Gas Detector
Filter
Showing 511–540 of 1055 results
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800UV |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time | T90 < 15 s |
| Stability | ≤2% F.S./24 h |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5000 |
| Instrument Type | Online Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption + Electrochemical Detection (ECD) |
| Measured Gases | CO, HC, CO₂, O₂, NO |
| Zero Drift | ±1% FS for CO, HC, CO₂, O₂, NO |
| Span Drift | ±1% FS for CO, HC, CO₂, O₂, NO |
| Repeatability | ≤1% for all measured gases |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5100 |
| Instrument Type | Online Analyzer |
| Detection Principles | UV-DOAS (NO, NO₂), NDIR (HC, CO, CO₂), Electrochemical (O₂) |
| Measurement Ranges | HC (0–2000 ppm), CO (0.00–10.00%), CO₂ (0.0–16.0%), NO (0–4000 ppm), NO₂ (0–1000 ppm), O₂ (0.0–25.0%) |
| Accuracy | ±4 ppm or ±3% (HC, 2000 ppm range), ±0.02% or ±3% (CO), ±0.3% or ±3% (CO₂), ±25 ppm or ±4% (NO), ±25 ppm or ±4% (NO₂), ±0.1% or ±5% (O₂) |
| Resolution | HC/NO/NO₂: 1 ppm |
| CO/CO₂/O₂ | 0.01% |
| Response Time (T90) | HC/CO/CO₂ ≤8 s |
| Warm-up Time | 30 min |
| Communication | RS-485 / RS-232 |
| Power Supply | AC 100–240 V, 50 Hz ±2% |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5200 |
| Instrument Type | Online Analyzer |
| Detection Principles | Microflow Dual-Chamber NDIR (HC, CO, CO₂), PCT-Patented Microflow Infrared for NO, NDUV for NO₂, Long-Life Electrochemical Cell for O₂ |
| Measured Gases | HC, CO, CO₂, NO, NO₂, O₂ |
| Accuracy | HC ±4 ppm (0–2000 ppm), ±3% (2001–5000 ppm), ±5% (5001–9999 ppm) |
| Resolution | HC/NO/NO₂: 1 ppm |
| CO/CO₂/O₂ | 0.01% |
| Response Time (T90) | HC/CO/CO₂ ≤8 s |
| Warm-up Time | 30 min |
| Communication | RS-485 / RS-232 |
| Power Supply | AC 100–240 V, 50 Hz ±2% |
| Compliance | GB 18285-2018, GB 3847-2018, JJG 688-2017 Class 00 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5230 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Microflow Dual-Chamber Infrared (NO), NDUV (NO₂), NDIR (CO₂, CO, HC), Electrochemical (O₂) |
| Measured Gases | HC, CO, CO₂, NO, NO₂, O₂ |
| CO₂ Range | (0.0–16.0) % vol (±0.03 % vol or ±3%) |
| NO Range | (0–4000) ppm (±25 ppm or ±4%) |
| NO₂ Range | (0–1000) ppm (±25 ppm or ±4%) |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.01 % vol |
| Response Time (T₉₀) | CO₂ ≤ 8 s |
| Warm-up Time | 30 min |
| Communication | RS-485 / RS-232 |
| Power Supply | 100–240 VAC, 150 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5230 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Micro-flow Dual-chamber NDIR (for CO₂), PCT-patented Micro-flow Infrared with Dual-cell Design (for NO), NDUV Absorption (for NO₂) |
| Measured Gases | CO₂, NO, NO₂ |
| CO₂ Range | (0.0–16.0) % vol (±0.03 % vol or ±3% of reading) |
| NO Range | (0–4000) ppm (±25 ppm or ±4% of reading) |
| NO₂ Range | (0–1000) ppm (±25 ppm or ±4% of reading) |
| Resolution | CO₂: 0.01 % vol |
| NO/NO₂ | 1 ppm |
| Response Time (T90) | CO₂ ≤ 8 s |
| Warm-up Time | 30 min |
| Communication Interface | RS-485 / RS-232 |
| Power Supply | 100–240 VAC, 150 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-5230 |
| Instrument Type | Online Fixed-Mount Analyzer |
| Detection Principle | Microflow Dual-Chamber NDIR (NO), NDUV (NO₂), NDIR (CO₂) |
| Measured Gases | NO, NO₂, CO₂ |
| Accuracy | ±25 ppm or ±4% (NO/NO₂) |
| Resolution | 1 ppm (NO/NO₂), 0.01% vol (CO₂) |
| Response Time (T₉₀) | ≤10 s (NO/NO₂), ≤8 s (CO₂) |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 150 W |
| Communication Interface | RS-485 / RS-232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5230 |
| Instrument Type | Online Analyzer |
| Measurement Principles | Microflow Dual-Chamber Infrared (NO), Non-Dispersive Ultraviolet (NO₂), Non-Dispersive Infrared (CO₂) |
| Measured Gases | CO₂, NO, NO₂ |
| CO₂ Range | (0.0–16.0) × 10⁻² vol% (±0.3 × 10⁻² vol% or ±3%), (16.01–18.0) × 10⁻² vol% (±5%) |
| NO Range | (0–4000) × 10⁻⁶ vol% (±25 × 10⁻⁶ vol% or ±4%), (4001–5000) × 10⁻⁶ vol% (±8%) |
| NO₂ Range | (0–1000) × 10⁻⁶ vol% (±25 × 10⁻⁶ vol% or ±4%) |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.01% vol |
| Response Time (T₉₀) | CO₂ ≤ 8 s |
| Warm-up Time | 30 min |
| Communication Interface | RS-485 / RS-232 |
| Power Supply | 100–240 VAC, 150 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5230 |
| Instrument Type | Online Analyzer |
| Measurement Principles | Microflow Dual-Chamber Infrared (NO), Non-Dispersive Ultraviolet (NO₂), Non-Dispersive Infrared (CO₂) |
| Measured Gases | NO, NO₂, CO₂ |
| Measurement Ranges | NO (0–5000 ppm), NO₂ (0–1000 ppm), CO₂ (0.0–18.0 % vol) |
| Accuracy | NO/NO₂ ±25 ppm or ±4% (whichever greater in low range) |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.01 % vol |
| Response Time (T₉₀) | CO₂ ≤8 s |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 150 W |
| Communication Interface | RS-232 / RS-485 |
| Compliance | GB 3847–2018, JJG 688–2017 Class 00 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5230 |
| Instrument Type | Online Analyzer |
| Measurement Principles | Microflow Dual-Chamber NDIR (CO₂), PCT-Patented Microflow Infrared (NO), NDUV Absorption (NO₂) |
| Measured Gases | CO₂, NO, NO₂ |
| CO₂ Range | (0.0–16.0) × 10⁻² vol% (±0.3 × 10⁻² vol% or ±3%), (16.01–18.0) × 10⁻² vol% (±5%) |
| NO Range | (0–4000) × 10⁻⁶ vol% (±25 × 10⁻⁶ vol% or ±4%), (4001–5000) × 10⁻⁶ vol% (±8%) |
| NO₂ Range | (0–1000) × 10⁻⁶ vol% (±25 × 10⁻⁶ vol% or ±4%) |
| Resolution | CO₂: 0.01% vol |
| NO/NO₂ | 1 ppm |
| Response Time (T₉₀) | CO₂ ≤ 8 s |
| Warm-up Time | 30 min |
| Communication Interface | RS-485 / RS-232 |
| Power Supply | 100–240 VAC, 150 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5230P |
| Instrument Type | Online Analyzer |
| Detection Principle | UV Absorption Spectroscopy (NO, NO₂), Electrochemical (CO₂) |
| Measured Components | NO, NO₂, CO₂ |
| Measurement Range | 0–1500 ppm (NO), 0–1000 ppm (NO₂), 0–18% (CO₂) |
| Resolution | 1 ppm (NO/NO₂), 0.01% (CO₂) |
| Accuracy | ±4% FS (NO/NO₂), ±3% FS (CO₂) |
| Response Time | ≤5 s (all channels) |
| Warm-up Time | 800 s |
| Communication Interfaces | RS232, Wi-Fi |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 5–85% RH |
| Operating Pressure | 86–106 kPa |
| Power Supply | DC 12 V |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Model | Gasboard-5260 |
| Detection Principle | Microflow Dual-Chamber IR (NO), NDUV (NO₂), NDIR (HC, CO, CO₂), Electrochemical (O₂) |
| Measured Gases | HC, NO, NO₂, CO, CO₂, O₂ |
| Accuracy | Compliant with JJG 688–2017 Class 00 & GB 18285–2018 |
| Response Time (T₉₀) | HC/CO/CO₂ ≤ 8 s |
| Resolution | NO/NO₂ = 1 ppm |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 150 W |
| Communication Interface | RS-485 / RS-232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5260 |
| Instrument Type | Online Analyzer |
| Detection Principles | Micro-flow Dual-chamber NDIR (for HC, CO, CO₂), Electrochemical (ECD) for O₂, Micro-flow Infrared Dual-chamber Sensor for NO, Non-dispersive Ultraviolet (NDUV) for NO₂ |
| Measured Gases | HC, CO, CO₂, NO, NO₂, O₂ |
| Measurement Ranges | HC (0–9999 ppm), CO (0.00–14.00% vol), CO₂ (0.0–18.0% vol), NO (0–5000 ppm), NO₂ (0–1000 ppm), O₂ (0.0–25.0% vol) |
| Accuracy | Compliant with JJG 688–2017 Class 00 and GB 18285–2018 |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.01% vol |
| Response Time (T90) | HC/CO/CO₂ ≤ 8 s |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 150 W |
| Communication Interface | RS-232 / RS-485 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5260 |
| Instrument Type | Online Analyzer |
| Detection Principles | Micro-flow Dual-chamber NDIR (for HC, CO, CO₂), NDUV (for NO₂), Micro-flow Dual-chamber IR (for NO), Electrochemical (for O₂) |
| Measured Gases | HC, CO, CO₂, NO, NO₂, O₂ |
| Measurement Ranges | HC (0–9999 ppm), CO (0.00–14.00% vol), CO₂ (0.0–18.0% vol), NO (0–5000 ppm), NO₂ (0–1000 ppm), O₂ (0.0–25.0% vol) |
| Accuracy | Compliant with JJG 688-2017 Class 00 and GB 18285-2018 |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.01% vol |
| Response Time (T90) | HC/CO/CO₂ ≤ 8 s |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 150 W |
| Communication Interface | RS-485 / RS-232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5260 |
| Instrument Type | Online Analyzer |
| Measurement Principles | Microflow Dual-Chamber NDIR (HC, CO, CO₂), Electrochemical (O₂), Microflow Infrared with Dual-Chamber Compensation (NO), Non-Dispersive Ultraviolet (NDUV) Absorption (NO₂) |
| Measured Gases | HC, CO, CO₂, O₂, NO, NO₂ |
| Accuracy | As per GB 18285–2018 & JJG 688–2017 Class 00 |
| Zero Drift | < ±2% FS/8h |
| Span Drift | < ±2% FS/8h |
| Repeatability | ≤ ±1% FS |
| Response Time (T90) | HC/CO/CO₂ ≤ 8 s |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 150 W |
| Communication Interface | RS-232 / RS-485 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-6000 |
| Instrument Type | Portable |
| Measurement Principle | Transmissometry (Light Attenuation) |
| Measured Parameter | Visible Particulate Emissions from Compression-Ignition Engines |
| N Range | 0–99.99% |
| K Range | 0–16 m⁻¹ |
| Resolution | N ±0.1%, K ±0.01 m⁻¹ |
| Max Permissible Error | ±2.0% |
| Compliance | GB 3847–2018 |
| Temperature Control | Constant-Temperature Measurement Chamber |
| Output Interface | RS-232 / RS-485 |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-6100 |
| Instrument Type | Benchtop/Stationary Headlamp Tester |
| Measurement Principle | Dual-Camera Optical Imaging & Digital Image Processing |
| Luminous Intensity Range | 0–120,000 cd |
| Vertical Beam Axis Deviation (High/Low Beam) | ±2.5° to ±3° |
| Horizontal Beam Axis Deviation (High/Low Beam) | ±3° |
| Headlamp Height Range | 350–1400 mm |
| Luminous Intensity Accuracy | ≤±10% (at zero angular deviation), ≤±12% (full range) |
| Beam Axis Angle Accuracy | ≤±10′ (≤±3.2 cm/dam) |
| Height Measurement Accuracy | ≤±10 mm |
| Operating Temperature | −10 to +40 °C |
| Power Supply | 100–240 VAC, 250 W |
| Dimensions (W×D×H) | 800 × 670 × 1700 mm |
| Weight | ~100 kg |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-6200 |
| Instrument Type | Portable |
| Measurement Principle | Diffusion Charging Counting (DCC) |
| Measured Parameter | Particle Number Concentration in Exhaust Gas |
| Measurement Range | 5,000–10,000,000 #/cm³ |
| Particle Size Cutoff | ≥23 nm |
| Maximum Permissible Error | ≤±25% |
| Response Time (T₀–T₉₅) | <10 s |
| Operating Temperature | 0–55 °C |
| Power Supply | AC 100–230 V, 50–60 Hz |
| Startup Power Consumption | 700 W |
| Steady-State Power Consumption | 200 W |
| Heated Sample Line | 230 VAC or 110 VAC, customizable length |
| Output Interface | RS-232 (optional: RS-485, Bluetooth, 4G, Wi-Fi) |
| Dimensions (L×H×W) | 244×257×419 mm |
| Weight | <10 kg |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-6200 |
| Instrument Type | Portable |
| Measurement Principle | Diffusion Charging Counting (DCC) |
| Measured Parameter | Particle Number Concentration in Exhaust Gas |
| Measurement Range | 5×10³–1×10⁷ #/cm³ |
| Particle Size Cut-off | ≥23 nm |
| Maximum Permissible Error | ≤±25% |
| Response Time (T₀–T₉₅) | <10 s |
| Operating Temperature | 0–55 °C |
| Power Supply | AC 100–230 V, 50–60 Hz |
| Startup Power Consumption | 700 W |
| Steady-State Power Consumption | 200 W |
| Heated Sample Line | AC-powered (110/230 V), customizable length |
| Output Interface | RS-232 (optional: RS-485, Bluetooth, 4G, Wi-Fi) |
| Dimensions (L×H×W) | 244×257×419 mm |
| Weight | <10 kg |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-6200 |
| Instrument Type | Portable |
| Measurement Principle | Diffusion Charging (DC) Method |
| Measured Component | Exhaust Particulate Number Concentration |
| Particle Size Range | ≥23 nm |
| Accuracy (Indication Error) | ≤±25% |
| Zero Drift | Not Specified |
| Span Drift | Not Specified |
| Repeatability | Not Specified |
| Response Time | <10 s (T₀–T₉₅) |
| Operating Temperature | 0–55 °C |
| Power Supply | AC 100–230 V, 50–60 Hz |
| Startup Power Consumption | 700 W |
| Steady-State Power Consumption | 200 W |
| Dimensions (L×H×W) | 244 × 257 × 419 mm |
| Weight | <10 kg |
| Data Output Interface | RS-232 (optional RS-485, Bluetooth, 4G, Wi-Fi) |
| Heated Sample Line | AC-powered (110/230 V), customizable length |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-7800 |
| Instrument Type | Online |
| Measurement Principle | Ultrasonic & Vortex Shedding |
| Measured Components | O₂ |
| Flow Range | 4–12 m³/min |
| O₂ Range | 0.3–25% (v/v) |
| O₂ Resolution | 0.1% |
| O₂ Accuracy | ±0.1% (abs) or ±5% (rel) |
| Flow Accuracy | ±4% FS |
| Temperature Range | −30 to +150 °C |
| Temp Accuracy | ±1 °C |
| Pressure Range | 70.0–110.0 kPa |
| Pressure Accuracy | ±0.5 kPa or ±3% |
| Zero/Scale Drift (O₂) | ±2.5% FS |
| Repeatability | Flow ±2% FS |
| Response Time (O₂) | ≤5 s |
| Warm-up Time | <3 min |
| Humidity Range | 0–95% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Gasboard-8220 |
| Instrument Type | Portable |
| Measurement Principle | Vibration & Ignition Pulse Spectrum Analysis |
| Measured Parameter | Engine Speed (RPM) |
| Measurement Range | Gasoline Engines: 400–8000 rpm |
| Diesel Engines | 400–6000 rpm |
| Operating Temperature | 5–45 °C |
| Operating Humidity | 30–90 % RH |
| Power Supply | 12 VDC, 350 mA |
| Communication Interfaces | RS-232, TTL-level pulse output, analog ignition signal input |
| Display | LCD |
| Compliance | JJF 1375–2012 “Calibration Specification for Motor Vehicle Engine Tachometers” |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9007 |
| Output Flow Rate | ≥16 L/min |
| Output Pressure Range | 0–0.2 MPa |
| Hydrocarbon (as propane) | <1 ppmv |
| CO | <1 ppmv |
| CO₂ | <2 ppmv |
| O₂ | 20.8% ± 0.2% |
| NO | <1 ppmv |
| NO₂ | <1 ppmv |
| Dew Point Temperature | ≤−20 °C (H₂O ≤126 ppmv) |
| Power Supply | AC 220 V ± 22 V, 50 Hz ± 1 Hz |
| Air Inlet Requirement | Oil-free compressed air, ≥0.8 MPa, ≥1500 W, ≥15 L tank |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9021EX |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Detection Range | CO/CO₂/CH₄/H₂: (0–100)%, O₂: (0–25)%, C₂H₂/C₂H₄/CnHm: (0–10)% (optional) |
| Accuracy | ±1% FS (NDIR channels), ±2% FS (H₂/O₂) |
| Repeatability | ≤1% FS |
| Explosion Protection Rating | Ex d II C T4 Gb |
| Display | 10-inch capacitive touchscreen LCD |
| Output Interfaces | RS-232, RS-485, (4–20) mA analog, Ethernet |
| Auto-calibration | Built-in zero-air pump with automated air zeroing |
| Diagnostic Capability | Real-time sensor health monitoring and system self-diagnosis |
| Sample Conditioning | Integrated dual-stage filtration, steam-jacketed or straight-tube probe (user-selectable), single-stage refrigerative dryer |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CₙHₘ), TCD (H₂), ECD (O₂) |
| Detection Range | CO/CO₂/CH₄/H₂: (0–100)% vol |
| O₂ | (0–25)% vol |
| C₂H₂/C₂H₄/CₙHₘ | (0–10)% vol (optional) |
| Accuracy | ±1% FS (NDIR channels), ±2% FS (TCD & ECD channels) |
| Repeatability | ≤±0.5% FS |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Output Interfaces | RS-232, RS-485, (4–20) mA, Ethernet |
| Display | LCD |
| Auto-Calibration | Built-in zero-air pump with automatic air zeroing |
| Diagnostic Function | Real-time sensor health monitoring |
| Sample Handling | Heated stainless steel probe, dual-stage filtration, single-stage refrigerative dryer, pulsed back-purge |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Gasboard-9050 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Response Time | T90 < 60 s (NDIR) |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Measurement Principle | NDIR for SO₂/NO/CO/CO₂ |
| Range | SO₂/NO: 0–200 ppm |
| CO/CO₂/O₂ | 0–25 % vol |
| Accuracy | ±2 % FS |
| Resolution | SO₂/NO/CO/CO₂: 1 ppm |
| O₂ | 0.01 % vol |
| Repeatability | ±2 % FS |
| Operating Temperature Influence | ±5 % FS (5–35 °C) |
| Interference Gas Effect | ±5 % FS |
| Power Supply Variation Effect | ±2 % FS (±10 % AC voltage) |
| Optimal Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure Range | 2–50 kPa |
| Electrical Interface | RS-485 / RS-232 / 4–20 mA analog output |
| Power Supply | AC 220 V, 50 Hz |
| Built-in Features | Auto-diagnostic function, air zero calibration pump, automatic sampling, purging, and calibration sequences |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9050GHG |
| Instrument Type | Online CEMS |
| Measured Gases | CH₄, CO₂, CO, N₂O, O₂ |
| Measurement Principle | NDIR (CH₄/CO₂/CO/N₂O), Electrochemical Detection (O₂) |
| Range | CH₄/CO/N₂O: 0–1000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | ≤±1% F.S. (CH₄/CO₂/CO/N₂O), ≤±2% F.S. (O₂) |
| Repeatability | ≤±1% F.S. |
| Resolution | CH₄/CO/N₂O: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Response Time (T90) | <25 s |
| Linearity Error | ≤±1% F.S. (CH₄/CO₂/CO/N₂O), ≤±2% F.S. (O₂) |
| Sample Temperature Limit | 0–300 °C |
| Heated Sampling Line & Probe Temp | 120–180 °C |
| Enclosure Rating | IP54 |
| Dimensions (L×W×H) | 800 × 760 × 1800 mm |
| Ambient Temp | −20 to +50 °C |
| Ambient Humidity | <95% RH (non-condensing) |
| Power Supply | 220 V AC ±10%, >3000 W |
| Compressed Air Requirement | 0.4–0.8 MPa, oil-free, dust-free, dry |
| Max. Air Consumption | 2.2 m³/h |
| Avg. | 0.45 m³/h |
| Max. Sample Flow | 2 L/min |
| Avg. | 1.5 L/min |
| Communication Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Diagnostic Features | Real-time sensor health monitoring, automatic zero calibration via integrated air pump |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9050GHG |
| Measurement Principle | NDIR (CH₄/CO₂/CO/N₂O), Electrochemical (O₂) |
| Measurands | CH₄, CO₂, CO, N₂O, O₂ |
| Accuracy | ≤±1% F.S. (CH₄/CO₂/CO/N₂O), ≤±2% F.S. (O₂) |
| Repeatability | ≤±1% F.S. |
| Response Time (T90) | <25 s |
| Detection Limits | CH₄/CO/N₂O: 0–1000 ppm |
| CO₂/O₂ | 0–25% vol |
| Resolution | CH₄/CO/N₂O: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Flue Gas Temp. Range | 0–300 °C |
| Heated Line & Probe Temp. | 120–180 °C |
| Protection Rating | IP54 |
| Dimensions (L×W×H) | 800 × 760 × 1800 mm |
| Ambient Temp. | −20 to +50 °C |
| Humidity | <95% RH (non-condensing) |
| Power Supply | 220 V AC ±10%, >3000 W |
| Compressed Air Requirement | 0.4–0.8 MPa, oil-free, dust-free, moisture-free |
| Max. Air Consumption | 2.2 m³/h |
| Avg. | 0.45 m³/h |
| Max. Sample Flow | 2 L/min |
| Avg. | 1.5 L/min |
| Communication Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9050GHG |
| Instrument Type | Online CEMS |
| Measured Gases | CH₄, CO₂, CO, N₂O, O₂ |
| Detection Principle | NDIR (CH₄/CO₂/CO/N₂O), Electrochemical (O₂) |
| Range | CH₄/CO/N₂O: 0–1000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | CH₄/CO₂/CO/N₂O ≤ ±1% F.S. |
| Repeatability | ≤ ±1% F.S. |
| Resolution | CH₄/CO/N₂O: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Response Time (T₉₀) | < 25 s |
| Linearity Error | CH₄/CO₂/CO/N₂O ≤ ±1% F.S. |
| Operating Flue Gas Temp. | 0–300 °C |
| Heated Line & Probe Temp. | 120–180 °C |
| Protection Rating | IP54 |
| Dimensions (L×W×H) | 800 × 760 × 1800 mm |
| Ambient Temp. | −20 to +50 °C |
| Ambient Humidity | < 95% RH (non-condensing) |
| Power Supply | 220 V AC ±10%, >3000 W |
| Compressed Air Requirement | 0.4–0.8 MPa, oil-free, dust-free, moisture-free |
| Max. Air Consumption | 2.2 m³/h |
| Avg. | 0.45 m³/h |
| Sample Flow Rate | Max. 2 L/min |
| Communication Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-9056 |
| Measurement Principle | Forward Light Scattering (Laser) |
| Safety Rating | Explosion-Proof (Ex d IIB T4 Gb) |
| Measurement Range | 0–5 mg/m³ |
| Resolution | < 0.1 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤ ±20% |
| Sampling Method | Heated Extractive Probe with Hot-Wet Return |
| Isokinetic Sampling Capability | Yes |
| Maximum Sampling Flow Rate | 200 L/min |
| Operating Environment | -20°C to +60°C, RH ≤ 95% non-condensing, IP65 enclosure |
