| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-120F(GK) |
| Sampling Flow Rate | 80–120 L/min |
| Maximum Negative Pressure | >26 kPa |
| Flow Stability | ≤±5% over 1 h |
| Flowmeter Accuracy | ≥±2.5% |
| Service Life at Max Flow & Backpressure | ≥5000 h |
| Continuous Operation Time at Max Flow & Max Resistance | 2–8 h with flow deviation ≤±5% |
| Instrument Type | Single-Channel Gas Sampler |
| Compliance | HJ/T 374–2007, HJ 93–2013, HJ 656–2013, HJ 657–2013, HJ 691–2014, HJ 480–2009, JJG 943–2011 |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-2 |
| Instrument Type | Flue Gas Sampler |
| Sample Medium | Flue Gas |
| Flow Accuracy | ±5% |
| Adjustable Sampling Flow Rate | 0.5–2.0 L/min |
| Pre-Flow Pressure Range | −30 to 0 kPa |
| Pre-Flow Temperature Range | −30 to +99 °C |
| Atmospheric Pressure Measurement Range | 70–130 kPa |
| Data Storage Capacity | 1000 sets |
| Operating Temperature | −30 to +50 °C |
| Dimensions (L×W×H) | 225 × 160 × 280 mm |
| Weight | ~3 kg |
| Power Supply | AC 220 V ±10%, 50 Hz or DC 12 V |
| Power Consumption | <20 W |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-7220 |
| Instrument Type | Online Continuous Monitor |
| Measurement Principle | Beta-Ray Absorption |
| Measured Parameters | PM₂.₅, PM₁₀, TSP |
| Measurement Range | PM₂.₅: 1–1000 µg/m³ |
| PM₁₀ | 1–10,000 µg/m³ |
| TSP | 0–10 mg/m³ |
| Sampling Flow Rate | 16.7 L/min |
| Detection Limit | 1 µg/m³ |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-7220 |
| Instrument Type | Online Continuous Monitor |
| Measurement Principle | Beta-Ray Absorption (⁴C Source) |
| Measured Parameters | TSP/PM₁₀/PM₂.₅ Mass Concentration, Wind Speed, Wind Direction, Ambient Temperature & Relative Humidity |
| Measurement Range | 0–10,000 µg/m³ |
| Sampling Flow Rate | 1.0 L/min |
| Detection Limit | 1 µg/m³ |
| Display Resolution | 0.1 µg/m³ |
| Accuracy | ≤ ±10% of reading |
| Repeatability | ≤ 10% RSD |
| Calibration Film Reproducibility | ≤ ±2% |
| Parallelism (inter-unit) | ≤ 15% |
| Sampling Method | Pump-Driven |
| Display | 7.0-inch Industrial Color Touchscreen |
| Dimensions (H×W×D) | 305 × 245 × 389 mm |
| Weight | ≤ 25 kg |
| Operating Humidity | 0–99% RH |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | ≤ 190 W |
| Data Transmission | 4G LTE Wireless |
| Ingress Protection | IP53 |
| Temperature & Humidity Compensation | Integrated DHS (Dry-Humid Stabilization) System |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-8000B |
| Instrument Type | Portable Automatic Water Sampler |
| Sampling Method | Quantitative Sampling |
| Single Sample Volume | 200–1000 mL (adjustable) |
| Sampling Volume Accuracy | ±1% |
| Pump Speed Range | 60–300 rpm (bidirectional) |
| Minimum Sampling Interval | 1 minute |
| Maximum Sampling Depth | 10 m |
| Power Supply | AC 220 V ±10%, 50/60 Hz (standard) |
| Power Consumption | <22 W |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <80% RH |
| Drive Unit Dimensions | 234 × 144 × 140 mm |
| Drive Unit Weight | 3 kg |
| Enclosure Rating | IP31 |
| Display | 3-digit LED (real-time speed) |
| Control Interface | Rotary pulse encoder |
| Memory Function | Power-loss data retention |
| Motor Type | Hybrid stepper motor |
| Pump Mechanism | High-reliability peristaltic pump |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-8101 |
| Rain Sensor Sensitivity | ≥0.03 mm/min |
| Lid Opening Time | ≤30 s |
| Lid Closing Time | ≤5 min |
| Measurable Rainfall Intensity Range | 0.03–4 mm/min |
| Measurement Accuracy | ±1% |
| Precipitation Collector Diameter | 300 mm |
| Dust Deposition Cylinder Height | 150 mm |
| Sampling Bucket Capacity | 15 L |
| Operating Temperature | 0–50 °C |
| Operating Relative Humidity | ≤98% RH |
| Dimensions (L×W×H) | 1200 × 550 × 1000 mm |
| Weight | ~40 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-8101 |
| Rainfall Detection Sensitivity | ≥0.03 mm/min |
| Lid Opening Response Time | ≤30 s |
| Lid Closing Response Time | ≤5 min |
| Measurable Rainfall Intensity Range | 0.03–4 mm/min |
| Measurement Accuracy | ±1% |
| Collection Funnel Diameter | 300 mm |
| Dust Deposition Cylinder Height | 150 mm |
| Sampling Bucket Capacity | 15 L |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤98% RH |
| Dimensions (L×W×H) | 1200 × 550 × 1000 mm |
| Weight | ~40 kg |
| Power Supply | AC 220 V (±10%), 50 Hz |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-JC |
| Material Options | Organic Glass / Borosilicate Glass / Ceramic |
| Internal Diameter | 15.0 ± 0.5 cm |
| Height | 30.0 cm |
| Base | Flat and Level |
| Internal Surface | Smooth, Non-Porous, Chemically Inert |
| Compliance | Designed to Fully Conform with HJ 1221–2021 “Determination of Total Dust Fall in Ambient Air — Gravimetric Method” |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-NS2112 |
| Primary Flow Rate | 12–120 L/min (±5% accuracy) |
| Concentration Flow Rate | 1.5–15 L/min (±5% accuracy) |
| Flow Repeatability | ±2% |
| Collection Efficiency | >90% for bioaerosol particles ≥3 µm |
| Cut-off Diameter (Da₅₀) | 1.1 µm at 100 L/min, 0.65 µm at 150 L/min, 0.43 µm at 200 L/min |
| Timer Range | 1 s – 99 h 59 min 59 s |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LB-Q102HB |
| Instrument Type | Portable |
| Detection Method | ISO 6703-2 / HJ 484–2009 (Isonicotinic Acid–Barbituric Acid Spectrophotometric Method) |
| Measurement Range | 0–1 mg/L CN⁻ |
| LOD | 0.004 mg/L |
| Measurement Time | 15–30 min |
| Accuracy | ±5% |
| Repeatability | ≤±5% |
| Optical Stability | ≤±0.001 A/20 min |
| Light Source | Imported Cold LED (100,000 h lifetime) |
| Cuvette Type | Integrated Digestion–Colorimetric Tube |
| Data Storage | 4,000 records + 96 customizable calibration curves |
| Connectivity | USB, LAN, Bluetooth (optional) |
| Display | Backlit LCD (Chinese/English switchable) |
| Power | Rechargeable 5000 mAh Li-ion battery (5 V, 0.3 W) |
| Dimensions | 240 × 95 × 80 mm |
| Weight | 0.5 kg |
| Operating Temp. | 5–40 °C |
| Operating Humidity | ≤85% RH (non-condensing) |
| Brand | Loobo |
|---|---|
| Model | LB-TR008 |
| Material | AISI 304 Stainless Steel |
| Sampling Depths | 1 m, 1.5 m, 2 m |
| Sample Length per Insertion | 15–20 cm |
| Depth Scale | Marked at 100 mm intervals |
| Weight | 5 kg |
| Configuration | Modular threaded assembly (bit, extension tube, handle) |
| Application | Field-based manual soil core sampling |
| Compliance | Designed for ISO 10381-1 (soil sampling principles), ASTM D1586 (standard penetration test reference geometry), and GLP-aligned sample integrity protocols |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-ZFB05 |
| Pricing | Available Upon Request |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-ZXF |
| Price Range | USD 1,400–4,200 (FOB) |
| Measurement Principle | Laser Light Scattering |
| Safety Classification | Non-Explosive Atmosphere Rated |
| Measurement Range | 0.001–10 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Accuracy | ≤5% FS |
| Relative Error | ≤±10% |
| Particle Size Selectivity | PM₂.₅, PM₁₀, and TSP (via electronic virtual impactor algorithm) |
| Operating Environment | Temperature –10°C to +50°C |
| Power Supply | Rechargeable Li-ion battery (12 h continuous operation) + AC/DC adapter |
| Communication Interfaces | RS232, RS485 (standard) |
| Data Storage | 100,000 records (timestamped, with real-time clock) |
| Display | Backlit LCD with Chinese/English bilingual interface |
| Dimensions | 400 × 300 × 170 mm |
| Weight | 1.0 kg |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | MD-1 |
| Measurement Principle | Stokes Sedimentation + Beer-Lambert Law |
| Particle Size Range | 0–150 µm |
| Resolution | 0.1 µm |
| Accuracy | ≤5% |
| Relative Error | ≤10% |
| Power Supply | 220 V AC |
| Dimensions | 430 × 285 × 300 mm |
| Weight | 15 kg |
| Data Storage Capacity | 40 particle size distribution profiles |
| Safety Classification | Non-explosion-proof |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | ET99700 |
| Stirring Positions | 4 |
| Speed Range | 10–150 rpm, continuously variable |
| Speed Accuracy | ±10 rpm |
| Operating Temperature | 10–45 °C |
| Power Supply | 220 V / 60 Hz |
| Dimensions | 230 × 245 × 325 mm |
| Weight | ~6.9 kg |
| Compliance | CE Marked |
| Standard Configuration | ET99700 unit, carrying case, user manual, warranty card (Chinese) |
| Note | 1500 mL low-temperature and high-temperature beakers (for ET99710) sold separately |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (PRC) |
| Model | LQ-5Z |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LQ-5Z-Multi |
| Pricing | Available Upon Request |
| Measurement Principle | Electrode-Based (Grab Sampling) |
| Measurement Range | TMAH: 0.00–5.0% / 0.0–50.0 g/L |
| NaOH | 0.00–3.00% / 0.0–30.0 g/L |
| Na₂CO₃ | 0.0–10.0% / 0–100 g/L |
| NH₃ | 0.0–2.00% / 0.0–20.0 g/L |
| H₂SO₄ | 0.0–2.00% / 0.0–20.0 g/L |
| HNO₃ | 0.0–2.00% / 0.0–20.0 g/L |
| Sample Temperature | 0.0–40.0 °C |
| Accuracy | ±5% FS |
| Calibration | Zero and Span Calibration |
| Temperature Compensation | Automatic |
| Enclosure Rating | IP66 |
| Power Supply | 3×AAA batteries with auto power-off |
| Electrode Type | 4C-type, 1 m standard cable |
| Dimensions (Instrument) | 75(W)×180(D)×38(H) mm |
| Electrode Dimensions | φ17×180(L) mm |
| Weight (Instrument) | ~300 g |
| Weight (Electrode) | ~50 g |
| Standard Kit | Analyzer with batteries, 4C electrode, user manual, certificate of conformity |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AKMC-1 |
| Price Range | USD 13,500 – 40,500 |
| Measurement Principle | Potentiometric Titration |
| Detection Range | 0.25–250 ppm (as CaCO₃) |
| Sampling Frequency | 1–4 times/hour |
| Operating Temperature | +10 to +35 °C |
| Relative Humidity (at +25 °C) | <80% |
| Sample Pressure | 0.1–10 atm |
| Sample Temperature | +5 to +40 °C |
| Power Supply | 110/220 VAC, 50/60 Hz |
| Power Consumption | 100 W |
| Dimensions | 300 × 400 × 150 mm |
| Weight | 20 kg |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | BA-15 |
| Detection Principle | Atomic Absorption Spectrometry with High-Frequency Zeeman Background Correction |
| Measurement Range | 0.1 ng/m³ – 10,000 mg/m³ |
| Response Time | 1 sec (real-time) – 5 min (integrated mode) |
| Zero Drift Compensation | Automatic |
| Sample Flow Rate | 7–10 L/min |
| Dimensions | 470 × 110 × 210 mm |
| Weight | 7 kg (15.4 lb) |
| Power Supply | 90–240 VAC, 50/60 Hz or 12 VDC |
| Power Consumption | 40 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | CRAB |
| Type | Online Oil Film Monitoring System |
| Measurement Range | 0–111 mg/L (as mineral oil, typical calibration) |
| Detection Limit | 0.2 mg/L |
| Accuracy | ±1 mg/L |
| Resolution | 0.1 mg/L |
| Measurement Frequency | 1 Hz |
| Minimum Detectable Oil Film Thickness | ≥0.5 µm |
| Maximum Sensor-to-Water Distance | 25 m |
| Maximum Communication Distance (RS485) | 300 m |
| Operating Temperature | −10 to +50 °C |
| Relative Humidity | Up to 100% |
| Power Supply | 187–242 VAC, 50 Hz |
| Power Consumption | 20 W |
| Dimensions | 160 × 160 × 110 mm |
| Weight | 2 kg |
| Optical Field Tilt Tolerance | ±20° |
| Communication Interfaces | RS232, RS485 |
| Alarm Output | Relay + Visual/Audible Alert |
| Mounting Options | Fixed, pendant, angled, or UAV-integrated |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | FLUORAT-02 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Methods | Fluorometry, Photometry, Chemiluminescence |
| Measured Parameters | Oil in Water, Volatile Phenols, Anionic Surfactants, COD, Turbidity, Cyanide, Uranium, Vanadium, Molybdenum, Nickel, Manganese, Chromium |
| Spectral Range | 250–900 nm |
| Cuvette Pathlengths | 10, 20, and 40 mm |
| Power Supply | 200–240 VAC, 50 Hz |
| Dimensions | 305 × 320 × 110 mm |
| Weight | 6.5 kg |
| Power Consumption | 36 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-02-5M |
| Instrument Type | Portable |
| Measurement Principle | UV Spectrophotometry & Fluorescence Detection |
| Detection Limit | 0.2 mg/L |
| Accuracy | ±1% |
| Resolution | 0.01 mg/L |
| Measurement Frequency | 2 samples/min |
| Spectral Range | 250–900 nm |
| Cuvette Pathlengths | 10, 20, and 40 mm |
| Power Supply | 200–240 VAC, 50 Hz |
| Dimensions | 305 × 320 × 110 mm |
| Weight | 6.5 kg |
| Power Consumption | 36 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-AE-2 |
| Instrument Type | Online |
| Measurement Principle | UV Fluorescence with Patented Signal Separation Technology |
| Measurement Range | 0.001–500 mg/L |
| Detection Limit | 0.01 mg/L |
| Accuracy | <2% |
| Resolution | 0.1 mg/L |
| Measurement Frequency | 8 samples/hour |
| Sample Input | Up to 10 parallel aqueous streams |
| Power Supply | 187–242 VAC, 50 ±1 Hz / 12 VDC |
| Power Consumption | 100 W |
| Dimensions | 500 × 660 × 200 mm |
| Weight | 50 kg |
| Brand | LUMEX |
|---|---|
| Model | FLUORAT® AA-2 |
| Origin | Russia |
| Detection Range | 0.04–2 mg/L Al |
| Operating Temperature | +5 to +50 °C |
| Sample Flow Pressure | 0.1–10 atm |
| Cycle Time | 10–30 min |
| Output Interfaces | RS-485, RS-232, 4–20 mA (0–20 mA) |
| Power Supply | 187–242 V, 50 Hz ±1%, 12 V DC |
| Power Consumption | 100 W |
| Dimensions | 600 × 600 × 250 mm |
| Weight | ≤ 50 kg |
| MTBF | ≥ 10,000 h |
| IP Rating | Dust-protected and splash-resistant |
| Compliance | PND F 14.1:2.4.181-02, PND F 14.1:4.1.1255-03 |
| Brand | LUMEX |
|---|---|
| Origin | USA |
| Model | IRM-915 |
| Detection Principle | Zeeman-effect Background-Corrected Cold Vapor Atomic Absorption Spectrometry (CVAAS) with High-Temperature Dry Catalytic Conversion |
| Measurement Range | 0.05–1000 µg/m³ (wet basis, HgT and Hg⁰) |
| Zero Drift | ±2.5% |
| Precision | ±2.5% |
| Accuracy | ±5% |
| Conversion Temperature | 700–750 °C |
| Dilution Ratio | Up to 1:100 |
| Sample Flow | Heated probe + heated filter + dilution/conversion module |
| Power Requirement | 220 V, 1000 W |
| Compressed Air | 15–20 L/min at 80 psig |
| Data Output | Real-time acquisition |
| System Weight | 67 kg |
| Brand | LUMEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | OLM30B Sampler |
| Sampling Flow Rate | 1 L/min |
| Flow Accuracy | ±1% of full scale |
| Sampling Temperature | Up to 150 °C |
| Sample Target | Elemental and Oxidized Mercury (Hg⁰, Hg²⁺) |
| Flow Resolution | 0.01 L/min |
| Repeatability | ±1% FS |
| Max Flow Rate | 2 L/min |
| Power Supply | 110/220 V AC |
| Power Consumption | 500 W |
| Operating Temperature Range | –10 °C to 50 °C |
| Weight | Air Pump Unit 6.8 kg, Probe 14 kg |
| Compliance | EPA Method 30B, 40 CFR Part 60, ASTM D6784-22 |
| Brand | LUMEX |
|---|---|
| Origin | USA |
| Model | OLM915J |
| Detection Principle | High-Temperature Catalytic Conversion + Zeeman-Background-Corrected Atomic Absorption Spectrometry (AAS) |
| Measurement Range | 0.1–100 µg/m³ |
| Response Time | ≤30 seconds per reading |
| Compliance | EPA Method PS 12A (Level 3 Certified) |
| Sample Handling | Hot-wet extraction with heated sampling probe (10–50 ft customizable), Ni-based alloy filter/dilution module, dry catalytic conversion at 750 °C |
| Enclosure Rating | NEMA 4X |
| Operating Ambient Temperature | –10 to 50 °C |
| Power Requirement | 110/220 VAC, 2000 W |
| Compressed Air Supply | Dry, dew point ≤ –40 °C |
| Calibration | Integrated elemental Hg vapor generator, fully automated, no external standards required |
| Data Output | Real-time Ethernet (Modbus TCP/IP, OPC UA), Excel export via embedded industrial PC, ESC8832-compatible |
| Brand | LUMEX |
|---|---|
| Model | RA-915WM |
| Principle | High-Temperature Thermal Decomposition Coupled with Zeeman Atomic Absorption Detection |
| Detection Limit | 0.3 µg/L |
| Measurement Range | 0–200 µg/L |
| Analysis Frequency | Once every 0.5–3 hours |
| Calibration | Fully Automatic |
| Baseline Verification | Fully Automatic |
| Max. Dissolved Solids Tolerance | 1000 mg/L |
| Communication Interfaces | RS-232/485, LAN, Isolated 4–20 mA |
| Protocols | Modbus, GESYTEC |
| Output Relays | Open/Closed |
| Operating Temperature | 5–40 °C |
| Atmospheric Pressure Range | 84–106.7 kPa |
| Relative Humidity | <98% at +35 °C |
| Power Supply | 110/240 VAC, 50/60 Hz |
| Dimensions (L×W×H) | 1000 × 400 × 2000 mm |
| Brand | LINGXI Optoelectronics |
|---|---|
| Model | LXEC-210 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Gases | CO₂, H₂O |
| Origin | Zhejiang, China |
| Gas Detection Configuration | Open-path, in-situ |
| Power Consumption | Low-power design, no pump required |
| Compliance Context | Designed for field-deployable eddy covariance (EC) flux measurements per AmeriFlux/ICOS protocols |
| Sample Interface | Direct atmospheric sampling, no inlet tubing or sample cell |
| Brand | LINGXI Optoelectronics |
|---|---|
| Origin | Zhejiang, China |
| Model | LXEC-210C |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Measured Gases | CO₂ and H₂O |
| Gas Path Configuration | Closed-Path |
| Compliance Context | Designed for long-term eddy covariance flux measurements per AmeriFlux/ICOS protocols |
| Data Integrity Features | Automated zero calibration, temperature-stabilized optical bench, high-frequency sampling (up to 20 Hz) |
| Environmental Robustness | IP65-rated enclosure, -25 °C to +50 °C operating range, condensation-resistant sample line heating |