Environmental Monitoring Instruments
Filter
Showing 361–390 of 2616 results
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | Stack Gas2001 (600/ISS1400K) |
| Instrument Type | Heated Flue Gas Sampling Probe |
| Flow Accuracy | ±2% of full scale |
| Probe Length Options | 350 mm / 750 mm |
| Heating Element | Integrated, temperature-controlled |
| Filter | In-probe heated particulate filter (ceramic or sintered metal, typical operating temp: 180–200 °C) |
| Power Supply | Internal 14 Ah sealed lead-acid battery (rechargeable, designed for ≥500 cycles) |
| Sampling Line Assembly | Dual-layer polyethylene tubing (1.25 m length), integrated cooling jacket + electronic control unit (P/N 2100152) |
| Optional Integration | Compatible with DiluGas™ dynamic dilution system (dual-input interface) |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Model | AMT-CO₂ |
| Measurement Principle | Optical NDIR (Single-Beam, Dual-Wavelength) |
| Range Options | 15 / 50 / 340 mg/L (customizable) |
| Accuracy | ±2% of reading (5–15 mg/L range) |
| Housing Material | Titanium |
| Dimensions | Ø33 mm × 225 mm |
| Operating Depth | Up to 1000 m |
| Power Supply | 12–30 VDC (digital/voltage output) |
| Power Consumption | <0.5 W |
| Warm-up Time | <12 s (initial stabilization), <2 min (optimal accuracy) |
| Output Options | 4–20 mA, 0–5 V, RS485 |
| Temperature Compensation | Internal, automatic |
| Humidity Compensation | Internal, automatic |
| Operating Temperature | 0–60 °C |
| Immersion Capability | Fully submersible in water or air |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-CTD/O2 |
| Price | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-EC7 |
| Instrument Type | Online |
| Conductivity Ranges | 0–1 mS/cm |
| Outer Diameter | 40 mm |
| Total Length | ~270 mm |
| Weight | ~300 g |
| Housing Material | Titanium |
| Pressure Rating | 6000 m (6000 dbar) |
| Output Signal | 0–2.5 V DC or 0–5 V DC |
| Supply Voltage | 9–18 V DC |
| Connector | SubConn wet-mateable underwater connector |
| Measurement Principle | Seven-electrode AC conductivity with quartz-glass sensing tube |
| Channels | 4 measurement electrodes + 1 excitation + 2 guard/ground electrodes |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2S |
| Price | Upon Request |
| Measurement Principle | Amperometric (Clark-type, 3-electrode) |
| Power Supply | 9–30 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø24 mm × 235 mm |
| Connector | SUBCONN BH-4-MP (optional alternatives available) |
| Warm-up Time | 5–15 min |
| Electrolyte Consumption | Low |
| Measurement Ranges | Type I: 0.05–10 mg/L H₂S |
| Type II | 0.5–50 mg/L H₂S |
| Type III | 0.01–3 mg/L H₂S |
| Accuracy | ±2% of reading |
| Operating Temperature | 0–30 °C |
| pH Range | 0–8.5 |
| Response Time (t₉₀) | <200 ms |
| Typical Service Life | 5–9 months |
| Pressure Rating | >10 bar |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-O2 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-O3 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-ORP |
| Price | Upon Request |
| Measurement Range | ±2000 mV |
| Resolution | 0.1 mV |
| Accuracy | ±2 mV |
| Power Supply | 9.5–18 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø30 mm × 250 mm |
| Pressure Rating | 600 dbar |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Model | AMT-pH |
| Instrument Type | Online |
| pH Range | 2–11 (standard) |
| Resolution | 0.01 pH |
| Accuracy | ±0.05 pH |
| Supply Voltage | 9.5–18 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø30 mm × 250 mm |
| Pressure Rating | 600 dbar |
| Electrode Integration | Integrated glass + reference electrode in single housing |
| Membrane Design | Dual-junction diaphragm |
| Operating Depth | Up to 6000 m |
| Temperature Sensor | Not integrated |
| Compliance | Designed for ISO 10523, ASTM D1293, and marine GLP-compliant in-situ deployments |
| Brand | AMT (Germany) |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Instrument Type | Online |
| Measurement Principle | Electrochemical (Polarographic Membrane-Type) |
| Accuracy | ±2% of reading |
| Power Supply | 9–30 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø25 mm × 240 mm |
| Air Weight | 260 g |
| Interface | SUBCONN BH-4-MP |
| Housing Material | Titanium & POM |
| Pressure Rating | 200 dbar (2000 m) or 600 dbar (6000 m) |
| Response Time (t₆₃%) | ~10 s |
| Dual-Membrane Configuration | Inner sensing membrane + outer protective membrane |
| Polarization Power Source | Integrated Li-ion battery (auto-disengaged when external power is applied) |
| Cable | Multi-core 4-wire marine-grade cable |
| Environmental Compatibility | Seawater, freshwater lakes & rivers |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Not Specified |
| Price | Upon Request |
| Dimensions | 220 mm × 160 mm × 250 mm |
| Power Supply | 230 V AC |
| Flow Rate | 10–12 mL/min |
| Dissolved Oxygen Range | 0.4 µg/L – 9.95 mg/L |
| Accuracy | ±0.25% of reading |
| Response Time | ≤5 min |
| Deoxygenation Efficiency | Residual O₂ < 35 µg/L |
| Deaeration Protocol | 45-min purge followed by ~5-min equilibration |
| Calibration Reference Method | Winkler titration per DIN 38408-21 (modified) |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | AMT G200 Coulometric H₂S Sulfide Generator |
| Price | Upon Request |
| Concentration Range | 0.002–60.0 mg/L H₂S (0.062–1871 µmol/L H₂S) |
| Electrode Capacity | ≈350 mAh |
| Dimensions | 220 mm (L) × 160 mm (W) × 250 mm (H) |
| Accuracy | ±0.25% (amperometric probe) |
| Purge Time | ~45 min |
| First Concentration Transition | ~15–30 min |
| Concentration Step Response Time | 1 h per 10 steps (dependent on step magnitude and gas flow rate) |
| Repeatability | 99.78% (amperometric), 97.51% (methylene blue) |
| Dry-Run Tolerance | ~4 working days |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | MS08 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | pH |
| Price | Upon Request |
| Brand | AMT (Germany) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2S/Sulfide |
| Price | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Model | AMT-H2O2 |
| Electrode Configuration | 3-electrode amperometric |
| Membrane Material | Silicone elastomer |
| Output Signal | 0–5 V DC proportional to partial pressure (0–400 Pa) |
| Measurement Range (Type I) | 0.02–10% w/w H₂O₂ |
| Accuracy | ±1% of full scale |
| Response Time (t₉₀) | 1–2 s |
| Operating Temperature | 0–30 °C |
| pH Range | 0–11 |
| Pressure Rating | >10 bar |
| Housing Material | Titanium |
| Typical Service Life | 5–9 months |
| Polarization Time | 5–15 min |
| Probe Replaceability | Yes |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ASP-BB02-Y1101 |
| Instrument Type | Portable |
| Detection Target | Single Gas (CO₂) |
| Range | 0–5 %vol (0–50,000 ppm) |
| Resolution | 0.01 %vol |
| Repeatability | ±1 % of reading |
| Zero Drift | ±1 % FS/month |
| Span Drift | ±2 % FS/month |
| Linearity Error | ±2 % FS |
| Response Time (T90) | <60 s |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| EMC Compliance | 2004/108/EC |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida O₂ |
| Instrument Type | Portable |
| Measurement Range | 0.1–25% O₂ (v/v) |
| Accuracy | ±0.0075% O₂ |
| Resolution | 0.1% O₂ |
| Repeatability | ±1% of reading |
| Zero Drift | <1% O₂ per month |
| Span Drift | <1% O₂ per month |
| Linearity Error | ±1% of full scale |
| Visual Indication | Green (normal), Amber (fault), Triple Red (alarm) |
| Audible Alarm | 95 dB @ 30 cm |
| Emergency Alarm | 110 dB @ 30 cm |
| Vibration Alert | Yes |
| T90 Response Time | <30 s |
| Operating Temperature | −5 °C to +50 °C |
| IP Rating | IP65 |
| Dimensions | 127 mm × 44 mm × 90 mm |
| Weight | 355 g |
| Power | Dual-mode — rechargeable Li-ion battery or two AA alkaline cells |
| Data Logging | Time-weighted average (TWA), STEL, peak hold |
| Compliance | ATEX II 2G Ex ib IIC T4 Gb, IECEx Ex ib IIC T4 Gb, UKCA, CE |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida O2 |
| Instrument Type | Portable |
| Sensor Range | 0.1–25% O₂ |
| Accuracy | ±0.0075% O₂ |
| Visual Alarm Indicators | 1× green (normal), 1× amber (fault), 3× red (alarm) |
| Audible Alarm | 95 dB @ 30 cm |
| Emergency Alarm | 110 dB @ 30 cm |
| Response Time (T90) | <30 s |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| Dimensions | 127 × 44 × 90 mm |
| Weight | 355 g |
| Power | Dual-mode — rechargeable Li-ion battery or two standard AA alkaline cells |
| TWA Calculation | Yes |
| Vibration Alert | Yes |
| Multi-user Support | Up to 2 users with individual calibration & usage logs |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | ASPIDA |
| Instrument Type | Portable |
| Detection Target | Single-component (CO₂) |
| Measurement Range | 0.01–5.00% vol CO₂ |
| Resolution | 0.01% vol |
| Accuracy | ±2% FS (0.01–2.5% range), ±3% FS (2.5–5.0% range) |
| Response Time (T90) | <60 s |
| Zero Drift | <±1% FS/6 months |
| Span Drift | <±1% FS/6 months |
| Linearity Error | ≤1% FS |
| Operating Temperature | –5 to +50 °C |
| Battery | 2×2100 mAh NiMH AA |
| Runtime | >12 h per charge |
| Charging Time | 4.5 h |
| Display | High-visibility OLED |
| Audible Alarm | 95 dB @ 30 cm (110 dB for fall detection) |
| Visual Indicators | 1 green LED (normal), 1 yellow LED (fault), 3 red LEDs (alarm) |
| Sensor Technology | Non-dispersive infrared (NDIR), MIR-based |
| CO₂ Sensor Lifetime | 5 years |
| Optional O₂ Sensor | Electrochemical, 0.1–25.0% vol, T90 <30 s, lifetime 2 years |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | ASPIDA |
| Instrument Type | Portable |
| Detection Target | Single-Gas (CO₂) |
| Measurement Range | 0.01–5.00% vol CO₂ |
| Resolution | 0.01% vol |
| Accuracy | ±2% FS (0.01–2.5% range), ±3% FS (2.5–5.0% range) |
| Response Time (T90) | <60 s |
| Zero Drift | ±1% FS/6 months |
| Span Drift | ±1% FS/6 months |
| Linearity Error | ±1% FS |
| Operating Temperature | –5 to +50 °C |
| Battery | 2 × 2100 mAh NiMH AA |
| Runtime | >12 h (continuous) |
| Charging Time | 4.5 h |
| Display | High-visibility OLED |
| Alarm | 95 dB @ 30 cm (audible), tri-color LED indicators, fall detection alarm (110 dB) |
| Sensor Technology | Non-dispersive infrared (NDIR), MIR-based |
| CO₂ Sensor Lifetime | 5 years |
| Optional O₂ Sensor | Electrochemical, 0.1–25.0% vol, T90 <30 s, 2-year lifetime |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida |
| Instrument Type | Portable |
| Detection Target | Single-Gas (CO₂) |
| Measurement Range | 0.01–5% vol CO₂ |
| Repeatability | ±2% FS (0.01–2.5% vol), ±3% FS (2.5–5% vol) |
| Resolution | 0.01% vol |
| Response Time (T90) | 20 s |
| Zero Drift | ≤±5% FS |
| Span Drift | ≤±1% FS |
| Linearity Error | ≤±2% FS |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| EMC Compliance | 2004/108/EC |
| Battery Life | 12 h (fully charged or with two AA alkaline batteries) |
| Acoustic Alarm | 95 dB @ 30 cm |
| Man-Down/Emergency Alarm | 110 dB @ 30 cm |
| Visual Indication | Tri-color LED status (green/yellow/red) |
| Display | High-contrast OLED |
| Data Logging | Internal storage with PC export capability |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida |
| Instrument Type | Portable |
| Detection Target | Single-Gas (CO₂) |
| Measurement Range | 0.01–5% vol CO₂ |
| Repeatability | ±2% FS (0.01–2.5% vol), ±3% FS (2.5–5% vol) |
| Resolution | 0.01% vol |
| Response Time (T90) | 20 s |
| Zero Drift | ≤±5% FS |
| Span Drift | ≤±1% FS |
| Linearity Error | ≤±2% FS |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| EMC Compliance | 2004/108/EC |
| Battery Life | 12 h (fully charged or with two AA batteries) |
| Audible Alarm | 95 dB @ 30 cm |
| Man-Down / Emergency Alarm | 110 dB @ 30 cm |
| Visual Indicators | Green (OK), Yellow (Fault), Triple Red (Alarm) |
| Alarm Configuration | Three user-set CO₂ concentration thresholds + one TWA alarm |
| Brand | ANALOX |
|---|---|
| Origin | United Kingdom |
| Model | HYP-MO2HBYY03 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Clark-type pO₂ sensor) |
| Range | 0–2 bar ppO₂ |
| Accuracy | ±1% of reading ±1 LSD |
| Temperature Effect | ±0.2% of reading / °C |
| Long-term Drift | ≤5% of reading per year |
| Zero Drift | <1% FS/year |
| Span Drift | <1% FS/year |
| Linearity Error | ±1% FS |
| Resolution | 0.01 bar ppO₂ |
| Repeatability | ±1% FS |
| Operating Temperature | 0–40 °C |
| Operating Pressure | 0.8–60 bar absolute (≈600 msw / 2000 fsw) |
| Compression/Decompression Rate Limit | <2 bar/min |
| Power Supply | 9 V PP3 battery |
| Battery Life | 800 h continuous operation |
| Dimensions | 64 × 98 × 36 mm |
| Weight | 0.200 kg |
| Sensor Module | Analox 9100-9212-5H |
| Optional Probe | 9100-9212-2 |
| Brand | ANALOX |
|---|---|
| Origin | United Kingdom |
| Model | HYP-MO2HBYY03 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Clark-type pO₂ sensor) |
| Range | 0–2 bar ppO₂ |
| Accuracy | ±1% of reading ±1 LSD |
| Temperature Effect | ±0.2% of reading / °C |
| Long-term Drift | ≤5% of reading per year |
| Zero Drift | <1% FS/year |
| Span Drift | <1% FS/year |
| Linearity Error | ±1% FS |
| Resolution | 0.01 bar ppO₂ |
| Repeatability | ±1% FS |
| Operating Temperature | 0–40 °C |
| Operating Pressure | 0.8–60 bar absolute (≈600 msw / 2000 fsw) |
| Response Time (t₉₀) | <15 s |
| Power Supply | 9 V PP3 battery |
| Battery Life | 800 h continuous operation |
| Dimensions | 64 × 98 × 36 mm |
| Weight | 0.200 kg |
| Sensor Model | Analox 9100-9212-5H |
| Optional Probe | 9100-9212-2 |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | SDA-CO2 |
| Sensor Range | 0–5000 ppm and 0–2% CO₂ |
| Accuracy | ±25 ppm or ±1% of reading (0–5000 ppm) |
| Display | Full-color graphical LCD |
| Output Options | 4–20 mA, relay, Ethernet (protocol available on request) |
| Data Logging | Optional internal memory |
| Alarm | Configurable audio/visual alerts via front panel |
| Compliance | DNV, IMCA, Lloyd’s Register, ABS, ADCI |
| Sensor Type | Dual-beam NDIR (Non-Dispersive Infrared) |
| Mounting | Rack-mountable or panel-mountable |
| Replacement Sensor | Advanced digital 5S3 NDIR sensor |
| Legacy Compatibility | Direct drop-in replacement for Analox 5001 |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | SDA-CO2 |
| Measurement Principle | Dual-Beam Non-Dispersive Infrared (NDIR) |
| Full-Scale Range | 0–5000 ppm / 0–2% CO₂ |
| Accuracy | ±25 ppm or ±1% of reading (0–5000 ppm) |
| Repeatability | ±1% of full scale |
| Resolution | 1 ppm (0–5000 ppm range) |
| Zero Drift | <±1% FS/month |
| Span Drift | <±1% FS/month |
| Linearity Error | ±1% of full scale |
| Display | High-brightness full-color TFT LCD |
| Output Options | 4–20 mA analog, relay outputs, Ethernet (Modbus TCP/IP configurable), optional data logging |
| Compliance | DNV GL OS-F101, IMCA D 018, Lloyds Register IR Class Rules, ABS Guide for Diving Systems, ADCI Consensus Standards |
| Sensor Type | Advanced digital 5S3 NDIR sensor |
| Mounting | Rack-mountable or panel-mountable |
| Enclosure Rating | IP65 front panel |
| Operating Temperature | 0–45 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH |
| Product Type | Laboratory TOC/TN Analyzer |
| Model | multi N/C ® Pharma UV |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Wet Oxidation |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | ±3% |
| Resolution | 0.001 ppb |
| Detection Limit | 2 ppb |
| Repeatability | <3% |
| Compliance | Designed for USP <643>, EP 2.2.44, JP 17, FDA 21 CFR Part 11, and GMP/GLP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Laboratory TOC/TN Analyzer |
| Model | multi N/C 2100 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Measurement Range | 0–60,000 ppm C or N |
| Accuracy | ≤ 3.0% RSD @ 100 mg/L TOC |
| Detection Limit | 50 ppb TOC |
| Resolution | 0.001 ppb |
| Repeatability | ≤ 2.0% RSD @ 100 mg/L TOC |
| Compliance | ASTM D7573, ISO 8245, USP <643>, EN 1484, EPA Method 415.3 & 9060A |
| Software | ASpect® TOC/TN Control & Data Management Suite (21 CFR Part 11 compliant) |