| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | ProFoss™ 2 |
| Automation | Fully Automatic |
| Analysis Time | 3–15 seconds per sample |
| Wavelength Range | 850–1050 nm |
| Wavelength Accuracy | < 0.5 nm |
| Wavelength Precision | < 0.02 nm |
| Wavelength Stability | < 0.01 nm/°C |
| Detector | Silicon Diode Array |
| Spectral Resolution | 1.0 nm/pixel |
| Light Source Lifetime | Dual Lamp System = 17,500 h |
| Environmental Rating | IP69K |
| Operating Temperature | –5 to 40 °C |
| Enclosure Material | Stainless Steel EN 1.4301 (SS2333) |
| Dimensions (W × H × D) | 42 × 42 × 13.5 cm |
| Weight | 25 kg |
| Communication Interfaces | Ethernet, OPC UA, 4–20 mA, PROFIBUS, RINA |
| Power Supply | 100–240 VAC, 50–60 Hz, 2.0 A, 150 W |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | DairyScan |
| Automation | Fully Automatic |
| Analysis Time | 45 seconds per sample (15 sub-samples per run) |
| Measurement Range | Fat 0–36% w/w |
| Repeatability | ≤0.25% CV |
| Accuracy | ≤1.0% CV |
| Detection Principle | Near-Infrared (NIR) Transmission Spectroscopy |
| Sample Throughput | Up to 80 samples/hour (typical operational rate) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fossomatic 7 |
| Automation Level | Fully Automatic |
| Analysis Speed | Up to 600 samples/hour |
| Detection Range | 0–10 × 10⁶ cells/mL |
| Repeatability | CV < 4% at 500,000 cells/mL |
| Accuracy | < 10% deviation vs. direct microscopic count |
| Technology | Flow Cytometry |
| Compliance | ISO 13366-1, IDF 148, FDA/NCIMS Grade A Standards |
| Software Platform | Foss Integrator NOVA |
| Sample Types | Bovine, ovine, caprine, and buffalo milk |
| Configuration Options | Fossomatic 7 (total SCC) and Fossomatic 7 DC (somatic cell differential counting) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | CombiFoss 7 |
| Automation Level | Fully Automatic |
| Analysis Throughput | 600 samples/hour |
| Somatic Cell Count (SCC) Range | 0–10 × 10⁶ cells/mL |
| Repeatability | < 2% CV |
| Accuracy | ±0.1–1.5 × 10⁶ cells/mL |
| Sample Temperature Range | 30–42 °C |
| Regulatory Compliance | Designed for ISO 8570, IDF 141, AOAC 991.19, and EU Regulation (EC) No 853/2004 compliance |
| Detection Capabilities | Fat, Protein, True Protein, Lactose, Total Solids, Non-Fat Solids, Urea, Citric Acid, Freezing Point, Casein, Free Fatty Acids, pH, Monounsaturated Fatty Acids (MUFA), Polyunsaturated Fatty Acids (PUFA), Total Unsaturated Fatty Acids, Total Saturated Fatty Acids, Sample Inlet Temperature, Somatic Cell Count (with FM FC module) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Milkoscan Mars |
| Automation | Fully Automatic |
| Analysis Time | 1 min per sample |
| Measurement Parameters | Fat, Protein, Lactose, Total Solids, Non-Fat Solids |
| Repeatability | ≤0.5% CV (for raw milk major components) |
| Accuracy | ≤1.2% CV (for raw milk major components) |
| Technology | Fourier Transform Infrared (FTIR) Spectroscopy |
| Compliance | Designed for ISO 9001–certified dairy QA/QC environments |
| Screening Capability | Pre-installed ASM (Adulterant Screening Module) models for urea, sucrose, formaldehyde, sodium bicarbonate, potassium nitrate, and other common adulterants |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MilkoScan™ FT2 |
| Automation | Fully Automatic |
| Analysis Time | 30 s |
| Sample Volume Range | 4–25 mL |
| Repeatability | <0.2% CV (for fat, protein, lactose, total solids, SNF in raw milk) |
| Accuracy | <0.8% CV (for fat, protein, lactose, total solids, SNF in raw milk) |
| Operating Temperature Range | 5–55 °C |
| Carry-over | <1% |
| Optical System | Sealed, temperature-controlled FTIR interferometer |
| Calibration Methods | Intercept/slope adjustment |
| Supported Chemometric Models | PLS, modified PLS, PCA |
| Compliance | CE-marked |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | CombiFoss 7 |
| Automation | Fully Automatic |
| Analysis Speed | Up to 600 samples/hour |
| Fat Detection Range | 0–15% |
| Repeatability (CV) | <0.5% |
| Fat Precision (CV) | <1.0% |
| Sample Types | Bovine, Ovine, Caprine, and Buffalo Milk |
| Key Parameters | Fat, True Protein, Crude Protein, Casein, Lactose, Total Solids, Non-Fat Solids, Urea, Citric Acid, Free Fatty Acids, Fatty Acid Profile, Freezing Point, pH, Ketosis Screening (BHB & Acetone), Adulteration Detection, Somatic Cell Count (SCC), Differential Somatic Cell Count (DSCC) |
| Brand | FOSS |
|---|---|
| Country of Origin | Denmark |
| Model | MilkoScan FT3 |
| Detection Parameters | Fat, Protein, Lactose, Total Solids, Non-Fat Solids, Freezing Point, Titration Acidity, Density, Free Fatty Acids, Citric Acid, Casein, Urea, Sucrose, Glucose, Fructose, Galactose |
| Automation Level | Fully Automatic |
| Analysis Time | 30 seconds per sample |
| Precision (CV) | < 0.25% (Fat, Protein, Lactose), < 0.20% (Total Solids), < 1 m°C (Freezing Point) |
| Sample Volume | < 8.0 mL |
| Flow System | Fully Automated Cleaning & Zeroing with Adaptive Adjustment |
| Connectivity | LIMS, FossManager™ Software |
| Dimensions | 750 × 450 × 408 mm |
| Weight | 43 kg |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | BacSomatic |
| Automation | Fully Automatic |
| Analysis Speed | 40 samples/hour |
| Detection Range | SCC: 100,000–1,500,000 cells/mL |
| IBC | 5,000,000–20,000,000 IBC/mL |
| Repeatability | SCC: CV < 3% at 500,000 cells/mL |
| Accuracy | SCC: Typical Sy,x < 0.25 log units vs. Standard Plate Count (SPC) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | BactoScan FC |
| Measurement Principle | Flow Cytometry |
| Detection Target | Total Viable Bacteria in Raw and Processed Milk |
| Detection Range (L-mode) | 2.0 × 10⁵ – 2.0 × 10⁷ IBC/mL (≈ 8.0 × 10⁴ – 1.0 × 10⁷ CFU/mL) |
| Detection Range (H-mode) | 5.0 × 10³ – 2.0 × 10⁷ IBC/mL (≈ 1.5 × 10³ – 1.0 × 10⁷ CFU/mL) |
| Throughput | 50–150 samples/hour |
| Sample Temperature Range | 2–42 °C |
| Warm-up Time | <15 min |
| Shutdown Time | <5 min |