| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-pH Plus |
| Instrument Type | Portable pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | pH 0.00–14.00 |
| Resolution | 0.01 pH |
| Accuracy | ±0.10 pH |
| Temperature Range | 10.0–40.0 °C |
| Temperature Accuracy | ±1.0 °C |
| Sample Volume Requirement | ≥0.6 mL |
| Electrode Type | Flat-surface glass pH electrode |
| Calibration Solutions | ATAGO-certified pH 4.01, 6.86, and 9.18 standard buffers |
| IP Rating | IP65 |
| Power Supply | Two AAA batteries |
| Dimensions | 5.5 × 3.1 × 10.9 cm |
| Weight | 100 g (instrument only) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-pH Plus |
| Instrument Type | Portable |
| Parameter Type | Single (pH) |
| Measurement Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.10 pH |
| Precision | ±0.1 pH |
| Minimum Sample Volume | 0.6 mL |
| Electrode Design | Smooth-surface, impact-resistant glass electrode |
| Calibration | Automatic 1–3 point calibration (standard buffers: pH 4.01, 7.00, 10.01) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PR-40DMF |
| Measurement Range | 0.0–40.0% (w/w) DMF |
| Resolution | 0.1% |
| Accuracy | ±0.3% |
| Temperature Compensation | 5–40°C (automatic) |
| IP Rating | IP64 |
| Power Supply | 9V battery (006P) |
| Dimensions | 17 × 9 × 4 cm |
| Weight | 300 g (without accessories) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | VISCO™ B(L) |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (Viscosity & Temperature) |
| Viscosity Range | 12–60,000,000 mPa·s (cP) across four rotor/speed combinations (L1–L4) |
| Temperature Range | 0.0–100.0 °C |
| Viscosity Accuracy | ±1% of full-scale reading |
| Temperature Accuracy | ±0.2 °C |
| Torque Measurement | 10.0–100.0 % |
| Power Supply | 4× LR6/AA alkaline batteries or AC adapter |
| Data Output | USB to PC |
| Dimensions (Main Unit) | 178 × 86 × 194 mm |
| Weight (Main Unit) | 1.2 kg |
| Compliance | Designed for GLP-compliant routine QC in chemical, pharmaceutical, and food laboratories |
| Brand | ATS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Kerr Microscope |
| Price Range | USD 68,000 – 136,000 |
| Magnetic Field | Up to 1.2 T (perpendicular), up to 0.8 T (in-plane) |
| Optical Resolution | Sub-micron (dependent on objective lens) |
| Wavelength Range | 405–1550 nm (configurable) |
| Imaging Frame Rate | Up to 100 fps (full FOV), real-time video acquisition |
| Sample Stage | Motorized XYZ + tilt, vacuum-compatible option available |
| Environmental Control | Temperature-stabilized optical platform, RH < 60 % recommended |
| Power Supply | 220 V, 50 Hz |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | d-shot |
| Measurement Principle | Dispersion-Scan (D-scan) |
| Pulse Duration Range | < 50 fs |
| Repetition Rate Support | Single-shot to MHz |
| Compatible Pulse Types | Few-cycle and Multi-cycle Pulses |
| Output | Full Electric Field Reconstruction (Amplitude & Phase) |
| Software | Real-time Retrieval Algorithm with Visual Trajectory Feedback |
| Compliance | Designed for GLP/GMP-aligned ultrafast labs |
| Brand | Metrohm Autolab |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Model | AUT-RDE |
| Rotation Speed Range | 0–10,000 rpm (1 rpm step size, acceleration: 4,000 rpm/s) |
| Speed Control | Manual or external potentiostat-triggered (e.g., Autolab, CHI, Biologic) |
| Speed Feedback | Integrated optical encoder with closed-loop control (±2 rpm accuracy at 10,000 rpm) |
| Contact Method | Dual-seal mercury pool (liquid Hg-based conduction, no carbon brushes required) |
| Sealing | Fully sealed rotating assembly immersed in electrolyte cell |
| Electrode Head Compatibility | Interchangeable RRDE and RDE heads |
| RRDE Head Options | Pt/Pt, Au/Pt, GC/Pt |
| Collection Efficiency | 24.9% (calibrated per ASTM D3765-18 practice) |
| Disk-Ring Gap | 375 µm |
| Max Current Rating | 500 mA |
| Footprint | Compact design optimized for glovebox integration (W × D × H: 185 × 160 × 320 mm) |
| Brand | Autolab |
|---|---|
| Origin | Imported (Netherlands) |
| Instrument Type | Electrochemical Impedance Spectroscopy (EIS) Control & Analysis Software |
| Frequency Range | 10 Hz – 1 MHz (single-sweep, no segmentation required) |
| Supported Measurement Modes | Potentiostatic EIS, Galvanostatic EIS, Potential Sweep EIS, Current Sweep EIS, Time-Resolved EIS |
| Data Visualization | Nyquist, Bode ( |
| Curve Fitting Engine | EQUIVCRT-based equivalent circuit modeling |
| Validation Tools | Kramers–Kronig transform consistency testing |
| Compliance | Fully compatible with Autolab PGSTAT series potentiostats/galvanostats |
| Brand | AWSensors |
|---|---|
| Origin | Spain |
| Model | QCM-D |
| Channel Options | 1-channel or 4-channel modular system |
| Sensor Interface | AT-cut quartz crystals with Cr/Au/Ti electrodes |
| Cell Design | Patented quick-lock mechanism with FFKM or PDMS sealing |
| Measurement Modes | Static (Batch) and dynamic flow-through (Flow) |
| Software Platform | AWSensors Control & Analysis Suite |
| Compliance Framework | Designed for GLP-compliant data integrity |
| Optional Modules | Temperature control unit (±0.1 °C stability), precision flow control unit (integrated dual-position, six-port valve with degassing module), potentiostat integration for electrochemical QCM (EQCM) |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | 300W PEM Fuel Cell Stack |
| Rated Power | 300 W (DC) |
| Output Voltage Range | 15–30 V DC |
| Nominal Current | 18 A |
| Operating Temperature | 5–55 °C |
| Electrical Efficiency | 45% @ 300 W |
| Fuel | 99.9% H₂ and ambient air |
| H₂ Consumption | 4.5 L/min (STP) |
| H₂ Inlet Pressure | 250–350 mbar(g) |
| Number of Cells | 30 |
| Cooling | Liquid-cooled |
| Interface | 1/4" internal thread (ISO 7/1) |
| Dimensions | 175 × 85 × 95 mm |
| Weight | 1.7 kg |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | DiLiCo CURR TEMP |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A/cm² |
| Current Accuracy | ±0.01 A (1% of reading) |
| Voltage Range | ≤2.5 V |
| Voltage Resolution | Not specified |
| Potentiostatic Range | 25 V |
| AC Impedance Frequency Range | 10 Hz |
| Temperature Range | ≤120 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Scan Interval | 2.0 s |
| Sensor Array | 48 nodes (6 × 8) |
| Node Size | 7 mm × 7 mm (0.5 cm²) |
| Node Material | Gold-plated |
| Communication Interface | CAN, USB |
| External Temperature Inputs | Up to 5 (PT-100/PT-500/PT-1000) |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | Electrum 1000W |
| Output Power | 1000 W |
| Output Voltage Options | 24 V DC (20.5–27.5 V), 48 V DC (40.5–55 V), or 110–230 V AC |
| Rated Current | 40 A (24 V), 20 A (48 V), 4.5 A (230 V AC) |
| Operating Temperature | 5–45 °C |
| Hydrogen Consumption | 11 SL/min |
| Hydrogen Inlet Pressure | 2–20 bar |
| Dimensions (W×H×D) | 482 × 244 × 500 mm |
| Net Weight | 15 kg (24 V), 17 kg (48 V), 20 kg (AC inverter variant) |
| Response Time | Instantaneous |
| Enclosure | IP-rated, rack-mountable 19″ chassis |
| Compliance | CE, UL/cUL listed (per IEC 62282-2), EN 60950-1, ISO 14687-2 (hydrogen quality interface) |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | qCF RFB |
| Weight (Fixture) | 10 kg |
| Dimensions (Fixture) | 300 mm × 300 mm × 230 mm |
| Active Area | 40 cm² (52 mm × 77 mm) |
| Electrode Travel Range | ±6 mm per side |
| Compression Adjustment | Manual, center-supported lever mechanism |
| Force Transmission | Direct clamping via quick-link principle |
| Temperature Control | External recirculating chiller/heater required |
| Operating Temperature Range | −6 °C to +60 °C |
| Fluid Contact Materials | Graphite and chemically resistant plastics only |
| Current Collection | Stainless steel / gold-plated terminals |
| Electrical Interface | 6 mm multi-point binding posts |
| Distance Measurement | Digital caliper with 0.01 mm resolution |
| Tubing Material | PVC |
| Compliance | Designed for ASTM E2981, IEC 62933-2-1, and ISO 14687-compliant RFB component validation |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | QCF-125 |
| Active Area per Cell | 25 cm² |
| Max. Number of Cells | 5 |
| Temperature Range | up to 140 °C |
| Contact Pressure | up to 6.28 kN (2.5 N/mm², equivalent to 8 bar) |
| Gas Inlet/Outlet Port Diameter | Ø 8 mm |
| Pneumatic Control Port Diameter | Ø 4 mm |
| Electrical Interface | 1 mm sensor wire socket, 8 mm load current terminal |
| Stack Thickness Adjustment Range | up to 0.9 mm per MEA |
| Dimensions (L×W×H) | 465 × 175 × 242 mm |
| Net Weight | 13.5 kg |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | QCF12 |
| Active Area | 12 cm² |
| Piston Diameter | Ø100 mm |
| Mass | 6 kg |
| Max Contact Pressure | 2.5 N/mm² |
| Operating Temperature Range | −20 to 150 °C |
| Coolant–Cathode Outlet ΔT | ≤1 K at 5 A/cm² |
| Cooling/Heating Medium | External Liquid Circulator (not included) |
| Gas Inlet Fittings | Ø4 mm (fuel/air supply via Ø6 mm ports) |
| Electrical & Thermal Interface | Stainless Steel with Gold-Plated Contacts and FKM Seals |
| Actuation | Motorized 5/2 Solenoid Valve |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | QCF25 |
| Instrument Type | Electrochemical Workstation Accessory |
| Current Range | ±5 A |
| Current Accuracy | ±0.1% of full scale |
| Potential Accuracy | ±15–32 µV |
| Potentiostatic Range | ±25 V |
| EIS Frequency Range | 10 Hz – 1 MHz (system-dependent, requires compatible potentiostat) |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | QCF50 |
| Active Area | 50 cm² |
| Pressure Control | Pneumatically Actuated, Continuously Adjustable |
| Temperature Compatibility | –50 °C to +250 °C (with optional TCU) |
| Compliance | Designed for ISO/IEC 17025-compliant lab environments |
| Customization | Available for PEMFC, AEMFC, electrolysis, and metal–air cells |
| Accessories | CMD compression monitor, CSL current distribution scanner, DHRE_Pt reference electrode, HSE humidity sensors, flow-field customization, liquid-cooled/heated manifolds |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | SuSy300 |
| Output Power | 300 W (nominal) |
| DC Voltage Range | 16–21 V |
| Rated Current | 18 A |
| System Efficiency | 45% @ 300 W |
| Fuel | 99.9% H₂ + ambient air |
| H₂ Inlet Pressure | 2–20 bar |
| Startup Time | <3 s |
| Safety Monitoring | Integrated H₂ pressure & temperature sensors |
| Gas Port | 1/8" internal thread |
| Control Interface | SUB-D9 connector, RS-232 protocol |
| Dimensions | 244 × 155 × 180 mm |
| Weight | 3.9 kg |
| Brand | Baltic FuelCells |
|---|---|
| Origin | Germany |
| Model | SuSy500 |
| Rated Power | 500 W (DC) |
| Output Voltage Range | 24–32 V DC |
| Nominal Current | 18 A |
| System Efficiency | 45% at 500 W |
| Fuel | 99.9% H₂ + Ambient Air |
| H₂ Inlet Pressure | 2–20 bar |
| Startup Time | <3 s |
| Safety Sensors | Integrated H₂ pressure & temperature monitoring |
| Gas Interface | 1/8″ NPT internal thread |
| Control Interface | SUB-D9 connector, RS-232 protocol |
| Dimensions | 244 × 155 × 180 mm |
| Weight | 3.9 kg |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | BE-8 |
| Travel Range (Coarse X-axis) | 40 mm |
| Mounting Interface | 10 mm diameter rod |
| Dimensions (W×D×H) | 140 × 25 × 95 mm |
| Weight | 210 g |
| Type | Single-Axis Coarse Micromanipulator |
| Application | Stereotactic Auxiliary Positioning |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Portable pH Meter |
| Model | PHS-3C |
| Measurement Range | 0.00–14.00 pH / ±1999 mV |
| Resolution | 0.01 pH / 1 mV |
| Accuracy | ±0.01 pH (electronic unit) / ±0.02 pH (system, including electrode) |
| Temperature Compensation Range | 0–60 °C |
| Input Impedance | ≥1 × 10¹² Ω |
| Input Current | ≤2 × 10⁻¹² A |
| Stability | ±0.01 pH ±1 digit / 3 h |
| Repeatability | ≤0.01 pH |
| Display | 3½-digit LED |
| Power Consumption | ≤5 W |
| Dimensions (L×W×H) | 260 × 190 × 70 mm |
| Weight | 1.5 kg |
| Operating Environment | 5–40 °C, RH ≤85%, AC 220 V ±10%, 50 Hz |
| Calibration | One-point or two-point with standard USA pH buffers |
| Compliance | Meets Chinese National Standard JJG 919–2008 (pH meter verification regulation), aligned with ISO 7027 and ASTM D1293 for aqueous pH measurement traceability |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic |
| Model | Be Foil |
| Price Range | USD 1–999 |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Bi₂Se₂Te |
| Price | Upon Request |
| Crystal System | Hexagonal, Space Group R-3m (No. 166) |
| Lattice Parameters | a = 4.38 Å, c = 30.5 Å |
| Purity | 99.999% (5N) |
| Stoichiometric Tunability | ±5% atomic ratio control |
| Resistivity | 0.1–5 mΩ·cm |
| Carrier Mobility | 1000–5000 cm²/V·s |
| Standard Dimensions | 8 × 8 × 0.1 mm³ or 5 × 5 × 0.1 mm³ |
| Cleavage Plane | Basal (0001) |
| Packaging | Class 100 cleanroom bag, stored in Class 1000 cleanroom environment |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | T-BD5-MS1200 |
| Price | Upon Request |
| Measurement Principle | Microwave Attenuation at 100 MHz |
| Range | 0.5–100 vol% |
| Accuracy | ±1–5% FS |
| Resolution | <0.01 vol% |
| Sensor Operating Temp. | −10 to 80 °C |
| Max. Process Pressure | 1.6 MPa |
| Output | 4–20 mA (linear) |
| Power Supply | DC 12–24 V |
| Power Consumption | <1.40 W (typ. <0.5 W) |
| Enclosure Rating | IP65 |
| Explosion Protection | Ex d ia IIC T5 |
| Installation Options | NPT 1", DN50 flange, tri-clamp |
| Insertion Depth | 60–230 mm (customizable) |
| Wetted Materials | PTFE, SS304, SS316 |
| Compliance | Designed for GLP/GMP-aligned process monitoring environments |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | BCS-905 / BCS-910 / BCS-915 |
| Instrument Type | Multichannel Electrochemical Workstation & Battery Cycler |
| Channel Configuration | Modular Multichannel (up to 16 channels per rack) |
| Current Range | BCS-905: 15 µA–150 mA (5 ranges) |
| BCS-910 | 150 µA–1.5 A (5 ranges) |
| BCS-915 | 1.5 mA–15 A (5 ranges) |
| Current Accuracy | ±0.015% of range + ±0.05% of reading (15 µA–150 mA) |
| Potential Accuracy | ±0.01% of set value + 300 µV |
| Potentiostatic Range | BCS-905/910: 0–10 V |
| BCS-915 | 0–9 V |
| EIS Frequency Range | 10 mHz–10 kHz |
| Resolution | 18-bit DAC/ADC for current and voltage control and acquisition |
| Thermal Compatibility | Fixture support up to 150 °C |
| Parallel Operation | Scalable to 120 A via synchronized multi-unit parallel configuration |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | FlexP 0160 |
| Current Range | ±50 A per channel (up to ±200 A with 4-channel parallel configuration) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz – 1 MHz |
| Voltage Compliance Range | 1–60 V |
| Voltage Accuracy | 0.2% of reading ± 0.1% FS |
| Current Accuracy (high-current mode) | 0.2% of reading ± 0.1% FS up to 50 A |
| Slew Rate | 1 V/μs |
| Rise/Fall Time | 20 μs |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | HCP-803 |
| Current Range | ±80 A |
| Current Resolution | 760 pA (1 nA–400 nA range) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| Dynamic Potential Resolution | 300 µV (adjustable down to 5 µV) |
| EIS Frequency Range | 10 µHz–1 MHz (standard), 10 µHz–10 kHz (with 80 A booster) |
| Booster Module | Removable high-current extension unit |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | HCV-3048 |
| Current Range | ±30 A (per channel), up to ±120 A (4-channel parallel operation) |
| Current Accuracy | 0.1–0.3% (range + reading) |
| Potential Accuracy | <5 mV (on ±2.5 V range) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Voltage Range | 0–48 V |
| Voltage Accuracy | 0.03% (range + reading) |
| Slew Rate | >20 V/µs |
| Rise/Fall Time | <3 µs (0–48 V step) |
| Input Impedance | 100 GΩ |
| Bandwidth | 800 kHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | M470 |
| Instrument Type | Scanning Electrochemical Workstation |
| Current Range | 1 pA – 10 A |
| Current Accuracy | ±0.0033% of reading |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Scan Range (X/Y/Z) | >100 mm |
| Closed-Loop Positioning Resolution | 0.1 nm |
| Spatial Resolution (X/Y/Z) | 20 nm |
| Max Scan Speed | 12.5 mm/s |
| ADC/DAC Resolution | 32-bit @ up to 40 MHz |
| Piezo Vibration Range | 20 nm – 2 µm (peak-to-peak, 1 nm step) |
| Piezo Minimum Vibration Resolution | 0.12 nm (16-bit DAC, 4 µm range) |
| Piezo Extension | 100 µm |
| Piezo Positioning Resolution | 0.09 nm (20-bit DAC, 100 µm range) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MPG-2XX |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±40 A |
| Current Accuracy | ±20 nA on 10 μA |
| Potential Accuracy | <5 mV on ±2.5 V |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz – 1 MHz |