Environmental Monitoring Instruments
Filter
Showing 1351–1380 of 2621 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GC-3010 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-3020 |
| Pricing | Upon Request |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GC955-615/815 |
| Detection Principle | Gas Chromatography with Dual FID/PID Detection |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Modular VOC Monitoring System |
| Detection Range | 0–300 ppb (user-selectable) |
| Detection Limit | 0.4 µg/m³ (trans-2-butene) |
| Repeatability | <3% RSD at 10 ppb (trans-2-butene) |
| Analysis Cycle | 30 minutes |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–95% RH |
| Power Supply | 220 VAC ±10% |
| Carrier Gas Flow Control | MFC (0–10 mL/min) |
| Preconcentrator Thermal Desorption Time | <10 s |
| Calibration | 5-point manual + automated sensitivity verification |
| Data Interface | Analog (4–20 mA) and digital (RS-485, Modbus TCP) compliant |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | GRTU-200-YG |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Original Equipment Manufacturer) |
| Model | HMA-2000 Series |
| Instrument Type | Online Analyzer |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Metals | Lead (Pb), Cadmium (Cd) |
| Detection Time | Zero Drift (24 h): ±5% F.S. |
| Resolution | 0.0001 mg/L |
| Sample Throughput | Continuous online operation with programmable measurement intervals |
| Reagent Consumption | <20% of conventional flow-injection ASV systems |
| Digestion | Sealed high-temperature high-pressure digestion module (up to 180 °C, 2 MPa) |
| Compliance | Designed for ISO 17294-2, EPA Method 200.8, and ASTM D3559–22 compatibility |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HMA-2000 |
| Instrument Type | Online Analytical System |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Metals | Pb, Cd, As, or Hg (configurable per unit) |
| Zero Drift | ±5% F.S. |
| Accuracy/Precision | ±10% |
| Resolution | 0.0001 mg/L |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | LAMPAS-3.0 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LDM-100 |
| Instrument Type | In-Situ Optical Transmissometer for Particulate Emissions Monitoring |
| Extinction Accuracy | ±0.004 |
| Repeatability | ≤2% |
| Response Time | 1–600 s (configurable) |
| Stability | Transmittance/Turbidity ±1% |
| Compliance | Meets GB/T 16157, HJ 76–2017, and HJ 836–2017 requirements for fixed-source emission monitoring |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | LGA-4500IC |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | In-Situ Online Analyzer |
| Technology | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Explosion Protection | Ex d IIB T4 Gb certified |
| Mounting | Flanged in-situ probe configuration |
| Compliance | Designed for industrial process environments per IEC 60079-0/-1/-28 and GB 3836 series |
| Target Gases | CO, CO₂, CH₄, NH₃, HCl, HF, O₂ (configurable via wavelength selection) |
| Operating Ambient Temperature | −20 °C to +60 °C |
| Process Temperature Range | Up to 1800 °C (probe-dependent) |
| Dust Load Tolerance | ≤100 g/m³ |
| Corrosion Resistance | Hastelloy C-276 probe housing standard |
| Power Supply | 24 VDC ±10% or 220 VAC 50/60 Hz |
| Output Interfaces | 4–20 mA analog, RS485 Modbus RTU, Ethernet TCP/IP, optional PROFIBUS DP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Methane / NMHC Online Analyzer |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Thermal Design | Full-Stream 175 °C High-Temperature Heating |
| Column Configuration | Dual-Valve Dual-Column (Model 115) / Dual-Valve Triple-Column (Model 120) |
| Analysis Cycle Time | <90 s per cycle |
| Target Analytes | CH₄, Total NMHC, Benzene, Toluene, Xylenes (BTX) |
| Safety Feature | Auto-H₂ shutoff upon FID flameout |
| Compliance Basis | Aligned with HJ 38–2017, HJ 1012–2018, EPA Method 25A, ASTM D6420 |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Ambient Air VOCs & Hydrocarbon Monitoring System |
| Measurement Principle | Dual-Channel GC-FID with Valve-Switched Cut-and-Backflush Separation |
| Detection Method | Flame Ionization Detection (FID) |
| Analyte Specificity | CH₄ and Total NMHC (C₂–C₁₂ hydrocarbons) |
| Carrier Gas | High-Purity Nitrogen or Helium |
| Hydrogen Fuel Gas | Ultra-High-Purity H₂ (99.999%) |
| Air for Combustion | Clean, Oil-Free Compressed Air |
| Flow Control | Electronic Pressure Control (EPC) and Electronic Flow Control (EFC) for Carrier, H₂, and Air |
| Safety Protocol | Auto-H₂-Shutoff upon Flame-Out Detection |
| Sample Introduction | Integrated Diaphragm Vacuum Pump with 1/8" PTFE-Lined Sampling Line |
| Quantitation Mode | External Standard Calibration with Certified Gas Mixtures |
| Data Output | RS485, Modbus TCP, 4–20 mA Analog Outputs |
| Environmental Operating Range | 5–40 °C, 20–90 % RH (non-condensing) |
| Power Supply | 220 VAC ±10 %, 50/60 Hz, 800 W Max |
| Enclosure Rating | IP54 Industrial Cabinet |
| Compliance | Meets CNEMC Guideline HJ 1012–2018, ASTM D6348–20, ISO 12010:2012 (for FID-based hydrocarbon analysis), GLP-Ready Data Logging |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MICROMAC C Series |
| Instrument Type | Online Water Quality Analyzer |
| Detection Principle | Colorimetric Analysis with Microprocessor Control |
| Analytical Technology | Loop Flow Analysis (LFA) |
| Key Feature | Auto-Dilution Function for Over-Range Measurement |
| Compliance Framework | Designed for Continuous Emission Monitoring Systems (CEMS) and Industrial Effluent Monitoring Applications |
| Software Interface | RS485/Modbus RTU, Optional 4–20 mA Analog Output |
| Enclosure Rating | IP65 |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Brand | FPI |
|---|---|
| Origin | Italy |
| Manufacturer | FPI |
| Type | Portable |
| Model | Micromac SmarTox |
| Operating Temperature | 4–6 °C (bacterial storage), 15 °C and 25 °C (reaction chambers) |
| Assay Time | 15 min |
| Compliance | ISO 11348-3, GB/T 15441 |
| Detection Principle | Bioluminescence inhibition of non-pathogenic marine bacteria |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Microwave Radiometer |
| Instrument Type | Other Weather Station |
| Operating Conditions | All-weather, automatic long-term operation (effective under light-to-moderate rain) |
| Measurement Capabilities | Tropospheric temperature profile, humidity profile, integrated water vapor (IWV), liquid water path (LWP), cloud base temperature & height, boundary-layer temperature profiling |
| Calibration | Real-time internal auto-calibration + periodic absolute calibration |
| Design | Modular architecture, RF interference immunity, lightning protection compliant, wind- and moisture-resistant enclosure |
| Remote Monitoring | Yes, with status telemetry and alarm notification |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MiniStation |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Mobile Emergency Atmospheric Monitoring Vehicle |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Mobile Water Emergency Monitoring Vehicle |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MAX-DOAS |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Original Equipment Manufacturer) |
| Instrument Type | Online Aerosol Organic Carbon/Elemental Carbon Analyzer |
| Measurement Principle | Thermal-Optical Transmittance (TOT) or Thermal-Optical Reflectance (TOR) |
| Compliance | Designed for ASTM D7520, IMPROVE_A, NIOSH 5040-compatible protocols |
| Sample Inlet | Standard PM2.5 or PM10 inlet with heated line (optional) |
| Detection Method | Laser transmittance/reflectance monitoring during thermal desorption |
| Flow Control | Proportional solenoid valves + mass flow controllers (MFCs) |
| Furnace Construction | High-purity alumina ceramic furnace bricks with ceramic fiber-insulated heating elements |
| OC/EC Split Point Determination | Automated optical carbon charring correction algorithm |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | OCEC-100 |
| Instrument Principle | Thermal-Optical Transmission/Reflection (TOT/TOR) |
| Configuration | Continuous Online Monitoring System |
| Compliance | Designed for ASTM D7520, IMPROVE_A, NIOSH 5040, EUSAAR-2 protocol alignment |
| Data Output | Real-time OC/EC mass concentration (µg/m³), split point identification, charring correction trace |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Online Analyzer |
| Optical Configuration | Dual-Station Open-Path FTIR |
| Spectral Resolution | 1 cm⁻¹ |
| Detector Operating Temperature | −196 °C (Liquid Nitrogen Cooled MCT) |
| Detection Limit | Sub-ppb for Selected Analytes |
| Spectral Library | >300 Reference Spectra (Validated Against Bruker and Anhui Institute of Optics and Fine Mechanics Libraries) |
| Gas Coverage | ≥20 Target Species Including VOCs, CO, CO₂, NH₃, SO₂, NO, HCl, HF, CH₄ (Customizable) |
| Sample Handling | Direct Ambient Air Measurement — No Pre-concentration, No Chemical Derivatization, No Sampling Line Required |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Continuous Emission Monitor |
| Detection Principle | Dual-Detector Gas Chromatography (GC-PID/GC-FID) |
| Sample Introduction | Stepper Motor-Driven Piston Sampling System with Temperature/Pressure Compensation |
| Preconcentration | Integrated Tenax TA or Cryo-Focused Trap with Thermal Desorption |
| Separation Architecture | Two-Dimensional GC (2D-GC) with Primary Pre-Separation Column and Analytical Capillary Column |
| Detector Configuration | Photoionization Detector (PID) + Flame Ionization Detector (FID) |
| Data Acquisition & Control | Embedded Industrial PC with Real-Time OS |
| Communication Interfaces | Ethernet, RS-232 (COM), USB, 4–20 mA Analog Output, Digital I/O |
| Compliance Support | Designed for EPA TO-15 / TO-17 alignment, compatible with ISO 8573-6 (hydrocarbon analysis in ambient air), supports audit-ready data logging per GLP/GMP principles |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | PAN |
| Pricing | Available Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PANs-1000 |
| Pricing | Available Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Model | PFS-100 |
| Type | Online Multicomponent Photolysis Rate Analyzer |
| Measurement Principle | Actinic Flux-Based Spectral Radiometry |
| Optical Path | Quartz Collector + UV-VIS Optical Fiber Coupling |
| Detector | Thermoelectrically Cooled CCD Array |
| Spectral Range | 280–450 nm (configurable) |
| Spectral Resolution | ≤0.5 nm (FWHM) |
| Calibration Traceability | NIST-traceable actinic flux calibration |
| Data Output | Real-time J-value time series (s⁻¹) for O¹D, NO₂, OH, HONO, HCHO, and other photolabile species |
| Compliance | Designed per ISO 17025 laboratory practice guidelines |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PMS-200 |
| Configuration | Dual-Channel Integrated Sampler |
| Flow Rate | Single-Channel: 16.67 L/min |
| Dual-Channel | 15 L/min (PM₂.₅) and 16.67 L/min (PM₁₀–PM₂.₅) |
| Vacuum Pressure Range | 80–106 kPa |
| Flow Stability | ≤2% of setpoint over 24 h |
| Maximum Flow Accuracy | ±2% of setpoint |
| Continuous Operation at Max Flow & Backpressure | 24 h |
| Service Life Under Max Load & Resistance | 2–3 years |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PMS-200A |
| Configuration | Integrated Low-Flow PM Sampler |
| Nominal Flow Rate | 16.67 L/min |
| PM10 & PM2.5 Fractionation | Equipped with ISO/EPA-compliant impactor or cyclonic PM2.5 separator |
| Filter Capacity | 16 pre-loaded filters per cassette |
| Automation | Pneumatically actuated filter exchange |
| Environmental Operating Range | -30 °C to +50 °C with active thermal regulation |
| Data Interface | RS-232, USB, and GPRS telemetry |
| Compliance | Designed to meet EPA Reference Method EQPM-0899-004, ISO 23270:2023 (Ambient air — Measurement of mass concentration of PM2.5 and PM10), and Chinese HJ 93-2013 technical specifications |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PMS-200M |
| Instrument Type | 24-Hour Temperature- and Flow-Controlled Ambient Air Sampler |
| Instrument Architecture | Multi-Channel Sequential Gas & Aerosol Sampler |
| Flow Range | Customizable (Typical Standard Range: 16.7–100 L/min per Channel) |
| Pressure Drop Handling | Up to 25 kPa (at max flow) |
| Flow Stability | ±2% over 24 h (with active feedback control) |
| Flowmeter Accuracy | ±1.5% of reading (NIST-traceable thermal mass flow sensors) |
| Rated Service Life at Max Load | ≥12,000 operating hours |
| Continuous Operation Duration at Max Flow & Backpressure | ≥24 h per cycle |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Pre-3000 + 315 VOC Online Analyzer |
| Product Category | Atmospheric VOC Online Monitoring System |
| Measurement Principle | Cryogenic Preconcentration Coupled with Capillary Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Detection Target | C2–C12 Volatile Organic Compounds (VOCs), including alcohols, ketones, esters, halogenated hydrocarbons, and aromatic compounds |
| Typical Detection Limit | Sub-ppbv (dependent on compound, integration time, and system configuration) |
| Water Removal Efficiency | >99% at −100 °C |
| Cryogenic Temperature Range | −100 °C to ambient |
| Thermal Desorption Rate | >40 °C/s (direct-resistive heating) |
| Carrier Gas Control | Electronic Pressure Control (EPC) and Electronic Flow Control (EFC) for H₂, air, and carrier gas (N₂ or He) |
| Enclosure | 19-inch rack-mount industrial chassis (standard 4U height) |