Environmental Test Chamber
Filter
Showing 1681–1710 of 2010 results
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illumination), 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Irradiance | 200 ± 8 W/m² |
| Spectral Range | 295–450 nm |
| Irradiance Uniformity | ≥90 % |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50 ± 10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Time | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray | 500 × 400 mm |
| Irradiation Geometry | Top-mounted, Direct Reflective Illumination |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance | 200 ± 8 W/m² (broadband, 295–450 nm) |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| IR Filter | Optional 30% infrared energy rejection filter |
| Irradiance Monitoring | LCD-based Cumulative Irradiance Integrator |
| Cooling Method | Internal Forced-Air Circulation System |
| Irradiance Uniformity | ≥90% across sample plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Heating Time | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Configuration | Top-mounted, Reflective Direct Illumination |
| Irradiance Uniformity | ≥90% |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance Level | 200 ± 8 W/m² |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (developed by China Academy of Engineering Physics – Institute 622) |
| IR Filter | Optional 30% Infrared Energy Blocking Filter |
| Irradiance Monitoring | LCD-Based Cumulative Irradiance Integrator with Real-Time Calculation |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,000 (FOB) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (Single) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-Mounted Reflector-Based Direct Illumination |
| Spectral Range | 295–450 nm |
| Irradiance Level | 200 ± 8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90% across rack surface |
| UV Monitoring | Integrated UV Spectral Irradiance Transmitter (developed by China Academy of Engineering Physics – Institute 622) |
| Filter System | Custom High-Borosilicate Glass + IR-Blocking Filter (removes ~30% infrared energy) |
| Control Interface | LCD-based Irradiance Accumulation Meter with Real-Time Dose Integration |
| Cooling Method | Internal Forced-Air Circulation System |
| Compliance | Designed per ISO 4892-2, ASTM G155, SAE J2527, and GB/T 16422.2 requirements |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Source | Air-Cooled Metal Halide Lamp(s) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90% |
| Black Panel Temperature Range | 40–85 °C |
| Cooling Method | Internal Forced-Air Circulation |
| Filter | Custom High-Borosilicate Glass (IR-Reduction ~30%) |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (calibrated per ISO 4892-2) |
| Control Display | LCD-Based Irradiance Integration & Cumulative Dose Monitoring |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Sample Capacity | 500 × 400 mm Test Tray |
| Irradiation Source | Air-Cooled Metal Halide Lamp(s) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Uniformity | ≥90% across Exposure Plane |
| Cooling Method | Internal Forced-Air Circulation |
| Filter | Custom High-Borosilicate Glass + Optional IR-Reduction Filter (30% IR attenuation) |
| UV Monitoring | Integrated Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| Control Interface | LCD-Based Irradiance Accumulation Meter with Real-Time Dose Integration |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Temperature Range | RT to 85 °C (Operating Range: 50 ±10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Irradiation Geometry | Top-Mounted Reflector-Based Direct Illumination |
| Spectral Output | 295–450 nm (UV-A/UV-B/Visible) |
| Irradiance Uniformity | ≥90 % across Sample Plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Temperature Range | RT to 85°C (operational test temp: 50 ± 10°C) |
| Humidity Range | 40–70% RH (lighting), 50–90% RH (dark cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW air-cooled metal halide lamp (1 unit) |
| Sample Rack | 500 × 400 mm stainless steel rack |
| Irradiation Geometry | Top-mounted, direct-reflection configuration |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90% across exposure area |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50°C ±10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Irradiance | 200 ±8 W/m² (295–450 nm) |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance Uniformity | ≥90% |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (Calibrated per ISO 17025 Traceable Standards) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted lamp with reflective direct irradiation |
| Spectral Range | 295–450 nm (UV-A/UV-B broadband) |
| Irradiance Level | 200 ± 8 W/m² |
| UV Radiometer | Integrated Spectral UV Irradiance Transmitter (developed by China Academy of Engineering Physics, Institute 622) |
| IR Filtering | Optional 30 % infrared energy rejection filter (custom order required) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50°C ±10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted, Reflector-Assisted Direct Illumination |
| Spectral Range | 295–450 nm |
| Irradiance Uniformity | ≥90% across Exposure Plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Key Features | Temperature Range: RT to 85°C (Operating Range: 50 ±10°C) |
|---|---|
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | RT → 85°C in ≤25 min |
| Light Source | Single 2.5 kW Air-Cooled Metal Halide Lamp |
| Spectral Output | 295–450 nm (UV–Visible) |
| Irradiance at Sample Plane | 200 ±8 W/m² |
| Irradiance Uniformity | ≥90% |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| Compliance | Designed per ISO 4892-2, ASTM G154, IEC 60068-2-5, and GB/T 16422.2 |
| Brand | Tuofeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TF-360A |
| Price Range | USD 14,000 – 28,500 (FOB Shanghai) |
| Internal Dimensions (D×W×H) | 2.0 m × 2.0 m × 2.0 m |
| Temperature Range | −70 °C to +100 °C |
| Temperature Uniformity | ±2.0 °C |
| Humidity Range | 20–98 %RH |
| Humidity Uniformity | ±5 %RH |
| Temperature Control Accuracy | ±0.3 °C |
| Humidity Control Accuracy | ±2 %RH |
| Heating Rate | 1.0–3.0 °C/min |
| Cooling System | Twin-stage cascade refrigeration with Tecumseh (France) compressors |
| Humidification Method | Surface evaporation type |
| Dehumidification Method | ADP (Air Dew Point) critical-point cooling |
| Insulation Material | High-density polyurethane foam (≥150 mm thick) |
| Interior Material | SUS#304 stainless steel |
| Exterior Material | Cold-rolled steel with powder-coated finish |
| Air Circulation | Multi-wing centrifugal blower + optimized ducted airflow system |
| Viewing Window | Multi-layer low-E heated laminated glass |
| Safety Protections | Over-temperature cut-off, phase sequence protection, compressor high-pressure/overload/over-current protection, fan overload protection, water shortage protection, humidifier dry-run protection, emergency stop, and internal distress alarm |
| Power Supply | 380 VAC, 3-phase, 50 Hz |
| Brand | Tuofeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TF-360B |
| Price Range | USD 14,000 – 28,000 (FOB Shanghai) |
| Internal Dimensions (D×W×H) | 2.5 m × 3.0 m × 2.0 m |
| Temperature Range | −70 °C to +100 °C |
| Temperature Uniformity | ±2.0 °C |
| Humidity Range | 20–98% RH |
| Humidity Uniformity | ±5% RH |
| Temperature Control Accuracy | ±0.3 °C |
| Humidity Control Accuracy | ±2% RH |
| Heating Rate | 1.0–3.0 °C/min |
| Cooling System | Tecumseh (France) Hermetic Compressor |
| Humidification Method | Surface Evaporation |
| Dehumidification Method | ADP (Adiabatic Dew Point) Refrigerated Cooling |
| Air Circulation | Multi-blade Centrifugal Fan + Optimized Air Duct Design |
| Insulation | High-Density Polyurethane Foam (≥150 mm) |
| Interior Material | SUS#304 Stainless Steel |
| Exterior Material | Powder-Coated Cold-Rolled Steel |
| Observation Window | Multi-layer Low-E Heated Glass |
| Safety Protections | Over-temperature, Leakage Current, Low-Water, Compressor High-Pressure/Overload/Overcurrent, Fan Overload, Phase Sequence Monitoring, Emergency Indoor Alarm |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (approx.) |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -40°C to +150°C (empty load) |
| Humidity Range | 20–98% RH |
| Temperature Stability | ±0.3°C |
| Humidity Accuracy | +2 / -3% RH |
| Temperature Uniformity | ±2.0°C |
| Heating Rate | ~10 min (20°C → 150°C) |
| Cooling Rate | ~30 min (20°C → -20°C) |
| Internal Dimensions | 1000 × 1000 × 1000 mm (L×W×H) |
| External Dimensions | 1700 × 1450 × 1850 mm (L×W×H) |
| Inner Liner | Mirror-finish SUS#304 stainless steel |
| Outer Casing | Brushed-finish SUS#304 stainless steel |
| Insulation | High-density rigid PU foam + 24K glass wool |
| Refrigeration System | Hermetically sealed French Tecumseh compressor |
| Refrigerant | Eco-friendly R-404A or equivalent |
| Control System | Touchscreen HMI with bilingual (EN/CN) interface, 120 programs × 1200 segments, PID + BTHC (Balance Thermal & Humidity Control) algorithm |
| Sensor | Dual PT-100 platinum resistance thermometers |
| Resolution | 0.1°C / 0.1% RH |
| Data Logging | Built-in runtime counter, fault diagnostics, and event-triggered alarm history |
| Key | Temperature Range: -70°C to +150°C |
|---|---|
| Humidity Range | 20–98% RH |
| Temp. Uniformity | ±1.5°C |
| Temp. Stability | ±0.5°C |
| Humidity Uniformity | ±3% RH |
| Humidity Stability | ±2% RH |
| Heating Rate | ~3°C/min (avg.) |
| Cooling Rate | ~1°C/min (avg.) |
| Internal Dimensions | 50 × 60 × 50 cm (W×H×D) |
| External Dimensions | 102 × 147 × 108 cm (W×H×D) |
| Construction | SUS304 Stainless Steel Interior |
| Insulation | Rigid Polyurethane Foam + Glass Wool |
| Refrigeration System | Dual-Stage Cascade (R404A/R23) |
| Control System | TEMI Programmable PID+SSR Microprocessor Controller |
| Compressor Type | Hermetic or Semi-Hermetic (Imported OEM Units) |
| Critical Components | Sporlan Expansion Valves & Filters, Castel Solenoid Valves, Alco Oil Separators, Ranco Pressure Controls |
| Cooling Method | Air-Cooled or Water-Cooled (Optional for High-Capacity Units) |
| Defrost Mode | Automatic & Manual Cycles |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Standards Compliance | IEC 60068-2-14, MIL-STD-810G Method 503.5, ASTM D6987, GB/T 2423.22–2022, GJB 150.5A–2009, QC/T 17–1992, EIA-364-32 |
| Cooling System | Dual-Stage Cascade Refrigeration (Water-Cooled) |
| Temperature Range | –65 °C to +180 °C |
| Transition Time (Typ.) | ≤30 s (–65 °C ↔ +180 °C) |
| Internal Volume Options | 150 L, 300 L, 500 L, 800 L |
| Control Accuracy | ±0.5 °C (Steady State), ±2.0 °C (Transition) |
| Humidity Control | Not Applicable (Dry Thermal Shock Only) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling Capacity | Dual-Stage Cascade Refrigeration System with German Semi-Hermetic Compressors |
| Cooling Water Requirement | 10 m³/h External Cooling Tower (User-Supplied) |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2012, QC/T 17-1992, EIA-364-32 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling System | Dual-Stage Cascade Refrigeration with German Semi-Hermetic Compressors |
| Cooling Water Requirement | 10 m³/h External Cooling Tower |
| Temperature Range | −65°C to +200°C |
| Transition Time (Typical) | ≤15 s between Chambers |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2012, QC/T 17-1992, EIA-364-32 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | −65 °C to +180 °C |
| Transition Time (Typical) | ≤15 s between chambers |
| Shock Cycle Count | 1–9999 programmable |
| Dwell Time per Zone | 0.1–999.9 h |
| Data Logging Interval | 3 s to 1 h |
| Storage Capacity | 120 days @ 60 s sampling |
| Compliance | GB/T 2423.1–2008 (Test A), GB/T 2423.2–2008 (Test B), GB/T 10592–2008, GJB 150.3–1986, GJB 360A–1996 Method 107 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling System | Twin-Stage Cascade Refrigeration with German Semi-Hermetic Compressors |
| Cooling Water Requirement | 10 m³/h External Cooling Tower |
| Compliance | GB/T 2423.1/2/22, GJB 150.3–150.5, IEC 60068-2-14, US MIL-STD-810G Method 503.5, ASTM D648, ISO 11359-2 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | –70°C to +180°C |
| Shock Transition Time (5%–95%) | ≤15 s (between zones) |
| Cycle Count Range | 1–9999 cycles |
| Dwell Time per Zone | 0.1–999.9 h |
| Control System | PID-based LED Touch HMI with Real-Time Curve Display |
| Compliance | ASTM D573, ISO 16750-4, IEC 60068-2-14, MIL-STD-810H Method 503.5 |
| Cooling System | Twin-stage cascade refrigeration (R404A/R23), equipped with French Tecumseh compressors |
| Defrost Mode | Automatic or Manual, programmable frequency |
| Structural Design | Explosion-proof ergonomic handles, insulated stainless-steel chamber walls, dual- or tri-zone configuration (selectable) |