Environmental Test Chamber
Filter
Showing 871–900 of 3663 results
| Brand | inTEST Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-730 |
| Temperature Range | -85°C to +225°C |
| Transition Rate | <10 s from -55°C to +125°C and vice versa |
| Airflow Capacity | 4–18 scfm (1.8–8.5 L/s) |
| Temperature Resolution | ±1°C |
| Temperature Accuracy | ±1°C (NIST-traceable calibration) |
| Control Interface | Touchscreen HMI |
| Remote Interfaces | IEEE-488 (GPIB), RS-232 |
| Sensor Compatibility | Type T or K thermocouples (DUT mode) |
| Compliance | CE-marked, CFC-free |
| Optional Configurations | ATS-730-M robotic arm, ATS-730-H extended-height arm, ATS-730-T test chamber variant |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS710E |
| Temperature Range | −75 °C to +225 °C |
| Temperature Stability | ±0.1 °C |
| Transition Time (−55 °C ↔ +125 °C) | ~10 s |
| Compliance | NIST-traceable calibration, CE-marked, UL-listed enclosure |
| Control Interface | RS-232 / IEEE-488 (GPIB), touchscreen HMI |
| Integrated Air Compressor | No |
| Gas Flow Rate | 4–18 SCFM |
| Temperature Resolution | 0.01 °C |
| Over-Temperature Protection | Dual-stage hardware + user-configurable limits |
| Brand | inTEST Temptronic |
|---|---|
| Origin | USA |
| Model | ECO-710-M |
| Temperature Range | -80°C to +225°C |
| Cooling/Heating Method | Compressed Dry Air with Integrated Refrigeration & Resistive Heating |
| Thermal Ramp Rate | Up to 150°C/min (typical, dependent on DUT mass and fixture) |
| Control Mode | Air Mode (directed convective thermal stream) |
| Compliance | Designed for ASTM F1634, Telcordia GR-468-CORE, IEC 61300-2-22, and JEDEC JESD22-A104 environmental stress screening protocols |
| Software Interface | Windows-based Temptronic TControl™ v5.x with 21 CFR Part 11-compliant audit trail and user role management |
| Footprint | Benchtop, modular integration capable |
| Brand | inTEST Temptronic |
|---|---|
| Origin | USA |
| Model | ECO-710E |
| Temperature Range | −80 °C to +225 °C |
| Thermal Shock Range | −80 °C to +225 °C |
| Temperature Stability | ±1.0 °C |
| Ramp Rate (Heating) | −55 °C to +125 °C in ≤10 s |
| Ramp Rate (Cooling) | +125 °C to −55 °C in ≤10 s |
| Airflow Output | 4–18 SCFM |
| Temperature Accuracy | ±1.0 °C (NIST-traceable calibration) |
| Power Supply | 200–250 VAC, 50/60 Hz, 20 A, single-phase |
| Brand | inTEST-Temptronic |
|---|---|
| Origin | USA |
| Model | DCP-102 |
| Temperature Shock Range | -65 to 175°C |
| Temperature Stability | ±0.3°C |
| Heating Rate | 25°C to +125°C in <1.5 min |
| Cooling Rate | 25°C to -40°C in <35 sec |
| Cooling Power | 55W @ -55°C, 125W @ -40°C, 250W @ 0°C |
| DUT Force Range | 2–100 kgf |
| DUT Size Compatibility | 2×2 mm to 100×100 mm |
| Heat Sink Diameter | 89 mm |
| Required Gas Supply | Dry, clean air or nitrogen at -70°C, 0.1 cfm @ 0.2 bar |
| Weight | 66 kg |
| Sensor Options | RTD, K-type thermocouple, diode, 100 Ω RTD, analog input |
| Calibration | Software-based |
| Communication Interfaces | Ethernet (TCP/IP), optional USB, IEEE-488 (GPIB), RS-232 |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS Series |
| Temperature Range | –100 °C to +300 °C |
| Temperature Stability | ±1 °C |
| Ramp Rate | Up to 18 °C/s (heating/cooling) |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-505E |
| Temperature Range | −20°C to +225°C |
| Airflow Output | 4–10 SCFM (1.9–4.7 L/s) |
| Ramp Rate | 0°C → +125°C <3 min |
| Temperature Accuracy | ±1°C |
| Temperature Resolution | 0.1°C |
| Sensor Type | T-type or K-type thermocouple |
| Remote Interface | IEEE-488 (GPIB), RS-232 |
| Brand | inTEST Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-515 |
| Temperature Range | -45°C to +225°C |
| Ramp Rate | -40°C to +125°C <12 s |
| Temperature Accuracy | ±1.0°C (NIST-traceable calibration) |
| Temperature Resolution | 0.1°C |
| DUT Sensor Interface | T-type and K-type thermocouple inputs |
| Airflow Control | Dry air purge (0.25–1.5 L/s) |
| Power Supply | 200±10% VAC, 50 Hz, 16 A |
| Operating Ambient | 20–28°C, 0–60% RH (45% nominal) |
| Controller Dimensions (W×H×D) | 26.7 × 20.7 × 9.8 cm |
| Chiller Dimensions (W×H×D) | 51.3 × 41.4 × 74.9 cm |
| Hot Air Nozzle Diameter | 13.97 cm |
| System Weight | 112 kg (chiller: 74.5 kg |
| chiller + mobile cart | 100.8 kg) |
| Compliance | CE-marked, CFC-free refrigerant, RoHS-compliant |
| Brand | inTEST Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-525 |
| Temperature Range | -60°C to +225°C |
| Temperature Stability | ±0.01°C |
| Ramp Rate (Cold to Hot) | -40°C to +125°C in <12 sec |
| Ramp Rate (Hot to Cold) | +125°C to -40°C in <40 sec |
| Airflow | 5 scfm (2.4 L/s) |
| Temperature Display Resolution | ±1°C |
| Temperature Accuracy | ±1°C (NIST-traceable calibration) |
| Overtemperature Protection | Factory-set at +230°C, user-configurable |
| Refrigerant | CFC-free, non-toxic, non-flammable |
| Compliance | CE-marked |
| Interface | IEEE-488 (GPIB), RS-232, LabVIEW™ drivers |
| Control | Rotary knob panel with onboard data logging |
| Operating Modes | Air Mode, DUT Mode (T-type or K-type thermocouple input) |
| Thermal Shroud Diameter | 13.97 cm |
| Dimensions (Controller) | 26.7 × 20.7 × 9.8 cm |
| Dimensions (Chiller Unit) | 51.3 × 41.4 × 74.9 cm |
| Weight (Total) | 112 kg |
| Noise Level | <60 dB(A) |
| Brand | inTEST-Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-535 |
| Temperature Range | -60°C to +225°C |
| Temperature Stability | ±0.1°C |
| Temperature Uniformity | ±0.1°C |
| Temperature Accuracy | ±1.0°C (NIST-traceable calibration) |
| Ramp Rate | -40°C to +125°C in <12 s |
| Ramp Rate | +125°C to -40°C in <40 s |
| Airflow Output | 5 SCFM (2.4 L/s), constant flow |
| Control Interface | IEEE-488, RS-232, LabVIEW™ drivers |
| DUT Sensor Support | Type T & K thermocouples |
| Power Requirements | Refrigeration Unit: 220 VAC ±10%, 50/60 Hz, 16 A |
| Compressor Unit | 220 VAC ±10%, 50/60 Hz, 30 A |
| Dimensions | 194.7 cm × 61.7 cm × 108.6 cm |
| Weight | 249.5 kg |
| Noise Level | <70 dBA |
| Refrigerant | CFC-free, non-toxic, non-flammable |
| Brand | inTEST-Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-535 |
| High Temperature Range | +225°C |
| Low Temperature Range | −60°C |
| Thermal Shock Range | −60°C to +225°C |
| Temperature Stability | ±0.01°C |
| Heating Rate | −40°C to +125°C in <12 s |
| Cooling Rate | +125°C to −40°C in <40 s |
| Airflow Output | 5 SCFM (2.4 L/s) |
| Temperature Resolution | ±0.1°C |
| Temperature Accuracy | ±1.0°C (NIST-traceable calibration) |
| DUT Temperature Control | Closed-loop algorithm with T- or K-type thermocouple input |
| Power Supply | Refrigeration unit: 220 VAC ±10%, 50/60 Hz, 16 A |
| Compressor | 220 VAC ±10%, 50/60 Hz, 30 A |
| Dimensions | 194.7 × 61.7 × 108.6 cm |
| Weight | 249.5 kg |
| Noise Level | <70 dBA |
| Compliance | CE, CFC-free refrigerant (non-toxic, non-flammable), RoHS |
| Brand | inTEST Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-545-M |
| Temperature Range | -80°C to +225°C |
| Ramp Rate | Up to 18°C/s |
| Temperature Accuracy | ±1°C |
| Application | IC-level and board-level thermal shock, temperature cycling, burn-in, and reliability testing |
| Compliance | Designed for ASTM E1543, JEDEC JESD22-A104, MIL-STD-883 Method 1010, and IEC 60068-2-14 |
| Brand | LabCompanion |
|---|---|
| Origin | USA |
| Manufacturer | inTEST Corporation |
| Model | ThermoStream TS-3000 Series (representative high-performance variant) |
| Temperature Range | −100 °C to +300 °C |
| Temperature Stability | ±2 °C |
| Ramp Rate (Heating) | −55 °C to +125 °C in <10 s |
| Ramp Rate (Cooling) | +125 °C to −55 °C in <10 s |
| Temperature Display Accuracy | ±1 °C |
| Calibration | NIST-traceable |
| Compliance | ISO 9001, CE, RoHS |
| Brand | inTEST (formerly Temptronic & Thermonics) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ATS-500 / ATS-700 Series |
| Price Range | USD 28,000 – 70,000 |
| Brand | inTEST-ThermoStream |
|---|---|
| Model | ATS-505 / ATS-535 |
| Temperature Range | -60°C to +225°C |
| Ramp Rate | Up to 18°C/s |
| Temperature Accuracy | ±1°C |
| Control Mode | Air Mode (ATS-505), DUT Mode (ATS-535) |
| Integrated Compressor | ATS-535 only |
| Safety Protection | Adjustable Over-Temperature Cut-off (Factory Default: +230°C) |
| Compliance | Designed for Semiconductor Process Validation, GLP/GMP-Aligned Operation |
| Brand | inTEST- Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-505 |
| Temperature Shock Range | −20°C to +225°C |
| Temperature Stability | ±1.0°C |
| Heating Rate | 0°C to +125°C in <3 min |
| Cooling Rate | +125°C to 0°C in <4 min |
| Humidity Range | 0–60% RH (45% RH nominal) |
| Temperature Resolution | ±0.1°C |
| Temperature Accuracy | ±1.0°C (NIST-traceable calibration) |
| Supply Air Temperature | +20°C to +28°C (nominal +23°C) |
| Supply Pressure | 5.6–7.0 kg/cm² (80–90 PSIG) |
| Power | 200–250 VAC, 50/60 Hz, 10 A, Single-phase |
| Interface | IEEE-488 & RS-232 |
| Software Support | LabVIEW™ Driver |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-545 |
| High-Temperature Range (°C) | 0 to +225 (50 Hz) |
| Low-Temperature Range (°C) | −75 to 0 (50 Hz) |
| Thermal Shock Range (°C) | −75 to +225 (50 Hz) |
| Temperature Stability | Excellent |
| Ramp Rate (°C/min) | ~10 s for −55 °C to +125 °C |
| Ramp Rate (°C/min) | ~10 s for +125 °C to −55 °C |
| Airflow Output | 4–18 scfm (1.9–8.5 L/s) |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Resolution | ±0.1 °C |
| Sensor Type | T- or K-type thermocouple |
| Refrigeration | Auto-cascade, non-ozone-depleting refrigerant, LN₂-free |
| ESD Protection | Integrated patented design |
| Operating Noise | <65 dBA |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ThermoStream ATS-545-M |
| Temperature Range | –80 °C to +225 °C |
| Cooling/Heating Medium | Dry, Filtered Compressed Air |
| Control Interface | Rotary Knob Panel with Real-Time Sensor Feedback |
| Safety Protection | Dual-Stage Over-Temperature Cut-Off (Factory-Set at +230 °C, User-Configurable Limits) |
| Form Factor | Mobile Benchtop Unit Compatible with Robotic Handler Integration |
| Compliance | Designed for ASTM F1876, Telcordia GR-468-CORE, IEC 61300-2-22, and JEDEC JESD22-A104 thermal cycling protocols |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-710-M |
| High Temp Range | +225 °C |
| Low Temp Range | −80 °C |
| Thermal Shock Range | −80 °C to +225 °C |
| Temperature Stability | ±1 °C |
| Ramp Rate | ~10 s from −55 °C to +125 °C (or reverse) |
| Airflow Output | 4–18 SCFM (1.8–8.5 L/s) |
| Temp Display Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Remote Interfaces | IEEE-488, RS232, Ethernet |
| Compliance | NIST-traceable calibration, fluorocarbon-free refrigerant, GLP/GMP-ready data logging |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | inTEST ATS-730E |
| Temperature Range | −85 °C to +225 °C (50 Hz) / −90 °C to +225 °C (60 Hz) |
| Airflow Output | 4–18 scfm (1.8–8.5 L/s) |
| Transition Rate | −55 °C to +125 °C in ≈10 s |
| Temperature Accuracy | ±1 °C (NIST-traceable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Control Interfaces | IEEE-488, RS232, Ethernet |
| Compliance | CE, RoHS, CFC-free |
| Dimensions (W×D×H) | 61.0 × 72.4 × 108.0 cm |
| Net Weight | 236 kg |
| Optional Configurations | Robotic arm, turntable, height-adjustable stand, heated lid, handheld thermal probe |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor (Imported) |
| Model | ATS-750 |
| Price Range | USD 28,000 – 70,000 (FOB) |
| Temperature Range | −85 °C to +300 °C (50 Hz) / −90 °C to +300 °C (60 Hz) |
| Airflow Output | 4–18 SCFM (1.8–8.5 L/s) |
| Transition Rate | −55 °C → +125 °C in ~10 s |
| Temperature Stability | ±0.01 °C |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Control Interfaces | IEEE-488 (GPIB), RS-232, Ethernet |
| Operating Modes | Air Mode & DUT Mode |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (via optional audit trail software), GLP/GMP-ready |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ECO-560 |
| High Temperature Range | +200 °C |
| Low Temperature Range | −60 °C |
| Thermal Shock Range | −60 °C to +200 °C |
| Frequency | 50/60 Hz |
| Temperature Stability | ±0.01 °C |
| Ramp Rate (Heating) | −40 °C to +150 °C in <15 s |
| Ramp Rate (Cooling) | +125 °C to −40 °C in <35 s |
| Airflow Output | 4–18 SCFM (1.9–8.5 L/s) |
| Temperature Display Resolution | ±0.1 °C |
| Temperature Accuracy | ±1.0 °C (NIST-traceable calibration) |
| DUT Temperature Control | Proprietary closed-loop algorithm with direct DUT sensing |
| Thermocouple Inputs | Type T & K |
| Power Supply | 200–250 VAC, 50/60 Hz, 30 A (1-phase, 230 V nominal) |
| Operating Ambient | 20–28 °C (23 °C nominal), 0–60% RH (45% rated) |
| Dimensions (W×D×H) | 46.4 × 66.7 × 142.2 cm |
| Weight (Unit) | 181 kg |
| Weight (Packed) | 227 kg |
| Acoustic Noise | <57 dBA |
| Brand | inTEST- Temptronic |
|---|---|
| Origin | USA |
| Model | ECO-710 |
| Temperature Range (°C) | -80 to +225 |
| Temperature Stability (°C) | ±0.01 |
| Transition Time (°C) | +125 to −55°C in ~10 s |
| Airflow Output | 4–18 scfm (1.8–8.5 L/s) |
| Temperature Accuracy | ±1°C |
| Temperature Resolution | 0.1°C |
| Noise Level | ≤56 dBA |
| Input Power | 20 A |
| Refrigerant | Non-ozone-depleting, non-flammable HFC blend |
| Compliance | RoHS, CE, UL 61010-1, IEC 61000-6-3 |
| Brand | inTEST-Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-710-M |
| Temperature Range | -80 °C to +225 °C |
| Ramp Rate | Up to 18 °C/s |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Operating Modes | Air Mode & DUT Mode |
| Compliance | NIST-traceable calibration, supports GLP/GMP-relevant audit trails |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Compliance | IEC 60529, ISO 20653, SAE J575, GB/T 4208 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| IP Rating Coverage | IPX5, IPX6, IPX7 |
| Compliance Standards | IEC 60529, ISO 20653, GB/T 4208, MIL-STD-810H Method 506.7, GJB 150.8A, IEC 60068-2-68, GB/T 2423.38, IEC 60034-5, GB/T 4942.1 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Compliance | IPX5, IPX6 per IEC 60529, ISO 20653, GB/T 4208, MIL-STD-810G Method 512.6, ASTM D7706 |