| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AIS-3200 |
| Detection Gases | PM2.5 (0–1000 µg/m³), CO₂ (400–10,000 ppm) |
| PM2.5 Principle | Laser Scattering |
| CO₂ Principle | Single-Source NDIR with Dual-Channel Detection |
| PM2.5 Accuracy | ±15% of reading or ±15 µg/m³ (−20°C to +75°C, referenced to TSI 8530) |
| CO₂ Accuracy | ±100 ppm or ±10% (400–10,000 ppm, −20°C to +75°C) |
| PM2.5 Response Time (T90) | ≤12 s |
| CO₂ Response Time (T90) | ≤25 s |
| Warm-up Time | <10 s |
| Operating Temperature | PM2.5: −40°C to +75°C |
| CO₂ | −40°C to +85°C |
| Storage Temperature | −40°C to +95°C |
| IP Rating | IP65 |
| Dimensions | Compact, automotive-grade form factor |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM1002 |
| Detection Principle | Laser Scattering (PM) / Metal Oxide Semiconductor (VOC) |
| PM Range | 0–5000 µg/m³ |
| VOC Range | 0–10 ppm |
| PM1.0/PM2.5 Accuracy | ±10 µg/m³ (0–100 µg/m³), ±10% reading (101–500 µg/m³) |
| PM10 Accuracy | ±25 µg/m³ (0–100 µg/m³), ±25% reading (101–500 µg/m³) |
| VOC Accuracy | ±15% (@0.3–1 ppm), ±25% (@30 ppm) |
| Warm-up Time | ≤180 s (VOC) |
| Data Refresh Rate | 1 Hz |
| Operating Temp. | −20–60 °C |
| Operating RH | 0–95% RH (non-condensing) |
| Storage Temp./RH | −40–80 °C / 0–95% RH |
| Supply Voltage | DC 5 V ±0.5 V (ripple <50 mV) |
| Interfaces | UART (3.3 V/5 V), I²C (3.3 V/5 V) |
| Dimensions | 38 × 35 × 12 mm |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM1008 |
| Price | USD 72 (FOB) |
| PM2.5 Range | 0–1000 µg/m³ |
| CO₂ Range | 400–5000 ppm |
| VOC Scale | 0–3 (Relative Index) |
| Update Interval | 1 s |
| Operating Temperature | −10 °C to +50 °C |
| Storage Temperature | −20 °C to +60 °C |
| Supply Voltage | DC 5 V ±0.1 V |
| Current Consumption | <300 mA |
| Communication Interfaces | UART-TTL, I²C |
| Dimensions | 80 × 50 × 13.6 mm (W×H×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM1008L |
| Price | USD 34.50 (FOB) |
| Detection Principle | Laser Scattering (PM), Metal-Oxide Semiconductor (VOC) |
| Particle Size Resolution | 0.3 µm |
| PM Range | 0–1000 µg/m³ |
| VOC Range | 0–10 ppm |
| PM Accuracy | ±10 µg/m³ (≤100 µg/m³), ±10% RDG (>100 µg/m³) for PM1.0/PM2.5 |
| VOC Accuracy | ±0.25 ppm (0–1 ppm), ±25% RDG (1–10 ppm) |
| Refresh Rate | 1 s |
| Operating Temp. | −10 to +50 °C |
| Humidity Range | 5–95% RH (non-condensing) |
| Storage | −20 to +60 °C, 0–95% RH |
| Supply Voltage | DC 5 V ±0.2 V (ripple <100 mV) |
| Operating Current | ≤100 mA |
| Standby Current | ≤200 µA (SET pin low) |
| Interface | UART TTL @ 3.3 V logic level |
| Dimensions | 48 × 40 × 12 mm (W×H×D) |
| Shielding | Full-metal EMI shielding |
| Compliance | RoHS, CE-EMC, FCC Part 15 Subpart B |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM1009 |
| Detection Principles | Laser Light Scattering (PM), Metal Oxide Semiconductor (VOC, NOₓ, CO, HC) |
| PM Range | 0–5000 µg/m³ |
| VOC Range | 0–10 ppm |
| NO₂ Range | 0–10 ppm |
| PM Accuracy | ±10 µg/m³ (0–100 µg/m³), ±10% reading (101–500 µg/m³) for PM₁.₀/PM₂.₅ |
| Data Update Interval | 1 s |
| Power-On Stabilization Time | ≤180 s (VOC channel) |
| Operating Temp. | −10 to +60 °C |
| Operating RH | 5–95% RH (non-condensing) |
| Storage Temp./RH | −30 to +70 °C / 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.1 V, ripple <50 mV |
| Interfaces | UART (3.3 V / 5 V logic), I²C (5 V logic) |
| Dimensions | 50 × 38 × 21 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM1009CN |
| Detection Principles | Optical Scattering (PM2.5), Electrochemical/Semiconductor (CO), NTC Thermistor (Temperature) |
| Measurement Ranges | PM2.5: 0–5000 µg/m³ |
| CO | 0–1000 ppm |
| Temperature | −10–60 °C |
| Accuracy | PM2.5: ±20% of reading or ±200 µg/m³ |
| CO | ±30% of reading or ±40 ppm |
| Temperature | ±1 °C |
| Alarm Thresholds | PM2.5 ≥ 2000 µg/m³ |
| Data Update Interval | 1 s |
| Operating Conditions | −10–60 °C, 0–95% RH (non-condensing) |
| Storage Conditions | −30–70 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 12 V ± 0.5 V, Ripple < 100 mV |
| Average Current Consumption | < 100 mA |
| Output Interface | Digital Switch Output (configurable for CAN bus upon request) |
| Dimensions | 100 × 60 × 24.5 mm (W × H × D) |
| Minimum Detectable Particle Size | 0.3 µm |
| Sampling Method | Constant-Flow Aspiration |
| Calibration | Auto-compensated CO baseline correction |
| Compliance | RoHS-compliant design |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | AM1012 |
| Price | USD 72 (FOB) |
| Detection Parameters | PM2.5 (0–1000 µg/m³), CO₂ (400–2000 ppm), Temperature (−10°C to 50°C), Relative Humidity |
| Refresh Rate | 1 s |
| Power Supply | DC 12 V ±1 V |
| Current Consumption | <500 mA |
| Communication Interface | RS485 |
| Dimensions | 81.3 × 74.3 × 25.9 mm |
| EMC Performance | Built-in voltage regulation, ESD protection (>±8 kV contact discharge), conducted/radiated immunity compliant with IEC 61000-4 series |
| Operating Humidity Range | 0–95% RH non-condensing |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM1050 |
| Detection Range | ≥0.3 µm, 0–9,999,999 pcs/L |
| Output Channels | 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 µm |
| Counting Efficiency | 50% @ 0.3 µm |
| Operating Temperature | −30°C to +70°C |
| Storage Temperature | −40°C to +85°C |
| Supply Voltage | DC 5 V ±0.1 V or DC 9–36 V |
| Current Draw | <500 mA @ 5 V, <300 mA @ 9 V, <100 mA @ 36 V |
| Communication Interface | RS-485 / 4–20 mA (customizable) |
| Dimensions | 100 × 115 × 40 mm (W × D × H) |
| Compliance | JJF 1190–2008 Calibration Specification for Airborne Particle Counters |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM4203H |
| Pricing | Available Upon Request |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Target Gases | R32, R454A, R454B, R454C, R290 (A2L & A3 refrigerants) |
| Measurement Range | 0–100% LFL |
| Accuracy | ±2.5% LFL (0–25% LFL), ±10% of reading (25–100% LFL) |
| Resolution | 0.1% LFL |
| Response Time (T90) | ≤30 s |
| Output Interfaces | RS485 Modbus RTU, Relay (dry contact) |
| Enclosure Rating | IP54 |
| Operating Temperature | −30 to +70 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −40 to +85 °C, 0–95% RH (non-condensing) |
| Power Supply | AC 18–36 V (24 V nominal, 55±8 Hz) or DC 12–36 V (24 V nominal) |
| Service Life | >15 years |
| Dimensions | 103.2 × 80 × 30.5 mm (customization available) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM4205 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Detection Range | 0–50% LFL |
| Resolution | 1% LFL |
| Accuracy | ±3.75% LFL |
| Data Refresh Rate | ≤1 s |
| Response Time (T90) | <30 s |
| Warm-up Time (T25) | ≤7 s |
| Output Options | UART / 0.8–4 V (default) / PWM (customizable) |
| Operating Temperature | −30 to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −30 to +70 °C / 0–95% RH (non-condensing) |
| Supply Voltage | 5 ± 0.1 V DC (ripple <50 mV) |
| Average Current Consumption | ≤150 mA |
| Peak Current | <300 mA |
| IP Rating | IP54 |
| Heating Function | Integrated self-heating element for anti-condensation and frost prevention |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM4207 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–50% LFL |
| Accuracy | ±5% LFL |
| Response Time (T50) | ≤10 s |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +85 °C |
| Humidity Range | 0–100% RH |
| Supply Voltage | DC 9–36 V |
| Current Consumption | <250 mA |
| Communication Interface | CAN bus |
| Protection Rating | IP67 (detector housing), IP65 (sensor head) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | AM4209 |
| Pricing | Available Upon Request |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Maximum Sensitivity | 1 g/year (static), 3 g/year (dynamic) |
| Refrigerant Compatibility | HFOs (e.g., 1234yf, 1234ze), A2L-class refrigerants, and common blends (R-134a, R-410A, R-32) |
| Alarm Output | Visual (red LED + LCD bar graph + numeric display), Audible (buzzer), Tactile (vibration) |
| Response Time | <1 second |
| Power Source | Rechargeable Lithium-ion Battery / 10-hour runtime |
| Display | Backlit LCD with real-time concentration readout |
| Operating Environment | 0°C to 40°C (32°F to 104°F), <75% RH (non-condensing) |
| Ingress Protection | IP54 |
| Key Features | High measurement accuracy, long-term stability, rapid response, poison-resistant sensor architecture, electromagnetic interference (EMI) robustness |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM6108B |
| Instrument Type | Online Monitoring Controller |
| CO₂ Detection Principle | Non-Dispersive Infrared (NDIR) |
| PM₂.₅ Detection Principle | Optical Scattering |
| Formaldehyde Detection Principle | Electrochemical Sensing |
| Measurement Range | PM₂.₅: 0–1000 µg/m³ |
| CO₂ | 0–5000 ppm |
| Formaldehyde | 0–0.5 mg/m³ (up to 1 mg/m³) |
| Temperature | −10°C to +50°C |
| Relative Humidity | 0–95% RH |
| Data Update Interval | 1 s |
| Operating Voltage | DC 12 V |
| Current Consumption | <140 mA |
| Communication Interface | RS485 |
| Dimensions | 86 mm × 86 mm × 24.9 mm (W×H×D) |
| Mounting Options | Embedded or Wall-Mounted |
| Control Output | Three-Speed Fan Regulation, Supply/Exhaust Switching, Mode Selection (Smart/Manual/Silent/Time-Scheduled) |
| Optional Feature | Filter Replacement Alert |
| Sensor Configuration | Modular — PM₂.₅, CO₂, Formaldehyde, Temperature & Humidity sensors selectable per application requirement |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | APMS-3302 |
| Price | USD 78 (FOB) |
| Detection Principle | Laser Scattering (Mie Theory) |
| PM2.5 Range | 0–1000 µg/m³ |
| Accuracy | ±15% of reading or ±15 µg/m³ (at –20°C to +60°C, referenced to TSI AM510/8530) |
| Operating Temperature | –30°C to +70°C |
| Storage Temperature | –40°C to +85°C |
| Ingress Protection | IP5K4 |
| Supply Voltage | DC 9–16 V |
| Communication Interface | LIN 2.2A |
| Output Options | PM2.5 mass concentration (µg/m³) |
| Response Time | <3 s (dynamic airflow, vehicle motion conditions) |
| Laser Source Lifetime | >50,000 hours |
| Optical Chamber | Self-cleaning lens structure with hydrophobic coating |
| Calibration Traceability | NIST-traceable reference aerosols (ISO 2591-1, ISO 12103-1 A2 test dust) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | APMS-5000 |
| Price | Upon Request |
| Detection Principle | Laser Light Scattering |
| Measurement Range | 0–1000 µg/m³ |
| Accuracy | ±10% (100–1000 µg/m³) and ≤±10 µg/m³ (0–100 µg/m³) at –20–50°C |
| Extended Accuracy | ±20% (100–1000 µg/m³) and ≤±20 µg/m³ (0–100 µg/m³) at –40––20°C & 50–70°C |
| Particle Size Range | 0.3–2.5–10 µm |
| Operating Environment | –40 to +85°C, 0–95% RH (non-condensing) |
| Communication Interface | LIN Bus |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AQM-1020 |
| Pricing | Available Upon Request |
| Sensing Principle | Metal Oxide Semiconductor (MOX) |
| Target Gases | CO, NO₂, NH₃ (optional) |
| Maximum Gas Flow Rate | ≤10 m/s |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +120 °C |
| Relative Humidity Range | 0–99% RH (non-condensing) |
| Supply Voltage | 9–16.2 V DC (nominal 12 V DC) |
| Operating Current | ≤40 mA |
| Standby Current | ≤100 µA |
| Ingress Protection | IP6K7 |
| Communication Interface | LIN bus / PWM output |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ARS-744 |
| Detection Range | 400–40,000 ppm CO₂ (R744) |
| Accuracy | ≤750 ppm: ±75 ppm |
| 750–5,000 ppm | ±10% of reading |
| 5,000–40,000 ppm | ±20% of reading |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +95 °C |
| Supply Voltage | DC 9–16 V |
| Current Consumption | ≤100 mA |
| Output Interface | LIN bus |
| Zero Drift | Low, long-term stability optimized |
| Measurement Principle | Dual-source NDIR (Non-Dispersive Infrared) with temperature & pressure compensation |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ATRS-1010-H2 |
| Detection Principle | Thermal Conductivity (TC) |
| Target Gas | H₂ |
| Range | 0–4 %vol |
| Resolution | 0.01 %vol |
| Accuracy | ±(0.1 %vol + 10% of reading) |
| Response Time (T90) | ≤20 s |
| Data Refresh Rate | ≤1 s |
| Output Interface | TTL UART |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–99 %RH (non-condensing) |
| Storage Conditions | −40 °C to +95 °C, 0–99 %RH (non-condensing) |
| Operating Pressure | 80–120 kPa |
| Ingress Protection | IP54 |
| Supply Voltage | 4.5–5.5 VDC (nominal +5 VDC) |
| Average Current Consumption | ≤100 mA |
| Design Lifetime | >15 years |
| Brand | Cubic |
|---|---|
| Model | ATRS-1010-P |
| Detection Principle | MEMS-based Absolute Pressure Sensing |
| Measurement Range | 50–160 kPa |
| Full-Scale Peak Load | 600 kPa |
| Burst Pressure | 800 kPa |
| Resolution | 0.1 kPa |
| Accuracy | ≤ ±1.15 kPa (0–85 °C), ≤ ±1.725 kPa (−40–0 °C & 85–125 °C) |
| Response Time | <1 s (pressure anomaly detection & wake-up signal to BMS), <50 ms (first CAN frame after BMS wake-up) |
| Output Interface | CAN 2.0B, 500 kbps |
| Sampling Interval | 10 ms (normal mode), 1 s (low-power mode) |
| Power Supply | 9–16 VDC (nominal 12 VDC) |
| Operating Current | 20 mA (normal), <0.2 mA (low-power), <100 µA (sleep) |
| Operating Temperature | −40 to +105 °C |
| Storage Temperature | −40 to +125 °C |
| Humidity Range | 0–99% RH (non-condensing) |
| Enclosure Material | UL94 V-0 flame-retardant polymer |
| Ingress Protection | IP40 |
| Design Lifetime | >15 years |
| Key | Brand: Cubic |
|---|---|
| Model | ATRS-1021 |
| Gas Detection Principle | CO₂ – NDIR |
| Measurement Ranges | CO₂: 0–10,000 ppm |
| CO/HC/H₂ | 1–1,000 ppm |
| PM | 0–5 mg/m³ |
| Pressure | 80–120 kPa |
| Temp | −40–125 °C |
| Accuracy | CO₂: ±(50 ppm + 5% of reading) |
| CO/HC/H₂ | ±40 ppm or ±30% of reading (whichever is greater) |
| PM | ≤100 µg/m³ → ±15 µg/m³, >100 µg/m³ → ±15% of reading |
| Pressure | ±0.1 kPa |
| Temp | ±2 °C |
| Resolution | CO₂/CO/HC/H₂: 1 ppm |
| PM | 1 µg/m³ |
| Pressure | 0.1 kPa |
| Temp | 0.1 °C |
| Response Time (T90) | CO₂ <15 s |
| Data Refresh Rate | ≤1 s |
| Output Interface | CAN (default), LIN, UART |
| Operating Temp | −40–85 °C |
| Humidity | 0–99% RH (non-condensing) |
| Power Supply | 9–16 VDC (nominal 12 VDC) |
| Avg. Current | ≤150 mA (normal), ≤50 mA (low-power mode), <100 µA (sleep) |
| Enclosure Rating | IP65 |
| Expected Service Life | ≥15 years (CO₂ & MOX sensors) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ATRS-1031 |
| Detection Principle | Infrared Light Scattering (PM), NTC Thermistor (Temperature) |
| Measurable Parameters | PM₂.₅/PM₁₀ (1–10,000 µg/m³), Temperature (−40 to +85 °C) |
| Resolution | 1 µg/m³ (PM), 0.1 °C (T) |
| Accuracy | ±15 µg/m³ (≤100 µg/m³), ±15% of reading (>100 µg/m³) |
| Response Time | ≤1 s |
| Output Interface | CAN 2.0B |
| Protection Rating | IP40 |
| Operating Voltage | 6–16 VDC (nominal 12 VDC) |
| Current Consumption | ≤30 mA (active), ≤500 µA (low-power mode), ≤50 µA (deep sleep) |
| Design Lifetime | 10 years |
| Operating Environment | −40 to +85 °C, 0–99% RH (non-condensing) |
| Storage Range | −40 to +95 °C, 0–99% RH (non-condensing) |
| Pressure Range | 60–120 kPa |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CB-HCHO-V4 |
| Detection Principle | Electrochemical |
| HCHO Range | 0–1 ppm |
| VOC/TVOC Range | 0–10 ppm (ethanol-equivalent) |
| HCHO Accuracy | ±30 ppb or ±10% (whichever is greater) @ 25±2°C, 50±10% RH |
| Resolution | HCHO: 1 ppb |
| VOC/TVOC | 0.01 ppm |
| Response Time (T90) | 50 s @ 25±2°C, 50±10% RH |
| Warm-up Time | 100 s |
| Operating Temp | −10 to +50°C |
| Operating Humidity | 15–95% RH (non-condensing) |
| Storage Conditions | −20 to +50°C, 15–95% RH (non-condensing) |
| Supply Voltage | DC 3.5–5.5 V |
| Current Consumption | <15 mA |
| Communication Interfaces | UART-TTL (3.3 V), I²C (reserved), PWM (reserved) |
| Dimensions | 23 × 32 × 8 mm (W×H×D) |
| Lifetime | Up to 6 years |
| Cross-sensitivity to Ethanol | <1% |
| Long-term Stability | Engineered for industrial-grade drift control |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CB-HCHO-V4S |
| Price | Upon Request |
| Detection Principle | Electrochemical |
| Measurement Range | 0–1 ppm HCHO |
| Accuracy | ±25 ppb or ±25% (whichever is greater) @ 25±2°C, 50±10% RH |
| Resolution | 1 ppb HCHO |
| Response Time (T90) | 50 s @ 25±2°C, 50±10% RH |
| Warm-up Time | 100 s |
| Operating Temperature | −10 to +50 °C |
| Operating Humidity | 15–95% RH (non-condensing) |
| Storage Conditions | −20 to +60 °C, 15–95% RH (non-condensing) |
| Supply Voltage | DC 3.5–5.5 V |
| Current Consumption | <15 mA |
| Communication Interfaces | UART-TTL (3.3 V), PWM, I²C (pinout预留) |
| Dimensions | 23 × 32 × 8 mm (W × H × D) |
| Service Life | 6 years in ambient air |
| Integrated Sensors | Digital temperature & humidity sensor |
| Compensation | Full-range temperature & humidity compensation |
| Electrolyte Encapsulation | Proprietary hermetic sealing technology |
| Interference Resistance | Engineered for low cross-sensitivity to CO, NO₂, VOCs, and ethanol |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | CB-HCHO-V5 |
| Detection Principle | Electrochemical |
| Measurement Range | 0–1 ppm |
| Resolution | 1 ppb |
| Response Time | <90 s |
| Operating Temperature | −20 °C to +60 °C |
| Accuracy | ±0.02 ppm or ±20% (whichever is greater) at 25 ± 2 °C, 50 ± 10% RH |
| Lifetime | >6 years |
| Output Interface | UART TTL |
| Dimensions | 43 × 8.8 × 24 mm |
| Integrated Temperature & Humidity Compensation | Yes |
| Cross-sensitivity to Ethanol | Low |
| Power Consumption | Ultra-low (battery-compatible) |
| Brand | Cubic |
|---|---|
| Model | CM01 |
| Type | Portable CO₂ Monitor |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Sensing |
| Range | 400–5000 ppm |
| Accuracy | ±(50 ppm + 5% of reading) |
| Operating Temperature | −10 °C to 50 °C, 0–95% RH (non-condensing) |
| Storage Temperature | −20 °C to 60 °C, 0–95% RH (non-condensing) |
| Power Supply | DC 5 V (USB-powered) |
| Display | Digital LCD |
| Dimensions | 101.9 × 26.4 × 16 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CM1106SD |
| Price | USD 42 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–5000 ppm CO₂ (standard configuration) |
| Accuracy | ±(50 ppm + 3% of reading) @ 25°C, 1 atm |
| Response Time (T90) | < 90 s |
| Operating Temperature | –10°C to +50°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Supply | 5.0 VDC ±5% |
| Average Current Consumption | < 25 mA |
| Output Interface | Analog (0.4–2.0 V DC proportional to CO₂ concentration) + UART (TTL level) |
| Warm-up Time | < 60 s |
| Dimensions | 33 × 22 × 18 mm |
| Weight | ~12 g |
| Lifetime | > 15 years (typical sensor core) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CM1106SL-N |
| Detection Principle | NDIR (Non-Dispersive Infrared) |
| Measurement Range | 0–5000 ppm CO₂ |
| Accuracy | ±(50 ppm + 5% of reading) at 25°C ± 2°C |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −30°C to +70°C |
| Supply Voltage | DC 5 V ± 0.1 V (ripple < 50 mV) |
| Average Current Consumption | 12 µA @ 5-min measurement interval |
| Output Interface | UART TTL (3.3 V / 5 V compatible) |
| Dimensions (L×W×H) | 33 × 19.7 × 9.4 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CM1107 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–5000 ppm (customizable up to 12,000 ppm) |
| Warm-up Time | ≤30 s |
| Data Update Rate | 1 Hz |
| Accuracy | ±(30 ppm + 3% of reading) at 25°C±2°C, 50%±10% RH |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −30°C to +70°C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.1 V |
| Average Current Consumption | <70 mA |
| Output Interfaces | UART TTL (3.3 V / 5 V), I²C, PWM |
| Dimensions (L×W×H) | 33 mm × 21.7 mm × 10 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CM1109 |
| Price | USD 68.50 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 400–5000 ppm (extendable to 10,000 ppm) |
| Warm-up Time | ≤30 s |
| Data Update Rate | 1 Hz |
| Accuracy | ±(50 ppm + 5% of reading) for residential use |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −30°C to +70°C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.1 V |
| Average Current Consumption | <45 mA |
| Output Interfaces | UART TTL (3.3 V / 5 V logic), I²C, PWM |
| Dimensions (L×W×H) | 33 × 20.3 × 11.4 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | CM2201 |
| Price | USD 700 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–150 mmHg |
| Resolution | 0.1 mmHg |
| Accuracy | ±2 mmHg (0–40 mmHg), ±5% of reading (41–70 mmHg), ±8% (71–100 mmHg), ±10% (100–150 mmHg) |
| Respiratory Rate Range | 0–150 BPM |
| Respiratory Rate Accuracy | ±1 BPM |
| Short-Term Drift | ≤0.8 mmHg (4 h) |
| Long-Term Drift | Maintains Specified Accuracy over 120 h |
| Supply Voltage | 5.00 V ±5% |
| Avg. Current Draw | <120 mA |
| Peak Current | <250 mA |
| Warm-up Time to Display | ≤15 s |
| Time to Full-Spec Accuracy | ≤2 min (at 25°C) |
| Barometric Pressure Compensation | 400–850 mmHg |
| Operating Temp. | 0–45°C, 10–90% RH (non-condensing) |
| Storage Temp. | −40–70°C, <90% RH (non-condensing) |
| Interface | RS232, 19200-N-8-1 |
| Dimensions | 52 × 23 × 36 mm |