Fume Hood
Filter
Showing 61–82 of 82 results
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | XLS392 |
| Construction | All-Steel Enclosure |
| Configuration | Double-Faced Operation |
| Airflow Capacity | 460 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Power Consumption | 105 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V DC |
| Sound Pressure Level | 55 dB(A) |
| Filter Configuration | Dual-Layer Molecular Filtration System (Class 1 per NFX 15-211) |
| External Dimensions (L×W×H) | 1000 × 790 × 1316–1500 mm |
| Internal Work Area (L×W×H) | 897 × 692 × 1014 mm |
| Lighting | IP67-rated fluorescent lamp(s), 18 W, ≥500 lux |
| Certifications | Compliant with NFX 15-211:2009 Class 1 |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | XLS483 |
| Construction | All-Steel Cabinet |
| Configuration | Double-Faced Operation |
| Airflow Capacity | 690 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (per AFNOR NF X 15-211:2009) |
| Filter System | Dual-Stage Molecular Filtration (Class 1 per NFX 15-211) |
| Power Consumption | 175 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal Control Voltage | 24 V DC |
| Noise Level | 58 dB(A) |
| Dimensions (L×W×H, mm) | 1275 × 790 × 1316–1500 (external), 1172 × 692 × 1014 (internal) |
| Lighting | IP67-rated 18 W fluorescent lamp(s), ≥500 lux |
| Compliance | AFNOR NF X 15-211:2009, NFX 15-211 Class 1, SGS & Intertek certified |
| Brand | Erlab |
|---|---|
| Origin | Germany |
| Model | XLS483W |
| Construction | Fully Steel Enclosure |
| Configuration | Double-Faced Operation |
| Airflow Capacity | 690 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009 Class 1) |
| Filtration System | Dual-layer molecular filter columns (3 filter frames total) |
| Power Input | 100–240 V AC, 50–60 Hz |
| Power Consumption | 175 W |
| Noise Level | 58 dB(A) |
| Illumination | 18 W IP67 fluorescent lamp(s), ≥500 lux at work surface |
| Safety Certification | Compliant with NF X 15-211:2009 Class 1 |
| Operating Modes | Liquid handling, liquid + particulate, powder weighing, cleanroom-compatible applications |
| Enclosure Dimensions (L×D×H, mm) | External 1275 × 790 × 1316–1500 |
| Voltage Output | 24 V DC (low-voltage control circuitry) |
| Current Draw | 1.75 A |
| Access Opening | Full-height open-face design |
| Optional Mobility | Castor-mounted trolley kit available |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | XLS633 |
| Construction | All-Steel Cabinet |
| Configuration | Double-Sided Operation |
| Airflow Capacity | 690 m³/h |
| Face Velocity Range | 0.4–0.6 m/s |
| Power Consumption | 175 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V DC |
| Sound Level | 58 dB(A) |
| Filter Configuration | Dual-Layer Molecular Filtration (Class 1 per NF X 15-211:2009) |
| Filter Housing Quantity | 3 |
| External Dimensions (L×W×H) | 1600 × 790 × 1316–1500 mm |
| Internal Dimensions (L×W×H) | 1497 × 692 × 1014 mm |
| Operating Aperture | Trapezoidal |
| Lighting | 18 W IP67 Fluorescent Lamp(s), 500 lux |
| Compliance | NF X 15-211:2009 Class 1, SGS Certified, Intertek Verified |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | XLS714 |
| Construction | All-Steel Enclosure |
| Configuration | Double-Faced Operation |
| Airflow Capacity | 920 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (per AFNOR NF X 15-211:2009) |
| Filter System | Dual-Stage Molecular Filtration (Class 1 per NFX 15-211) |
| Power Consumption | 235 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal Control Voltage | 24 V DC |
| Noise Level | 61 dB(A) |
| Dimensions (L×W×H) | 1800 × 790 × 1316–1500 mm (external), 1697 × 692 × 1014 mm (internal) |
| Lighting | IP67-rated fluorescent lamp(s), 18 W, ≥500 lux |
| Compliance | AFNOR NF X 15-211:2009, NFX 15-211 SGS-certified, TÜV/Intertek validation reports available |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Equipment |
| Model | ACD-B |
| Construction | Fully Steel Enclosure |
| Configuration | Single-Face Workstation |
| Certification | AFNOR NF X 15-203, BS 7258, BS 7989, ASHRAE 110, EN 14175-3 |
| Airflow Inflow Velocity | 0.40 m/s (80 fpm) |
| Power Supply | 220–240 V AC, 50 Hz, 1 Phase |
| Filter System | Nanocarb™ Activated Carbon Filters (7+ chemically selective variants) |
| Surface Finish | ISO-CIDE® Antimicrobial Coating |
| Control System | Esco Sentinel™ Microprocessor-Based Airflow Monitoring & Alarm Interface |
| Lighting | 5000 K Warm White Fluorescent Lamp |
| Work Surface | #304 Stainless Steel |
| Spill Containment | Front Raised Lip Design |
| Service Access | Front-Panel Maintenance Architecture |
| Optional Sensors | Integrated VOC Sensor (factory-installed) |
| Retrofit Compatibility | Air/Water/Vacuum/Gas Service Kits (DIN/BS-compliant) |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ADC-C |
| Construction | Single-Face, All-Steel Ductless Fume Hood |
| Cabinet Material | 304 Stainless Steel Work Surface, Galvanized Steel Side Walls |
| Filter System | Dual-Stage Nanocarb™ Activated Carbon with Optional Auxiliary Carbon Module |
| Airflow Inflow Velocity | 0.4 m/s |
| Compliance | ASHRAE 110, EN 14175-3, AFNOR NF X 15-203, BS 7989, BS 7258 |
| Control System | Sentinel™ Microprocessor-Based Monitoring & Alarm Interface |
| Optional Accessories | VOC Sensor, PP Sink + Gooseneck Faucet (PP), Adjustable Height Stand (SAL), Mobile Base with Braking Casters (SPC), International Power Outlets, DIN/BS-Compliant Utility Services |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ADC-E |
| Construction | Fully Steel Ductless Fume Hood |
| Configuration | Single-Face Operation |
| Airflow Inflow Velocity | 0.4 m/s |
| Filtration System | Dual-stage — Pre-filter + HEPA (99.99% @ 0.3 µm) + Nanocarb Activated Carbon Filter |
| Compliance | ASHRAE 110, EN 14175-3, AFNOR NF X 15-203, BS 7989, BS 7258 |
| Work Surface | 304 Stainless Steel |
| Side Walls | Galvanized Steel |
| Front Edge Lip | Integrated spill containment rim |
| Control System | Sentinel Microprocessor with audible/visual alarms |
| Service Access | Front-panel maintenance design |
| Optional | VOC sensor, PP sink & gooseneck faucet, height-adjustable stands, ergonomic accessories |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ADC-D |
| Construction | All-Steel, Single-Face Operation |
| Airflow Inflow Velocity | 0.4 m/s |
| Internal Work Area Dimensions (L×W×H) | 1268 × 596 × 765 mm |
| External Dimensions (L×W×H) | 1340 × 736 × 1455 mm |
| Filter Options | Nanocarb™ Activated Carbon Filters (VOC, Acid, Mercury, Sulfur, Halogen, Aldehyde, Ammonia, Ether/Chloroform) |
| Compliance | ASHRAE 110, EN 14175-3, AFNOR NF X 15-203, BS 7989, BS 7258 |
| Surface Coating | ISOCIDE™ Antimicrobial Coating |
| Control System | Sentinel™ Microprocessor-Based Controller |
| Optional Accessories | VOC Sensor, Polypropylene Sink & Faucet (PP), Adjustable Height Stand (SAL), Mobile Stand with Casters (SPC), International Power Outlets, Retrofit Utility Services (Air/Water/Vacuum/Gas) |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Micro Pte Ltd |
| Product Type | Ductless (Recirculating) Fume Hood |
| Model | SPD-A |
| Certifications | ASHRAE 110, BS 7989, BS 7258 |
| Surface Material | 304 Stainless Steel |
| Lighting | 5000K Fluorescent Lamp |
| Noise Level | 55 dBA |
| Inflow Velocity | 0.50 m/s (100 fpm) |
| Power Supply | 220–240 V AC, 50 Hz, 1Ø |
| Filter Options | Nanocarb™ Carbon Filters (7+ chemically specific variants) |
| Control System | Sentinel™ Microprocessor-Based Monitoring & Alarm |
| Optional Accessories | Mobile Base Cart (MBC-3A0 / MBC-4A0), Transparent Rear Panel, ISOCIDE® Antimicrobial Coating |
| Brand | ESCO |
|---|---|
| Origin | Singapore |
| Model | SPD-3A1 |
| External Dimensions (W×D×H) | 840 × 697 × 1110 mm |
| Airflow Capacity | 234 m³/h (138 CFM) |
| Inlet Face Velocity | 0.5 m/s (100 fpm) at work surface |
| Filter Configuration | Primary activated carbon filter bed (7-stage configurable adsorption media) + washable polyester pre-filter (20% coarse particle capture efficiency) |
| Noise Level | <55 dBA at operator position |
| Illumination | >800 lux at work surface |
| Construction | 1.2 mm electrogalvanized steel with white thermoset epoxy powder coating |
| Viewing Panel | 6 mm acrylic (frameless, front and side) |
| Work Surface Angle | 13° forward tilt |
| Control System | Sentinel™ microprocessor-based monitoring system |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | EFA |
| Pricing | Available Upon Request |
| Brand | ESCO |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | EFF-_B_ _W-_ |
| Construction | Fully Steel Cabinet |
| Configuration | Single-Face Operation |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Imported Laboratory Equipment |
| Model | EFP-_D_ _W-_ |
| Construction | All-Stainless-Steel Single-User Fume Hood |
| Surface Material | 304 Stainless Steel (optional 316 upgrade) |
| Airflow Velocity | 0.3 m/s (energy-efficient containment) |
| Certification | UL Listed (per UL 508A and UL 180, subject to configuration) |
| Compliance | ASHRAE 110:1995 tested |
| Inlet Voltage | 220–240 VAC, 50/60 Hz (or 110–120 VAC option) |
| External Width Options | 1220 mm / 1525 mm / 1830 mm / 2440 mm |
| Internal Depth | 690 mm |
| Internal Height | 1258 mm |
| Front Sash Max Opening | 740 mm |
| Sash Angle | 5° forward tilt |
| Integrated Washdown System | Yes |
| Structural Frame | Triangular wall bracing |
| Lighting | Pre-wired electronic ballast LED (>1076 lux at work surface, 0°C ambient) |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Equipment |
| Model | PPH-4UDPVW-8 / PPH-5UDPVW-8 / PPH-6UDPVW-8 / PPH-8UDPVW-8 |
| Construction Material | Full Polypropylene (PP), Metal-Free |
| Configuration | Single-Sided Front Access Fume Hood |
| External Width Options | 1200 mm, 1525 mm, 1830 mm, 2440 mm |
| Internal Depth | 665 mm |
| Internal Height | 1200 mm |
| Work Surface | Acid/Alkali-Resistant PP |
| Sash Type | Vertical or Combined Vertical-Horizontal |
| Sash Material | Tempered Polycarbonate |
| Sash Opening Angle | 5° Forward Tilt |
| Face Velocity | 0.5 m/s (meets ASHRAE 110 & EN 14175 requirements) |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Optional | Sentinel XL Airflow Monitoring System with Digital Display and Audiovisual Alarms |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | EFI-_D_ _W-_ |
| Construction | Full-Steel Fume Hood |
| Configuration | Single-User Front-Access Hood |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | labtech |
| Construction | Single-Face Full-Steel Fume Hood |
| Material | Fully Steel Cabinet Body |
| Design Features | Modular Bolt-Free Assembly, Three-Section Baffle System, Integrated Control Panel with Emergency Override, Condensate-Collecting Canopy, Logo-Style Make-Up Air Inlet, VAV-Compatible Architecture |
| Compliance Context | Designed for alignment with ISO 10974, EN 14175-3, and ANSI/ASHRAE 110 testing protocols |
| Brand | LICHEN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TFG Series |
| Price Range | USD 920 – 1,500 (FOB Shanghai) |
| Construction Material | Fully Steel Enclosure |
| Configuration | Single-Face Workstation |
| Airflow Control | Variable Air Volume (VAV) System |
| Primary Application Sector | Pharmaceutical R&D and Manufacturing |
| Exhaust Position | Top-Mounted Exhaust |
| Ducting Interface | Standard Round Duct Connection (Ø250 mm) |
| Work Area Dimensions (W×D×H) | 1630 × 700 × 600 mm |
| Overall Dimensions (W×D×H) | 1800 × 750 × 1950 mm |
| Average Face Velocity (at sash opening) | 0.26 ± 0.025 m/s |
| Exhaust Flow Rate | 1080 – 2160 m³/h (calculated from 0.3–0.6 m/s across 1.0 m² nominal face area) |
| Illumination | ≥300 lux (LED, 5000K CCT) |
| Work Surface Height | 760 mm |
| Rated Power Consumption | 800 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Sound Pressure Level | ≤65 dB(A) at 1 m distance |
| Net Weight | 250 kg |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FSE 1100 |
| Price Range | USD 2,800 – 7,000 (estimated) |
| Cabinet Material | Polypropylene (PP) |
| Configuration | Single-Face Ductless Fume Hood |
| Optional Interior Heights | 800 mm / 1100 mm |
| Pre-Filter Type | Electrostatically Charged Primary Filter |
| Main Filtration Media | Imported Activated Carbon (10 kg capacity) |
| Viewing Panel Material | Polycarbonate (PC), Fully Transparent & Modular |
| Power Requirement | Standard 220 V AC, 50 Hz |
| Fan System | Low-Noise, Energy-Efficient Centrifugal Blower |
| Airflow Mode | Recirculating (Ductless) with Dual-Stage Filtration |
| Brand | a1 |
|---|---|
| Origin | Germany |
| Model | ST1 |
| Construction | Full-steel fume hood |
| Configuration | Single-face operator access |
| Dimensions (ST1-1200) | 1200 mm W × 600 mm H × 750 mm D |
| Internal Working Depth | 640 mm |
| Airflow Control | Dual-sensor FlowTech alarm with data logging |
| Filtration Options | H13/H14 HEPA (bag-out), activated carbon for solvent capture |
| Compliance | EN 14175, ASHRAE 110, EN 1822 |
| Base Material Options | Phenolic resin, granite, or stainless steel |
| Enclosure Material | Cast acrylic (chemical-resistant) |
| Containment Validation | SafeBridge Consultants surrogate powder testing |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | FHC50 / FHM10 |
| Cabinet Type | Single-Face Chemical Fume Hood |
| Construction Material | Polypropylene (PP) |
| Compliance Standards | ANSI Z9.5, NFPA 45, OSHA 1910.145, SEFA 1.5 |
| Communication Protocols | BACnet®, LonWorks®, Modbus™ |
| Alarm Outputs | Visual (LED), Audible (85 dB), Remote Relay |
| Display | Backlit LCD with Real-Time Surface Velocity, Temperature, and Status Indicators |
| Installation Options | Surface-Mount or Flush-Mount |
| Sensor Technology | Thermal Anemometry (FHM10), Dual-Sensor Fusion (FHC50: Sash Position + Face Velocity) |
| Actuation | Fast-Response Linear Actuator for VAV Valve Control |
| Environmental Compensation | Integrated Temperature and Barometric Pressure Compensation |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | VACUU•LAN |
| Construction Material | PP (Polypropylene) |
| Cabinet Configuration | Dual-Sided Operation Fume Hood |
| Ultimate Vacuum | 2 mbar |
| Valve Options | Manual Flow Valve, Ball Valve, Solenoid Valve |
| Tubing & Valve Material | PTFE |
| Compliance | Designed for integration into ISO/IEC 17025-compliant laboratory infrastructure |
| Application Scope | Local vacuum distribution within fume hood workspaces |