| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MARS |
| Pricing | Upon Request |
| Brand | Metrohm |
|---|---|
| Model | PILS |
| Origin | Imported (Switzerland/USA) |
| Manufacturer | Metrohm AG (via Applikon BV) |
| Power Supply | 110–240 V, 50/60 Hz |
| Sampling Time | 15 min – 1 h |
| Aerosol Size Range | 0.01–10 µm |
| Liquid Collection Medium | Deionized Water |
| Compatibility | Ion Chromatography (IC), including Metrohm and third-party systems |
| Internal Standard Integration | Yes |
| Self-Cleaning Function | Yes |
| Flow Rate Limiting | 1 m³/h |
| Compliance | Designed for GLP/GMP-aligned environmental monitoring workflows |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Models | TitrIC System 1, TitrIC System 2, TitrIC System 3 |
| Pricing | Available upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 6000TOCi |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis |
| Measurement Range | 0–2000 ppb C |
| Accuracy | ±3% |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.025 ppb C |
| Repeatability | ≤3% |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Online DO Analyzer |
| Measurement Principle | Optical Luminescence Quenching (ISO 5814:2012 compliant) |
| Range | 0.00–80.00 mg/L (0– saturation, 0–50 ppm, 0–50,000 ppb) |
| Accuracy | ±0.2 mg/L at 25°C |
| Repeatability | ≤0.05% of reading |
| Detection Limit | <2 ppb (in high-purity water mode) |
| Sensor Technology | ISM® (Intelligent Sensor Management) enabled |
| Compliance | FDA 21 CFR Part 11 ready, USP <1231>, ASTM D888, ISO 5814, EN 25814 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S4, S9 |
| Portability | Portable |
| Measurement Principle | Polarographic (Clark-type) or Optical (Luminescence-based) — configurable per probe |
| Measurement Range | 0.00–50.0 mg/L (ppm) |
| Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% (20–50 mg/L) |
| Repeatability | ±0.05% of reading |
| Detection Limit | ±2 ppb (O₂ in water) |
| Ingress Protection | IP67 |
| Electrode Compatibility | ISM® (Intelligent Sensor Management) enabled |
| Data Interface | Waterproof USB (IP67-rated) |
| Display | High-contrast, sunlight-readable LCD with StatusLight™ indicator |
| Language Support | 12 languages including English, German, French, Spanish, Chinese, Japanese, Korean, etc. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | SG9 |
| Instrument Type | Laboratory-Portable |
| IP Rating | IP67 |
| Measurement Principle | Optical Luminescence (RDO® Technology) |
| DO Range | 0.00–80.00 mg/L (ppm) |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% (20–80 mg/L) |
| Saturation Range | 0.0–50.0% |
| Saturation Resolution | 0.1% |
| Barometric Pressure Range | 500–1100 mbar |
| Pressure Resolution | 0.1 mbar |
| Data Storage | 500 GLP-compliant records |
| Calibration Management | ISM® Intelligent Sensor Management |
| Sensor Interface | Digital ISM-enabled OptiOx probe |
| Communication | Infrared (IR) interface |
| Operating Modes | Standard / Expert |
| Endpoint Options | Auto, Manual, Timed |
| Compliance | GLP, ISO/IEC 17025-supporting workflows, FDA 21 CFR Part 11-ready (with optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Line | SevenGo Series |
| Portability | Handheld / Field-Deployable |
| IP Rating | IP67 |
| Display | Backlit LCD (Professional Models) |
| Connectivity | Infrared (IR) Interface (Professional Models) |
| Data Management | Onboard Storage + PC Export via ErGo Assistant Software |
| Form Factor | Modular Electrochemical Meter Platform |
| Compliance | Designed for ASTM D1293, ISO 7888, ISO 5814, USP <645>, and EPA Method 120.1 / 120.2 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 2300Na |
| Measurement Range | 0.001–100,000 ppb Na⁺ |
| Calibration | Unattended 3-point incremental or manual 1-/2-point |
| Dimensions | 900 × 450 × 190 mm |
| Analog Outputs | (4) 0/4–20 mA |
| Electrode Activation | Automatic during calibration |
| Enclosure Options | Fully enclosed locked cabinet or semi-enclosed with service door |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 2800Si |
| Detection Limit | 0.8 ppb |
| Measurement Range | 0–5000 ppb |
| Accuracy | ±5% of reading or ±1 ppb (whichever is greater) |
| Cycle Time | Adjustable, typically 20 minutes |
| Maximum Sample Pressure | <7 bar (100 psig) |
| Compliance | Designed for ASTM D4582, ASTM D5116, ISO 14687-2, and power plant water chemistry guidelines per EPRI TR-102328 & IAPWS RP-7 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 4000TOCe |
| Instrument Type | Online TOC Analyzer |
| Measurement Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.05–1000 ppb C |
| Accuracy | ±0.1 ppb (TOC < 2 ppb) |
| Resolution | 0.001 ppb |
| Detection Limit | 0.025 ppb |
| Repeatability | ±0.05 ppb (<5 ppb) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 450TOC |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.05 – 1000 ppb C (μg C/L) |
| Accuracy | ±0.1 ppb C for TOC < 2.0 ppb |
| Resolution | 0.001 ppb C (μg C/L) |
| Detection Limit | 0.025 ppb C |
| Repeatability | ±0.05 ppb C (< 5 ppb), ±1.0% (> 5 ppb) |
| Sample Temperature | 0–70 °C |
| Particle Size Limit | < 100 µm |
| Conductivity Requirement | ≥0.5 MΩ·cm (≤2 µS/cm) |
| pH Limit | < 7.5 |
| Flow Rate | 20 mL/min |
| Inlet Pressure | 4–85 psig (0.3–5.8 bar) |
| Dimensions | 334 × 185 × 324 mm |
| Weight (with base) | 7.0 kg |
| Enclosure Material | UL 94 V-0 Flame-Retardant Polystyrene |
| Wetted Materials | 316 Stainless Steel, Quartz, PEEK, Titanium, PTFE, Silicone, FFKM, EPDM |
| Environmental Operating Range | 5–50 °C / 5–80% RH (non-condensing) |
| Power | 100–240 VAC, 50/60 Hz, max. 40 W |
| Certifications | CE, cULus |
| Traceability | NIST-traceable conductivity & temperature sensors per ASTM D1125 and D5391 |
| Compliance | ASTM D5173, USP <643>, EP 2.2.44, JP 2.59, ChP 0912 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | 770MAX |
| Input Channels | 6 (up to 16 measured parameters) |
| Sensor Types Supported | 8 (e.g., conductivity/resistivity, pH/ORP, dissolved oxygen, ozone, TOC, flow, temperature, pressure, level) |
| Output Options | 4 or 8 × 0/4–20 mA analog outputs |
| Communication | RS232 serial interface |
| Relay Outputs | 4 (optional) |
| Display | Multi-line scrolling LCD with customizable parameter naming |
| Power Supply | Universal 100–240 VAC, 50–60 Hz |
| Enclosure | 1/4 DIN, IP65-rated with sealed rear cover |
| Calibration Support | NIST-traceable verification via optional 1875 Smart Calibrator |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MIC-500S-MEK |
| Output Options | 4–20 mA (3-wire or 4-wire), 0–5/0–10 V, RS485 (Modbus RTU), Dual Relay Outputs |
| Communication | Wired, LAN, Internet, Wireless (433 MHz, GPRS, Wi-Fi, Custom RF) |
| Remote Operation | Infrared remote control (15 m range, intrinsically safe operation without opening enclosure) |
| Calibration | Auto-zero tracking, multi-point calibration support |
| Certifications | CPA Type Approval (China), Ex d IIC T6 Gb explosion-proof certification, EMC/EMI compliant (GB/T 18268, GB/T 17626 series), Anti-static & reverse-polarity protected |
| Sensor Options | Electrochemical, Catalytic Bead, NDIR, PID, Thermal Conductivity (selectable from Honeywell, Figaro, City Technology, Alphasense, Dynament, Membrapor) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ALTUM |
| Pricing | Upon Request |
| Brand | Micro-Hybrid |
|---|---|
| Origin | Germany |
| Model | INC5701D-360-SA-U/I |
| Measuring Range | 1°–360° |
| Supply Voltage | 5–32 V DC |
| Angular Accuracy (Digital Interface) | < 0.04° |
| Angular Accuracy (Analog Interface) | < 0.12° |
| Digital Interfaces | RS485, Ethernet, PROFINET, EtherNet/IP |
| Analog Outputs | 4–20 mA (max. 390 Ω), 0.5–4.5 V (min. 1 kΩ, configurable) |
| Operating Temperature | −40 °C to +85 °C |
| Housing Material | Die-cast Aluminum |
| Weight | ~250 g |
| Embedded Signal Processing | SensorFUSION Algorithm |
| Brand | Micro-Hybrid |
|---|---|
| Origin | Germany |
| Model | ACC5703 |
| Axes | 3 |
| Measuring Range | ±0.1 g to ±8 g (configurable) |
| Resolution (Digital) | ≤0.016 mg |
| Resolution (Analog Current) | ≤0.24 mg |
| Resolution (Analog Voltage) | ≤0.31 mg |
| Noise Density | 30 µg/√Hz (typ.) |
| Sensitivity (Current Output) | ≤80 mA/g |
| Sensitivity (Voltage Output) | ≤20 V/g |
| Zero Output | 12 mA or 2.5 V |
| Linearity | 0.45 % FSO (typ.) |
| Frequency Range | 0–1000 Hz (configurable) |
| Sampling Rate | Up to 4 kHz |
| Cross-Axis Sensitivity | 1 % FSO |
| Temperature Stability | ±0.2 mg/K (typ.) |
| Supply Voltage | 5–32 VDC |
| Power Consumption | <3 W |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +85 °C |
| Digital Interface | RS485 |
| Analog Outputs | 4–20 mA (max. 390 Ω) and 0.5–4.5 V (min. 1 kΩ), configurable |
| Switching Output | 0/5 V (min. 1 kΩ) |
| Protection Rating | IP67 (when connected) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TOXmini |
| Instrument Type | Portable |
| Biological Indicator | Aliivibrio fischeri (formerly Vibrio fischeri) |
| Operating Temperature Range | +15 °C to +30 °C |
| Reagent Storage & Handling Temperature | +2 °C to +8 °C |
| Repeatability | ≤15% RSD (Relative Standard Deviation) at 50% inhibition level |
| Batch Capacity | 1–12 samples per run |
| Typical Measurement Time | 15–30 min per sample (ISO 11348-3 compliant) |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYSTEA Micromac C |
| Pricing | Upon Request |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China (Distributed) |
| Model | SYSTEA Micromac C |
| Measurement Principles | Colorimetric Spectrophotometry (UV-Vis) |
| Analytes | Nitrate-N, Nitrite-N, Ammonia-N, Orthophosphate, Silicate, Sulfate, Total Phosphorus, Total Nitrogen |
| Detection Method | Batch-type Flow-Through Cell with LED-based Photometric Detection |
| Operating Modes | Manual, Cyclic, Triggered, Continuous |
| Communication Interfaces | RS232, RS485, 4–20 mA analog output |
| Optional | Ethernet interface, Pre-treatment module, Dual-waste separation (toxic/non-toxic), Leak detection sensor, Reagent level monitoring |
| Compliance Support | Designed for continuous unattended operation in GLP-aligned environmental monitoring labs |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Micromac C |
| Pricing | Available Upon Request |
| Brand | Micrometrix |
|---|---|
| Origin | USA |
| Model | SCM-1 |
| Measurement Range | −1000 to +1000 mV |
| Output | 4–20 mA, ±10 V, 0–10 V |
| Display | LED, millivolt resolution |
| Flow Rate | 1 L/min (standard), 5 GPM (optional) |
| Inlet/Outlet | 1/2″ barb inlet, 3/4″ barb outlet |
| Response Time | 1 second |
| Accuracy | ±0.1% of full scale |
| Enclosure | NEMA 4X, IP65 |
| Power | 230 VAC |
| Probe Materials | Delrin®, 316 stainless steel, PTFE |
| Sensor Serviceability | Replaceable piston, disposable PTFE sleeve, field-swappable electrodes |
| Communication | Modbus RTU (optional) |
| Alarm Outputs | Dual SPDT relays with adjustable setpoints |
| Zero & Sensitivity Adjustment | Front-panel accessible, continuous analog tuning |
| Diagnostic Indication | Flashing LED status indicator |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ML-91 |
| Price | USD 950 (FOB Jiangsu) |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | 66 % ±15 % RH |
| Atmospheric Pressure | 750 mmHg ±30 mmHg |
| Frequency Band | 3–33 cm (i.e., 0.9–10 GHz) |
| Power Density Range | 0.2 µW/cm² to 20 mW/cm² |
| Display | 3-digit LED, auto-ranging across 200 µW/cm² / 2 mW/cm² / 20 mW/cm² scales with LED range indicators |
| Alarm Threshold | Adjustable, default ≥5 mW/cm² |
| Calibration Field Accuracy | ±0.75 dB |
| Full-Scale Indication Error (at rated voltage) | ≤±1.5 % |
| Indicator Dimensions | 82 mm × 40 mm × 172 mm |
| Net Weight | 0.8 kg |
| Brand | Starwood |
|---|---|
| Model | ZLFI00001 |
| Membrane Diameter | 47 mm |
| Membrane Pore Size | 0.45 µm |
| Test Pressure | 2.0–2.2 bar (29–32 psi) |
| SDI Calculation Interval | 0–5–15 min |
| Compliance | ASTM D4189-95 |
| Includes | Pressure Regulator, 47 mm Filter Holder, ASTM-Compliant Mixed Cellulose Ester (MCE) Membranes |
| Accessories Required | 500 mL Graduated Cylinder (±5 mL graduation), Stopwatch (±0.2 s resolution) |
| Brand | Minhope |
|---|---|
| Model | MH1200-G |
| Origin | Shandong, China |
| Instrument Type | Integrated Ambient Air Sampler for TSP, PM₁₀, PM₂.₅, Heavy Metals, Fluorides, and Semi-Volatile Organic Compounds (SVOCs) |
| Compliance | JJG 943–2011, HJ 618–2011, HJ 93–2013, HJ 691–2014 |
| Operating Modes | Instant, Timed, and Volume-Based Sampling |
| Environmental Parameter Compensation | Real-time Temperature & Barometric Pressure Measurement with Flow Correction |
| Enclosure | Weather-Resistant, Compact, Low-Noise Design |
| Power Consumption | Low |
| Weight | Lightweight for Field Deployment |
| Brand | Minhope |
|---|---|
| Model | MH3010-E |
| Construction Material | Titanium Alloy Probe Body |
| Heating Zones | Dual-Zone (Probe Tip & Filter Holder) |
| Compliance | HJ 77.2–2008, HJ/T 365–2007, GB/T 16157–1996, JJG 680–2007, JJG 968–2002 |
| Application | Isokinetic Sampling of Gas-Phase and Particulate-Bound Dioxins/Furans from Municipal Solid Waste Incinerators and Hazardous Waste Combustors |
| Operating Temperature Range | Ambient to 250 °C (adjustable, ±1 °C stability) |
| Probe Length | Standard 1.2 m (custom lengths available) |
| Filter Holder | Quartz Fiber Filter + Polyurethane Foam (PUF) Sorbent Trap |
| Pitot Tube | Rotatable, Stainless Steel, Integrated with Differential Pressure Sensor |
| Data Interface | Analog 4–20 mA outputs for temperature, velocity, and static/dynamic pressure |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Model | Aluminum Ion Detector |
| Type | Portable Multi-Ion Analyzer |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed for Field-Deployable Water Quality Monitoring per ISO 10523, ASTM D3590, and EPA Method 200.7 (ICP-OES reference correlation) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Quartz Crystal Microbalance (QCM) with Gold-Plated Fluoride-Specific Sensor Chip |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Regulatory Compliance | Designed for ISO 10523, ASTM D4192, and EPA Method 300.0–compatible workflows |
| Software Interface | USB-C–enabled embedded firmware with real-time data streaming and CSV export |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Endotoxin Detection System |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microfluidic Sensor Chip |
| Sensitivity | 0.00742 EU/mL |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed to support USP <85>, EP 2.6.14, and ISO 11737-1 workflows |
| Sample Format | Aqueous liquid samples only |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Interface | USB-C & Bluetooth 5.0 |
| Software Platform | MIPS EndoTrack™ v3.2 (Windows/macOS compatible) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Pesticide Detection System |
| Instrument Type | Multi-Ion Analyzer |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microsensor Chips |
| Sample Matrix | Aqueous Solutions |
| Configurations | Single-, Dual-, or Multi-Channel Options Available |
| Integrated Components | Micro-peristaltic Pumps, Multi-Functional Microfluidic Analysis Chamber, Embedded Signal Processing Unit |