Electrochemical Instruments
Filter
Showing 121–150 of 1703 results
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MPG2 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±10 A (per channel with optional high-current modules) |
| Current Resolution | 760 pA |
| Potential Accuracy | ±5 µV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 20 kHz |
| Data Acquisition Rate | 200,000 points/s |
| Channels | 16 independent, fully isolated |
| Voltage Resolution | 300 µV (dynamic range adjustable down to 5 µV) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-150e |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | Dual-Channel |
| Current Range | ±1 A |
| Current Resolution | 760 pA (optional 76 fA) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Voltage Resolution | 300 μV (dynamically adjustable down to 5 μV) |
| Data Acquisition Rate | 200,000 points/s |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-200 |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±500 mA |
| Current Resolution | 76 aA |
| Potential Accuracy | ±0.1% of full scale |
| Potentiostatic Range | ±12 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Voltage Resolution | 1 µV (dynamic range adjustable down to 1 µV) |
| Data Acquisition Rate | 1,000,000 points/second |
| Optional ULC Module | 100 pA (down to 1 pA) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-300 |
| Channel Count | Dual-channel |
| Current Range | ±500 mA |
| Current Resolution | 76 aA |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±48 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Data Acquisition Rate | 1,000,000 pts/s |
| Voltage Resolution | 1 µV (dynamic range adjustable) |
| Optional Modules | ULC (1 pA), High-Current (4 A/14 V), High-Voltage (1 A/48 V) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-50e |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±20 nA (on 10 μA range) |
| Potential Accuracy | <5 mV (on ±2.5 V range) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Current Resolution | 760 pA |
| Voltage Resolution | Adjustable from 300 μV down to 5 μV |
| Data Acquisition Rate | 200,000 points/s |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Uniscan M370 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±1 A |
| Current Accuracy | ±0.1% of reading |
| Potential Accuracy | ±10 mV |
| Potentiostatic Range | ±20 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VMP-300 |
| Number of Channels | 16 |
| Current Range | ±500 mA |
| Current Accuracy | ±0.1% |
| Potential Accuracy | ±0.1% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Voltage Compliance | ±12 V |
| Control Voltage Range | ±10 V |
| Current Resolution (standard board) | 760 fA |
| Floating Mode | Yes |
| Analog Filtering | Built-in |
| Calibration Board | Integrated |
| Control Stability | Digital PID with adaptive tuning |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VMP-3e |
| Channel Count | 16 independent channels |
| Current Range | 76 fA to 100 A (with external amplifiers) |
| Current Accuracy | ±0.1% |
| Potential Range | ±10 V (DC), 0–20 V (galvanostatic mode) |
| Potentiostatic Range | ±20 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Data Acquisition Rate | 200,000 points/sec |
| Potential Resolution | 300 µV (dynamic range adjustable down to 5 µV) |
| Switching Time (Potentiostatic ↔ Galvanostatic) | <10 µs |
| Input Impedance | >10^14 Ω |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP |
| Channel Count | 5 independent channels |
| Current Range | 1 nA to 100 A (with external amplifier) |
| Current Resolution | 76 fA |
| Potential Accuracy | ±5 µV |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±4 A (built-in), up to ±100 A (with external current booster) |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Data Acquisition Rate | 200,000 points/s |
| Voltage Resolution | 300 µV (dynamic adjustment down to 5 µV) |
| Supported Techniques | CV, LSV, CA, CP, EIS (potentiostatic/galvanostatic/step-mode), DPV, SWV, NPV, Mott-Schottky, ZRA/ZVC, corrosion polarization, GITT, PITT, constant-power discharge, potentiometric titration, and multi-step sequence protocols |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP-300 |
| Channel Count | 6 |
| Current Range | ±500 mA |
| Current Resolution | down to 76 aA (with ULC option) |
| Current Accuracy | ±20 nA on 10 µA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±1 A (extendable to ±20 A) |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Sampling Rate | up to 1 µs |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Software | EC-Lab® v12+ with FDA 21 CFR Part 11-compliant audit trail option |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP-3e |
| Channel Count | 8 |
| Current Range | ±1 pA to ±1 A |
| Current Accuracy | ±0.0033% of reading |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±10 V (adjustable up to ±20 V) |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Voltage Resolution | 5 µV (within ±200 mV range) |
| Current Resolution | 0.76 nA |
| Minimum Sampling Interval | 200 µs |
| Control Bandwidth | 7 adjustable bandwidths |
| Connectivity | Ethernet (LAN), USB, optional EIS module |
| Brand | BioLight |
|---|---|
| Model | Lux-P110 |
| Detection Principle | Photon counting via cooled photomultiplier tube (PMT) |
| Dynamic Range | ≥ 7 decades (typical for high-end luminometers) |
| Sensitivity | ≤ 10 amol ATP (firefly luciferase assay, 96-well plate) |
| Read Modes | Flash & Glow luminescence |
| Plate Formats | 6–1536-well microplates |
| Temperature Control | Ambient to 45 °C (±0.5 °C uniformity) |
| Integrated Injector | Dual-channel, programmable, in-situ dispensing |
| Shaking | Tri-mode (linear, orbital, circular) with six speed settings (200–1200 rpm) |
| Detector | Thermoelectrically cooled PMT (−20 °C operating temperature) |
| Software | LuxWin v5.x with FDA 21 CFR Part 11-compliant audit trail, GLP/GMP reporting templates, and kinetic/endpoint/multiple-injection protocols |
| Compliance | ISO/IEC 17025-aligned validation support, ASTM E2578-21 referenced for luminometer performance verification |
| Data Export | CSV, XML, PDF, Excel-compatible formats |
| Brand | BioLight |
|---|---|
| Model | Lux-T020 |
| Origin | Guangdong, China |
| Detector Type | Electrochemiluminescence & Bioluminescence Luminometer |
| Photomultiplier Tube (PMT) | Single-Photon Counting PMT |
| Max Count Rate | >100 million pulses/sec |
| Detection Sensitivity | ≤10 amol ATP or 20 zmol firefly luciferase |
| Dynamic Range | 7 decades (linear) |
| Sample Format | 12 × 55 mm test tubes or standard 0.5–2.0 mL microcentrifuge tubes |
| Interface | Touchscreen GUI with USB data export |
| Compliance | Designed for GLP-compliant workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S400-RTPBO-M10ST |
| Pricing | Upon Request |
| Brand | BQC |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BRS |
| Pricing | Available Upon Request |
| Brand | BRAND® |
|---|---|
| Origin | Germany |
| Model | 4760161 |
| Measurement Range | 0.2–10 mL |
| Meter Accuracy | ±0.1% |
| Meter Resolution | 0.001 mL |
| Dispensing Accuracy | ≤±0.2% |
| Dispensing Resolution | 0.001 mL |
| Compliance | DIN EN ISO 385 (Class A volumetric accuracy) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S400-RT33H-E10FF |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 76652-03 |
| Pricing | Available Upon Request |
| Compliance | ASTM D5682 |
| Measurement Parameters | Volume Resistivity (1–1999 kΩ, 0–199.9 MΩ, 0–19.99 GΩ), Short-Circuit Current (0–250 µA, with optional gun output terminal), Static Voltage (0–199.9 kV, with optional HV test terminal) |
| Display | Direct digital readout |
| Electrode | Stainless steel tubular 4-ring probe |
| Probe Dimensions | Φ42 mm × 250 mm |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BDA-36 |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | PHS-2C |
| Price Range | USD 70–140 |
| Instrument Type | Portable |
| Parameter Types | pH and mV |
| Measurement Range | pH 0.00–14.00 |
| Resolution | 0.01 pH / 1 mV |
| Accuracy | ±0.05 pH / ±0.5% F.S. (mV) |
| Temperature Compensation Range | 0–60.0 °C |
| Input Impedance | ≥3×10¹¹ Ω |
| Stability | ≤0.05 pH ±1 digit / 2 h |
| Calibration | One-point or Two-point (using USA-standard buffer solutions) |
| DC Output | 0–±2 V analog signal |
| Instrument Class | 0.02/0.05 grade |
| Key | Brand: Caikon |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic Instrument |
| Model | CKJF-4G |
| Price Range | USD 2,650 – 2,950 |
| Compliance | GB/T 4334–2020, ASTM A262–2015 |
| Heating Capacity | 2000 W total (4 × 500 W independent stations) |
| Max Operating Temperature | 400 °C |
| Simultaneous Samples | 4 |
| Control System | PLC + PID with touchscreen HMI |
| Cooling | Integrated reflux condensation system (no external water source required) |
| Safety Features | Dry-run alarm, overtemperature cutoff, power-interruption resume function |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | CD-10 |
| Price Range | USD 280–420 |
| Instrument Type | Multifunctional pH Controller |
| Measurement Range | 0–14 pH |
| Resolution | 0.01 pH |
| Input Impedance | >10¹² Ω |
| Output Signals | 4–20 mA analog output |
| Power Supply | 220 V AC, 50 Hz |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | CD-12 |
| Price | Upon Request |
| Brand | CEL (China Education Goldsource) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CEL-PCRD50-2 LED Photoreactor |
| Pricing | Upon Request |
| Sample Capacity | 2 × 50 mL (quartz reaction tubes) |
| Illumination Mode | Dual independent side-illumination |
| Illumination Area per Position | 100 mm × 20 mm (standard, for 50 mL) |
| LED Power | 2 × 25 W (DC 38 V, ±0.01%) |
| Total Input Power | 100 W (AC 220 V, ±0.01%) |
| Wavelength Options | 365, 395, 405, 420, 455, 470, 500, 520, 590, 620, 660, 740, 810, 850, 940 nm + white LED |
| Control Interface | Digital display with rotary knob adjustment |
| Modular Light Source | PCRS25 lamp housing with hot-swap capability |
| Cooling | Passive (fan-assisted, no water cooling required) |
| Uniformity | High-intensity uniform irradiation without filters or collimators |
| Temperature Control | Compatible with external cold well (optional) |
| Gas Handling | Integrated gas inlet/outlet and vacuum ports per station |
| Stirring | Dual independent magnetic stirring (speed adjustable) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | CHI400C |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | CHI900D |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Instrument Type | Bipotentiostatic Electrochemical Workstation |
| Channel Count | Single-Channel Bipotentiostat |
| Current Range | ±250 mA continuous (sum of two channels), ±350 mA peak |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±1 mV or ±0.01% of full scale |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| XYZ Positioning System | Stepper-motor-driven |
| resolution | 8 µm (CHI900D), travel: 50 mm per axis |
| Optional High-Resolution Mode | Closed-loop piezoelectric stage (CHI920D variant) |
| resolution | 1.6 nm |
| Core Functionality | Dual-potentiostat with zero-resistance ammeter (ZRA) mode for feedback-mode SECM, generation-collection (G/C) mode, and redox competition (RC-SECM) experiments |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CH154-SA |
| Price | Upon Request |
| Length | 120 mm |
| Tip Opening Diameter | 2.6 mm |
| Tip Geometry | Vertical Alignment |