Gas Detector
Filter
Showing 541–570 of 1055 results
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9070 |
| Measurement Principle | UV-DOAS |
| Measured Gases | SO₂, NO, NH₃ |
| Measurement Range (SO₂) | 0–1000 mg/m³ (desulfurization inlet), 0–50 mg/m³ (emission stack) |
| Measurement Range (NO) | 0–100 mg/m³ (inlet), 0–50 mg/m³ (emission) |
| Measurement Range (NH₃) | 0–20 mg/m³ (both inlet & outlet) |
| Accuracy | ≤ ±2% F.S. |
| Repeatability | ≤ 1% |
| Response Time (T₉₀) | ≤ 60 s |
| Resolution | 0.1 ppm |
| Operating Ambient Temperature | 0–50 °C |
| Power Supply | 220 V AC, 800 W |
| Purge Air Pressure | 0.4–0.8 MPa |
| Analog Outputs | 4 × 4–20 mA |
| Digital Outputs | 8 × relay |
| Communication Interfaces | RS485, RS232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9081 |
| Measurement Principle | UV-DOAS (NOx, SO₂), NDIR (CO, CO₂), Electrochemical (O₂) |
| Configuration | Online Multicomponent Gas Analyzer |
| Detection Range | NOx/SO₂: 0–100 mg/m³ |
| O₂/CO₂ | 0–25% vol |
| CO | 0–5% vol |
| Response Time | ≤30 s |
| Repeatability | ±1% FS (NO, SO₂, O₂) |
| Resolution | NOx/SO₂/CO: 1 mg/m³ |
| O₂/CO₂/CO | 0.01% vol |
| Zero Drift | NOx/SO₂: ≤1% FS/24 h |
| CO/CO₂/O₂ | ≤2% FS/24 h |
| Accuracy | ±2% FS (all measured components) |
| Power Supply | 220 V AC ±20%, 50 Hz ±1 Hz |
| Display | 7-inch capacitive touchscreen |
| Communication Interfaces | RS232, RS485, 4–20 mA analog output, audible/visual alarm relay |
| Data Storage | Internal non-volatile memory supporting ≥3 years of 1-minute interval data |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9082 (Standard Edition) |
| Principle | Electrochemical Detection (NO, O2, CO) & Non-Dispersive Infrared (NDIR) for CO₂ |
| Type | Online Fixed-Mount Analyzer |
| Measurement Range | NO: 0–100 mg/m³ |
| O₂ & CO₂ | 0–25% vol |
| CO | 0–5% vol |
| Response Time | ≤30 s |
| Repeatability | ±2% FS (NO, O₂, CO, CO₂) |
| Accuracy | ≤±3% FS |
| Power Supply | 220 V AC ±20%, 50 Hz ±1 Hz |
| Output Interfaces | RS232, RS485, 4–20 mA analog output, audible/visual alarm relay |
| Data Storage | Internal flash memory supporting ≥3 years of minute-interval historical data |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9085 |
| Principle | UV-DOAS / NDIR / ECD / CIDR |
| Type | Online Continuous Emission Monitoring System (CEMS) |
| Measurement Range | SO₂: 0–500 ppm |
| NO | 0–1000 ppm |
| CO | 0–10000 ppm |
| CO₂ | 0–25% vol |
| HC | 0–10000 ppm |
| O₂ | 0–25% vol |
| Response Time | ≤30 s |
| Accuracy | ±2% F.S. |
| Zero/Full-Scale Drift | ≤2% F.S./24 h |
| Repeatability | SO₂, CO₂, CH₄, N₂O, HC, O₂ |
| Sample Flow Rate | 6 L/min |
| Dew Point Output | ≤5 °C |
| Filtration | 5 µm → 0.1 µm dual-stage particulate filtration |
| Compliance | MARPOL Annex VI, GB 15097–2016, GD01–2011 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), and Flame Ionization Detection (HFID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Maximum Permissible Error | ≤±2.0% of Reading Standard (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Linearity | R² ≥ 0.998 |
| Slope | 0.99–1.01 |
| Operating Environment | 5–40 °C, ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), Flame Ionization Detection (FID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Max. Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Linearity | R² ≥ 0.998 |
| Operating Environment | 5–40 °C, ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Emission Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), Flame Ionization Detection (FID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Max. Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), Flame Ionization Detection (FID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Maximum Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), Flame Ionization Detection (FID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Max. Permissible Error | ≤±2.0% R.S. or ≤±0.3% F.S. |
| Zero Drift | ≤±1% F.S./8 h |
| Span Drift | ≤±1% F.S./8 h |
| Repeatability | ≤±0.5% F.S. |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9802 |
| Instrument Type | Online |
| Measurement Principle | Constant-volume dilution sampling with gravimetric and volumetric flow control |
| Max. Permissible Error | ±2% (propane spike verification) |
| Measured Species | Diluted exhaust emissions from vehicles and engines |
| Dilution Exhaust Flow Ranges | 1–12 m³/min |
| Diluted Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3 / 6 / 9 L/min |
| Sample Bag Configuration | 3 diluted air bags + 3 diluted exhaust bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 diluted exhaust + 1 diluted air |
| Particulate Sampling Chamber Temp. | 47 ± 5 °C |
| Dilution Air Filtration | Activated carbon + pre-filter + H13 HEPA filter |
| Operating Environment | 5–35 °C ambient temperature |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-9802 |
| Instrument Type | Online Fixed Installation |
| Measurement Principle | Constant Volume Sampling with Dilution Air Conditioning and Thermal Regulation |
| Max. Permissible Error | ±2% (Propane Spike Verification) |
| Measured Species | Diluted Exhaust Emissions from Vehicles and Engines |
| Dilution Exhaust Flow Ranges | 1–12 m³/min |
| Dilution Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3 / 6 / 9 L/min |
| Sample Bag Configuration | 3 Dilution Air Bags + 3 Diluted Exhaust Bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 Diluted Exhaust + 1 Dilution Air |
| Particulate Sampling Box Temperature | 47 ± 5 °C |
| Dilution Air Filtration | Activated Carbon Filter + Pre-filter + H13 HEPA Filter |
| Operating Environment | 5–35 °C Ambient Temperature |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Gasboard-9802 |
| Instrument Type | Online Fixed Installation |
| Measurement Principle | Constant Volume Sampling with Dilution Air Conditioning & Flow Control |
| Max. Permissible Error | ±2% (Propane Spike Verification) |
| Measured Species | Diluted exhaust emissions from engines and vehicles |
| Dilution Exhaust Flow Ranges | 1–12, 3–24, 9–60, or 30–150 m³/min |
| Diluted Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3 / 6 / 9 L/min |
| Sample Bag Configuration | 3 dilution air bags + 3 diluted exhaust bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 diluted exhaust + 1 dilution air |
| Particulate Sampling Box Temp. | 47 ± 5 °C |
| Dilution Air Filtration | Activated Carbon + Pre-filter + H13 HEPA |
| Operating Environment | 5–35 °C ambient temperature, ≤80% RH, 80–102 kPa atmospheric pressure |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9802 |
| Instrument Type | Online |
| Measurement Principle | Dilution-based gravimetric/volumetric sampling per ISO 8178 & UNECE R49 |
| Max. Permissible Error | ±2% (propane spike verification) |
| Measured Species | Diluted exhaust emissions from engines and vehicles |
| Dilution Exhaust Flow Range | 1–12, 3–24, 9–60, or 30–150 m³/min (configurable) |
| Diluted Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3, 6, or 9 L/min |
| Sample Bag Configuration | 3 dilution air bags + 3 diluted exhaust bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 diluted exhaust + 1 dilution air |
| Particulate Chamber Temperature Control | 47 ± 5 °C |
| Dilution Air Filtration | Activated carbon + pre-filter + H13 HEPA |
| Operating Environment | 5–35 °C, ≤80% RH, 80–102 kPa |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-9802 |
| Instrument Type | Online System |
| Measurement Principle | Dilution-based gravimetric/volumetric sampling with thermal and flow stabilization |
| Max. Permissible Error | ±2% (propane spike verification) |
| Measured Emission Sources | Laboratory-based exhaust testing of newly manufactured mobile sources (engines & light/heavy-duty vehicles) |
| Dilution Exhaust Flow Ranges | 1–12, 3–24, 9–60, or 30–150 m³/min |
| Diluted Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3, 6, or 9 L/min |
| Sample Bag Configuration | 3 dilution air bags + 3 diluted exhaust bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 diluted exhaust + 1 dilution air |
| Particulate Sampling Box Temperature | 47 ± 5 °C |
| Dilution Air Filtration | Activated carbon + pre-filter + H13 HEPA filter |
| Operating Environment | 5–35 °C ambient temperature, ≤80% RH, 80–102 kPa atmospheric pressure |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9805 |
| Instrument Type | Portable |
| Measurement Principles | NDIR (CO, CO₂, O₂), Electrochemical (O₂), UV-LED Differential Optical Absorption Spectroscopy (DOAS) for NO/NO₂ |
| Measured Gases | CO, CO₂, O₂, NO, NO₂, NOₓ (calculated) |
| Zero Drift (CO) | ≤±50 ppm / 4 h |
| Span Drift (CO) | ≤±2% of reading or ≤±50 ppm / 4 h |
| Resolution | CO/NO/NO₂: 0.1 ppm |
| CO₂/O₂ | 0.01% |
| Response Time (T₉₀) | ≤2.5 s (gas module) |
| Repeatability | Not specified |
| Optional Modules | Particulate Number (PN) counter (6×10²–1.3×10⁹ #/cm³, 23 nm–2.5 µm), Total Hydrocarbons (THC), Exhaust Flow Meter (EFM) with thermal mass flow principle, integrated GPS and environmental sensors (T, RH, Pₐₜₘ) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9805 |
| Instrument Type | Portable |
| Measured Gases | CO, CO₂, NO, NO₂, NOₓ, O₂, THC |
| Zero Drift | ≤±1% FS/8 h |
| Span Drift | ≤±1% FS/8 h |
| Repeatability | ≤±0.5% FS |
| Detection Principle | NDIR (CO, CO₂), NDUV (NO, NO₂), HFID (THC), Corona Charging + CPC (PN), Electrochemical/NDIR (NH₃/N₂O) |
| Operating Temperature | −10 to 45 °C |
| Relative Humidity | ≤90% RH |
| Altitude Range | 0–3000 m |
| Exhaust Flow Range | 10–2000 kg/h |
| THC Range | 0–10,000 ppmC |
| PN Size Cut-off | 10 nm or 23 nm |
| NH₃ Range | 0–1000 ppm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Measurement Principle | NDIR (CO, CO₂), NDUV (NO, NO₂), HFID (THC), Corona Charging + CPC (PN), Electrochemical/NDIR (NH₃/N₂O) |
| Measured Gases | CO, CO₂, NO, NO₂, NOₓ, O₂, THC, NH₃, N₂O, PN (≥10 nm or ≥23 nm) |
| Accuracy | ≤±2.0% of Reading or ≤±0.3% of Full Scale |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s (gas), <1 s (flow), <5 s (PN) |
| Operating Temperature | –10 to +45 °C |
| Relative Humidity | ≤90% RH |
| Altitude Range | 0–3000 m |
| Exhaust Flow Range | 10–2000 kg/h |
| Exhaust Temp Range | –5 to +500 °C |
| Battery Life | >8 h (Li-ion) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9805* |
| Instrument Type | Portable |
| Measurement Principles | NDIR (CO, CO₂), NDUV (NO, NO₂), HFID (THC), Corona Discharge CPC (PN), Electrochemical/NDIR (NH₃/N₂O) |
| Measured Gases | CO, CO₂, NO, NO₂, NOₓ, O₂, THC, NH₃, N₂O, PN (≥10 nm or ≥23 nm) |
| Max. Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Operating Temperature | −10 to +45 °C |
| Relative Humidity | ≤90% RH |
| Altitude Range | 0–3000 m |
| Exhaust Flow Range | 10–600 kg/h or 100–2000 kg/h |
| Exhaust Temp. Range | −5 to +500 °C |
| Battery Life | >8 h (Li-ion) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3000 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sampling Method | In-situ extraction |
| Measurement Range | 0–10 ppm NH₃ |
| Accuracy | ±1% of Full Scale |
| Response Time | <30 s |
| Repeatability | ±1% of Full Scale |
| Operating Ambient Temperature | −30 °C to +70 °C |
| Resolution | 0.01 ppm |
| Power Supply | DC 24 V (heating: AC 220 V) |
| Communication Interfaces | RS-232, RS-485 |
| Storage Conditions | −40 °C to +85 °C |
| Enclosure Rating | IP65 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3000 |
| Measurement Range | 0–10 ppm NH₃ |
| Accuracy | ±1% F.S. |
| Response Time | <30 s |
| Operating Ambient Temperature | −30 °C to +70 °C |
| Resolution | 0.01 ppm |
| Repeatability | ±1% F.S. |
| Power Supply | DC 24 V (heating: AC 220 V) |
| Communication | RS-232 / RS-485 |
| Storage Conditions | −40 °C to +85 °C |
| Ingress Protection | IP65 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3001 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sampling Method | In-situ |
| Measurement Range | 0–10–100 ppm (adjustable) |
| Accuracy | ±1% F.S. |
| Response Time (T90) | ≤30 s |
| Repeatability | ±1% |
| Operating Ambient Temperature | −30 to +60 °C |
| Protection Rating | IP65 or higher |
| Resolution | 0.01 ppm |
| LOD | ±1% F.S. |
| Power Supply | 220 VAC, 50 Hz, 800 W |
| Purge Air | 0.4–0.8 MPa compressed air |
| Communication | 1× RS-232, 1× RS-485 |
| Analog Outputs | 4× 4–20 mA |
| Digital Outputs | 8× relay |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GasTDL-3001 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sampling Method | In-situ |
| Measurement Range | 0–10–100 ppm (field-selectable) |
| Accuracy | ±1% F.S. |
| Response Time (T90) | ≤30 s |
| Repeatability | ±1% |
| Operating Ambient Temperature | −30 to +60 °C |
| Protection Rating | IP65 |
| Resolution | 0.01 ppm |
| LOD | ±1% F.S. |
| Power Supply | 220 VAC, 50 Hz, 800 W |
| Purge Air | 0.4–0.8 MPa compressed air |
| Communication | 1× RS-232, 1× RS-485 |
| Analog Outputs | 4× 4–20 mA |
| Digital Outputs | 8× relay |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3001 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sampling Method | In-situ |
| Measurement Range | 0–10–100 ppm (adjustable) |
| Accuracy | ±1% F.S. |
| Response Time (T90) | ≤30 s |
| Repeatability | ±1% |
| Operating Ambient Temperature | −30 to +60 °C |
| Protection Rating | IP65 |
| Resolution | 0.01 ppm |
| Lower Detection Limit | ±1% F.S. |
| Power Supply | 220 VAC, 50 Hz, 800 W |
| Purge Air | 0.4–0.8 MPa compressed air |
| Communication | 1× RS-232, 1× RS-485 |
| Analog Outputs | 4× 4–20 mA |
| Digital Outputs | 8× relay |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3001 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sampling Method | In-situ |
| Measurement Range | 0–10–100 ppm (selectable) |
| Accuracy | ±1% of Full Scale (F.S.) |
| Response Time (T90) | ≤30 s |
| Repeatability | ±1% F.S. |
| Operating Ambient Temperature | −30 to +60 °C |
| Resolution | 0.01 ppm |
| Detection Limit | ±1% F.S. |
| IP Rating | IP65 or higher |
| Power Supply | 220 VAC, 50 Hz, 800 W |
| Purge Air | 0.4–0.8 MPa compressed air |
| Communication | 1× RS-232, 1× RS-485 |
| Analog Outputs | 4× 4–20 mA |
| Digital Outputs | 8× relay |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3001 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sampling Method | In-situ |
| Measurement Range | 0–10–100 ppm (selectable) |
| Accuracy | ±1% F.S. |
| Response Time (T90) | ≤30 s |
| Repeatability | ±1% |
| Operating Ambient Temperature | −30 to +60 °C |
| Resolution | 0.01 ppm |
| LOD | ±1% F.S. |
| IP Rating | IP65 |
| Power Supply | 220 VAC, 50 Hz, 800 W |
| Purge Gas | Compressed air, 0.4–0.8 MPa |
| Communication | 1× RS-232, 1× RS-485 |
| Analog Outputs | 4× 4–20 mA |
| Digital Outputs | 8× relay |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3001 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sampling Method | In-situ (Hot Extractive) |
| Measurement Range | 0–10–100 ppm (selectable) |
| Accuracy | ±1% of Full Scale (F.S.) |
| Response Time (T90) | ≤30 s |
| Repeatability | ±1% F.S. |
| Operating Ambient Temperature | −30 to +60 °C |
| IP Rating | IP65 or higher |
| Resolution | 0.01 ppm |
| LOD | ±1% F.S. |
| Power Supply | 220 VAC, 50 Hz, 800 W |
| Purge Air | 0.4–0.8 MPa compressed air |
| Communication | 1× RS-232, 1× RS-485 |
| Analog Outputs | 4× 4–20 mA |
| Digital Outputs | 8× relay |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3001 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sampling Method | In-situ extraction |
| Measurement Range | 0–10–100 ppm (field-selectable) |
| Accuracy | ±1% F.S. |
| Response Time (T90) | ≤30 s |
| Repeatability | ±1% |
| Operating Ambient Temperature | −30 to +60 °C |
| Resolution | 0.01 ppm |
| Detection Limit | ±1% F.S. |
| IP Rating | IP65 |
| Power Supply | 220 VAC, 50 Hz, 800 W |
| Purge Air | 0.4–0.8 MPa compressed air |
| Communication | 1× RS-232, 1× RS-485 |
| Analog Outputs | 4× 4–20 mA |
| Digital Outputs | 8× relay |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Installation Type | In-situ transmittance (line-of-sight) |
| Measured Gases | H₂S, O₂, CO, CO₂, CH₄ |
| O₂ Range | 0–5 %vol (customizable to 0–100 %vol) |
| Response Time | T90 ≤ 1 s |
| Repeatability | ≤ ±1 %FS |
| Accuracy | ≤ ±1 %FS |
| Zero/ Span Drift | ≤ ±1 %FS per 30 days |
| Resolution | 0.01 %vol (O₂), 0.01 ppm (H₂S) |
| Explosion Protection | Exd II CT6 Gb / Ex tb IIIC T80°C Db |
| Operating Temperature | −20 to +60 °C |
| Power Supply | 24 V DC, 24 W |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Output | 2 × 4–20 mA, 3 × relay |
| Communication | RS485, RS232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100-CH4 |
| Instrument Type | In-situ Online Analyzer |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gases | CH₄, O₂, CO, CO₂, H₂S |
| CH₄ Range | 0–20 %VOL |
| O₂ Range | 0–5 %VOL (customizable to 0–100 %VOL) |
| CO Range | 0–100 %VOL |
| CO₂ Range | 0–100 %VOL |
| H₂S Range | 0–100 ppm / 0–5000 ppm |
| Accuracy | ≤ ±1 %FS |
| Repeatability | ≤ ±1 %FS |
| Zero/ Span Drift | ≤ ±1 %FS/7d |
| Resolution | 0.01 %VOL (CH₄) |
| Response Time (T90) | ≤ 4 s |
| Ambient Temp. | −20 to +60 °C |
| Power Supply | 24 V DC, 24 W |
| Enclosure Rating | Exd II CT6 |
| Output | 2 × 4–20 mA, 3 × Relay |
| Communication | RS485, RS232 |
| Purge Gas | Industrial N₂, 0.3–0.8 MPa |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100-CO |
| Instrument Type | In-situ online analyzer |
| Measured Gas | CO (primary), with optional multi-component capability (O₂: 0–5% vol, CO₂: 0–100% vol, CH₄: 0–20% vol) |
| Accuracy | ≤±1% F.S. |
| Repeatability | ≤±1% |
| Resolution | 0.01% vol |
| Response Time (T90) | ≤4 s |
| Span Drift | ≤±1% F.S. |
| Linearity Error | ≤±1% F.S. |
| Operating Temperature | −20 to +60 °C |
| Power Supply | 24 V DC, 24 W |
| Explosion Protection | Exd II CT6 |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Output Signals | 2 × 4–20 mA, 3 × relay |
| Communication | RS485, RS232 |