| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 5010 |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 5100 |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 5240 Series |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 6010 |
| Quotation | Upon Request |
| Instrument Type | Online Analyzer |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) |
| Target Elements | Multi-Element (e.g., As, Cd, Cr, Cu, Ni, Pb, Zn, Hg, Mn, Fe, Al, etc.) |
| Compliance Standard | HJ 776–2015 “Determination of 32 Elements in Water by ICP-OES” |
| Automation Level | Fully Automated (Sampling, Filtration, Pre-treatment, Analysis, QC, Data Acquisition & Transmission) |
| Detection Range | Sub-ppb to ppm (full dynamic range) |
| Measurement Cycle | < 5 minutes per sample (multi-element simultaneous analysis) |
| Interference Resistance | Immune to color, turbidity, and matrix-induced spectral overlap under optimized plasma conditions |
| Waste Generation | Minimal reagent consumption |
| Brand | EXPEC / SUPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 8020 |
| Pricing | Available Upon Request |
| Brand | EXPEC (Pubichem) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TRACE 8000 |
| Instrument Type | Online VOC Analyzer |
| Ion Source | Dual-Anode Hollow Cathode Lamp with H₂O Reagent Ion Chemistry |
| Mass Analyzer | Vertical-Entry Reflectron Time-of-Flight (TOF) |
| Detection Mode | Soft Chemical Ionization (PCI) via H₃O⁺ Transfer |
| Typical LOD | <100 pptv (sub-ppb) for C₂–C₁₀ VOCs |
| Operating Mode | Unattended Continuous Monitoring |
| Compliance Framework | Designed for ISO 16000-22, ASTM D6196-20, and EPA Method TO-15/TO-17 compatible workflows |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | WOT-3100 |
| Application | Organic Contaminant Source Identification via Fluorescence Excitation-Emission Matrix (EEM) Fingerprinting |
| Detection Principle | UV-Vis Fluorescence Spectroscopy (200–450 nm excitation |
| Operational Mode | Reagent-Free, Non-Destructive Optical Analysis |
| Deployment Flexibility | Benchtop, Mobile (Vehicle/Boat-Mounted), Field-Deployable |
| Data Integration Capability | Compatible with Heavy Metal Analyzers and Organic Pollutant Sensors for Multi-Parameter Emergency Response |
| Brand | ExStik |
|---|---|
| Origin | Shanghai, China |
| Model | CL200 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Amperometric Sensor |
| Measured Parameter | Total Residual Chlorine |
| Range | 0.01–10.00 ppm |
| Accuracy | ±10% of reading or ±0.01 ppm (0.05–5.00 ppm) |
| Repeatability | ±0.01 ppm |
| Resolution | 0.01 ppm |
| LOD | 0.05 ppm |
| Temperature Range | −5 to 90 °C |
| Temp. Resolution | 0.1 °C/°F |
| Temp. Accuracy | ±1 °C (−5 to 50 °C) |
| Data Storage | 15 readings |
| Power | 4 × CR2032 (1.5 V) |
| Auto-off | After 10 min idle |
| IP Rating | IP57 |
| Brand | ExStik |
|---|---|
| Origin | Shanghai, China |
| Model | CL200+ |
| Measurement Principle | Amperometric Electrode with Solid-State Platinum/Graphite Composite Sensor |
| Range | 0.01–10.00 ppm (Total/Free Chlorine) |
| Accuracy | ±10% of reading ±0.01 ppm (0.05–5.00 ppm) |
| Temperature Compensation | Automatic (–5 to 90 °C) |
| Temp. Accuracy | ±1 °C (–5 to 50 °C), ±3 °C (50 to 90 °C) |
| Display | Multi-segment LCD with bar graph |
| Data Storage | 15 readings |
| Power | 4 × SR-44 (1.5 V) button cells |
| Auto-off | After 10 min idle |
| Electrode Compatibility | Interchangeable residual chlorine, pH, and ORP sensors with auto-detection |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YKC Series |
| Pricing | Upon Request |
| Output Options | Analog (4–20 mA / 0–10 V) and Digital (RS485 Modbus RTU, factory-configurable) |
| Maximum Stroke | 2540 mm (100 in) |
| Body Diameter × Length | 89 mm × 89 mm |
| Weight | 907 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FabGuard™ Sensor Integration and Analysis System |
| Pricing | Available Upon Request |
| Brand | Fangyuan Scientific Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FY2700-00 |
| Detection Limits | α: 3–10 MeV |
| β | 0–5 MeV |
| Stability | Count rate drift < 0.2% over 24 h |
| Resolution | 0.01 (channel width in keV per channel, typical for digital pulse-height analysis) |
| Brand | Fangyuan Scientific Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | FY3104-00 |
| Instrument Type | Laboratory Alpha Spectrometer |
| Measurement Medium | Solid Samples |
| Detector Interface | Compatible with Commercial PIPS Detectors (International & Domestic) |
| Radiation Type | Alpha Particles |
| Sensitivity | 0.01 cpm (counts per minute) in 3–10 MeV range |
| Energy Range | 3–10 MeV |
| Background Count Rate | <1 count/hour (3–10 MeV) |
| Energy Resolution | FWHM ≤18 keV at 5.486 MeV (with 300 mm² PIPS detector, source-to-detector distance = detector diameter) |
| Multichannel Scaling | 512 / 1024 / 2048 / 4096 channels (software-selectable) |
| Bias Voltage | 0–180 V (digital, 0.2 V resolution) |
| Leakage Current Monitoring | –3 to +150 nA (accuracy <1 nA) |
| Vacuum Control | Adjustable vacuum hold, pump-down, and vent modes |
| Sample Chamber | Recoil suppression design |
| Sample Stage | Manually adjustable vertical positioning (4 mm resolution) |
| Detector Active Area | 300–1200 mm² |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 10–80 % RH |
| Communication Interfaces | USB, RS-232, Ethernet, Wi-Fi |
| Software | AlphaSense — spectral acquisition, energy/efficiency calibration, nuclide library (built-in + user-defined), peak deconvolution, and GLP-compliant data logging |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–19.999 pX |
| Resolution | 0.001/0.01/0.1 pX (adjustable) |
| mV Range | −1999.9 to +1999.9 mV |
| mV Resolution | 0.1/1 mV (adjustable) |
| Temperature Range | −5.0 to +105.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C ±1 digit |
| pX Accuracy | ±0.005 pX ±1 digit |
| mV Accuracy | ±0.03% FS ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration Points | Up to 2-point auto-identification |
| Response Time | ≤3 s |
| Temperature Compensation | Automatic or Manual (−5.0 to +105.0 °C) |
| Data Output | RS232 serial interface |
| Electrode Interface | Universal BNC + temperature sensor port |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C Fluoride Ion Meter |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–19.999 pX |
| Resolution | 0.001/0.01/0.1 pX (adjustable) |
| Accuracy | ±0.005 pX ±1 digit |
| mV Range | −1999.9 to +1999.9 mV |
| mV Resolution | 0.1/1 mV (adjustable) |
| mV Accuracy | ±0.03% FS ±1 digit |
| Temperature Range | −5.0 to +105.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C ±1 digit |
| Temperature Compensation | Automatic or Manual (−5.0 to +105.0 °C) |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration Points | Up to 2-point |
| Response Time | ≤3 s |
| Electrode Interface | BNC + RTD (Pt1000 or thermistor) |
| Communication Interface | RS232 |
| Data Storage | Internal calibration history and measurement logs |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Certifications | ISO 9001 certified |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PXJ-1C+ Ammonia-Sensitive Ion Meter |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99999 ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0 to 135.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Data Storage Capacity | 4096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| pH Range | −10.000 to 20.000 |
| pH Resolution | 0.001/0.01/0.1 pH (selectable) |
| pH Accuracy | ±0.002 pH ±1 digit |
| mV Range | −2000.00 to 2000.00 mV |
| mV Resolution | 0.01/0.1/1 mV (selectable) |
| mV Accuracy | ±0.02% FS ±1 digit |
| Units Supported | pX, ppm, ppb, ppt, mol/L, mmol/L, µmol/L, nmol/L, %, µg/L, mg/L, g/L, ng/L |
| Interface | BNC electrode port, Pt1000/NTC temperature input, USB, RS232, 0–20 mV analog output |
| Power Supply | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ Ammonium Ion Meter |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99,999 ppm |
| Detection Limit | 9,999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0–135.0 °C |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Input Impedance | ≥3 × 10¹² Ω |
| Data Storage Capacity | 4,096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Temperature Compensation | Automatic (ATC) or Manual |
| Communication Interfaces | USB, RS-232, 0–20 mV analog output |
| Power Supply | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99999 ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0–135.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3×10¹² Ω |
| Data Storage Capacity | 4096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Supported Units | pX, ppm, ppb, ppt, mol/L, mmol/L, µmol/L, nmol/L, %, µg/L, mg/L, g/L, ng/L |
| Interface | BNC electrode port, Pt1000/NTC temperature input, USB, RS232, 0–20 mV analog output |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PXJ-1C+ |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99999 ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Resolution | 0.001 (pH), 0.01 mV |
| Temperature Range | −20.0 to 135.0 °C |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Model | PXJ-1C+ Borate Ion Analyzer |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0–99,999 ppm |
| Detection Limit | 9,999 ppm |
| Response Time | 3 s |
| Measurement Resolution | 0.001 |
| Temperature Range | −20.0–135.0 °C |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ Bromide Ion Analyzer |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99,999 ppm |
| Detection Limit | 9,999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0 to 135.0 °C |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Input Impedance | ≥3 × 10¹² Ω |
| Data Storage Capacity | 4,096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Supported Units | pX, ppm, ppb, ppt, mol/L, mmol/L, µmol/L, nmol/L, %, µg/L, mg/L, g/L, ng/L |
| Temperature Compensation | Automatic (ATC) or Manual |
| Interface | BNC electrode port, Pt1000/NTC temperature input, USB, RS-232, 0–20 mV analog output |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99,999 ppm |
| Detection Limit | 9,999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0 to 135.0 °C |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Data Storage Capacity | 4,096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Supported Units | pX, ppm, ppb, ppt, mol/L, mmol/L, µmol/L, nmol/L, %, µg/L, mg/L, g/L, ng/L |
| Temperature Compensation | Automatic (ATC) or Manual |
| Input Impedance | ≥3 × 10¹² Ω |
| Interface | BNC electrode port, Pt1000/NTC temperature input, USB, RS232, 0–20 mV analog output |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ CO₂ Ion Analyzer |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99,999 ppm |
| Detection Limit | 9,999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0 to 135.0 °C |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Input Impedance | ≥3 × 10¹² Ω |
| Data Storage | 4,096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Temperature Compensation | Automatic (ATC) or Manual |
| Communication Interfaces | USB, RS-232, 0–20 mV analog output |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ Chloride Ion Analyzer |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99999 ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0–135.0 °C |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Data Storage Capacity | 4096 records |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Compliance | GLP-compliant |
| Interface | USB, RS-232, 0–20 mV analog output |
| Input Impedance | ≥3×10¹² Ω |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ Cyanide Ion Analyzer |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99,999 ppm |
| Detection Limit | 9,999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0 to 135.0 °C |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Data Storage | 4096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Input Impedance | ≥3 × 10¹² Ω |
| Interfaces | BNC electrode port, Pt1000/NTC temperature input, USB, RS-232, 0–20 mV analog output |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99999 ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0 to 135.0 °C |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Data Storage Capacity | 4096 records |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Supported Units | pX, ppm, ppb, ppt, mol/L, mmol/L, µmol/L, nmol/L, %, µg/L, mg/L, g/L, ng/L |
| Temperature Compensation | Automatic (ATC) or Manual |
| Input Impedance | ≥3 × 10¹² Ω |
| Interface | BNC electrode port, Pt1000/NTC temperature input, USB, RS232, 0–20 mV analog output |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99,999 ppm |
| Detection Limit | 9,999 ppm |
| Response Time | 3 s |
| Measurement Resolution | 0.001 (pH), 0.01 mV, 1–3 significant digits (ion concentration) |
| Temperature Range | −20.0 to 135.0 °C |
| Temperature Resolution | 0.1 °C |
| Input Impedance | ≥3 × 10¹² Ω |
| Data Storage Capacity | 4,096 sets |
| Calibration Points | 2–9-point ion calibration |
| GLP Compliance | Yes |
| Communication Interfaces | USB, RS-232, 0–20 mV analog output |
| Power Supply | DC 9 V / 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ |
| Instrument Type | Benchtop |
| Ion Measurement Range | (0–99999) ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Resolution | 0.001 |
| Temperature Range | (−20.0–135.0) °C |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ Nitrate Ion Meter |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99999 ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Resolution | 0.001 (pH), 0.01 mV |
| Temperature Range | −20.0 to 135.0 °C |
| Data Storage Capacity | 4096 sets |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Input Impedance | ≥3 × 10¹² Ω |
| Compliance | GLP-compliant |
| Connectivity | USB, RS-232, 0–20 mV analog output |
| Power Supply | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99999 ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0 to 135.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Data Storage Capacity | 4096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Supported Units | pX, ppm, ppb, ppt, mol/L, mmol/L, µmol/L, nmol/L, %, µg/L, mg/L, g/L, ng/L |
| pH Range | −10.000 to 20.000 |
| pH Resolution | 0.001/0.01/0.1 (selectable) |
| pH Accuracy | ±0.002 pH ±1 digit |
| mV Range | −2000.00 to 2000.00 mV |
| mV Resolution | 0.01/0.1/1 mV (selectable) |
| mV Accuracy | ±0.02% FS ±1 digit |
| Interface | BNC electrode port, Pt1000 temperature input, USB, RS232, 0–20 mV analog output |