profiles | 10 Adjustable Ramp Rates |
| Noise Level | ≤65 dB(A) |
| Chamber Material | Stainless Steel |
| Safety Features | Mechanical & Electronic Door Lock, Automatic Rotor Imbalance Detection, Multi-Stage Vibration Damping System |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | TD5T |
| Instrument Type | Benchtop Low-Speed Centrifuge |
| Rotor Configuration | Horizontal Swing-Out Rotor |
| Maximum Capacity | 4 × 250 mL |
| Maximum Speed | 5000 rpm |
| Maximum RCF | 4200 × g |
| Speed Accuracy | ±50 rpm |
| Temperature Control Range | Ambient +10°C to 70°C |
| Temperature Accuracy | ±2°C |
| Timer Range | 0–99 min |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 50 kg |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Drive System | Microprocessor-Controlled Brushless DC Frequency-Conversion Motor |
| Safety Features | Overspeed Protection, Imbalance Detection, Automatic Rotor Recognition, Electromechanical Door Lock, Dual-Damping Suspension System |
| Display Options | PLC LCD or LED Digital Display |
| Compliance | GB/T 6533–1986 (Determination of Water and Sediment in Crude Oil by Centrifuge Method) |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | TD6 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 6000 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 250 mL |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Power Supply | AC 220 V, 50 Hz |
| Noise Level | ≤60 dB(A) |
| Timer Range | 1 min – 99 h 59 min, continuous, or short-spin mode |
| Speed Accuracy | ±50 rpm |
| Drive System | High-torque brushless DC motor with microprocessor control |
| Certifications | CFDA registered, ISO 9001:2015 & ISO 13485:2016 certified |
| Safety Features | Triple-damping suspension, airtight biocontainment rotor seals (RoHS 2015/863 compliant), 304 stainless steel centrifuge chamber, reinforced steel housing with triple-layer protective casing |
| Control Interface | TFT-LCD true-color display with dual-mode operation (touch + physical keys), multilingual UI (English, Chinese, Russian, Portuguese), real-time parameter monitoring and on-the-fly adjustment |
| Programmability | 20 user-defined protocols, 10 acceleration/deceleration profiles |
| Rotor Compatibility | Fixed-angle rotors (aerospace-grade forged aluminum), swing-out rotors, microplate carriers (2 × 2 × 96-well), and polyamide fiber adapters for tubes from 0.2 mL to 250 mL |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | TDZ4 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 4000 rpm |
| Max RCF | 2600 ×g |
| Max Capacity | 24 × 10 mL |
| Acceleration/Deceleration | 10-step control |
| Display | TFT-LCD with touch + physical keys |
| Safety Certifications | CFDA Registered, ISO 9001:2015 & ISO 13485:2016 compliant |
| Compliance | RoHS 2015/863 (silicone O-ring seal) |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Weight (with rotor) | 20 kg |
| Dimensions (L×W×H) | 500 × 450 × 280 mm |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | TDZ4 |
| Centrifuge Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 4000 rpm |
| Max RCF | 2320 ×g |
| Max Capacity | 4 × 100 mL (or 12 × 20 mL / 18 × 10 mL / 24 × 10 mL) |
| Speed Accuracy | ±30 rpm |
| Timer Range | 0–99 h 59 min / Continuous / Short-Term Spin |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight (with rotor) | 20 kg |
| Dimensions (L×W×H) | 500 × 450 × 280 mm |
| Drive System | Brushless Frequency-Controlled Motor |
| Control Interface | TFT True-Color Touchscreen |
| Safety Features | Electromechanical Door Lock, Stainless Steel Chamber, Multi-Stage Damping System, Automatic Rotor Balance Detection |
| Programmability | 20 User-Defined Protocols |
| Construction | Full Steel Frame, Ergonomic Streamlined Housing |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | TDZ5 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 5000 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 100 mL |
| Rotor Configuration | Horizontal Swing-Out |
| Application Class | Biological Macromolecules |
| Drive System | Brushless AC Frequency-Controlled Motor |
| Display | TFT True-Color Touchscreen |
| Programmability | 20 Stored Protocols |
| Acceleration/Deceleration Profiles | 10 Adjustable Rates |
| Noise Level | ≤65 dB(A) |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 450 W |
| Timer Range | 0–99 h 59 min |
| Rotor Lock | Electromechanical Motor-Actuated Safety Lid Lock |
| Vibration Damping | Multi-Stage Passive Damping with Auto-Balancing Mechanism |
| Chamber Material | Stainless Steel (AISI 304) |
| Compliance | Designed for GLP-compliant routine laboratory use |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | TDZ5-WS |
| Instrument Type | Benchtop Centrifuge |
| Maximum Capacity | 4 × 100 mL |
| Maximum Speed | 5000 rpm |
| Maximum RCF | 4800 × g |
| Speed Accuracy | ±50 rpm |
| Timer Range | 0–99 h 59 min |
| Number of Presets | 20 |
| Drive System | AC Brushless Inverter Motor |
| Control System | Microprocessor-Based with TFT Touchscreen Display |
| Chamber Material | Stainless Steel (304) |
| Dimensions (L×W×H) | 500 × 450 × 280 mm |
| Weight | 25 kg |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 350 W |
| Acceleration/Deceleration Profiles | 10-step selectable |
| Rotor Types | Fixed-angle and Swing-out Configurations |
| Rotor Compatibility | 12 × 15 mL, 18 × 10 mL, 24 × 10 mL, 4 × 50 mL, 4 × 100 mL, 16 × 15 mL, 24 × 5 mL (vacutainer) |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | TL5R |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | Up to 5500 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 750 mL |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 710 × 560 × 770 mm |
| Weight | 150 kg |
| Drive System | AC Frequency-Controlled Motor |
| Control Interface | TFT-LCD Touchscreen + Physical Keys |
| Programmable Methods | 20 User-Defined Protocols |
| Acceleration/Deceleration | 10 Steps Each |
| Rotor Recognition | Automatic |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registered |
| Compliance | RoHS 2015/863 (Seal Material), GLP-Compatible Operation Log |
| Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | 3H12RI |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor |
| Maximum Capacity | 4 × 100 mL |
| Maximum Speed | 12,000 rpm |
| Maximum RCF | 13,220 × g |
| Dimensions (L×W×H) | 710 × 630 × 350 mm |
| Temperature Range | −20 °C to 40 °C |
| Temperature Accuracy | ±1 °C |
| Acceleration/Deceleration | 10 selectable rates |
| Programmable Methods | 100 stored protocols |
| Rotor Auto-Recognition | Yes |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 1.5 kW |
| Net Weight | 75 kg |
| Refrigerant | R404a (non-CFC) |
| Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | 3H16RI |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor |
| Max Capacity | 4 × 100 mL |
| Max Speed | 16,800 rpm |
| Max RCF | 20,320 × g |
| Dimensions | 710 × 630 × 350 mm |
| Temperature Range | −20 °C to 40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10 selectable rates |
| Rotor Recognition | Automatic |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Weight | 75 kg |
| Refrigerant | R404a |
| Display | 4.3″ TFT true-color touchscreen |
| Control System | dsPIC30F microcontroller with FAIRCHILD FSBB30CH motor driver |
| Safety Features | Overspeed, overtemperature, imbalance, triple-layer steel rotor chamber, active vibration damping, brushless frequency-controlled motor, electromagnetic door lock |
| Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | 3H16RI Benchtop High-Speed Refrigerated Centrifuge |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Cooling Function | Yes |
| Rotor Type | Fixed-Angle |
| Maximum Capacity | 4 × 100 mL |
| Max Speed | 16,800 rpm |
| Max RCF | 20,320 × g |
| Dimensions (L×W×H) | 710 × 630 × 350 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Noise Level | ≤60 dB(A) |
| Power Supply | 220 V, 50 Hz |
| Weight | 75 kg |
| Certifications | CFDA Registered & Licensed, ISO 9001:2015, ISO 13485:2016 |
| Compliance | RoHS 2015/863 (Seal Material) |
| Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | 3H20RI |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor |
| Maximum Capacity | 4 × 100 mL |
| Maximum Speed | 20,800 rpm |
| Maximum RCF | 31,150 × g |
| Dimensions | 710 × 630 × 350 mm |
| Temperature Range | −20 °C to +40 °C |
| Temperature Accuracy | ±1 °C |
| Acceleration/Deceleration Control | 10 selectable ramps |
| Noise Level | ≤60 dB(A) |
| Power Supply | 220 V, 50 Hz |
| Weight | 75 kg |
| Refrigerant | R404a (non-CFC) |
| Rotor Recognition | Automatic |
| Timer Range | 1 min – 99 h 59 min |
| Speed Accuracy | ±50 rpm |
| Total Power Consumption | 1.5 kW |
| [Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | 3H26RI |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Speed Range | 10,000–26,000 rpm (max 26,000 rpm) |
| Max RCF | 46,900 ×g |
| Max Capacity | 4 × 100 mL (swinging bucket rotor) |
| Temperature Range | –20 °C to +40 °C |
| Temp Control Accuracy | ±1 °C |
| Refrigerant | R404a |
| Noise Level | ≤65 dB(A) |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 710 × 630 × 350 mm |
| Weight | 75 kg |
| Rotor Options | Fixed-angle titanium rotors (12 × 1.5/2.0 mL, max 26,000 rpm / 46,900 ×g |
| Acceleration/Deceleration | 10 programmable rates |
| Run Programs | 100 user-defined protocols |
| Display | TFT color touch screen |
| Safety | Rotor imbalance detection, overspeed protection, overtemperature cutoff, triple-layer steel rotor chamber, automatic door lock, standby pre-cooling] |
| Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | HR/T16M |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Max Capacity | 4 × 100 mL |
| Max Speed | 16,000 rpm |
| Max RCF | 19,600 × g |
| Dimensions | 710 × 630 × 350 mm |
| Temperature Range | −20 °C to +40 °C |
| Temperature Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Weight | 73 kg |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registered |
| Brand | Herx |
|---|---|
| Model | xidi-HT12MM |
| Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 4000 rpm |
| Max RCF | 2200 ×g |
| Capacity | 12 × 15 mL tubes |
| Dimensions | 550 × 440 × 330 mm |
| Weight | 35 kg |
| Drive System | High-torque brushless DC motor |
| Control | Microprocessor-based with LCD touchscreen interface |
| Timer Range | 1 min – 99 h 59 min (continuous & short-spin modes) |
| Speed Accuracy | ±50 rpm |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 120 W |
| Rotor Types | SERO rotor (4000 rpm / 1842 ×g), HLS rotor (4200 rpm / 2200 ×g) |
| Safety Features | Automatic door interlock, imbalance detection, overspeed protection, self-diagnostic system, stainless steel chamber, multi-layer explosion-resistant construction |
| [Brand | Herx |
|---|---|
| Model | LR6M |
| Type | Floor-standing refrigerated centrifuge |
| Max. Capacity | 6 × 1000 mL |
| Max. Speed | 4200 rpm |
| Max. RCF | 5167 ×g |
| Temperature Range | –20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Programs Stored | 16 user-defined |
| Drive System | High-torque AC frequency-converter motor |
| Refrigeration | CFC-free R404a compressor system |
| Noise Level | <65 dB(A) |
| Dimensions (W×D×H) | 840 × 730 × 950 mm |
| Weight | 270 kg |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA registered] |
| [Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | LR8M |
| Type | Floor-Standing Refrigerated Centrifuge |
| Max Capacity | 4 × 150 mL (horizontal) / 6 × 1000 mL (horizontal) |
| Max Speed | 8,000 rpm |
| Max RCF | 11,377 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Programs Stored | 16 user-defined |
| Display | TFT-LCD touch interface with multilingual support (EN/CN) |
| Noise Level | <65 dB(A) |
| Dimensions (W×D×H) | 840 × 730 × 950 mm |
| Weight | 270 kg |
| Power Supply | AC 220 V / 50 Hz |
| Total Power | 4.0 kW |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Refrigerant | R404a (non-ozone-depleting) |
| Motor | High-torque AC frequency-controlled motor |
| Control System | Mitsubishi PLC (IEC 61131-2:2007 compliant), Weinview HMI (NEMA4, CE certified)] |
| Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | TDZ4 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2600 × g |
| Max Capacity | 12-slide carrier (TCT-specific cassette) |
| Rotor Type | Horizontal swing-out rotor for cytology cassettes |
| Speed Accuracy | ±50 rpm |
| Timer Range | 0–99 h 59 min |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 120 W |
| Dimensions (L×W×H) | 500 × 450 × 280 mm |
| Net Weight | 20 kg |
| Construction | 304 Stainless Steel chamber, full-steel powder-coated housing, triple-layer safety enclosure |
| Drive System | Brushless frequency-controlled motor |
| Control Interface | 4.3″ TFT true-color touchscreen with dual-keypad + touch control |
| Safety Features | Electronic door lock, overspeed protection, automatic imbalance detection & compensation, real-time fault alarm, rotor recognition (cassette-specific), GLP-compliant audit trail logging |
| [Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | TDD5 Debubbling Centrifuge |
| Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 500 mL |
| Timer Range | 1–99 min / Continuous / Short Spin |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Speed Accuracy | ±50 rpm |
| Motor | High-Torque Brushless AC Motor |
| Drive Control | Infineon Driver Module + EnRuiEn MCU |
| Display | TFT-LCD True Color Touchscreen with Dual Keypad Interface |
| Safety Certifications | CFDA Registered Device, ISO 9001:2015 & ISO 13485:2016 Certified |
| Compliance | Designed for GLP-compliant labs |
| Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | TDZ4 Dental & Oral Implant Medical Centrifuge |
| Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 4000 rpm |
| Max RCF | 2600 ×g |
| Max Capacity | 24 × 10 mL |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤60 dB(A) |
| Dimensions (L×W×H) | 500×450×280 mm |
| Weight (with rotor) | 20 kg |
| Power Supply | AC 220 V, 50 Hz |
| Motor | High-torque brushless DC motor |
| Control System | Microprocessor-based with TFT-LCD touchscreen + physical keys |
| Certifications | CFDA registered, ISO 13485:2016 & ISO 9001:2015 compliant |
| Safety | RoHS-compliant silicone sealing gasket, 304 stainless steel centrifuge chamber, triple-layer steel protection housing, auto-locking lid mechanism |
| Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | General Distributor |
| Product Category | Domestic |
| Model | TDZ4 |
| Instrument Type | Benchtop Centrifuge |
| Speed Class | Low-Speed Centrifuge (≤4000 rpm) |
| Function | Standard Centrifuge |
| Configuration | Fixed-Angle Rotor |
| Application Grade | Cell/Bacterial Separation |
| Maximum Capacity | 12 Slides |
| Max. Speed | 4000 rpm |
| Max. RCF | 2600 × g |
| Dimensions | 500 × 450 × 280 mm |
| Weight | 20 kg |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 120 W |
| Noise Level | ≤60 dB(A) |
| Timer Range | 0–99 h 59 min |
| Speed Accuracy | ±50 rpm |
| Rotor Type | 12-Position Slide Carrier Rotor |
| Display | 4.3″ TFT True-Color Touchscreen |
| Control System | Microprocessor-Based Dual-Mode (Touch + Keypad) |
| Motor | Brushless Frequency-Controlled DC Motor |
| Chamber Material | AISI 304 Stainless Steel |
| Safety Features | Electronic Lid Lock, Imbalance Detection, Overspeed Protection, Automatic Rotor Recognition, Real-Time Fault Alert |
| Language Support | English, Chinese, Russian, Portuguese |
| Program Storage | 20 User-Defined Protocols |
| Brand | Herx |
|---|---|
| Model | TGL20MW |
| Type | Benchtop Refrigerated Centrifuge |
| Max Capacity | 6 × 250 mL |
| Max Speed | 20,600 rpm |
| Max RCF | 30,550 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp Control Accuracy | ±1 °C |
| Noise Level | ≤60 dB(A) |
| Dimensions (W×D×H) | 630 × 760 × 400 mm |
| Weight | 110 kg |
| Power | 1.8 kW |
| Acceleration/Deceleration | 10 selectable rates |
| Programmable Methods | 20 pre-set + user-defined protocols |
| Rotor Recognition | Automatic |
| Drive System | Brushless AC frequency-conversion motor with dsPIC30F microcontroller and FSBB30CH intelligent driver module |
| Cooling System | Eco-friendly R404a refrigerant compressor unit |
| Safety Features | Overspeed, overtemperature, imbalance, door interlock, and active vibration damping |
| Brand | Herx |
|---|---|
| Model | TL5R |
| Type | Floor-standing Refrigerated Centrifuge |
| Max Speed | 4000 rpm |
| Max RCF | 3580 ×g |
| Max Capacity | 148 × 5 mL tubes |
| Temperature Range | -20°C to +40°C |
| Refrigerant | R404a (CFC-free) |
| Drive System | Brushless AC/DC Inverter Motor |
| Control Interface | TFT True-color Touchscreen Display |
| Acceleration/Deceleration Profiles | 10 selectable ramps |
| Programmable Protocols | 20 stored methods |
| Timer Range | 1 min – 99 h 59 min |
| Speed Accuracy | ±50 rpm |
| Temp. Stability | ±1°C |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 710×560×770 mm |
| Weight | 150 kg |
| Compliance | CE, ISO 13485 (manufacturing), IEC 61010-1 |