Gas Detector
Filter
Showing 571–600 of 1055 results
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100-CO2 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Configuration | In-situ, dual-beam transmission |
| Measured Gas | CO₂ (single-component mode) |
| O₂ Range | (0–5)% vol (customizable up to 100% vol) |
| CO Range | (0–100)% vol |
| CO₂ Range | (0–100)% vol |
| CH₄ Range | (0–20)% vol |
| Accuracy | ≤±1% FS |
| Repeatability | ≤±1% FS |
| Zero/Full-Scale Drift | ≤±1% FS per 30 days |
| Resolution | 0.01% vol |
| Response Time (T90) | ≤4 s |
| Operating Temperature | −20 to +60 °C |
| Power Supply | 24 V DC, 24 W |
| Explosion Protection | Ex d II CT6 |
| Output Signals | 2 × 4–20 mA analog outputs, 3 × relay outputs |
| Communication | RS485, RS232 |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable UAV-Mounted Gas Analyzer |
| Detection Principle | Mid-Infrared Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Analyte | CH₄ |
| Measurement Range | Not specified (CH₄-specific) |
| Detection Limit | <100 ppb (CH₄), <15 ppb (C₂H₆) |
| Optical Path | Open-Path |
| Data Acquisition Rate | 10–20 Hz |
| Sensitivity | <100 ppb (CH₄) |
| Weight | <3 kg |
| Software Features | Leak event identification & quantification, deep learning–enabled pattern recognition |
| Enclosure Material | Corrosion-Resistant Alloy |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Measured Species | CH₄, C₂H₆ |
| Optical Path Configuration | Sealed Absorption Cell |
| Detection Limit (CH₄) | <100 ppb |
| Detection Limit (C₂H₆) | <15 ppb |
| Data Acquisition Rate | 10–20 Hz |
| Included Accessories | GNSS Positioning System (BeiDou-compatible), Ultrasonic Anemometer |
| Compliance Context | Designed for field-deployable ambient air monitoring per EPA Method 21 principles and ISO 13864:2022 guidance on mobile gas leak detection |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Online Analyzer |
| Measurement Principle | Zirconia Limiting-Current Electrochemistry + Thick-Film Catalytic Oxidation |
| Detection Range | O₂: 0–25% vol |
| COe | 0–10,000 ppm |
| Response Time | O₂: T₉₀ ≤ 10 s |
| COe | T₉₀ ≤ 20 s |
| Accuracy | O₂: ±1% FS or ±0.2% vol |
| COe | ±5% FS or ±25 ppm |
| Resolution | O₂: 0.01% vol |
| COe | 1 ppm |
| Communication | RS-485 / MODBUS RTU |
| Analog Outputs | 2 × 4–20 mA |
| Alarm Outputs | 3 configurable relay outputs |
| Environmental Operating Range | Control Unit: −40°C to +65°C |
| Sensor Unit | −40°C to +120°C |
| IP Rating | IP66 |
| Probe Materials | S316L stainless steel, Alloy 600, Alumina (Al₂O₃) |
| Flange Mounting | DN50 (customizable) |
| Probe Length | Customizable |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | CUBIC-EMX-4N |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Integrated TDLAS + UV-DOAS + GFC Infrared Spectroscopy |
| Measured Components | NH₃, NO, NO₂, N₂O |
| Measurement Range (NH₃) | 0–100 ppm (low), 0–5000 ppm (high) |
| Measurement Range (NO) | 0–200 ppm (low), 0–5000 ppm (high) |
| Measurement Range (NO₂) | 0–200 ppm (low), 0–3000 ppm (high) |
| Measurement Range (N₂O) | 0–200 ppm (low), 0–5000 ppm (high) |
| Sample Gas Line Temperature | 113 °C ± 6 °C |
| Sample Flow Rate | 8.0 L/min ± 1.0 L/min |
| Operating Ambient Temperature | 5–40 °C |
| Operating Relative Humidity | ≤80 % RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Portable Engine Emission Analyzer |
| Instrument Type | Portable |
| Detection Principle | UV-DOAS / NDUV / NDIR |
| Max. Permissible Error | NO/NO₂: ±2% rel. or ±25 ppm abs. |
| CO₂ (0–16%) | ±3% rel. or ±0.3% abs., (16–18%): ±5% rel. |
| Opacity (K) | ±2.0% rel. |
| Measurement Range | NO: 0–4000 ppm |
| NO₂ | 0–1000 ppm |
| CO₂ | 0–18% vol |
| K | 0–16 m⁻¹ |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.1% vol |
| K | 0.01 m⁻¹ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Species | CH₄ |
| Methane Concentration Range | 0.01%–100% vol |
| Emission Flux Range | 0.01–13 kg/h |
| Measurement Accuracy | ±5% of reading |
| Sampling Flow Rate | up to 400 L/min |
| Battery Runtime | >8 h |
| Charging Time | 10 h |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Standalone Version |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Nephelometric Absorption) |
| Maximum Permissible Error | ±2.0% |
| Display | Integrated LCD Monitor |
| Sampling Probe | Fixed-length, heat-resistant stainless steel probe |
| Optional | Built-in thermal printer |
| Compliance | GB 3847–2018, GB 36886–2018 |
| Electrical Interface | RS-232 / RS-485 digital output & print port |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Measurement Range | Opacity N: 0–99.99% |
| Absorption Coefficient K | 0–16 m⁻¹ |
| Resolution | N: 0.1% |
| K | 0.01 m⁻¹ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Standard Edition |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Filter-Based Nephelometry) |
| Max. Permissible Error | ±2.0% for Opacity (N) and Absorption Coefficient (K) |
| Opacity Range | 0–99.99% (Resolution: 0.1%) |
| K-Value Range | 0–16 m⁻¹ (Resolution: 0.01 m⁻¹) |
| Engine Speed | 400–6000 rpm (Resolution: 1 rpm |
| Accuracy | ±10 rpm or ±1%) |
| Ambient Temperature | −20–60 °C (Resolution: 0.1 °C |
| Accuracy | ±4% rel. or ±0.5 °C abs.) |
| Relative Humidity | 5–99% RH (Resolution: 0.1% RH |
| Accuracy | ±5% rel. or ±3% RH abs.) |
| Atmospheric Pressure | 70–106 kPa (Resolution: 0.01 kPa |
| Accuracy | ±5% rel. or ±2 kPa abs.) |
| Oil Temperature (optional) | 0–200 °C (Resolution: 1 °C |
| Accuracy | ±5 °C abs.) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Instrument Type | Online Fixed-Position Analyzer |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Maximum Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Measured Gases | NH₃, N₂O |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Minimum Range | 0–50 ppm (NH₃), 0–100 ppm (N₂O) |
| Maximum Range | 0–2000 ppm (both) |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Linearity | R² ≥ 0.998 |
| Operating Environment | 5–40 °C, ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Zero Air Flow Rate | 1.0 L/min |
| Operating Pressure | 80–106 kPa |
| Measurement Components | CO, CO₂, C₃H₈, NO, NO₂, O₂ |
| Measurement Principles | GFC + NDIR (CO, CO₂, C₃H₈), UV-DOAS (NO, NO₂), TD-LAS/ECD (O₂) |
| Range | 0–20 ppm (CO, NO, NO₂), 0–40 ppm (CO₂, C₃H₈), 0–25% (O₂) |
| LOD | 0.05 ppm (gases), 0.05% (O₂) |
| Accuracy | ≤ ±2% F.S. (CO/CO₂/C₃H₈/NO/NO₂), ≤ ±0.2% (O₂) |
| Interfaces | RS-232, RS-485, USB |
| Power Input | 220 VAC ±10% |
| Operating Temp. | 5–40 °C |
| Humidity | 0–90% RH |
| Design | Modular, thermally stabilized, portable benchtop unit |
| Brand | Cubic |
|---|---|
| Model | JT-AM5301 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gas | CH₄ |
| Range | 0–100% LEL |
| Accuracy | ±3% LEL |
| Alarm Threshold | 10% LEL |
| Response Time | <30 s (diffusion) |
| Operating Temp. | −10°C to +50°C |
| Humidity | 0–90% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 3 W |
| IP Rating | IP30 (per GB 23757) |
| Compliance | GB 15322.2–2019, CCC Fire Certification (3CF) |
| Communication | NB-IoT (default), optional Wi-Fi or 4G |
| Sensor Lifetime | ≥10 years |
| Dimensions | 84 × 84 × 33.5 mm |
| Weight | 240 g |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MS-VOC |
| Pricing | Available Upon Request |
| Target Gases | Formaldehyde, Benzene, CO, H₂, Ethanol, NH₃, Cigarette Smoke |
| Preheat Time | 180 s |
| Operating Temperature | −10 °C to 50 °C |
| Storage Temperature | −20 °C to 60 °C |
| Response Time | ≤30 s |
| Rated Voltage | DC 5 V ±0.2 V |
| Output Interface | UART (5 V logic) or 0–3 V analog |
| Dimensions | 24 mm × 20 mm × 5 mm |
| Power Design | Constant-power operation |
| Calibration | Factory-calibrated |
| Stability | Long-term baseline stability |
| Power Consumption | Low-power operation |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MS-VOC-V4 |
| Pricing | Upon Request |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPC-6303DS |
| Instrument Type | Online |
| Flow Rate | 2.83 L/min |
| Detection Principle | Light Scattering |
| Particle Size Channels | 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm |
| Counting Efficiency | 50% @ 0.3 μm, 100% @ ≥0.5 μm (25±2°C, 50±10% RH) |
| Accuracy Compliance | JJF 1190 |
| Power Supply | DC 12–24 V |
| Operating Temp. | 0–45°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Display | 3.5-inch color LCD |
| Communication Interfaces | RS485 (standard), RJ45 Ethernet (standard), 4–20 mA output (standard), MQTT/TCP/IP support |
| Data Update Interval | 1 s |
| Warm-up Time | ≤8 s |
| IP Rating | IP44 |
| Lifetime | ≥3 years |
| Optional | Visual/audible alarm module (LED strobe + 110 dB siren) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPC-6303M |
| Instrument Type | Online |
| Detection Principle | Optical Scattering |
| Particle Size Range | 0.3–10 μm |
| Counting Efficiency | 50% at 0.3 μm, 100% ≥0.5 μm (per TSI 9306 reference, 25±2°C, 50±10% RH) |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Operating Temperature | 0–45°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temp/Humidity | −20–60°C / 0–95% RH (non-condensing) |
| Power Supply | DC 12 V |
| Avg. Current Draw | ≤1 A |
| Flow Rates | 2.83 L/min (Class 10,000 cleanroom), 28.3 L/min (Class 1,000 cleanroom) |
| Output Channels | 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm (pcs/L) |
| Compliance | JJF 1190 |
| Standard Interface | RS485 |
| Optional Interfaces | RJ45 Ethernet, 4–20 mA analog output |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPC-6510 |
| Flow Rate | 28.3 L/min |
| Flow Accuracy | Compliant with JJF-1190 |
| Timing Accuracy | Compliant with JJF-1190 |
| Size Distribution Accuracy | Compliant with JJF-1190 |
| Indication Error | Compliant with JJF-1190 |
| Detection Principle | Light Scattering |
| Channel Count | 6 (0.3, 0.5, 1.0, 2.5, 5.0, 10.0 µm) |
| Counting Efficiency | 50% at 0.3 µm |
| Measurement Range | 0–1,000,000 particles per 28.3 L |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Operating Temp. | 0–45°C |
| Operating RH | 0–95% non-condensing |
| Storage Temp./RH | −20–60°C / 0–95% non-condensing |
| Power Supply | DC 24 V |
| Avg. Current Draw | ≤3 A |
| Communication | RS485 (standard), RJ45 (optional) |
| Service Life | ≥3 years |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPC-6510DS |
| Instrument Type | Online Particle Counter |
| Flow Rate | 28.3 L/min |
| Channel Sizes | 0.3 µm, 0.5 µm, 1.0 µm, 5.0 µm, 10.0 µm |
| Counting Efficiency | 50% at 0.3 µm |
| Measurement Range | 0–1,000,000 pcs/28.3 L |
| Accuracy Compliance | JJF 1190–2008 |
| Display | 3.5-inch color TFT screen |
| Power Supply | DC 24.0 V ±15%, ≤3 A avg. |
| Communication Interfaces | RS485 (standard), RJ45 Ethernet (standard) |
| Protocol Support | TCP/IP, MQTT |
| Unit Options | pcs/28.3 L or pcs/m³ |
| Operating Temp. | 0–45°C |
| RH | 0–95% non-condensing |
| Storage | −20–60°C, 0–95% RH non-condensing |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Sampling Probe | Isokinetic probe with Ø10 mm internal diameter tubing (≤3 m length) |
| Duty Cycle | Configurable (default: 2 min active / 28 min sleep) |
| Lifetime | ≥3 years |
| Calibration Standard | JJF 1190–2008 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPC-6511DS |
| Instrument Type | Handheld |
| Flow Rate | 28.3 L/min |
| Counting Channels | 0.3 µm, 0.5 µm, 1.0 µm, 5.0 µm, 10.0 µm |
| Counting Efficiency | 50% @ 0.3 µm, 100% @ ≥0.5 µm (25±2°C, 50±10% RH) |
| Measurement Range | 0–1,000,000 pcs/28.3 L |
| Display | 7-inch color TFT LCD |
| Power Supply | DC 24.0 V ±15% |
| Battery Standby Duration | >5 h (2 min active / 28 min sleep cycle) |
| Communication Interfaces | RS485 (standard), RJ45 Ethernet (standard) |
| Compliance | JJF 1190–2008 |
| Warm-up Time | ≤8 s |
| Data Refresh Interval | 1 s |
| Operating Temperature | 0–45°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −20–60°C, 0–95% RH (non-condensing) |
| Sampling Probe | Isokinetic, external tube ID φ10 mm, max length 3 m |
| Lifetime | ≥3 years |
| Unit Options | pcs/28.3 L or pcs/m³ (switchable) |
| Protocol Support | TCP/IP, MQTT |
| Calibration Support | Standard source coefficient correction |
| Language Interface | English / Chinese toggle |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPM-6303M |
| Measurement Principle | Optical Light Scattering |
| Safety Rating | Non-Explosion-Proof |
| Measurement Range | 0–30 mg/m³ |
| PM₁.₀/PM₂.₅ Accuracy | ±10 µg/m³ (≤100 µg/m³), ±10% of reading (100–1000 µg/m³) |
| PM₁₀ Accuracy | ±15 µg/m³ (≤100 µg/m³), ±15% of reading (100–1000 µg/m³) |
| TSP Accuracy | ±20 µg/m³ (≤100 µg/m³), ±20% of reading (100–1000 µg/m³) |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Operating Temperature | −30 to +70 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −40 to +85 °C |
| Power Supply | DC 12 V |
| Average Current Draw | ≤4.5 A |
| Communication Interface | RS485 |
| Sampling Flow Rate | 1 L/min (standard, customizable) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM1006 |
| Detection Principle | Optical Scattering (Infrared LED + Photodiode) |
| Measurement Range | 0–1000 µg/m³ |
| Accuracy | ±20 µg/m³ or ±20% of reading (at 25°C ±2°C, 50% ±10% RH, calibrated against TSI AM510/8530 reference) |
| Warm-up Time | ≤8 s |
| Operating Temperature | −20°C to +75°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −40°C to +85°C |
| Supply Voltage | DC 5.0 V ±0.2 V (ripple <50 mV) |
| Operating Current | ≤30 mA |
| Output Interfaces | UART TTL (logic level 4.5 V), PWM (4.5 V) |
| Dimensions | 46.2 × 34.1 × 18 mm (W×H×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM1007 |
| Detection Principle | Optical Light Scattering (Nephelometry) |
| Measurement Range | 0–5 mg/m³ |
| Accuracy | ±30 µg/m³ or ±30% of reading (at 25±2 °C, 50%±10% RH) |
| Warm-up Time | 8 s |
| Operating Temperature | −20 °C to +75 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −40 °C to +85 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.2 V (ripple <100 mV) |
| Operating Current | ≤30 mA |
| Output Interfaces | UART (4.5 V logic level), PWM (4.5 V logic level) |
| Dimensions | 66.8 × 38.8 × 21.6 mm (W×H×D) |
| Expected Service Life | ≥5 years |
| Electromagnetic Shielding | Integrated |
| Particle Size Sensitivity | 0.3–10 µm |
| Application Domain | Commercial Kitchen Exhaust Monitoring, Fume Hood Compliance Verification, Local Emission Control Systems |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PM2008 |
| Pricing | Available Upon Request |
| Detection Principle | Laser Light Scattering |
| PM2.5 Measurement Range | 0–1000 µg/m³ |
| Accuracy | ±10 µg/m³ or ±10% of reading (at 25°C ±2°C, 50% RH ±10%, calibrated against TSI AM510/8530 reference instrument) |
| Operating Temperature | −10°C to +50°C |
| Storage Temperature | −20°C to +60°C |
| Housing Material | Full Metal Enclosure (EMI-Shielded) |
| Dimensions (PM2008) | 47.8 mm (W) × 36.8 mm (H) × 11.7 mm (D) |
| Airflow Configuration | Co-planar inlet/outlet on wide face (PM2008/PM2008M) |
| Output Interfaces | UART, PWM, I²C |
| Thickness | ≤12.1 mm |
| Particle Recognition | Intelligent Source Discrimination Algorithm (Cubic Proprietary) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM2008MSE |
| Detection Principle | Optical Scattering (Laser Nephelometry) |
| Measurement Range | 0–1000 µg/m³ (PM1.0, PM2.5, PM10) |
| Resolution | 0.3 µm |
| Accuracy (PM2.5) | ±10 µg/m³ (≤100 µg/m³), ±10% of reading (>100 µg/m³) |
| Accuracy (PM10) | ±20 µg/m³ (≤100 µg/m³), ±20% of reading (>100 µg/m³) |
| Data Update Interval | 1 s |
| Warm-up Time | ≤8 s |
| Operating Temperature | −10 to +50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −20 to +60 °C, 0–95% RH |
| Supply Voltage | DC 5 V ±0.1 V (ripple <50 mV) |
| Operating Current | ≤100 mA |
| Standby Current | ≤200 µA |
| Interface | UART (3.3 V logic), I²C (3.3 V logic) |
| Dimensions | 48 × 40 × 12 mm (W × H × D) |
| Shielding | Full-metal EMI enclosure |
| Design | Ultra-thin profile (12 mm height) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PM2009 |
| Pricing | Available Upon Request |
| Detection Principle | Laser Light Scattering |
| PM2.5 Range | 0–1000 μg/m³ (extendable to PM1.0 and PM10) |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Accuracy | ±10 μg/m³ or ±10% of reading (at 25°C±2°C, 50%±10% RH |
| Operating Temperature | −10°C to +60°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Storage Conditions | −30°C to +70°C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5.0 V ±0.1 V (ripple <100 mV) |
| Operating Current | ≤100 mA |
| Standby Current | <25 mA |
| Output Interfaces | UART TTL (3.3 V / 5 V logic), I²C (reserved), PWM (reserved) |
| Dimensions | 50 × 38 × 21 mm (W × H × D) |
| Enclosure | Metal-shielded housing |
| Structural Feature | Integrated self-cleaning mechanism with co-located inlet/outlet airflow path |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM2012 |
| Pricing | Upon Request |
| Detection Principle | Laser Light Scattering |
| PM2.5 Range | 0–1000 µg/m³ (extendable to PM1.0 & PM10) |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Accuracy | ±10 µg/m³ or ±10% of reading (at 25°C±2°C, 50%±10% RH |
| Operating Temp. | −10°C to +60°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Storage Temp. | −30°C to +70°C |
| Storage Humidity | 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.5 V (ripple <50 mV) |
| Operating Current | ≤100 mA |
| Standby Current | ≤200 µA |
| Output Interfaces | UART TTL (3.3 V / 5 V logic), I²C (3.3 V) |
| Dimensions | 38 mm × 35 mm × 12 mm (W×H×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM2105 |
| Pricing | Available Upon Request |
| Detection Principle | Laser Light Scattering |
| PM2.5 Range | 0–1000 µg/m³ |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Accuracy | ±15 µg/m³ or ±15% of reading (at 25°C ±2°C, 50% RH ±10%, referenced to TSI AM510/8530) |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Storage Conditions | −30°C to +60°C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5.0 V ±0.1 V (ripple <50 mV) |
| Operating Current | ≤100 mA |
| Standby Current | <20 mA |
| Output Interfaces | UART TTL (3.3 V), I²C (3.3 V / 5 V compatible), PWM (reserved) |
| Dimensions | 42 × 35 × 23.7 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PM2107 |
| Pricing | Available Upon Request |
| Operating Principle | Laser Light Scattering |
| Measurement Range | 0–1000 µg/m³ |
| Accuracy | ±15 µg/m³ or ±15% of reading |
| Detection Principle | Laser Scattering |
| PM2.5 Range | 0–1000 µg/m³ |
| Power-On Stabilization Time | ≤8 s |
| Data Update Interval | 1 s |
| Environmental Conditions (Calibration) | 25°C ±2°C, 50% RH ±10%, referenced to TSI AM510/8530 |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Storage Temperature | −30°C to +60°C |
| Storage Humidity | 0–95% RH (non-condensing) |
| Supply Voltage | DC 5.0 V ±0.1 V, ripple <50 mV |
| Operating Current | ≤100 mA |
| Standby Current | <20 mA |
| Output Interfaces | UART TTL (3.3 V logic), PWM (default 5 V, 3.3 V configurable) |
| Dimensions | 58.7 mm (W) × 45 mm (H) × 13.9 mm (D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM3003Q |
| Price | USD 630 (FOB) |
| Operating Principle | Laser Light Scattering |
| Safety Rating | Non-Explosive Atmosphere Rated |
| Measurement Range | 0–50 mg/m³ (max display: 1000 mg/m³) |
| Accuracy | ±200 µg/m³ for 0–1 mg/m³ |
| Detection Principle | Optical Scattering |
| Recommended Sample Flow Rate | 2 L/min |
| Data Update Interval | 1 s |
| Operating Temperature | 30–70 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Storage Temperature | −40–85 °C |
| Storage Humidity | 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ± 0.2 V (ripple < 100 mV) |
| Average Current Consumption | <150 mA |
| Standby Current | <25 mA |
| Interface | UART (TTL 3.3 V logic level) |
| Dimensions | 90.8 × 60.2 × 37.6 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM3003S |
| Measurement Principle | Laser Light Scattering (90° Detection Geometry) |
| Safety Rating | Explosion-Proof (Ex ib IIB T4 Gb) |
| Measurement Range | 0–1000 µg/m³ |
| Accuracy | PM1.0: ±10 µg/m³ or ±10% of reading |
| PM2.5 | ±10 µg/m³ or ±10% of reading |
| PM10 | ±15 µg/m³ or ±15% of reading |
| TSP | ±20 µg/m³ or ±20% of reading |
| Sampling Flow Rate | 1.0 L/min (pump-assisted) |
| Data Refresh Interval | 1 s |
| Operating Temperature | −30 °C to +70 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Power Supply | DC 5.0 V ±0.1 V (ripple <50 mV) |
| Current Consumption | <150 mA (operational), <25 mA (standby) |
| Output Interfaces | Analog voltage (0–5 V or 0–10 V configurable), UART TTL (3.3 V logic level) |
| Dimensions | 82 × 40.2 × 26.3 mm (W × H × D) |
