| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | ASPIDA |
| Instrument Type | Portable |
| Detection Target | Single-component (CO₂) |
| Measurement Range | 0.01–5.00% vol CO₂ |
| Resolution | 0.01% vol |
| Accuracy | ±2% FS (0.01–2.5% range), ±3% FS (2.5–5.0% range) |
| Response Time (T90) | <60 s |
| Zero Drift | <±1% FS/6 months |
| Span Drift | <±1% FS/6 months |
| Linearity Error | ≤1% FS |
| Operating Temperature | –5 to +50 °C |
| Battery | 2×2100 mAh NiMH AA |
| Runtime | >12 h per charge |
| Charging Time | 4.5 h |
| Display | High-visibility OLED |
| Audible Alarm | 95 dB @ 30 cm (110 dB for fall detection) |
| Visual Indicators | 1 green LED (normal), 1 yellow LED (fault), 3 red LEDs (alarm) |
| Sensor Technology | Non-dispersive infrared (NDIR), MIR-based |
| CO₂ Sensor Lifetime | 5 years |
| Optional O₂ Sensor | Electrochemical, 0.1–25.0% vol, T90 <30 s, lifetime 2 years |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | ASPIDA |
| Instrument Type | Portable |
| Detection Target | Single-Gas (CO₂) |
| Measurement Range | 0.01–5.00% vol CO₂ |
| Resolution | 0.01% vol |
| Accuracy | ±2% FS (0.01–2.5% range), ±3% FS (2.5–5.0% range) |
| Response Time (T90) | <60 s |
| Zero Drift | ±1% FS/6 months |
| Span Drift | ±1% FS/6 months |
| Linearity Error | ±1% FS |
| Operating Temperature | –5 to +50 °C |
| Battery | 2 × 2100 mAh NiMH AA |
| Runtime | >12 h (continuous) |
| Charging Time | 4.5 h |
| Display | High-visibility OLED |
| Alarm | 95 dB @ 30 cm (audible), tri-color LED indicators, fall detection alarm (110 dB) |
| Sensor Technology | Non-dispersive infrared (NDIR), MIR-based |
| CO₂ Sensor Lifetime | 5 years |
| Optional O₂ Sensor | Electrochemical, 0.1–25.0% vol, T90 <30 s, 2-year lifetime |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida |
| Instrument Type | Portable |
| Detection Target | Single-Gas (CO₂) |
| Measurement Range | 0.01–5% vol CO₂ |
| Repeatability | ±2% FS (0.01–2.5% vol), ±3% FS (2.5–5% vol) |
| Resolution | 0.01% vol |
| Response Time (T90) | 20 s |
| Zero Drift | ≤±5% FS |
| Span Drift | ≤±1% FS |
| Linearity Error | ≤±2% FS |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| EMC Compliance | 2004/108/EC |
| Battery Life | 12 h (fully charged or with two AA alkaline batteries) |
| Acoustic Alarm | 95 dB @ 30 cm |
| Man-Down/Emergency Alarm | 110 dB @ 30 cm |
| Visual Indication | Tri-color LED status (green/yellow/red) |
| Display | High-contrast OLED |
| Data Logging | Internal storage with PC export capability |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida |
| Instrument Type | Portable |
| Detection Target | Single-Gas (CO₂) |
| Measurement Range | 0.01–5% vol CO₂ |
| Repeatability | ±2% FS (0.01–2.5% vol), ±3% FS (2.5–5% vol) |
| Resolution | 0.01% vol |
| Response Time (T90) | 20 s |
| Zero Drift | ≤±5% FS |
| Span Drift | ≤±1% FS |
| Linearity Error | ≤±2% FS |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| EMC Compliance | 2004/108/EC |
| Battery Life | 12 h (fully charged or with two AA batteries) |
| Audible Alarm | 95 dB @ 30 cm |
| Man-Down / Emergency Alarm | 110 dB @ 30 cm |
| Visual Indicators | Green (OK), Yellow (Fault), Triple Red (Alarm) |
| Alarm Configuration | Three user-set CO₂ concentration thresholds + one TWA alarm |
| Brand | ANALOX |
|---|---|
| Origin | United Kingdom |
| Model | HYP-MO2HBYY03 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Clark-type pO₂ sensor) |
| Range | 0–2 bar ppO₂ |
| Accuracy | ±1% of reading ±1 LSD |
| Temperature Effect | ±0.2% of reading / °C |
| Long-term Drift | ≤5% of reading per year |
| Zero Drift | <1% FS/year |
| Span Drift | <1% FS/year |
| Linearity Error | ±1% FS |
| Resolution | 0.01 bar ppO₂ |
| Repeatability | ±1% FS |
| Operating Temperature | 0–40 °C |
| Operating Pressure | 0.8–60 bar absolute (≈600 msw / 2000 fsw) |
| Compression/Decompression Rate Limit | <2 bar/min |
| Power Supply | 9 V PP3 battery |
| Battery Life | 800 h continuous operation |
| Dimensions | 64 × 98 × 36 mm |
| Weight | 0.200 kg |
| Sensor Module | Analox 9100-9212-5H |
| Optional Probe | 9100-9212-2 |
| Brand | ANALOX |
|---|---|
| Origin | United Kingdom |
| Model | HYP-MO2HBYY03 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Clark-type pO₂ sensor) |
| Range | 0–2 bar ppO₂ |
| Accuracy | ±1% of reading ±1 LSD |
| Temperature Effect | ±0.2% of reading / °C |
| Long-term Drift | ≤5% of reading per year |
| Zero Drift | <1% FS/year |
| Span Drift | <1% FS/year |
| Linearity Error | ±1% FS |
| Resolution | 0.01 bar ppO₂ |
| Repeatability | ±1% FS |
| Operating Temperature | 0–40 °C |
| Operating Pressure | 0.8–60 bar absolute (≈600 msw / 2000 fsw) |
| Response Time (t₉₀) | <15 s |
| Power Supply | 9 V PP3 battery |
| Battery Life | 800 h continuous operation |
| Dimensions | 64 × 98 × 36 mm |
| Weight | 0.200 kg |
| Sensor Model | Analox 9100-9212-5H |
| Optional Probe | 9100-9212-2 |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | SDA-CO2 |
| Sensor Range | 0–5000 ppm and 0–2% CO₂ |
| Accuracy | ±25 ppm or ±1% of reading (0–5000 ppm) |
| Display | Full-color graphical LCD |
| Output Options | 4–20 mA, relay, Ethernet (protocol available on request) |
| Data Logging | Optional internal memory |
| Alarm | Configurable audio/visual alerts via front panel |
| Compliance | DNV, IMCA, Lloyd’s Register, ABS, ADCI |
| Sensor Type | Dual-beam NDIR (Non-Dispersive Infrared) |
| Mounting | Rack-mountable or panel-mountable |
| Replacement Sensor | Advanced digital 5S3 NDIR sensor |
| Legacy Compatibility | Direct drop-in replacement for Analox 5001 |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | SDA-CO2 |
| Measurement Principle | Dual-Beam Non-Dispersive Infrared (NDIR) |
| Full-Scale Range | 0–5000 ppm / 0–2% CO₂ |
| Accuracy | ±25 ppm or ±1% of reading (0–5000 ppm) |
| Repeatability | ±1% of full scale |
| Resolution | 1 ppm (0–5000 ppm range) |
| Zero Drift | <±1% FS/month |
| Span Drift | <±1% FS/month |
| Linearity Error | ±1% of full scale |
| Display | High-brightness full-color TFT LCD |
| Output Options | 4–20 mA analog, relay outputs, Ethernet (Modbus TCP/IP configurable), optional data logging |
| Compliance | DNV GL OS-F101, IMCA D 018, Lloyds Register IR Class Rules, ABS Guide for Diving Systems, ADCI Consensus Standards |
| Sensor Type | Advanced digital 5S3 NDIR sensor |
| Mounting | Rack-mountable or panel-mountable |
| Enclosure Rating | IP65 front panel |
| Operating Temperature | 0–45 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5010 N |
| Measurement Principle | High-Temperature Combustion Coupled with Chemiluminescence (N), UV-Fluorescence (S), and Microcoulometric Titration (Cl/Br) |
| Detection Limits | Sub-ppb for N and S in liquid/gas matrices |
| Analysis Time | 2–5 min per sample |
| Sample Types | Liquids, Gases, LPG, LNG, Solids (with optional solid module) |
| Automation | Unattended 24/7 operation with remote monitoring capability |
| Dimensions | < 0.3 m² footprint |
| Interface | Integrated 10.1" capacitive touchscreen with intuitive GUI |
| Detection Technology | HiPerSens™ optimized signal processing |
| Compliance | Designed to meet ISO 14852, ISO 14855, ASTM D5762, D7183, D7556, USP <381>, and EPA Method 524/525/5310C requirements |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5010 SMPO |
| Detection Principle | High-Temperature Combustion Coupled with UV Fluorescence Detection (S) / Chemiluminescence Detection (N) |
| Detection Limits | S: 5 ppb, N: 10 ppb |
| Linear Dynamic Range | 5 ppb – 50,000 ppm (S), auto-ranging |
| Sample Types | Liquid fuels (gasoline, diesel, jet fuel), LPG, LNG, refinery streams, crude oil fractions, aqueous extracts |
| Compliance | ASTM D5453, D7039, D7183, ISO 20846, ISO 20884, UOP 390, IP 520, SH/T 0689, GB/T 11141, EN 15486 |
| Automation | Optional 18-position or 120-position autosamplers |
| Software | EAsy Control v3.x with 21 CFR Part 11 compliance mode, audit trail, electronic signatures, method library, remote monitoring |
| Dimensions | < 0.3 m² footprint (integrated combustion unit, detector, controller, autosampler base) |
| Safety | EAsy Protect real-time system parameter monitoring, HiPerSens high-sensitivity detection module, glove-compatible nano-coated touchscreen |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH |
| Product Type | Laboratory TOC/TN Analyzer |
| Model | multi N/C ® Pharma UV |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Wet Oxidation |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | ±3% |
| Resolution | 0.001 ppb |
| Detection Limit | 2 ppb |
| Repeatability | <3% |
| Compliance | Designed for USP <643>, EP 2.2.44, JP 17, FDA 21 CFR Part 11, and GMP/GLP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Laboratory TOC/TN Analyzer |
| Model | multi N/C 2100 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Measurement Range | 0–60,000 ppm C or N |
| Accuracy | ≤ 3.0% RSD @ 100 mg/L TOC |
| Detection Limit | 50 ppb TOC |
| Resolution | 0.001 ppb |
| Repeatability | ≤ 2.0% RSD @ 100 mg/L TOC |
| Compliance | ASTM D7573, ISO 8245, USP <643>, EN 1484, EPA Method 415.3 & 9060A |
| Software | ASpect® TOC/TN Control & Data Management Suite (21 CFR Part 11 compliant) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi N/C 2100S / 3100 |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | High-Temperature Catalytic Combustion (up to 1000 °C) and Dual-Wavelength UV Oxidation (185/254 nm) |
| CO₂ Detection | Focused NDIR with Integrated Optics |
| TOC Range | 0–30,000 mg/L (without dilution) |
| Compliance | ASTM D7573, ISO 8245, USP <643>, EN 1484, EPA Method 415.3 & 9060A, DIN 38409-H3 |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi N/C 3100 |
| Instrument Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | 0–30,000 ppm C or N |
| Accuracy | ±2% of reading |
| Resolution | 0.001 ppb C |
| Detection Limit | 4 ppb C |
| Repeatability | ≤1% RSD |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Optional Oxidation | Dual-Wavelength High-Intensity UV Photolysis (for wet chemical oxidation) |
| Detection Modules | NDIR for TOC/TC/TIC/NPOC/POC |
| Sample Introduction | Ceramic Valve-Based Loop Injection System |
| Sample Compatibility | Suspended-solids-rich wastewater, high-salinity matrices, ultrapure water, and solid samples (with optional solid module) |
| Automation Level | Fully Modular, Configurable for Unattended Operation |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH |
| Country of Origin | Imported |
| Model | multi N/C Pharma HT |
| Instrument Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared Absorption (NDIR) for TOC |
| Oxidation Method | High-Temperature Catalytic Combustion at up to 1000 °C |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | <3% RSD |
| Detection Limit | 4 ppb C |
| Resolution | 0.001 ppb C |
| Repeatability | ±3% RSD |
| Compliance | Designed for GLP/GMP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi N/C UV HS |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | High-Energy UV/Persulfate Oxidation + NDIR CO₂ Detection |
| Measurement Range | 0–30,000 mg/L TOC |
| Detector | High-Focus NDIR |
| Oxidation | Dual-Wavelength UV (185 nm & 254 nm) + Optional Persulfate |
| Compliance | DIN EN 1484, DIN EN 12260, DIN EN 15936, ISO 20236, HJ 501-2009, HJ 695-2014, GB/T 5750.7-2006 |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH & Co. KG |
| Product Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Wet Oxidation |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | ±2% of reading |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.03 ppb – 10,000 ppm C |
| Repeatability | <1% RSD |
| Compliance | ASTM D5905, ISO 8245, USP <643>, EP 2.2.44, DIN 38409-H41 |
| Software | TOC-Control v4.x with 21 CFR Part 11 compliance options |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Country of Origin | Imported |
| Model | multi X 2500 |
| Price | Upon Request |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | multi N/C X300 |
| Instrument Type | Laboratory-based TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Measurement Range | 0–30,000 ppm C or N |
| Accuracy | ±2% of reading |
| Resolution | 0.001 ppb |
| Detection Limit | 4 ppb (as C) |
| Repeatability | ≤1% RSD |
| Nitrogen Detection | Chemiluminescence Detector (CLD) and Conductivity Detector (ChD) |
| Calibration | Single-Standard EasyCal™ Protocol |
| Flow Control | VITA™ Variable Intelligent Time-Adaptive Flow Regulation |
| Safety System | SCS™ Self-Checking Safety System |
| Software Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP data integrity protocols |
| Brand | Anasys |
|---|---|
| Origin | USA |
| Model | SMEC300 |
| Measurement Principles | Capacitive Volumetric Water Content (VWC), Four-Point Graphite Electrode EC, Precision Thermistor |
| Output | Analog Voltage (Time-Division Multiplexed) |
| VWC Range | 0–Saturation |
| VWC Resolution | 0.1% |
| VWC Accuracy | ±3% |
| EC Range | 0–10 mS/cm |
| EC Resolution | 0.01 mS/cm |
| EC Accuracy | ±2% |
| Temperature Range | −18 to +50 °C |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.8 °C |
| Sensing Volume | 6 cm × 2 cm |
| Cable Options | 1.8 m, 6 m, extendable to 15 m |
| Power | 3 V DC @ 6–10 mA |
| Brand | AND/A&D |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AND1000 |
| Instrument Type | Portable |
| Detection Principle | Fluorescence-based Photometric Assay |
| Target Analyte | Lead (Pb) |
| Analysis Time | < 60 seconds |
| Detection Limit | 2 ppb |
| Quantification Range | 2–100 ppb |
| Brand | ANDalyze |
|---|---|
| Origin | USA |
| Model | AND1100 |
| Measurement Principle | DNAzyme-based Fluorescence Detection |
| Detection Time | ≤60 s per sample |
| Detection Units | ppb or ppm |
| IP Rating | IP54 |
| Certifications | CE |
| Data Interface | USB |
| Software Update | Over-the-air via USB |
| Operating Languages | Multilingual (including Chinese) |
| Sensor Format | Discrete color-coded single-use cartridges |
| Sample Volume | 1 mL |
| Power | Rechargeable battery (USB charging) |
| Brand | ANDalyze |
|---|---|
| Origin | USA |
| Model | AND1100 |
| Detection Principle | DNAzyme-based Fluorescence Assay |
| Measurement Time | ≤60 s per sample |
| Detection Units | ppb or ppm |
| IP Rating | IP54 |
| Certifications | CE |
| Data Interface | USB |
| Software Updates | Over-the-air via USB |
| Operating Languages | English, Chinese, and others |
| Power | Rechargeable battery (USB charging) |
| Sample Volume | 1 mL |
| Sensor Format | Discrete, color-coded single-use cartridges |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-3150 Plus |
| Instrument Type | Laboratory Analyzer |
| Measurement Principle | Gas-Phase Chemiluminescence (GPC) with Onboard Oxidation |
| Measurement Range | 0.08–100 mg/L NH₃–N |
| Accuracy | ≤ ±5% of reading |
| Detection Limit | 0.02 mg/L NH₃–N |
| Analysis Time per Sample | 1–3 minutes |
| Batch Capacity | 80 samples |
| Air Supply | Integrated Clean Air Generator (Atmospheric Pressure, No High-Pressure Cylinders Required) |
| Onboard Functions | Integrated Oxidation Module, Heating Module (for Nitrate & Total Nitrogen), Homogenizing Sparging System, Refrigerated Water Trap, Sintered-Glass Gas–Liquid Separator, Real-Time Graphical Monitoring, Auto-Dilution (≥40×), Adjustable Lamp Current & Automatic Light Gain Control |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-5750 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Rapid Digestion Method (Closed-Tube, Reflux-Based) |
| Measurement Range | 16–700 mg/L COD |
| Accuracy | ≤5% (vs. Certified Reference Materials) |
| Repeatability | RSD ≤2.0% |
| Analysis Time | 14 minutes per sample |
| Batch Capacity | ≥21 samples |
| Safety Design | Fully Enclosed Digestion Chamber with Spherical Condenser |
| Operational Alert | Real-Time Reagent Vacuum Loss Detection |
| Compliance Context | Designed to support ISO 6060, ASTM D1252–06 (Method B), and HJ 828–2017 (Chinese EPA Standard) |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | AJ-600 |
| Pricing | Available Upon Request |
| Dispensing Volume Range | 50–1000 mL |
| Dispensing Accuracy | ≤ ±2% |
| Temperature Control Range | 4–60 °C |
| Temperature Stability | ±1 °C |
| Full-Volume Preparation Time | <15 min |
| Onboard Protocol Storage | ≥10 preloaded methods |
| Integrated Log System | Audit-trail-capable user activity logging |
| Touchscreen Interface | Color LCD with intuitive GUI |
| Built-in Functions | Automated stirring, temperature regulation, system self-cleaning, headspace liquid-path purging, method recall and execution |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-6400 |
| Target Analytes | Thallium (Tl), Lithium (Li) |
| Response Time | ≤2 min |
| Power Supply | Integrated Rechargeable Li-ion Battery (≥12 h continuous operation) |
| Operating Pressure | Ambient Atmospheric Pressure |
| Sample Introduction | Direct Liquid Injection (No Pretreatment Required) |
| Data Storage Capacity | >2000 Records with Real-time Spectral Display |
| Connectivity | USB for Data Export & Firmware Update |
| Compliance | Designed for Field Deployment under ISO/IEC 17025-aligned QA/QC Practices |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-6400A |
| Detection Target | Thallium (Tl) in aqueous samples |
| Response Time | ≤2 min |
| Power Supply | Integrated rechargeable lithium battery (≥12 h continuous operation) |
| Data Storage | >2000 measurement records with real-time spectral display |
| Interface | Touchscreen GUI, USB for data export & firmware update |
| Operating Environment | Ambient atmospheric pressure, no external gas supply or AC power required |
| Sample Handling | Direct liquid injection, no pretreatment |
| Calibration | Built-in standard curves + on-site curve generation capability |
| Remote Diagnostics | Supported |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ5700 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Rapid Digestion with Potassium Dichromate (Cr(VI)) Oxidation |
| Measurement Range | 0–700 mg/L COD<sub>cr</sub> |
| Accuracy | ≤5% (vs. certified reference materials) |
| Repeatability | RSD ≤2.0% |
| Cycle Time | <15 min per sample |
| Sample Capacity | ≥30 positions |
| Digestion Stations | ≥30 |
| Titration Stations | ≥2 |
| Reagent Dispensing Precision | ±0.2% |
| Safety Design | Negative-pressure enclosed chamber with fume containment |
| Waste Handling | Integrated废液 collection with overflow alarm |
| Connectivity | TCP/IP & Wi-Fi |
| Data Export Formats | PDF, Word, Excel, CSV, RTF, HTML |