- All
- Favorite
- Popular
- Most rated
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec™ Sofia |
| Instrument Type | Portable Near-Infrared Spectrometer |
| Wavelength Range | 850–1050 nm |
| Measurement Mode | Transmission NIR |
| Analysis Time | ~3 minutes for 10 subsamples |
| Dimensions (W × D × H) | 255 × 390 × 295 mm |
| Weight | 9 kg |
| Operating Temperature | 0–45 °C |
| Storage Temperature | −20–70 °C |
| Relative Humidity | <93% RH (non-condensing), up to 100% cyclic |
| Power Supply | 100–240 V AC, 50–60 Hz, Class I with earth grounding |
| EMC Environment | Light industrial, agricultural & mobile machinery |
| Sample Preparation | None required (whole-grain analysis) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MeatScan |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating-based non-scanning array detector |
| Wavelength Range | 850–1050 nm |
| Scan Time | 45 seconds per sample (including 15 subsamples) |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Artificial Neural Network (ANN)-based calibration |
| Sample Form | Homogenized meat mince (pork, poultry, beef, lamb) |
| Output Parameters | Fat content (%), Moisture content (%) |
| Weight | 12 kg |
| Compliance | Designed for GLP-compliant environments |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS™ DS2500 L |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Time | <40 s per sample |
| Data Sampling Interval | 10 s |
| Measurement Mode | Transmission (for liquids) |
| Chemometrics Software | WinISI |
| IP Rating | IP54 |
| Temperature Control | Automatic, Closed-Loop Sample Thermal Regulation |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | ProFoss™ 2 Online Soybean Meal Analyzer |
| Instrument Type | Online Near-Infrared Spectrometer |
| Principle | Grating-based diode array (non-scanning) NIR spectroscopy |
| Wavelength Range | 1100–1650 nm |
| Analysis Time per Result | 2–3 seconds (real-time) |
| Sampling Mode | Diffuse reflectance and/or transmission |
| Chemometrics Software | ISIscan NOVA™ Instrument Control |
| Data Acquisition Interval | 2–3 seconds (real-time) |
| Compliance Ready | Designed for integration with industrial process control systems (OPC UA/DA), supports audit-ready data logging per GLP/GMP-aligned workflows |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DS3 F |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Principle | Grating Scanning |
| Wavelength Range | 850–2500 nm |
| Scan Speed | <1 minute per sample |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | WinISI with Artificial Neural Network (ANN) algorithms |
| Enclosure Rating | IP65 |
| Cooling System | Closed-Loop Liquid Cooling |
| Sample Interface | RFID-Enabled Sample Cups |
| Factory Calibration Strategy | Pre-Standardized, Inter-Instrument Transferable Calibration |
| Language Options | English or Chinese UI & Network Management Software |
| Compliance Support | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready audit trail capabilities in WinISI |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | ProFoss™ 2 Online Feed Analyzer |
| Instrument Type | Online Near-Infrared Spectrometer |
| Optical Principle | Grating-based non-scanning diode array detector |
| Wavelength Range | 1100–1650 nm |
| Analysis Speed | Real-time |
| average analysis time per result | 2–3 seconds |
| Sampling Interval | Real-time |
| Measurement Mode | NIR transmission/reflection (process-integrated) |
| Chemometrics Software | ISIscan NOVA™ Instrument Control Software |
| Sample Interface | Direct-coupled flow-through window, no bypass required |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | FoodScan 2 |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Design | Grating Scanning System |
| Wavelength Range | 400–1100 nm |
| Sample Throughput | 15–25 seconds per sample |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Transmission and Reflectance |
| Chemometric Software Engine | Artificial Neural Network (ANN) Calibration |
| Regulatory Certification | AOAC Official Method of Analysis™ 983.18 |
| Application Scope | Raw and processed meat, poultry, and aquatic products (porcine, bovine, avian, etc.) |
| Key Analytes | Fat, Protein, Moisture, Collagen, Salt (Cl⁻ basis), Lean Meat Content |
| Optional Extensions | Saturated Fatty Acids, Ash, Sodium-based Salt, Water Activity, Color Parameters |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DA1650 |
| Instrument Type | Laboratory Benchtop |
| Optical Principle | Grating-based Diode Array Scanning |
| Wavelength Range | 1100–1650 nm |
| Scan Time | 1 minute per spectrum |
| Data Sampling Interval | 0.5 nm |
| Measurement Modes | Diffuse Reflectance, Transmission (for liquids) |
| Chemometrics Software | WinISI |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec Grain & Flour |
| Instrument Type | Laboratory Near-Infrared Spectrometer |
| Principle | Grating-based Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 60 scans/sec |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | ANN (Artificial Neural Networks), PLS (Partial Least Squares) |
| Path Length Control | Motorized, 6–33 mm auto-adjustable |
| Subsample Capacity | 1–30 (standard: 10) |
| Analysis Time | 60 s (10 subsamples, including bulk density) |
| Compliance | EN 15948, IP54 dust- and splash-resistant enclosure |
| Patents | US 4,944,589 |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DS3 |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Speed | <1 minute per sample |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | WinISI with Artificial Neural Network (ANN) algorithms |
| Enclosure Rating | IP65 |
| Cooling System | Closed-Loop Liquid Cooling |
| Sample Identification | RFID-Enabled Sample Cups |
| Factory Calibration Strategy | Inter-instrument Transferable Standardization |
| Language Options | English or Chinese GUI (configurable) |
Show next