Environmental Monitoring Instruments
Filter
Showing 2011–2040 of 9029 results
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ Silver/Sulfide Ion Analyzer |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99999 ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0–135.0 °C |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Input Impedance | ≥3×10¹² Ω |
| Data Storage | 4096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), ≤5 points (pH) |
| Temperature Compensation | Automatic (ATC) or Manual |
| Communication Interfaces | USB, RS-232, 0–20 mV analog output |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ |
| Instrument Type | Benchtop |
| Ion Measurement Range | (0–99999) ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | (−20.0–135.0) °C |
| pH Resolution | 0.001 pH |
| mV Resolution | 0.01 mV |
| Input Impedance | ≥3×10¹² Ω |
| Data Storage Capacity | 4096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Temperature Compensation | Automatic (ATC) or Manual |
| Communication Interfaces | USB, RS-232, 0–20 mV analog output |
| Brand | Chelsea |
|---|---|
| Origin | UK |
| Model | FastBallast |
| Detection Principle | Single-Turnover Active Fluorescence (STAF) |
| Measurement Range | 10–50 µm |
| Sensitivity | <1 cell/mL |
| Dynamic Range | 0–4000 cells/mL |
| Sample Volume | 20 mL |
| Analyzed Volume | 0.5 mL |
| Test Duration | <2 min (Level 1), <10 min (Level 2) |
| Dimensions | 273 × 246 × 122 mm |
| Weight | 4.5 kg |
| IP Rating (lid closed) | IP68 |
| Battery Life | 8 h continuous operation |
| Connectivity | Bluetooth / USB |
| Warranty | 1 year |
| Brand | Chelsea |
|---|---|
| Origin | United Kingdom |
| Model | FastOcean APD |
| Excitation Wavelengths | 450 nm, 530 nm, 624 nm |
| Measurement Principle | Multi-wavelength Fast Repetition Rate Fluorometry (FRRf) |
| Sampling Frequency | 10 Hz |
| Dark Adaptation Duration | 2 s |
| Power Supply | Programmable Battery Pack |
| Software Platform | FastPro8 v8.x |
| Compliance | Designed for GLP-aligned marine biogeochemical field studies |
| Sample Environment | In situ seawater profiling (0–1000 m typical), laboratory cuvette mode supported |
| Interoperability | Compatible with FastAct actinometer system and third-party CTD/rosette platforms |
| Brand | 4DigitalBooks |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FastOcean APD |
| Instrument Type | In Situ Algal Fluorometer |
| Measurement Principle | Fast Repetition Rate (FRR) Fluorescence |
| Excitation Wavelengths | 450 nm, 530 nm, 624 nm |
| Depth Rating | 600 m |
| Operating Voltage | 18–36 V DC |
| Power Consumption | 4.8 W (peak 5 W) |
| Battery Life | 6 hours continuous operation |
| Sampling Frequency | 10 Hz |
| Fluorescence Signal Range | Equivalent to Chl-a concentration 0.02–200 mg/m³ |
| LED Irradiance Units | photons·m⁻²·s⁻¹ × 10²² |
| Software Platform | FastPro8 v3.2+ |
| Compliance | CE, RoHS, IP68 submersible housing |
| Data Output | ASCII, CSV, NetCDF |
| Interface | RS-232/RS-485, optional Ethernet/WiFi module |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FC-1A |
| Pricing | Available Upon Request |
| Flow Range | 3–30 L/min |
| Negative Pressure | >2500 Pa |
| Flowmeter Accuracy | Class 2.5 |
| Timer Range | 0–99 min (±0.1% error) |
| Battery Runtime | >3 h (Ni-Cd, 9.6 V / 4.5 Ah) |
| Operating Temp. | 0–40 °C |
| Relative Humidity | <95% RH |
| Power Consumption | <1.0 A |
| Dimensions (H×W×D) | 230 × 135 × 110 mm |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FC-4 |
| Pricing | Available Upon Request |
| Flow Range | 3–25 L/min (dual-channel, continuously adjustable) |
| Vacuum Pressure | >2500 Pa |
| Flowmeter Accuracy | Class 2.5 |
| Timer Range | 0–99 min (timing error ≤0.1%) |
| Battery Runtime | >3 hours (continuous operation) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <95% RH |
| Power Supply | 9.6 V / 4.5 Ah Ni-Cd rechargeable battery |
| Operating Current | <1.2 A |
| Dimensions (H×W×D) | 230 × 140 × 140 mm |
| Standard Kit Includes | 1× main unit, 2× sampling heads, 2× filter cassettes, 2× boxes of standard 37-mm or 25-mm membrane filters (e.g., PVC, mixed cellulose ester), 1× AC adapter cable, 1× tripod mount, 1× user manual, 1× certificate of conformity, 1× aluminum carrying case |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FCC-25 |
| Pricing | Upon Request |
| Sampling Flow Rate | 20 L/min |
| Maximum Vacuum Pressure | >3000 Pa |
| Load Capacity | ≥1000 Pa |
| Dust Fraction Collection | Total Dust & Respirable Dust |
| Timer Range | 0–99 min (adjustable) |
| Continuous Operation Time | >120 min |
| Sound Pressure Level | ≤70 dB(A) |
| Explosion Protection | Intrinsic Safety ibI (150 °C) |
| Operating Temperature | −5 to 35 °C |
| Relative Humidity Limit | ≤95% RH |
| Dimensions | 200 × 140 × 80 mm |
| Housing Material | Reinforced ABS with Anti-Moisture, Anti-Dust & Anti-Static Treatment |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FCC-3000G |
| Pricing | Available Upon Request |
| Sampling Flow Rate | 2 L/min |
| Vacuum Pressure | >5000 Pa |
| Load Capacity | >2000 Pa |
| Dust Fraction Collection | Total Dust & Respirable Dust |
| Continuous Operation Time | >10 h |
| Sound Pressure Level | <60 dB(A) |
| Explosion Protection | Intrinsic Safety, Exib I |
| Operating Temperature | 0–35 °C |
| Relative Humidity | <95% RH |
| Dimensions (L×W×H) | 120 × 80 × 42 mm |
| Weight | 450 g |
| Power Supply | 5× Ni-MH rechargeable cells (1.3 Ah each), series-connected |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FCS-10 |
| Price Range | USD 280 – 700 |
| Power Supply | DC 11.1 V (4.5 Ah Li-ion battery) / AC 220 V ±10%, 50 Hz |
| Flow Range | 1–10 L/min or 1–15 L/min (selectable) |
| Vacuum Pressure | >1500 Pa |
| Flowmeter Accuracy | ±2.5% F.S. |
| Flow Stability | ≤±5% |
| Sampling Flow Error | ≤±5% |
| Noise Level | <75 dB(A) |
| Timer Range | 1 min – 99 h 59 min |
| Timer Accuracy | ≤±0.1% |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | <95% RH |
| Charging Current | 1 A |
| Continuous Operation Time | >5 h |
| Dimensions | 205 × 135 × 115 mm |
| Weight | 2.3 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FD125 |
| Price Range | USD 7,000–14,000 (FOB) |
| Sampling Method | Passive Collection |
| Measurement Range | 0–10 Bq/m³ |
| Minimum Detectable Concentration | 0.01 Bq/m³ |
| Response Time | 300 s |
| Detector Background | ≤100 counts/s |
| Sensitivity Accuracy | ±10% |
| Operating Temperature | 0–45 °C |
| Relative Humidity Limit | ≤95% RH |
| Power Supply | +9–10 V DC for amplifier |
| Weight | 16 kg (excluding scaler unit) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FD216 |
| Price Range | USD 1,400–4,200 |
| Sampling Method | Active Pump-Driven |
| Measurement Range | 3–100,000 Bq/m³ |
| Minimum Detectable Concentration | 3 Bq/m³ |
| Response Time (Air) | 30 min |
| Detector System | ZnS(Ag) Scintillation Screen Coupled with Photomultiplier Tube (PMT) |
| Sensitivity | ≥0.68 cpm/(Bq·m⁻³) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FD218 |
| Price Range | USD 4,200–7,000 |
| Sampling Method | Active Pump-Driven |
| Measurement Range | 2–999,999 Bq/m³ |
| Minimum Detectable Concentration | ≤2 Bq/m³ |
| Response Time | Short |
| Detector | Passivated Implanted Planar Silicon (PIPS) |
| Sensitivity | ≥0.017 cpm/(Bq·m⁻³) [0.63 cpm/(pCi/L)] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | FD218 |
| Price | USD 6,700 (FOB Beijing) |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FT-GD1 |
| Price | USD 10,800 (FOB) |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FT-QC2 |
| Price | USD 570 (FOB) |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Model | TQ-TS200 |
| Soil Moisture Range | 0–100% VWC (±3% accuracy, 0.01% resolution) |
| Soil Temperature Range | −30 to +70°C (±0.3°C, 0.01°C resolution) |
| Soil EC Range | 0–20,000 µS/cm (±3% up to 10,000 |
| Brand | FENK |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Model | CL-101 |
| Measurement Principle | Spectrophotometry (Absorption-based) |
| Wavelengths | 420 nm, 540 nm, 620 nm, 700 nm |
| Accuracy | ≤ ±5% (COD: ≤ ±8%) |
| Repeatability | ≤ 3% |
| Optical Stability | < ±0.001 ABS |
| Data Storage | 1,000 records |
| Display | 4.3-inch capacitive touchscreen LCD |
| Dimensions | 210 × 150 × 110 mm |
| Weight | 1.35 kg |
| Power Supply | DC 5 V / 2 A |
| Battery Capacity | 4800 mAh |
| Operating Environment | −10 to 40 °C, <80% RH (non-condensing) |
| Calibration Modes | Real-time calibration & formula-based calibration |
| Photometric Modes | Absorbance, Concentration, Transmittance |
| Cuvette Format | 16 mm round glass tubes |
| Compliance | Designed for ASTM D1252 (COD), ISO 7150-1 (NH₃-N), and EPA Method 350.1 (Ammonia) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | FGA-4100A |
| Pricing | Upon Request |
| Gas Measurement | HC (0–9999 ppm), CO (0–9.99%), CO₂ (0–20%), O₂ (0–25%), NO (0–5000 ppm), λ (0.5–3.0), Oil Temperature (0–150 °C), RPM (250–10000 rpm) |
| Opacity Measurement | N (0–99.9%), k (0–16 m⁻¹) |
| Resolution | HC (1 ppm), CO (0.01% / 0.001%), CO₂ (0.1% / 0.01%), O₂ (0.1% / 0.01%), NO (1 ppm), λ (0.001), Oil Temp (0.1 °C), RPM (1 rpm), N (0.1%), k (0.001 m⁻¹) |
| Accuracy | HC (±12 ppm or ±5%), CO (±0.06% or ±5%), CO₂ (±0.5% or ±5%), O₂ (±0.1% or ±5%), NO (±25 ppm or ±4%), N (±2%) |
| Response Time | HC/CO/CO₂ ≤10 s |
| Warm-up Time | 15 min |
| Power Supply | AC 220 V ±10%, 50 Hz ±1%, 10 A |
| Power Consumption | ~50 W |
| Weight | Main Unit 9 kg (Control Unit 3 kg + Measurement Unit 4.5 kg) |
| Operating Environment | 5–40 °C, RH 0–95% non-condensing |
| Interfaces | RS-232C, RS-485 |
| Data Storage | 300 test records with timestamp, real-time clock, curve logging, optional EOB-D diagnostics, programmable firmware update via serial port |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | FH463B |
| Price | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | FHT 762 |
| Price Range | USD 13,500–27,000 (FOB) |
| Instrument Class | Dose Rate Meter |
| Form Factor | Portable |
| Measured Radiation | Neutrons |
| Detector Type | Wide-Energy Neutron Detector |
| Dose Equivalent Range | 1 mSv/h – 10 Sv/h |
| Sensitivity | 0.84 cps per µSv/h (calibrated to ²⁵²Cf) |
| Gamma Rejection Ratio | < 5 µSv/h equivalent dose error at 100 mSv/h ¹³⁷Cs |
| Angular Dependence | ±20% over 4π geometry |
| Energy Response Range | 0.025 eV – 5 GeV (ICRP Publication 74, 1996) |
| Brand | EXPEC (Hangzhou Puyu Technology Co., Ltd.) |
|---|---|
| Model | FIA-3000 |
| Measurement Principle | DPD Colorimetric Method (ASTM D1253, ISO 7393-2, EPA 330.5) |
| Wavelength | 510 nm |
| Detection Range | Free Chlorine: 0.01–5.00 mg/L Cl₂ |
| Total Chlorine | 0.02–5.00 mg/L Cl₂ |
| Detection Limit | ≤0.01 mg/L (Free Cl₂), ≤0.02 mg/L (Total Cl₂) |
| Sample pH Adjustment | Automatic buffering to pH 6.2–6.5 |
| Catalyst | Iodide-mediated oxidation for total chlorine conversion |
| Optical System | LED-based photometer with dual-beam compensation |
| Enclosure Rating | IP65 |
| Installation Options | Wall-mounted or benchtop configuration |
| Reagent Consumption | <1.2 mL per analysis cycle |
| Waste Separation | Integrated reagent/waste fluid segregation |
| Compliance | Designed for GLP/GMP-aligned operation |
| Brand | Fitlylab |
|---|---|
| Origin | Shenzhen, China |
| Model | QTOX-60 |
| Instrument Type | Portable |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Repeatability | ≤5% CV |
| Assay Duration | 5, 15, or 30 minutes |
| Detection Range | −120% to +100% inhibition |
| Blank Water Inhibition | ≤±5% |
| Data Storage | 2000 test records via USB |
| Display | Color LCD screen |
| Power Supply | Internal rechargeable Li-ion battery (≥10 h standby), AC adapter, and external power bank compatible |
| Weight | <480 g |
| Accessories | 10 disposable assay tubes, 2 calibrated pipettes, tube rack, standard reagent kit (lyophilized *A. fischeri*, reconstitution buffer, control solution), rugged carrying case |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-Water |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Targets | Total Viable Count (TVC), Total Coliforms, Escherichia coli, Thermotolerant Coliforms (Fecal Coliforms), Pseudomonas aeruginosa, Salmonella spp., Staphylococcus aureus, Enterococcus spp. |
| Certification | ISO/TR 13843:2000, ISO 16140:2003 (as an alternative method), ISO/IEC 17025:2005 compliant internal validation |
| Detection Principle | Integrated enzymatic–immunological–genomic signal amplification in sealed VL detection vials |
| Sample Throughput | 8 independent parallel channels |
| Sensitivity | ≥1 CFU per assay |
| Reporting | Automated PDF report generation with audit-ready metadata |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FJ2000 |
| Price Range | USD 1–299 |
| Instrument Class | Dose/Dose Rate Meter |
| Form Factor | Portable |
| Measured Medium | Air (Ambient Radiation Field) |
| Detector Type | Compensated GM Tube |
| Radiation Types | X-ray and Gamma (γ) |
| Dose Range | 0.0 µSv – 99.99 mSv (Hp(10)) |
| Dose Rate Range | 0.1 µSv/h – 99.99 mSv/h (Hp(10)) |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FL24 |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurable Parameters | Fluorescent Tracers (e.g., Sodium Fluorescein), Turbidity, Temperature |
| Optical Channels | 4 Excitation–Detection Pairs |
| Turbidity Range | 0.2–1000 NTU |
| Fluorescence Detection Limit | 2 × 10⁻¹¹ g/mL (Sodium Fluorescein) |
| Measurement Interval | Configurable from 2 s to 20 min (9 presets) |
| Data Storage Capacity | Up to 240,000 records (4 × 60,000) on removable SD card |
| Temperature Accuracy | ±0.01 °C |
| A/D Resolution | 24-bit |
| Power Supply | 6–12 V DC (Lead-Acid Battery, 12–24 Ah total capacity) |
| Standby Current Draw | 1.5 mA |
| Cable Length | ≥30 m (1 kg per 10 m) |
| Probe Dimensions | Ø48 mm × 270 mm |
| Probe Weight | 3.0 kg |
| Probe Housing | Stainless Steel (EN 1.4404 / AISI 316L) |
| Data Logger | IP68-rated, weight 7.9 kg (incl. two 6 V / 12 Ah batteries) |
| Communication Interface | RS232 or USB (via logger) |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FL30 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurable Parameters | Fluorescent Tracers (e.g., Sodium Fluorescein), Turbidity, Temperature |
| Optional Modules | Conductivity, Pressure |
| Operating Depth | 0–20 m |
| Excitation-Detection Channels | 4 independent optical channels |
| Light Sources | 4 LED-based sources covering UV–visible spectrum |
| Detection Limit | 2 × 10⁻¹¹ g/mL (Sodium Fluorescein), 2 × 10⁻¹⁰ g/mL (Other Tracers) |
| Turbidity Range | 0.2–1000 NTU |
| Temperature Accuracy | ±0.01 °C |
| Data Logging Capacity | Up to 240,000 records (4 parameters × 60,000 entries) on removable 2 GB SD card |
| Sampling Interval | Configurable from 2 s to 20 min (9 preset options) |
| Power Supply | 6–12 V DC (lead-acid battery, 12–24 Ah total capacity) |
| Standby Current Draw | 1.5 mA |
| A/D Resolution | 24-bit |
| Cable Length | ≥15 m (weight: 1 kg per 10 m) |
| Sensor Housing | Stainless steel, Ø160 mm × H170 mm, 7.3 kg |
| Data Logger | Waterproof IP68-rated unit, 7.9 kg (including two 6 V / 12 Ah batteries) |
| Communication Interface | RS232 or USB |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FCC-1500D |
| Pricing | Available Upon Request |
| Flow Range Options | 0.1–1.5 L/min or 0.1–3 L/min |
| Flow Accuracy | ≤ ±5% |
| Timing Accuracy | ≤ ±0.1% |
| Maximum Vacuum | ≥35 kPa |
| Charging Current | 300 mA (standard) |
| Power Supply | 10 V DC / 220 V AC, 50 Hz |
| Operating Temperature | –25°C to +45°C |
| Noise Level | ≤55 dB(A) |
| Relative Humidity | ≤85% RH |
| Dimensions | 100 × 50 × 110 mm |
| Battery Type | Rechargeable Ni-Cd |
| Continuous Operation Time | Up to 24 h per charge |
| Timer Range | 1 min to 99 h 59 min (programmable countdown) |
| Housing Material | AS/ABS engineering plastics with moisture-, dust-, and ESD-resistant coating |
| Origin | France |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FGD-MgO/Lime |
| Pricing | Available Upon Request |