Common Laboratory Equipment
Filter
Showing 811–840 of 4952 results
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AbioCutter™ Series Aseptic Tube Disconnecting Pliers |
| Pricing | Upon Request |
| Design Variant | ACS-A100 (Standard Duty) & ACS-M100 (Compact Duty) |
| Tube Compatibility | ACS-A100: 1/4"–3/4" (6.4–19.1 mm) ID TPE/silicone tubing |
| ACS-M100 | 1/8"×1/4" (3.2×6.4 mm) flat-profile TPE tubing |
| Power Source | Rechargeable Lithium-Ion Battery |
| Operational Cycles per Charge | >100 cycles |
| Blade Material | Corrosion-Resistant Hardened Steel with Surface Passivation |
| Blade Mounting | Interchangeable Tongue-and-Groove (Dovetail) Interface |
| Safety Mechanism | Manual Mechanical Pressure Relief Lever |
| Compliance | Designed for ISO 13485-certified manufacturing environments |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Support Tray for 2D Fluid Bags |
| Pricing | Upon Request |
| Material Options | 316L Stainless Steel |
| Customizable Tilt Angle | Yes |
| Cleanability | Autoclavable / CIP-Compatible |
| Compliance | Designed for ISO 13485-aligned bioprocessing environments |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Stainless Steel Multi-Tier Transfer Trolley / Hanging Rack |
| Pricing | Available Upon Request |
| Material | AISI 304 Stainless Steel |
| Customization | Fully Configurable (Dimensions, Tier Count, Hook Type, Casters, Braking Options) |
| Compliance | Designed for ISO 13485-aligned cleanroom-adjacent environments and GMP-compliant manufacturing support |
| Brand | APTUM |
|---|---|
| Origin | United Kingdom |
| Model | 2100 |
| Bath Capacity | 9 L |
| Temperature Range | Ambient to 110 °C |
| Temperature Stability | ±0.2 °C |
| Chamber Dimensions (D×H) | 210 × 230 mm |
| Overall Height | 335 mm |
| Width | 340 mm |
| Depth | 228 mm |
| Net Weight | 4.5 kg |
| Max Load Weight | 3.0 kg |
| Max Fault Temperature | 133.3 °C |
| Power Supply | 220 V |
| Chamber Configuration | Single-unit steam chamber with modular slide racks (3-chamber kit available separately) |
| Brand | APV |
|---|---|
| Origin | Germany |
| Model | APV-15MR |
| Instrument Type | High-Pressure Homogenizer |
| Max Operating Pressure | 690 bar (10,000 psi) |
| Adjustable Pressure Range | 0–690 bar (manual handwheel control) |
| Flow Rate | 57 L/h |
| Sample Inlet Particle Size Limit | ≤500 µm |
| Power Supply | 380 V / 50 Hz |
| Motor Power | 2.2 kW (3 hp) |
| Dimensions (W×D×H) | 914 × 610 × 965 mm |
| Weight | 159 kg |
| Drive Mechanism | Gear-driven (not belt-driven) |
| Brand | APV |
|---|---|
| Origin | Germany |
| Type | High-Pressure Laboratory Homogenizer |
| Model | 2000–2 |
| Max. Operating Pressure | 2000 bar |
| Adjustable Pressure Range | 0–2000 bar (manual handwheel) |
| Flow Rate | 11 L/h |
| Valve Material | Zirconia Ceramic Alloy (SEO ceramic valve) |
| Max. Inlet Particle Size | ≤500 µm |
| Operating Temperature Range | Ambient to 100 °C |
| Power Supply | 380 V / 50 Hz |
| Power Consumption | 3 kW |
| Dimensions (W×H×L) | 370 × 620 × 818 mm |
| Weight | 105 kg |
| Noise Level | 50 dB(A) |
| Brand | APV |
|---|---|
| Origin | Germany |
| Model | APV-31MR |
| Instrument Type | High-Pressure Homogenizer |
| Max Operating Pressure | 240 bar (3,500 psi) |
| Adjustable Pressure Range | 0–240 bar |
| Flow Rate | 117 L/h |
| Sample Inlet Particle Size Limit | ≤500 µm |
| Power Supply | 380 V / 50 Hz |
| Motor Power | 2.2 kW (3 hp) |
| Dimensions (W×D×H) | 914 × 610 × 965 mm |
| Weight | 159 kg |
| Drive Mechanism | Gear-Driven |
| Brand | APV |
|---|---|
| Origin | Germany |
| Model | APV-1000, APV-2000 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×H×L) | 370 × 620 × 818 mm |
| Throughput | 22 L/h (APV-2000), 11 L/h (APV-1000) |
| Valve Material | Ceramic |
| Plunger Material | Solid Ceramic |
| Pump Head Material | Duplex Stainless Steel |
| Pressure Regulation | Manual Handwheel |
| Secondary Homogenization | Optional |
| Safety Features | Overpressure Alarm, Thermal Monitoring, Emergency Stop, Current-Limiting Protection |
| Brand | APV |
|---|---|
| Origin | Germany |
| Model | APV-1000 |
| Instrument Type | High-Pressure Homogenizer |
| Maximum Operating Pressure | 1000 bar |
| Flow Rate | 22 L/h |
| Pressure Adjustment | Manual (handwheel), continuous 0–1000 bar |
| Homogenization Valve | Dual-stage SEO ceramic valve (zirconia-toughened ceramic alloy) |
| Inlet Particle Size Limit | ≤500 µm |
| Operating Temperature Range | Ambient to 100 °C |
| Power Supply | 380 V / 50 Hz |
| Power Consumption | 3 kW |
| Noise Level | 50 dB(A) |
| Dimensions (W×H×L) | 370 × 620 × 818 mm |
| Weight | 105 kg |
| Cooling & Lubrication | Integrated plunger cooling and lubrication system |
| Display | Digital pressure and temperature readout with overpressure alarm |
| Compliance | Designed for GLP-compliant R&D environments |
| Brand | APV |
|---|---|
| Origin | Germany |
| Model | APV-2000 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 370 × 620 × 818 mm |
| Processing Capacity | 11 L/h |
| Fluid End Materials | Duplex Stainless Steel Compression Head, Ceramic Plunger, Cobalt Alloy PVB Valves with Tungsten Carbide Seats |
| Control Interface | Digital Pressure & Temperature Display, Overpressure Alarm, Emergency Stop, Integrated Current-Limiting Safety Circuit |
| Housing | Polished Stainless Steel, CIP/SIP-Compatible, Modular Frame Design |
| Brand | APV |
|---|---|
| Origin | Germany |
| Model | APV-2000 |
| Maximum Operating Pressure | 2000 bar |
| Adjustable Pressure Range | 0–2000 bar |
| Flow Rate | 11 L/h |
| Homogenization Valve Type | SEO Zirconia Ceramic Valve |
| Valve Material | Zirconia Ceramic Alloy |
| Cooling & Lubrication System | Integrated Water-Cooled Plunger System |
| Temperature Monitoring | Digital Display (Pressure + Sample Temperature) |
| Overpressure Alarm | Yes |
| Max Feed Particle Size | ≤500 µm |
| Operating Temperature Range | Up to 100 °C |
| Power Supply | 380 V / 50 Hz |
| Power Consumption | 3 kW |
| Noise Level | 50 dB(A) |
| Dimensions (W×H×L) | 370 × 620 × 818 mm |
| Weight | 105 kg |
| CIP/SIP Capable | Yes |
| Compliance | CE, ISO 9001 |
| Brand | Aquapro |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TR Series |
| Quotation | Upon Request |
| Purified Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | ≤0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin Level | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| RO Production Rate (25 °C) | 5/10/20 L/h |
| Dispensing Accuracy | ±5 mL (≤500 mL), ±1.5% (>500 mL) |
| Flow Rate | ≤2 L/min |
| Dimensions (H×W×D) | 540×380×480 mm |
| Weight | 40 kg |
| Feed Water Conductivity | <1000 µS/cm |
| Feed Pressure | 1–5 kgf/cm² |
| Feed Temperature | 5–35 °C |
| Chlorine | <1 ppm |
| pH | 6.5–8.5 |
| Hardness (as CaCO₃) | <450 ppm |
| Input Power | 100–240 VAC, 50–60 Hz |
| Max Power Consumption | 221 W |
| Acoustic Noise | <50 dB(A) |
| Brand | Argos Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 04397-34 |
| Price | Upon Request |
| Rotation Speed | 18 rpm (fixed analog) |
| Operating Temperature Range | 4–60 °C |
| Relative Humidity Range | 20–80 % RH |
| Tube Capacity | 0.5–50 mL |
| Adjustable Tilt Angle per Panel | 0–90° |
| Number of Mixing Panels | 4 |
| Tube Rack Compatibility | 42 × 0.5–0.8 mL |
| Rack Installation | Tool-free, quick-release mechanism |
| Direction Reversal | Tap-activated polarity switch |
| Environmental Rating | Suitable for cold rooms and incubators |
| Brand | Argos Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CELLspin |
| Pricing | Upon Request |
| Brand | Argos Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | E-Vac Vacuum Aspiration System |
| Pricing | Available Upon Request |
| Brand | Argos Technologies |
|---|---|
| Origin | USA |
| Power Supply | 220 VAC, Europe Plug |
| Rotor Configurations | 8-place fixed-angle rotor (1.5 mL tubes) |
| Operation Modes | Continuous, Pulse, Timer (1–15 min) |
| Safety | Automatic rotor stop upon lid release |
| Visual Indicator | User-selectable RGB LED ring (red/green/blue/off) with transparent lid visibility |
| Brand | Argos Technologies |
|---|---|
| Origin | USA |
| Model | RotoFlex |
| Voltage Options | 120 V (22 rpm) / 240 V (18 rpm) |
| Rotation Speed | Fixed-speed (RotoFlex) or Adjustable 10–40 rpm (RotoFlex Plus) |
| Speed Resolution | 1 rpm (Plus model) |
| Rotation Angle | 0° to 90° adjustable per panel |
| Panel Configuration | 4 independent mixing panels |
| Tube Capacity | 0.5 mL to 50 mL |
| Rotation Mode | Continuous unidirectional, reversible, or oscillatory (Plus only) |
| Motion Type | 360° end-over-end tumbling |
| Power Input | Standard AC |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Arium® Smart Station |
| Configuration | Benchtop or Wall-Mounted |
| Dispensing Range | 0.1 mL to 5 L |
| Dispensing Modes | Continuous, Drop-by-Drop, Soft Start/Stop |
| Arm Adjustment | Height-adjustable (infinitely variable), 360° rotation |
| Interface | Full-color capacitive touchscreen |
| Fluid Path Materials | Pharmaceutical-grade PEEK, EPDM, and PTFE |
| Compliance | Designed for ISO 3696 Grade 1 & ASTM D1193 Type I water distribution |
| Certification | CE-marked, compliant with EU Medical Device Regulation (MDR) Annex I essential requirements for ancillary equipment |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | CP-4 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Control Range | 12–32 °C |
| Temperature Stability | ±0.1 °C |
| Refrigeration Capacity | 3.9 kW |
| Circulation Pump Pressure | 2.0 bar |
| Circulation Flow Rate | 6.3 L/min |
| Reservoir Volume | 1 L |
| Operating Mode | Continuous |
| Power Supply | 200–230 V, 50/60 Hz |
| Ambient Operating Temperature | 12–32 °C |
| Storage Temperature | −20 to +60 °C |
| Water Flow Connection | 3/8″ compression fitting |
| Airflow Requirement | 19.8 m³/min (700 SCFM) |
| Dimensions (L×W×H) | 483 × 533 × 617 mm |
| Net Weight | 36 kg (compressor unit), 39 kg (fully assembled) |
| Water Quality | pH 6–8, total hardness < 85 ppm CaCO₃ |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | DE-210 |
| Cooling Capacity | 1 W at 4.2 K (with optional 4K cold head) / 4 W at 10 K (with optional 10K cold head) |
| Vibration Level | < 5 µm peak-to-peak (typical, at cold head flange) |
| Operating Noise | < 65 dB(A) at 1 m |
| Helium Circuit | Closed-cycle, helium-recirculating |
| Compressor | ARS-10HW, air-cooled, oil-lubricated |
| Cold Head | DE-210AF, Gifford-McMahon type |
| Flexible Transfer Lines | Two 3-m helium gas lines (stainless steel braided, vacuum-jacketed) |
| Minimum Base Temperature | ≤ 4.2 K (with 4K cold head) |
| Typical Cool-down Time | < 3.5 hours to 4.2 K from 300 K |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | DE-215 |
| Cooling Capacity | 1.5 W at 4.2 K |
| Cold Head Type | Two-Stage Gifford-McMahon Cryocooler |
| Operating Environment | Closed-Cycle, Helium-Gas-Driven |
| Flange Options | MRI Universal Flange, ISO-KF Flange |
| Standard Configuration | DE-215S Cold Head + ARS-10HW Compressor + Two Flexible High-Pressure Helium Transfer Lines |
| Vibration Level | < 5 µm peak-to-peak (at cold tip, 4.2 K) |
| Acoustic Noise | < 65 dB(A) at 1 m |
| Maintenance Interval | ≥ 15,000 hours compressor runtime |
| Compliance | CE-marked, RoHS-compliant, UL-listed components |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | DE204 |
| Cooling Capacity | 2.5 W @ 20 K (standard configuration) |
| Base Temperature | ≤4.2 K (with optional 4K cold head) |
| Cold Head | DE-204AF |
| Compressor | ARS-4HW |
| Helium Transfer Lines | Two flexible high-pressure lines |
| Compliance | CE, RoHS, UL-listed components |
| Operating Noise Level | <65 dB(A) |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | DS-CS204AE-FMX-19-NGA |
| Cooling Principle | Closed-Cycle Gifford-McMahon Refrigeration |
| Base Temperature | <9 K |
| Temperature Range | <9 K to 350 K |
| Vacuum Compatibility | UHV (≤1×10⁻⁹ Torr) |
| Structural Material | Welded Stainless Steel with OFHC Copper Radiation Shield |
| Interface | 1.33" Mini-Conflat or VCR 1/4" |
| Cold Head | DE-204AE |
| Compressor | ARS-4HW |
| Helium Purity Requirement | 99.999% |
| Temperature Stability | ±0.1 K |
| Cooling Water Flow | 2.3 L/min @ 10–35 °C |
| Noise Level | 60 dBA |
| Dimensions (L×W×H) | 483×434×516 mm |
| Weight | 72 kg |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | LN-400 |
| Temperature Range | 77 K to 500 K (upgradable to 800 K) |
| Liquid Nitrogen Capacity | 0.4 L |
| Optical Window Diameter | 1.25 in (31.75 mm), High-Purity Fused Silica |
| Numerical Aperture Equivalent | f/1.4 |
| Temperature Sensor | Calibrated Silicon Diode (±0.5 K accuracy, dual placement: bath & sample stage) |
| Heating Element | 36 Ω Flat-Foil Heater |
| Electrical Interface | Hermetic 10-pin Feedthrough |
| Sample Stage | Removable Flat Plate Mount |
| Controller | Integrated PID Temperature Controller with RS-232/USB Interface |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | LT3-OM-1 |
| Cooling Medium | Liquid Helium / Liquid Nitrogen |
| Temperature Range | 2 K (under pumping) to 350 K |
| Base Temperature | ≤4.2 K |
| Liquid Helium Consumption | 0.7 L/hr @ 4.2 K |
| Cool-down Time | ~20 min |
| Configuration | Vertical |
| Sample Chamber Diameter | 1.52 in (38.6 mm) |
| Vibration Performance | Ultra-low |
| Optical Access | Coaxial, Microscope-integrated |
| Vacuum Housing | Electropolished Welded Stainless Steel |
| Compliance | Designed for UHV-compatible optical microscopy environments |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | LT4 |
| Operating Temperature Range | 4.2 K (liquid helium) to 77 K (liquid nitrogen) |
| Optical Window Diameter | 1.25 in (31.75 mm) |
| Window Material | High-purity fused silica |
| Base Temperature Stability | ±0.5 K |
| Helium Consumption Rate | 0.75 L/hr at 4.2 K |
| Structural Material | Aluminum alloy |
| Sample Viewing Angle | F/1 (broad field-of-view for optical collection) |
| Electrical Interface | 10-pin hermetic feedthrough + 4 dedicated test leads |
| Temperature Sensing | Calibrated silicon diode sensors (±0.5 K accuracy), dual-sensor configuration (cold stage + sample mount) |
| Standard Accessories | DMX-1AL aluminum radiation shield & vacuum shroud, helium transfer line, aluminum instrument panel, Dewar adapter, two quartz windows, 36 Ω foil heater, temperature controller |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | LT4-FTIR |
| Operating Temperature Range | 4.2 K (liquid helium) to 77 K (liquid nitrogen) |
| Optical Access | Dual high-purity quartz windows, 1.25″ clear aperture, F/1 field of view |
| Cooling Medium | Compatible with both liquid helium and liquid nitrogen |
| Helium Consumption | 0.75 L/hr at 4.2 K |
| Construction | Aluminum cold stage, aluminum radiation shield, aluminum vacuum housing (DMX-1AL) |
| Temperature Sensing | Two calibrated silicon diode thermometers (±0.5 K accuracy), one mounted on cold stage, one on sample holder with 4-ft lead |
| Electrical Interface | Hermetic 10-pin feedthrough, four test leads, integrated 36 Ω foil heater |
| Sample Mounting | Flat optical sample stage |
| Compliance | Designed for integration into FTIR, Raman, photoluminescence, and magneto-optical spectroscopy systems per ISO/IEC 17025-aligned laboratory practice |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | Orca Mixed Gas JT |
| Cooling Principle | Joule-Thomson (JT) Expansion Cycle |
| Base Temperature | 80 K |
| Refrigerant | Mixed Gas (N₂/Ar or similar blend) |
| Compressor Type | Air-Cooled |
| Vibration Level | < 1 µm RMS (typical) |
| Maintenance Requirement | None (no moving parts in cold head) |
| Standard Configuration | MR-80 Cold Head, Air-Cooled Compressor, Two Flexible High-Pressure Transfer Lines |
| Compliance | CE, RoHS, UL Listed (Compressor Unit) |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | X-12 |
| Cooling Capacity Options | 4 K, 5.5 K, or 10 K (with DE-202/DE-204 cold head) |
| Vacuum Enclosure Material | Non-magnetic anodized aluminum |
| Radiation Shield | Polished oxygen-free copper (OFHC), non-magnetic |
| Optical Aperture | DMX-12 (1.62 in) or DMX-12B (1.37 in) |
| Standard Optical Window | 1-inch fused silica |
| Temperature Sensing | Calibrated silicon diode (±12 mK accuracy, 4-ft lead) + control-grade silicon diode (±0.5 K) |
| Electrical Feedthrough | 10-pin hermetic connector |
| Sample Stage | Customizable non-magnetic mount for Hall/magneto-optical measurements |
| Compressor | ARS-2HW |
| Helium Transfer Lines | Two flexible cryogenic lines |
| Compliance | Designed for operation inside narrow-gap electromagnets and superconducting magnets (e.g., split-pair, vertical-field, or horizontal-field configurations) |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | X-12-1 |
| Type | Vertical |
| Cooling Source | Helium-Free Closed-Cycle Refrigeration |
| Base Temperature Options | 4 K, 5.5 K, or 10 K (dependent on cold head selection: DE-202 or DE-204) |
| Minimum Tail Diameter | 19 mm (standard: 25 mm) |
| Vacuum Jacket Material | Non-magnetic Aluminum |
| Radiation Shield | Polished Oxygen-Free Copper (replaces Ni-plated Cu) |
| Application-Specific Design | Optimized for in-situ magnetic field integration (e.g., electromagnets, superconducting magnets) |
| Compliance Context | Designed for GLP-compliant low-temperature characterization under static or swept magnetic fields |