Gas Detector
Filter
Showing 481–510 of 1055 results
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000GHG |
| Instrument Type | Online Analyzer |
| Detection Principle | Micro-flow NDIR & Dual-beam NDIR (CO₂/CH₄/N₂O/CO), Electrochemical (O₂) |
| Measured Gases | CO₂, CH₄, N₂O, CO, O₂ |
| CH₄ Range | 0–1000 ppm, Resolution: 1 ppm |
| Repeatability | ≤ ±1% F.S. |
| Accuracy | ±1% F.S. (micro-flow NDIR), ±2% F.S. (dual-beam NDIR & ECD) |
| Response Time (T90) | < 25 s |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Power Supply | 100–240 VAC, max 300 W (heating), stable 100 W |
| Output | RS-485/RS-232, 4–20 mA |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measured Gases | CO, CO₂, O₂, SO₂, NO, Flue Gas Temperature |
| Measurement Principle | NDIR (CO, CO₂), Electrochemical (O₂, SO₂, NO), K-type Thermocouple (Temperature) |
| Range | CO/NO: 0–2000 ppm |
| SO₂ | 0–5000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | ±2% F.S. (all gases), ±3°C (temperature) |
| Repeatability | ≤2% |
| Response Time (T90) | <20 s (NDIR) |
| Resolution | SO₂/NO/CO: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Optimal Flow Rate | 0.7–1.2 L/min |
| Power | Rechargeable Li-ion battery, 12.6 V external charger |
| Communication | RS485 / RS232 |
| Features | Integrated temperature-compensated sampling probe, auto-diagnostic function, built-in imported sampling pump, data logging with query/delete capability |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Range | CO/NO: 0–2000 ppm |
| SO₂ | 0–5000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | ±2% F.S. for CO/CO₂/SO₂/NO/O₂ |
| Repeatability | ≤2% |
| Response Time (T90) | <20 s (NDIR channels) |
| Detection Parameters | SO₂, NO, CO, CO₂, O₂, flue gas temperature |
| Measurement Principles | NDIR for CO/CO₂ |
| Resolution | 1 ppm for SO₂/NO/CO |
| Optimal Sampling Flow Rate | 0.7–1.2 L/min |
| Power Supply | Internal rechargeable Li-ion battery |
| Communication Interfaces | RS485, RS232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000Plus |
| Measurement Principle | Microflow NDIR (SO₂/NO/CO), NDIR (CO₂), Electrochemical Detection (O₂) |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Range | SO₂/NO: 0–200 ppm |
| CO | 500–5000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | ±2% FS |
| Repeatability | <2% |
| Response Time (T90) | <25 s (NDIR) |
| Resolution | SO₂/NO: 1 ppm |
| CO | 1 ppm |
| CO₂/O₂ | 0.01% |
| Zero Drift Stability | ±2% over 7 days |
| Flow Rate | 0.7–1.2 L/min |
| Output | RS-485 / RS-232 / 4–20 mA |
| Power | 100–240 VAC, 150 W |
| Auto-Zero Function | Integrated air pump with programmable zero calibration |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Gasboard-3000Plus |
| Instrument Type | Online Fixed-Mount Analyzer |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Measurement Range | SO₂/NO: (0–200) ppm |
| CO | (500–5000) ppm |
| CO₂/O₂ | (0–25) % vol |
| Repeatability | < 2% |
| Resolution | SO₂/NO: 1 ppm |
| CO | 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Response Time (T₉₀) | < 25 s (NDIR channels) |
| Linearity Error | ≤ ±2% F.S. |
| Sample Flow Rate | (0.7–1.2) L/min |
| Output Interfaces | RS-485 / RS-232 serial, (4–20) mA analog |
| Power Supply | 100–240 VAC, 150 W |
| Detection Principle | Micro-Flow NDIR (SO₂, NO, CO), Broadband NDIR (CO₂), Electrochemical Detection (O₂) |
| Zero Calibration | Integrated air pump with automatic ambient-air zeroing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000UV |
| Measurement Principle | UV-DOAS (SO₂, NO, NO₂) |
| Measured Gases | SO₂, NO, NO₂, O₂ |
| Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T₉₀) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Liquid-free, particulate filtration <1 µm |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 200 W |
| Communication | Dual RS-232/RS-485, Modbus RTU or customizable protocol |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000UV |
| Measurement Principle | UV-DOAS (SO₂/NO/NO₂), Electrochemical (O₂) |
| Measurands | SO₂, NO, NO₂, O₂ |
| Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T90) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Condensate-free, particulate filtration <1 µm |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Communication | RS-232/RS-485 (Modbus RTU or customizable) |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 200 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000UV |
| Detection Principle | UV Differential Optical Absorption Spectroscopy (UV-DOAS) |
| Instrument Type | Online Fixed-Mount Analyzer |
| Measurement Channels | Single Channel |
| Measuring Range | NO: 0–4000 ppm |
| NO₂ | 0–400 ppm |
| Response Time | T₉₀ ≤ 30 s |
| Accuracy | ±2% FS |
| Operating Temperature | 5–40 °C |
| Ambient Pressure | 86–106 kPa |
| Relative Humidity | ≤85% RH |
| Output Signals | RS-232 / RS-485 serial interface |
| Power Supply | 220 V ± 10%, 50 Hz ± 1 Hz |
| Display | LCD with local parameter readout |
| Zero Calibration | Integrated zero-air pump for automatic air-based zeroing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3001 |
| Principle | Micro-flow NDIR + UV-DOAS + TDLAS Hybrid Optical Detection |
| Type | Portable |
| Response Time | <60 s |
| Repeatability | ≤±2% F.S. for SO₂, H₂S, CO |
| Measurement Ranges | SO₂: 0–100 ppm |
| H₂S | 0–100 ppm |
| CO | 0–1000 ppm |
| Resolution | SO₂/H₂S: 0.1 ppm |
| CO | 1 ppm |
| Zero/End Drift | ±2% F.S./4 h |
| Warm-up Time | 800 s |
| Operating Temperature | 5–40 °C |
| Power Supply | Rechargeable Li-ion battery (≥4 h runtime) |
| Communication | RS-232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3001 |
| Configuration | Online Multicomponent Gas Analyzer |
| Measurement Principles | NDIR (CO₂), TDLAS (CH₄, N₂O) |
| CO₂ Range | 0–1000 ppm |
| CH₄ Range | 0–50 ppm |
| N₂O Range | 0–20 ppm |
| Accuracy | ±1% of full scale for all gases |
| Repeatability | <1% RSD for CO₂, CH₄, and N₂O |
| Power Supply | Internal rechargeable battery ≥8 h continuous operation |
| Data Storage | Onboard memory supporting ≥3 months of timestamped concentration data |
| Communication Interfaces | RS-232, RS-485, USB, optional Ethernet/Wi-Fi module |
| Enclosure Rating | IP65 |
| Operating Temperature | –10 °C to +50 °C |
| Dimensions | 280 × 190 × 120 mm |
| Weight | ≤3.2 kg |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3003 |
| Principle | Micro-flow NDIR (Non-Dispersive Infrared) Absorption |
| Type | Portable |
| Response Time | <60 s |
| Repeatability | ±2% F.S. |
| Operating Temperature | 5–40 °C |
| Power Supply | Rechargeable Li-ion Battery (≥4 h runtime) |
| Communication Interface | RS-232 |
| Preheat Time | 800 s |
| Zero/End-point Drift | ±2% F.S. / 4 h |
| Resolution | 0.01% for SF₆ purity (when configured), moisture detection range: 1–1000 ppmv (H₂O in SF₆) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3006UV |
| Measurement Principle | UV DOAS |
| Measured Gases | SO₂, NO, NO₂, O₂ |
| Accuracy | ≤±1% F.S. |
| Repeatability | ≤1% |
| Response Time | T₉₀ ≤30 s at 1 L/min |
| Stability | ≤±1.5% F.S./24 h |
| Linear Error | ≤±1% F.S. |
| Sample Flow Rate | 0.7–1.2 L/min |
| Display | 7-inch color TFT touchscreen (800×480) |
| Dimensions (W×H×D) | 438×173×350 mm |
| Power Supply | 100–240 VAC, 100 W |
| Communication | Dual RS232/RS485, 4–20 mA analog output |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3050-D |
| Measurement Principle | Ceramic Zirconia Electrolyte (O₂), Derived H₂O Calculation via O₂/H₂O Correlation |
| H₂O Range | 0–40 %v/v |
| O₂ Range | 0.1–25 %v/v |
| Accuracy | ±2 %F.S. (H₂O & O₂) |
| Repeatability | ±2 % |
| Sample Temp. Limit | ≤ 180 °C |
| Output | Dual 4–20 mA, RS485 (standard), RS232 (optional), 3 x Relay Outputs |
| Power | 24 V DC, 50 W |
| Installation | Wall-mounted probe + DIN-rail instrument housing |
| Enclosure | Non-explosion-proof |
| Operating Ambient | −10 to +50 °C, <90 %RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3055 |
| Instrument Type | In-Situ Flue Gas Oxygen Analyzer |
| Measurement Range | 0–25% O₂ |
| Resolution | 0.1% O₂ |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Response Time (T90) | <15 s |
| Stability | ±2% F.S. / 7 days |
| Operating Temperature (Flue Gas) | 0–700 °C |
| Probe Length Options | 500 / 1000 / 1500 mm (customizable) |
| Sampling Method | Flow-guided direct insertion |
| Installation | DN40 flange mount |
| Enclosure Rating | IP65 |
| Display | 128×160 color LCD |
| Output Signals | RS-485 & 4–20 mA |
| Relay Outputs | 2 channels |
| Power Supply | DC 24 V ±10%, 2 A |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3055 |
| Instrument Type | In-situ Flue Gas Oxygen Analyzer |
| Repeatability | ≤±1% FS |
| Response Time | T90 < 15 s |
| Stability | ±2% FS / 7 days |
| Measured Gas | O₂ |
| Measurement Range | 0–25% vol |
| Resolution | 0.1% vol |
| Accuracy | ±2% FS |
| Sampling Method | Direct-insertion, flow-guided probe |
| Operating Temperature | 0–700 °C |
| Enclosure Rating | IP65 |
| Output Signals | RS-485 & 4–20 mA |
| Power Supply | DC 24 V ±10%, 2 A |
| Probe Length Options | 500 / 1000 / 1500 mm (customizable) |
| Display | 128×160 color LCD |
| Alarm Outputs | 2 relay channels |
| Calibration | Field-calibratable with ambient air or certified O₂ standard gas |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Measurement Principle | NDIR (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm), TCD (H₂), ECD (O₂) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)%, O₂: (0–25)%, C₂H₂/C₂H₄/CnHm: (0–10)% (optional) |
| Accuracy | ±1% FS (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm), ±2% FS (O₂/H₂) |
| Repeatability | ≤1% |
| Response Time (T90) | <15 s (NDIR) |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Resolution | 0.01% |
| Output | RS-485/RS-232, 4–20 mA |
| Power Supply | 100–240 VAC, 100 W |
| Display | LCD |
| Thermal Value Units | kcal/m³ & MJ/m³ (switchable) |
| Auto-Zero | Built-in air pump |
| Diagnostics | Real-time sensor health monitoring |
| Sample Requirements | Dust-free, moisture-free, oil-free gas |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Detection Principle | Non-Dispersive Infrared (NDIR), Electrochemical (ECD), Thermal Conductivity (TCD) |
| Configuration | Online Fixed-Mount Analyzer |
| Measured Gases | CO, CO₂, CH₄, H₂, O₂, C₂H₂, C₂H₄, CnHm (total non-methane hydrocarbons), Calorific Value |
| Range | CO/CO₂/CH₄/H₂: (0–100) % vol |
| O₂ | (0–25) % vol |
| C₂H₂/C₂H₄/CnHm | (0–10) % vol (optional) |
| Linearity Error | ±1 % FS (NDIR channels) |
| Resolution | 0.01 % vol |
| Repeatability | ≤1 % |
| Response Time (T90) | <15 s (NDIR) |
| Sample Flow Rate | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Power Supply | 100–240 VAC, 100 W |
| Output | RS-485 / RS-232, (4–20) mA |
| Display | LCD with local interface |
| Calibration | Built-in zero-air pump for automatic air zeroing |
| Thermal Value Units | kcal/m³ and MJ/m³ (switchable) |
| Materials of Construction | 316L stainless steel, PTFE-wetted components |
| Compliance | Designed for continuous emission monitoring (CEM) and process control in industrial environments per ISO 14001-aligned operational practices |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100P |
| Principle | NDIR (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm), TCD (H₂), ECD (O₂) |
| Type | Portable |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| C₂H₂/C₂H₄/CnHm | (0–10)% (optional) |
| Resolution | 0.01% |
| Repeatability | ≤1% FS |
| Response Time (T90) | <15 s (NDIR) |
| Linear Error | ±1% FS (NDIR gases), ±2% FS (O₂/H₂) |
| Sample Flow Rate | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Dimensions (L×W×H) | 412×152×294 mm |
| Weight | 9 kg |
| Power | Rechargeable Li-ion battery, external 12.6 V charger |
| Communication | RS-232 |
| Thermal Value Units | kcal/m³ & MJ/m³ (switchable) |
| Self-diagnostic capability | Yes |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3201Plus |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±0.2% FS (O₂, CO₂) |
| Response Time | T₉₀ < 30 s (O₂, SO₂, CO₂), T₉₀ < 40 s (CO, NO), T₆₀ < 30 s (SO₂) |
| Measured Gases | O₂, CO, NO, SO₂, CO₂ |
| Gas Detection Principle | Electrochemical (O₂, CO, NO, SO₂), NDIR (CO₂) |
| Operating Temperature | –5 °C to +45 °C |
| Display | 5.5-inch HD touchscreen (720 × 1280 px) |
| Battery | Rechargeable Li-ion, 3.7 V / 6400 mAh |
| Data Storage | Internal memory for 2000 measurement sets |
| Connectivity | Bluetooth 5.0 for mobile app and wireless printer |
| Compliance | Designed to support EPA Method 6C, ISO 12039, EN 15267-3, and GLP-compliant data logging with timestamped audit trail |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3400P |
| Measurement Principle | NDIR for CO/CO₂ |
| Measured Parameters | CO (0–5000 ppm), CO₂ (0–25 % vol), O₂ (0–21 % vol), flue gas temperature (0–1200 °C) |
| Accuracy | CO/CO₂: ±1% FS |
| O₂ | ±2% FS |
| temperature | ±3 °C or ±1% of reading |
| Repeatability | ≤1% |
| Response Time (T90) | ≤15 s (NDIR) |
| Resolution | O₂: 0.01% vol |
| CO | 1 ppm |
| CO₂ | 0.01% vol |
| temperature | 0.1 °C |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 5–85% RH |
| Battery Life | >10 h (rechargeable Li-ion) |
| Communication | RS-232 / RS-485 |
| Expandable Sensors | SO₂, NO, NO₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 |
| Instrument Type | Online |
| Detection Principle | NDIR (CO, CO₂, CH₄, C₃H₈), Electrochemical (O₂, H₂S) |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Measurement Range | CO/CO₂/CH₄/C₃H₈: (0–100)% vol |
| O₂ | (0–25)% vol |
| H₂S | (0–9999) ppm |
| Repeatability | ≤2% |
| Accuracy | ±1% FS (NDIR gases), ±2% FS (O₂/H₂S) |
| Response Time (T90) | <15 s (NDIR) |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Display | LCD |
| Output | RS-485/RS-232, 4–20 mA, Ethernet |
| Power | AC 220 V, 50 Hz |
| Explosion Protection | Ex d II CT6 / Ex tb IIIC T80°C Db |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 (Explosion-Proof) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) & Electrochemical Detection (ECD) |
| Configuration | Online Fixed-Mount Analyzer |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Range | CO/CO₂/CH₄/C₃H₈: 0–100% vol |
| O₂ | 0–25% vol |
| H₂S | 0–9999 ppm |
| Resolution | 0.01% vol (down to 1 ppm for low-range gases) |
| Response Time | T₉₀ < 15 s (NDIR channels) |
| Repeatability | ≤2% FS |
| Accuracy | ±1% FS (CO, CO₂, CH₄, C₃H₈) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Output Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Display | Integrated LCD |
| Explosion Protection | Ex d IIC T6 Gb / Ex tb IIIC T80°C Db |
| Certifications | Compliant with GB 3836.1–2010, GB 3836.2–2010, GB 3836.8–2014 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 (Explosion-Proof) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) & Electrochemical Detection (ECD) |
| Configuration | Online Fixed-Mount Analyzer |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Range | CO/CO₂/CH₄/C₃H₈: 0–100% vol |
| O₂ | 0–25% vol |
| H₂S | 0–9999 ppm |
| Response Time (T₉₀) | <15 s (NDIR channels) |
| Accuracy | ±1% FS (NDIR gases), ±2% FS (O₂, H₂S) |
| Repeatability | ≤2% |
| Resolution | 0.01% (low-range equivalent to 1 ppm) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Electrical Interface | RS-485 / RS-232 / 4–20 mA / Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD |
| Explosion Protection | Ex d IIC T6 Gb / Ex tb IIIC T80°C Db |
| Certifications | Compliant with GB 3836.1–2010, GB 3836.2–2010, GB 3836.8–2014 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 |
| Measurement Principle | NDIR & Electrochemical Detection |
| Configuration | Online Fixed Installation |
| Response Time | T90 < 15 s (NDIR) |
| Repeatability | ≤2% FS |
| Accuracy | ±1% FS (CO/CO₂/CH₄/C₃H₈), ±2% FS (O₂/H₂S) |
| Resolution | 0.01% vol (low-range: 1 ppm) |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Flow Rate | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Output Interfaces | RS-485 / RS-232 / 4–20 mA / Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD |
| Explosion Protection | Ex d IIC T6 Gb / Ex tb IIIC T80°C Db |
| Sample Conditioning | Integrated front-end pretreatment (particulate filtration, moisture removal, oil rejection) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Type | Online Analyzer |
| Model | Gasboard-3500 (Standard) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) and Electrochemical Detection (ECD) |
| Response Time | T90 < 15 s (NDIR) |
| Repeatability | ≤1% FS for CO, CO₂, CH₄, C₃H₈ |
| Measurement Ranges | CO/CO₂/CH₄/C₃H₈: 0–100% vol |
| O₂ | 0–25% vol |
| H₂S | 0–9999 ppm |
| Accuracy | ±1% FS (NDIR gases), ±2% FS (O₂/H₂S) |
| Resolution | 0.01% vol (low-range equivalent to 1 ppm) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Electrical Interface | RS-485/RS-232, 4–20 mA, Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD with built-in diagnostics and auto-zero function using integrated air pump |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3600UV |
| Measurement Principle | UV-DOAS |
| Measured Gases | SO₂, NO, NO₂ |
| Range | 0–500 mg/m³ (each) |
| Accuracy | ≤±2% F.S. |
| Repeatability | ≤1% |
| Response Time | ≤30 sec @ T90 |
| Detection Limit | 0.01 mg/m³ (SO₂/NO/NO₂) |
| Sample Method | Hot-Wet Extraction |
| Optical Path | Multi-reflection long-path cell |
| Light Source | Pulsed Xenon Lamp |
| Measurement Chamber Temp. | 120–190 °C (adjustable) |
| Zero Drift | ≤2% F.S./24 h |
| Span Drift | ≤2% F.S./24 h |
| Communication | RS-232 / RS-485 |
| Power Supply | 220 VAC / 50 Hz |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800GHG |
| Detection Principle | Micro-flow NDIR (CO₂/CH₄/N₂O/CO), Dual-beam NDIR (high-range CO₂ & mid-high-range CO), Electrochemical (O₂) |
| Accuracy | ±1% F.S. (micro-flow NDIR) |
| Measured Gases | CO₂, CH₄, N₂O, CO, O₂ |
| Response Time | T₉₀ < 25 s |
| Repeatability | ≤ ±1% |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output | USB, analog, printer interface |
| Power | 100–240 VAC, 150 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800GHG |
| Instrument Type | Portable |
| Measured Gases | CO₂, CH₄, N₂O, CO, O₂ |
| Measurement Principle | Micro-flow NDIR (CO₂/CH₄/N₂O/CO), Dual-beam NDIR (CO₂/CO, high-range), Electrochemical (O₂) |
| Range (CO₂) | 0–500 ppm / 0–20% / 0–100% (configurable) |
| Range (CH₄/N₂O) | 0–1000 ppm |
| Range (CO) | 0–200 ppm / 0–5000 ppm / 0–5% |
| Range (O₂) | 0–25% |
| Accuracy | ±1% F.S. (micro-flow NDIR), ±2% F.S. (dual-beam NDIR & ECD) |
| Repeatability | ≤±1% |
| Response Time (T90) | <25 s |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output | USB, analog (4–20 mA), printer interface |
| Power | 100–240 VAC, 150 W |
| Self-diagnostic Function | Yes |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% F.S. (SO₂, NO, CO, CO₂, O₂) |
| Repeatability | ≤2% |
| Response Time | T₉₀ < 15 s (NDIR) |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Detection Principle | NDIR (SO₂/NO/CO/CO₂), Electrochemical (O₂) |
| Temperature Range | 0–800 °C |
| Flow Velocity Range | 3–40 m/s |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Power Supply | 100–240 VAC, 150 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800Plus |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ≤2% F.S. |
| Repeatability | ≤2% |
| Response Time | ≤30 s |
| Stability | ≤2% F.S./24 h |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Measurement Principles | Micro-flow NDIR (SO₂/NO/CO), Broadband NDIR (CO₂), Electrochemical Detection (O₂) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Dimensions | 275 × 470 × 175 mm |
| Weight | 7.5 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Display | LCD |