Environmental Test Chamber
Filter
Showing 841–870 of 3663 results
| Key | Temperature Range: RT+10°C to 300°C (customizable up to 500°C) |
|---|---|
| Internal Dimensions (OK-T-72) | 450×400×400 mm (W×H×D) |
| Internal Dimensions (OK-T-150) | 500×600×500 mm (W×H×D) |
| External Dimensions (OK-T-72) | 650×900×600 mm (W×H×D) |
| External Dimensions (OK-T-150) | 700×1200×700 mm (W×H×D) |
| Temperature Uniformity | ±1.5°C |
| Control Accuracy | ±0.5°C |
| Heating System | Dual independent 2 kW far-infrared Ni-Cr alloy heaters |
| Sensor | PT100 platinum resistance thermometer |
| Controller | Microprocessor-based digital touchscreen controller with timer (0–999 min) |
| Power Supply | AC220V±5% / 50 Hz or AC380V±5% / 50 Hz |
| Total Rated Power | 2000 W (OK-T-72), 4500 W (OK-T-150) |
| Construction | Interior – SUS#304 stainless steel |
| Standard Accessories | 2–3 adjustable stainless steel wire shelves |
| Safety Features | Leakage current protection, over-temperature alarm and cutoff, thermal fuse backup |
| Compliance | Designed per GB/T 2423.2 (IEC 60068-2-2) for high-temperature environmental testing |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,700 (Reference Only) |
| Temperature Range | RT+10°C to 200°C / 300°C |
| Uniformity | ±2°C |
| Temperature Stability | ±0.5°C |
| Air Exchange Rate | 2–100 cycles/hour |
| Adjustable Exchange Interval | 1 min – 99 h |
| Control Accuracy | ±0.1°C (setpoint & display) |
| Timer Range | 1–9999 min |
| Insulation | High-Density Glass Fiber |
| Interior Material | SUS304 Stainless Steel |
| Exterior Material | A3 Steel with Powder Coating |
| Viewing Window | Tempered Glass with LED Illumination |
| Test Port | Φ50 mm (left side) |
| Turntable Diameter | Φ250–Φ700 mm (model-dependent) |
| Power | 4.0–9.0 kW |
| Compliance | ASTM D5423-09 (Type II), ASTM D5374-93 (2005), UL 1581, GB/T 2423.2, IEC 60068-2-2, JIS C 0021, VDE 0470 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Temperature Range | RT+10 °C to 70 °C |
| Salt Solution Circulation | Dual-pump alternating system |
| Dwell Time Control | Adjustable up/down immersion intervals (0.01 s–9999 hr) |
| Total Test Duration | Programmable 0.01 s–9999 hr |
| Cycle Counter | 0–99999 cycles (resettable) |
| Compliance | GB/T 2423.17, GB/T 10587, GJB 150.11A, DIN 50021, ISO 9227 (as applicable) |
| Key Features | Temperature Range: +5°C to 55°C |
|---|---|
| Humidity Range | 85–95% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ≤ ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL/80 cm²·h |
| Spray Modes | Continuous or Cyclic |
| Test Timing | 1–999 sec/min/hr (adjustable) |
| Chamber Construction | 6 mm PVC-coated chamber walls (heat-resistant to 80°C), SUS#304 stainless steel saturated air tank, transparent acrylic impact-resistant lid |
| Air Supply System | Two-stage pressure regulation (1 kg/cm²), integrated particulate filtration |
| Sample Rack | Adjustable flat-angle fixture (15°/30°), multi-directional fog exposure |
| Compliance | Designed per CNS, JIS Z 2371, ASTM B117 (NSS), ASTM G85 Annex A2 (CASS) |
| Models | OK-FH-150B / OK-FH-250B / OK-FH-750B |
| Power Consumption | 1.3 kW / 1.5 kW / 1.8 kW |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT+5°C to 55°C |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Spray Mode | Air-Atomized (Continuous or Cyclic) |
| Internal Dimensions | 600 × 450 × 400 mm (L×W×H) |
| External Dimensions | Approx. 1075 × 1185 × 630 mm (L×W×H) |
| Saturated Air Heater Range | RT+47°C to 63°C |
| Power Supply | 220 V, 1.5 kW, 50 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 4,100 (FOB) |
| Internal Dimensions (Φ × D) | 30×45 cm to 60×65 cm |
| Temperature Range | 121°C, 132°C (143°C optional) |
| Humidity | 100% RH saturated steam |
| Operating Pressure | 0.0–2.0 bar(g) (3.0 bar[g] optional) |
| Temp. Uniformity | ≤±2°C |
| RH Uniformity | ≤±3% RH |
| Heating/Circulation | Saturated steam natural convection |
| Safety Systems | Low-water cutoff, overpressure relief valve, overtemperature cutout, auto-locking pressure-interlocked door, real-time pressure/temperature monitoring |
| Power Supply | AC 220 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Hirayama |
|---|---|
| Origin | Japan |
| Model | PC-R9 Series (PC-304R9, PC-422R9, PC-304R9D, PC-422R9D) |
| Control Interface | Color Touch Panel with Remote Application Support |
| Data Storage | External USB Memory |
| Communication | RS-485 / Ethernet (Optional) |
| Cooling System | Integrated Drainable Chilled Water Tank |
| Chamber Configuration | Dual-Chamber Design |
| Optional Features | Air Purge Function, External Pressure Supply, Auto-Cleaning for Electrochemical Migration (ECM) Evaluation |
| Brand | Hirayama |
|---|---|
| Origin | Japan |
| Model | PC-R9 Series (PC-304R9, PC-422R9, PC-304R9D, PC-422R9D) |
| Chamber Capacity | 304 L / 422 L |
| Dual-Chamber Configuration | Standard (Dual-Tank System) |
| Pressure Range | Up to 300 kPa (gauge) |
| Temperature Range | 105–130 °C |
| Humidity Range | 85–100 % RH |
| Control Method | PID-controlled steam saturation with real-time pressure/temperature/humidity feedback |
| Compliance | Designed per JIS C 60068-2-66, JEDEC JESD22-A110, MIL-STD-202G Method 108, and IEC 60068-2-66 |
| Interface | RS-485, Ethernet (Modbus TCP), optional USB and SD card slot for data logging |
| Brand | HIRAYAMA |
|---|---|
| Origin | Japan |
| Model | PC-304R9 / PC-422R9 / PC-304R9D / PC-422R9D |
| Chamber Capacity | 304 L / 422 L |
| Dual-Chamber Configuration | Standard (PC-R9D models) |
| Pressure Range | Up to 300 kPa (gauge) |
| Temperature Range | +105 °C to +130 °C |
| Humidity Control | 85–100 % RH |
| Remote Operation | Ethernet & USB interface |
| Data Logging | Internal memory + external USB storage |
| Compliance | JEDEC JESD22-A110, JESD22-A118, IEC 60068-2-66, MIL-STD-883 Method 1007 |
| Cooling System | Integrated chilled water reservoir with automatic drain function |
| Electrochemical Migration (ECM) Evaluation Mode | Built-in electrolyte residue monitoring and purge cycle |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HY-764A |
| Price | Upon Request |
| Sample Turntable Diameter | Φ450 mm |
| Turntable Speed | 1–5 rpm (adjustable) |
| Test Chamber Dimensions | 500 × 500 × 600 mm (W × D × H) |
| UV Wavelength Range | 280–400 nm |
| UV Irradiance | (25 ± 0.4) W/m² |
| Operating Temperature Range | Ambient to 200 °C |
| Insulation Material | Glass Fiber |
| Heating Method | Forced-Air Circulation |
| Control System | Independent lamp and chamber heating control |
| UV Intensity Adjustment | Via front-panel digital interface |
| Timer | LCD digital timer, 0–24 h |
| Drive Motor | AC 220 V, 200 W |
| Test Lamp | German-made 300 W infrared bulb |
| Calibration Certificate | CNAS-accredited calibration report included |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HY-764B |
| Pricing | Upon Request |
| Timer | LCD digital, 0–24 h range |
| UV Source | Two 15 W fluorescent UV lamps |
| UV Wavelength Range | 280–400 nm |
| Internal Chamber Dimensions | 50 × 30 × 35 cm (L × W × H) |
| Calibration Certificate | ISO/IEC 17025-accredited CNAS calibration report included |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 3,950 (FOB) |
| Temperature Range | 105–132 °C (Control Point) |
| Temperature Uniformity | ±2.0 °C |
| Temperature Stability | ±0.5 °C |
| Humidity Range | 75–100% RH (Control Point) |
| Humidity Stability | ±2.5% RH |
| Humidity Uniformity | ±5.0% RH |
| Pressure Range | 0.05–0.196 MPa (0.5–2.0 kgf/cm²) |
| Ramp Time (Ambient → 132 °C) | ≤35 min |
| Pressure Ramp Time (Atmospheric → 2.0 kgf/cm²) | ≤40 min |
| Cooling System | Dual-Circuit Refrigeration with Eco-Friendly Refrigerant (R-404A or R-507) |
| Condenser Type | Air-Cooled with Forced-Air Heat Dissipation or Optional Water-Cooled Coil |
| Vacuum Preconditioning | Integrated Vacuum Pump with Filtered Air Recharge |
| Control Interface | LED Digital Timer with Start-on-Temp Trigger Logic |
| Safety | Dual-Limit Over-Temp/Over-Pressure Protection, Fault Indicator LEDs, Auto-Shutdown on Anomaly |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 3,500 (approx.) |
| Compliance Standards | MIL-STD-810G Method 512.6 (Rain), IEC 60529 IPX1–IPX6, ISO 20653, GB/T 4208, GB/T 2423.38, GJB 150.8, IEC 60068-2-68, GB/T 4942.1, IEC 60034-5 |
| Chamber Construction | SUS304 Stainless Steel Interior |
| Insulation | Rigid Polyurethane Foam + Glass Fiber |
| Turntable | PVC Hardboard Surface (Corrosion-Resistant) |
| Water-Contact Components | Stainless Steel or Brass |
| Control System Options | Programmable Logic Controller (PLC) or Full-Color Touchscreen HMI (proprietary developed) |
| Oscillation Mechanism | Stepper Motor-Driven Swing Pipe with Adjustable Angle & Sweep Rate |
| Nozzle Layout | Radial Arrangement Centered on Turntable Axis |
| Post-Test Drying | Compressed Air Blow-Off |
| Water Level | Motorized Auto-Adjustment |
| Spray System | High-Pressure Pump + Heated Spray Nozzles |
| External Casing | 1.2 mm Cold-Rolled A3 Steel, CNC Formed, Powder-Coated Finish |
| Noise Level | <65 dB(A) |
| Energy Efficiency | Optimized Thermal Management & Duty-Cycle Control |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-545-M |
| Temperature Range | –100 °C to +300 °C |
| Ramp Rate | Up to 18 °C/s |
| Temperature Accuracy | ±1.0 °C |
| Operating Modes | Air Mode & DUT Mode (Device-Under-Test Mode) |
| Thermocouple Interface | Type T |
| Compliance | Designed for semiconductor ATE integration (e.g., Advantest memory testers) |
| Application Focus | Non-volatile memory thermal qualification (NOR/NAND Flash, eMMC) |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-545-M-k |
| High Temp Range | 0 to 225 °C |
| Low Temp Range | −75 to 0 °C |
| Thermal Shock Range | −75 to +225 °C (50 Hz) |
| Temperature Stability | ±1 °C |
| Ramp Rate (Heating) | ≤10 s from −55 to +125 °C |
| Ramp Rate (Cooling) | ≤10 s from +125 to −55 °C |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-710E |
| High-Temperature Range | 0 to 225 °C |
| Low-Temperature Range | −80 to 0 °C |
| Thermal Shock Range | −80 to +225 °C |
| Temperature Stability | ±1 °C |
| Heating Rate | ~10 s from −55 °C to +125 °C |
| Cooling Rate | ~10 s from +125 °C to −55 °C |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | inTEST ATS-710E |
| Quotation | Upon Request |
| High-Temperature Range (°C) | +225 |
| Low-Temperature Range (°C) | −75 |
| Thermal Shock Range (°C) | −75 to +225 (50 Hz) |
| Temperature Stability (°C) | ±0.1 °C |
| Heating Rate (°C/min) | −55 to +125 °C in ~10 s |
| Cooling Rate (°C/min) | +125 to −55 °C in ~10 s |
| Airflow Output | 4–18 scfm (1.8–8.5 L/s) |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Display Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Remote Interfaces | Ethernet, IEEE-488 (GPIB), RS-232 |
| Control Interface | Touchscreen HMI with embedded real-time OS (Windows-free architecture) |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-770E |
| High Temperature Range | +225°C |
| Low Temperature Range | -95°C |
| Thermal Shock Range | -95°C to +225°C |
| Temperature Stability | ±0.01°C |
| Ramp Rate (Heating) | -55°C to +125°C in <10 s |
| Ramp Rate (Cooling) | +125°C to -55°C in <10 s |
| Airflow Capacity | 4–12 scfm (1.8–5.6 L/s) |
| Temperature Display Resolution | ±1°C |
| Temperature Display Accuracy | ±1°C (NIST-traceable calibration) |
| Control Interface | Touchscreen HMI |
| Communication Protocols | Ethernet, IEEE-488 (GPIB), RS-232 |
| Operating Modes | Air Mode, DUT Mode (T-type or K-type thermocouple support) |
| Compliance | CE-marked, CFC-free, GLP/GMP-ready architecture |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor (Imported) |
| Model | BT28 |
| High Temperature Range | +125°C |
| Low Temperature Range | −10°C |
| Thermal Shock Range | −10°C to +125°C |
| Temperature Stability | ±0.1°C |
| Heating Rate | −10°C to +125°C in ≤10 s |
| Cooling Rate | +125°C to −10°C in ≤10 s |
| Airflow Output | 14 scfm |
| Temperature Accuracy | ±1.0°C (NIST-traceable calibration) |
| Temperature Resolution | 0.1°C |
| Sensor Type | T-type or K-type thermocouple |
| Remote Interfaces | Ethernet, IEEE-488 (GPIB), RS-232, USB Serial |
| Overtemperature Protection | Factory-set at +225°C (user-configurable limits) |
| Dimensions (W×D×H) | 35.4 × 59.5 × 42.5 cm (base) |
| Weight | 38.3 kg (system), 31.8 kg (without arm/head) |
| Noise Level | <60 dBA (operational), <50 dBA (standby) |
| Refrigerant | Non-ozone-depleting, non-toxic, non-flammable blend |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ECO-710E |
| High Temp Range | +225 °C |
| Low Temp Range | −80 °C |
| Thermal Shock Range | −80 to +225 °C |
| Temperature Stability | ±0.1 °C |
| Ramp Rate (−55 to +125 °C) | ~10 s |
| Ramp Rate (+125 to −55 °C) | ~10 s |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-505 |
| Temperature Range | –20 °C to +225 °C |
| Ramp Rate | Up to 18 °C/s (heating/cooling) |
| Temperature Accuracy | ±1 °C |
| Control Interface | Rotary Knob Panel |
| Cooling Method | Compressed Dry Air + Integrated Refrigeration Unit |
| Heating Method | Resistive Heated Air Stream |
| Safety Protection | Adjustable Over-Temperature Cutoff (factory default: +230 °C) |
| Form Factor | Benchtop |
| Brand | inTEST-Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-535 |
| High Temperature Range | +225°C |
| Low Temperature Range | -60°C |
| Thermal Shock Range | -60°C to +225°C |
| Temperature Stability | ±0.1°C |
| Ramp Rate (Heating) | -40°C to +125°C in <12 s |
| Ramp Rate (Cooling) | +125°C to -40°C in <40 s |
| Airflow Output | 5 SCFM (2.4 L/s) |
| Temperature Resolution | ±0.1°C |
| Temperature Accuracy | ±1.0°C (NIST-traceable calibration) |
| DUT Sensor Support | Type T & K Thermocouples |
| Refrigerant | CFC-free, non-toxic, non-flammable |
| Power Supply (Chiller) | 220 VAC ±10%, 50/60 Hz, 16 A |
| Power Supply (Compressor) | 220 VAC ±10%, 50/60 Hz, 30 A |
| Dimensions (H×W×D) | 194.7 × 61.7 × 108.6 cm |
| Weight | 249.5 kg |
| Noise Level | <70 dBA |
| Compliance | CE, RoHS, FDA 21 CFR Part 11-ready data logging |
| Brand | inTEST Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-535-S-7 |
| Temperature Range | -80°C to +225°C |
| Cooling/Heating Method | Compressed Dry Air with Integrated Refrigeration & Resistive Heating |
| Thermal Transition Rate | Up to 150°C/min (typical, dependent on DUT thermal mass and fixture) |
| Control Accuracy | ±1°C |
| Compliance | Designed for ASTM F2069, IEC 61340-5-1, Telcordia GR-468-CORE, and JEDEC JESD22-A104 environmental stress screening protocols |
| Brand | inTEST-Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-545-M |
| Temperature Range | –80°C to +225°C |
| Cooling/Heating Method | Compressed Dry Air with Integrated Refrigeration & Resistive Heating |
| Control Interface | Rotary Knob Panel with Real-Time Sensor Feedback |
| Over-Temperature Protection | Factory-Set at +230°C, User-Configurable Limit |
| Form Factor | Mobile Benchtop Unit Compatible with Robotic Handler Integration |
| Compliance | Designed for GLP/GMP-aligned test environments |
| Brand | inTEST Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-545-M |
| Temperature Range | –80°C to +225°C |
| Cooling/Heating Medium | Compressed Dry Air |
| Control Mode | Air Mode (Direct Air Delivery) |
| Safety Features | Dual-Stage Over-Temperature Protection (Factory-Set Max +230°C, User-Configurable Limits) |
| Form Factor | Mobile Benchtop Unit |
| Compliance | Designed for ISO/IEC 17025-aligned test environments, supports GLP/GMP audit trails when integrated with validated software platforms |
| Interface | Integrated touchscreen HMI with real-time temperature logging and setpoint programming |
| Brand | inTEST Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-545-M-7 |
| Temperature Range | -80°C to +225°C |
| Temperature Stability | ±1°C |
| Thermal Shock Range | -80°C to +225°C |
| Cooling/Heating Method | Compressed Dry Air with Integrated Refrigeration & Resistive Heating |
| Operating Mode | Air-Based Localized Thermal Streaming |
| Brand | inTEST Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-545-T |
| Temperature Range | −80 °C to +225 °C |
| Airflow Output | 4–18 scfm (1.8–8.5 L/s) |
| Transition Rate | <10 s from −55 °C to +125 °C and vice versa |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Remote Interface | IEEE-488 (GPIB), RS-232 |
| Dimensions (W×D×H) | 61 × 72.4 × 108 cm |
| Weight | 236 kg |
| Operating Height Range | 69.1–130.3 cm (extendable to 81.3–188 cm) |
| Noise Level | <65 dBA |
| Brand | inTEST Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-710 |
| Temperature Range | −80 °C to +225 °C |
| Transition Rate | <10 s (−55 °C ↔ +125 °C) |
| Airflow Capacity | 4–18 scfm (1.8–8.5 L/s) |
| Temperature Resolution & Accuracy | ±1 °C (NIST-traceable calibration) |
| Control Interface | Touchscreen HMI |
| Remote Interfaces | IEEE-488 (GPIB), RS-232 |
| Operating Modes | Air Mode, DUT Mode (T-type or K-type thermocouple support) |
| Compliance | CE, RoHS, CFC-free |
| Optional Configurations | ATS-710-M (robotic arm), ATS-710-H (extended-height arm), ATS-710-T (test chamber) |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-710E |
| Temperature Range | −80 °C to +225 °C |
| Temperature Stability | ±0.01 °C |
| Ramp Rate | ~10 s from −55 °C to +125 °C |
| Ramp Rate | ~10 s from +125 °C to −55 °C |
| Airflow Output | 4–18 SCFM (1.8–8.5 L/s) |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Control Interfaces | Ethernet, IEEE-488 (GPIB), RS-232 |
| Chiller | Non-ozone-depleting refrigerant, LN₂-free, LCO₂-free |
| Dehumidification | Dry-air purge (0.5–3 SCFM) |
| Safety Limits | User-configurable thermal cutoff up to +230 °C |
| Dimensions (W×D×H) | 61.0 × 72.4 × 108.0 cm |
| Net Weight | 236 kg |
| Enclosure Options | 4.5″ or 5.5″ ThermoStream® hood with cryo-rated gasket |