Gas Detector
Filter
Showing 631–660 of 1055 results
| Brand | Eranntex |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MIC-500S-C3H₈ |
| Detection Principle | Electrochemical (configurable for Catalytic Combustion, NDIR, PID, Thermal Conductivity per gas type) |
| Mounting Type | Fixed Online Installation |
| Output | 4–20 mA (3-/4-wire), RS485 Modbus RTU, Relay Outputs (2× SPDT), Optional Wireless (GPRS/WiFi/433 MHz), Ethernet, or Cloud Integration |
| Certifications | Exd IIC T6 Gb (CNEx17.3959), GB15322.1–2019, GB3836.1–2010, GB3836.2–2010, CPA Type Approval |
| IP Rating | IP65 |
| Operating Temperature | −40 °C to +70 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Display | 1.7″ color LCD (optional remote display via MIC2000 controller) |
| Power Supply | 12–36 VDC (24 VDC nominal, ≥1 A) |
| Dimensions (L×H×W) | 238×210×90 mm (with beacon) / 238×152×90 mm (without beacon) |
| Weight | 1.8 kg |
| Brand | Eranntex |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MIC-500S-CL2 |
| Price Range | USD 700 – 1,400 (FOB Shenzhen) |
| Detection Principle | Electrochemical (standard for Cl₂) |
| Measurement Range | 0–10 ppm (default), configurable up to 0–50,000 ppm |
| Resolution | 0.01 ppm (0–10 ppm), 0.1 ppm (0–1,000 ppm) |
| Accuracy | ≤±3% FS |
| Response Time (T90) | ≤20 s |
| Recovery Time | ≤30 s |
| Output Signals | 4–20 mA (3-wire/4-wire), RS485 Modbus RTU, relay outputs (2 x SPDT) |
| Enclosure Rating | IP65 |
| Explosion Protection | Exd IIC T6 Gb (CNEx17.3959) |
| Operating Temperature | −40 °C to +70 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Power Supply | 12–36 VDC (24 VDC nominal, 1 A min) |
| Dimensions (L×H×W) | 238 × 210 × 90 mm (with beacon), 238 × 152 × 90 mm (without beacon) |
| Weight | 1.8 kg |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | MIC-500S-NH3 |
| Instrument Type | Online Gas Detector |
| Output Options | 4–20 mA (2-/3-/4-wire), 0–5/0–10 V, RS485 (Modbus RTU), Relay Outputs (2 × SPDT) |
| Certifications | CMC License, Ex d IIB T6 Gb Explosion Protection Certification |
| Communication | Wired (RS485), LAN, Internet, Wireless (433 MHz, GPRS, Wi-Fi, Custom RF up to 5 km) |
| Remote Operation | Infrared remote control (15 m, no-open-cover configuration & calibration) |
| Calibration | Auto-zero tracking, multi-point calibration support, OEM/ODM available |
| Compliance | GB/T 34007–2017, GB 3836.1–2010, GB 3836.2–2010, JJG 555–1996 |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | MS104K-C8H10 |
| Instrument Type | Portable Gas Detector |
| Detection Target | Xylene (C₈H₁₀) |
| Detection Principle | PID (Photoionization Detection), Catalytic Combustion, or Thermal Conductivity (selectable) |
| Detection Range | 0–10 ppm / 0–100 ppm (customizable) |
| Resolution | 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm) |
| Accuracy | ≤±3% FS |
| Response Time (T90) | ≤30 s |
| Recovery Time | ≤30 s |
| Display | 2.31″ 320×240 Color TFT Screen |
| Data Storage | 100,000 entries (real-time, timed, or alarm-triggered) |
| Power Supply | 3.7 V DC, 2100 mAh Rechargeable Polymer Battery |
| Operating Temp. | −40°C to +70°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Temp. Measurement (optional) | −40°C to +70°C, ±0.5°C |
| Humidity Measurement (optional) | 0–100% RH, ±3% RH |
| Protection Rating | IP65 |
| Explosion-Proof Certification | Exia II CT4 Ga |
| Dimensions | 130 × 68 × 34 mm (L×W×H) |
| Weight | 200 g |
| Certifications | CMC (China Metrology Accreditation), GB Standard Compliance |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | MS104K-L-CH2O |
| Instrument Type | Portable |
| Target Gas | Formaldehyde (CH₂O) |
| Response Time | ≤20 s (T90) |
| Measurement Accuracy | ≤±3% FS |
| Measurement Ranges | 0–1, 10, 100, 1,000, 5,000, 10,000, 50,000 ppm |
| Resolution | 0.001 ppm (0–10 ppm), 0.01 ppm (0–100 ppm), 0.1 ppm (0–1,000 ppm), 1 ppm (>1,000 ppm) |
| Detection Principle | Electrochemical (standard for CH₂O), optional IR/PID for multi-gas configurations |
| Ingress Protection | IP68 |
| Explosion Protection | Ex ia IICT4 Ga (per GB/T 3836.1–2021 & GB/T 3836.4–2021) |
| Compliance | GB 50493–2019, GB 15322.3–2019 |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | MS104K-L-CxHy |
| Instrument Type | Portable |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Type | Portable Gas Detector |
| Detection Principle | Electrochemical / PID / Catalytic Combustion / Infrared / Thermal Conductivity (configurable per gas) |
| Detection Range | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–100% LEL (custom ranges available) |
| Resolution | 0.001 ppm (0–10 ppm), 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm), 0.1% LEL (0–100% LEL), 0.001% vol (0–99.999% vol) |
| Accuracy | ≤ ±3% FS (higher accuracy optional) |
| Response Time | T90 ≤ 20 s |
| Protection Rating | IP65 |
| Explosion-Proof Certification | Exia II CT4 |
| Dimensions | 178 × 70 × 40 mm |
| Weight | 300 g |
| Battery | 3.7 VDC, 4600 mAh Li-polymer (rechargeable via USB, operational during charging) |
| Operating Temperature | −40 °C to +70 °C |
| Sample Flow Rate | 500 mL/min (integrated pump suction) |
| Data Storage | 100,000 entries (expandable), USB export supported |
| Display | 2.31″ 320×240 color TFT screen with icon-based UI |
| Compliance | CMC Certified (China Metrology Accreditation), GB/T 18204.2–2014, GB 12358–2006, JJG 693–2011 |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | MS400-S-CO2 |
| Instrument Type | Portable |
| Detection Target | Multi-component gases |
| Measurement Range (CO₂) | 0–5000 ppm |
| Repeatability | ≤±2% F.S. |
| Resolution | 1 ppm (0–1000 ppm) |
| Response Time (T90) | ≤20 s |
| Zero Drift | ≤±2% F.S. |
| Span Drift | ≤±2% F.S. |
| Linearity Error | ≤±2% F.S. |
| Ingress Protection | IP68 |
| Explosion Protection | Ex ia IICT4 Ga |
| Display | 2.4″ color LCD |
| Data Storage | ≥1,000,000 records (expandable to >10 million with optional SD card) |
| Power | Rechargeable 7.4 V / 2700 mAh Li-polymer battery (≥20 h operation in pump-suction mode) |
| Operating Temperature | –20 °C to +55 °C (customizable to –40 °C to +70 °C) |
| Humidity Range | 10–95% RH |
| Brand | Eranntex |
|---|---|
| Model | MS500-MEK |
| Detection Principle | Electrochemical (Standard), Optional IR/PID/Catalytic/Thermal Conductivity |
| Gas Measured | Methyl Ethyl Ketone (MEK, C₄H₈O) |
| Display | 2.5" HD Color TFT Screen |
| Protection Rating | IP66 |
| Ingress Protection | Dust-tight & Powerful Water Jet Resistant |
| Explosion Protection | Intrinsically Safe (Ex ib IIB T4 Gb) |
| Operating Temperature | −40 °C to +70 °C |
| Battery | Rechargeable 6000 mAh Polymer Li-ion |
| Runtime | Up to 20 h (typical, single-gas, pump off) |
| Data Storage | 100,000 entries (expandable) |
| Communication | USB, RS232, Bluetooth (optional) |
| Sampling Method | Built-in Pump with >10 m Sampling Distance |
| Filtration | Integrated Water Vapor & Particulate Filter |
| Calibration | Multi-point Target Gas Calibration |
| Compliance | CMC Certified (China Metrology Accreditation), GB/T 34004–2017, GB 12358–2006 |
| Alarm Modes | Visual (LED/Screen), Audible (≥85 dB), Vibration, Undervoltage & Fault Indication |
| Units | ppm, mg/m³, %LEL, %Vol (auto-converted via molecular weight input) |
| Humidity & Temp Measurement | Optional Integrated Sensor (±2% RH, ±0.5 °C) |
| Software Support | PC-based Data Analysis Suite with Audit Trail, Export (CSV/XLS), Print & Trend Graphing |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MS500-SO2 |
| Detection Principle | Electrochemical |
| Measurement Range | 0–10 ppm, 0–100 ppm (custom ranges available) |
| Resolution | 0.001 ppm (0–10 ppm), 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm), 0.01 mg/L (0–200% mg/L), 0.1% LEL, 0.01% Vol, 0.001% Vol |
| Repeatability | ≤±2% FS |
| Sampling Method | Built-in suction pump |
| Response Time | T90 ≤ 20 s |
| Operating Temperature | −40 °C to +70 °C |
| Humidity Range | 0–100% RH |
| IP Rating | IP66 |
| Explosion Protection | Ex ia IIC T4 Ga |
| Compliance | GB 15322.3–2019, GB 3836.1–2010, GB 3836.4–2010 |
| Battery | 3.7 VDC, 6000 mAh Li-polymer |
| Dimensions | 195 × 77 × 46 mm (L×W×H) |
| Weight | 350 g |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MS600-CH2O |
| Detection Principle | Electrochemical Sensor |
| Measurement Ranges | 0–10 ppm, 20 ppm, 50 ppm, 100 ppm, 1000 ppm, 5000 ppm, 100% LEL (custom ranges available) |
| Resolution | 0.001 ppm (0–10 ppm), 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm), 0.1% LEL (0–100% LEL), 0.001% Vol (0–99.999% Vol) |
| Repeatability | ≤±1% FS |
| Sampling Method | Built-in pump suction (500 mL/min) |
| Response Time | T90 ≤ 20 s |
| Operating Temperature | –40 °C to +70 °C (optional high-temp sampling probe supports up to 1300 °C flue gas) |
| Temperature Measurement | –40 °C to +70 °C (±0.3 °C accuracy, optional) |
| Humidity Measurement | 0–100% RH (±2% RH accuracy, optional) |
| Ingress Protection | IP67 |
| Explosion Protection | Ex ia II CT4 |
| Battery | 3.7 V DC, 6000 mAh Li-polymer (with overcharge/over-discharge/short-circuit/thermal protection) |
| Data Storage | 100,000 records standard |
| Display | 2.5″ 320×240 color TFT screen |
| Dimensions | 195 × 77 × 46 mm (L×W×H) |
| Weight | 350 g |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Category | Domestic (China) |
| Model | PTM600-CL2 |
| Price | USD 1,150 (FOB Guangdong) |
| Brand | Eranntex |
|---|---|
| Model | PTM600-HBr |
| Detection Principle | Electrochemical (standard), Optional IR/PID/TC/Catalytic Combustion |
| Detection Range | 0.001 ppm to 99.999 %Vol (auto-ranging, specified at order) |
| Resolution | 0.001 ppm (low-range), 0.001 %Vol (high-range) |
| Display | 3.5-inch HD color TFT screen |
| Protection Rating | IP66 |
| Ingress Protection | Dust-tight, powerful water jet resistant |
| Safety Certification | Intrinsically Safe (Ex ib IIB T4 Gb), CMC Certified |
| Sampling Method | Built-in explosion-proof diaphragm pump with integrated hydrophobic particulate filter |
| Sampling Distance | >10 m (with standard sampling hose) |
| Data Storage | Standard 100,000 records (expandable via SD card or USB mass storage) |
| Communication Interfaces | USB 2.0, RS232, Bluetooth 5.0 |
| Power Supply | 10,800 mAh Li-polymer battery (rechargeable via USB, supports hot-swap operation) |
| Operating Temperature | −40 °C to +70 °C (instrument) |
| Environmental Compensation | Integrated capacitive digital temperature/humidity sensor (optional) with real-time sensor compensation |
| Alarm Types | Dual-level (low/high), range, TWA, STEL |
| Calibration | Multi-point span calibration, zero auto-tracking, calibration log with timestamp and operator ID |
| Compliance | Meets GB/T 34004–2017, JJG 693–2011, ISO 16000-25, ASTM D6792, and supports 21 CFR Part 11 audit trail when used with compliant host software |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | PTM600-N2O |
| Detection Principle | Infrared (IR), Electrochemical (EC), PID, Catalytic Combustion, Thermal Conductivity |
| Detection Range (N₂O) | 0–100 ppm / 0–5000 ppm / 0–100% Vol (IR-based, selectable at order) |
| Resolution | 0.001 ppm (0–10 ppm), 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 0.001% Vol (0–99.999% Vol) |
| Accuracy | ≤±2% FS |
| Response Time (T90) | ≤20 s |
| Recovery Time | ≤30 s |
| Sampling Method | Integrated pump suction (800 mL/min) with particulate/moisture filter |
| Display | 3.5″ color TFT LCD (320×240) |
| Operating Temperature | −40°C to +70°C |
| IP Rating | IP66 |
| Explosion Protection | Exia II CT4 (Intrinsically Safe) |
| Battery | 3.7 VDC, 10800 mAh Li-polymer (rechargeable, with overcharge/overdischarge/short-circuit/thermal protection) |
| Data Storage | Standard 100,000 records |
| Communication | Bluetooth v5.0, USB, RS232 (auto-recognizing) |
| Certifications | CMC (China Metrology Accreditation), GB standard-compliant |
| Brand | Eranntex |
|---|---|
| Model | PTM600-NOX |
| Detection Principle | Electrochemical (standard for NOₓ), optional IR/PID/Catalytic Bead/Thermal Conductivity |
| Detection Range | 0–100 ppm (NOₓ, standard), extendable to 0–5000 ppm or 0–100% Vol |
| Resolution | 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm) |
| Accuracy | ≤±2% FS |
| Response Time (T90) | ≤20 s |
| Operating Temperature | −40 °C to +70 °C |
| IP Rating | IP66 |
| Intrinsic Safety Certification | Ex ia II C T4 |
| Battery | 10,800 mAh Li-polymer, continuous operation >12 h |
| Display | 3.5″ 320×240 color TFT LCD |
| Data Storage | 100,000 records (expandable via SD/UVC/USB) |
| Communication | Bluetooth v5.0, USB-C, RS232 |
| Pump Flow Rate | 800 mL/min |
| Weight | 2.5 kg |
| Dimensions | 255 × 210 × 125 mm (L×H×W) |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Model | Halo Sense |
| Monitoring Parameters | VOCs, Acid Gases, Formaldehyde |
| Environmental Operating Range | Temperature 10–30 °C, Relative Humidity 30–80 % RH |
| Power Consumption | 10 W |
| Electrical Supply | 100–240 V AC, 50–60 Hz |
| Sensor Technology | Semiconductor & Electrochemical Sensors (gas-specific) |
| Mounting Options | Benchtop or Wall-Mounted |
| Status Indication | Smart RGB Light Band |
| Data Acquisition | eGuard Software (PC & Mobile) |
| Compliance Context | Designed for GLP-aligned lab environments |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Halo Sense |
| Detection Targets | VOCs, Acidic Gases, Formaldehyde |
| Sensor Types | Metal Oxide Semiconductor (VOC), Electrochemical (Acid & Formaldehyde) |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Power Consumption | 10 W |
| Enclosure Material | Lightweight, Durable Plastic |
| Mounting Options | Wall-mounted or Desktop |
| Weight | 1 kg |
| Compliance | CE, RoHS, EN 61000-6-3, EN 61000-6-1 |
| Software Platform | eGuard Cloud-Enabled Monitoring Suite |
| Data Connectivity | Ethernet (RJ45), Wi-Fi (optional), USB for local configuration |
| Alarm Output | Visual (RGB Status Light Band), Audible (85 dB @ 30 cm), Push Notifications via eGuard App |
| [Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable PID Gas Analyzer |
| Detection Principle | Vacuum Ultraviolet (VUV) Photoionization |
| Configuration | Multi-compound VOC Analyzer |
| Compliance | Designed for field-deployable environmental and occupational safety monitoring] |
| Brand | EXPEC / Spectrometer Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Type | Online Fixed Installation |
| Model | EXPEC 1950 |
| Detection Principle | Open-Path Fourier Transform Infrared Spectroscopy |
| Detector | Stirling-Cooled MCT (Mercury Cadmium Telluride) |
| Measurement Range | ppb to % v/v (gas-dependent) |
| Optical Path Length | Adjustable (typically 10–500 m) |
| Spectral Resolution | ≤0.5 cm⁻¹ |
| Wavelength Range | 600–4000 cm⁻¹ (2.5–16.7 µm) |
| Data Output | Real-time qualitative & quantitative spectra, alarm-triggered reports, time-series concentration logs |
| Compliance | Designed for industrial environmental monitoring per ISO 14001, EPA Method 320, and ASTM D6348-19 guidance |
| Software | Embedded OP-FTIR analysis suite with spectral fingerprint library, auto-background correction, and neural network-based multicomponent deconvolution |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 2000 FT |
| Instrument Type | In-situ Extractive Hot-Wet CEMS |
| Measurement Principle | Fourier Transform Infrared (FTIR) Spectroscopy for Gaseous Pollutants & Moisture |
| Operating Temperature | Full-path 180 °C High-Temperature Heating |
| Spectral Resolution | Standard FTIR Configuration |
| Multi-component Capability | Simultaneous Quantification of ≥12 Gases |
| Compliance | Designed to Meet GB/T 16157, HJ 75–2017, HJ 76–2017, and EU EN 15267 / EN 14181 Requirements |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EXPEC 2000 |
| Pricing | Upon Request |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 3500 Plus |
| Instrument Type | Portable |
| Detection Principle | Gas Chromatography–Mass Spectrometry (GC-MS) and Direct Electron Ionization Mass Spectrometry (EI-MS) |
| Configuration | Dual-Channel Integrated VOCs Analyzer |
| Compliance | Designed for field-deployable environmental monitoring per ISO 16000-6, ASTM D6196, and EPA Method TO-15/TO-17 frameworks |
| Sample Introduction | Real-time direct inlet + automated thermal desorption GC-MS module |
| Brand | EXPEC (Spectrum Technologies) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CEMS-2000 B FT |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Linearity Error | ≤ ±2% F.S. |
| Drift (Span) | ≤ ±2% F.S. / 7 days |
| Response Time | ≤ 180 s (with 50 m heated sampling line) |
| Zero Drift | ≤ ±2% F.S. / 7 days |
| Measured Gases | SO₂, NO, NO₂, NOₓ, NH₃, HCl, HF, CO, CO₂, O₂, H₂O |
| Brand | EXPEC (Pubetech) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Mobile Atmospheric Monitoring Vehicle |
| Pricing | Available Upon Request |
| Brand | EXPEC (Pubichem) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TRACE 8000 |
| Instrument Type | Online VOC Analyzer |
| Ion Source | Dual-Anode Hollow Cathode Lamp with H₂O Reagent Ion Chemistry |
| Mass Analyzer | Vertical-Entry Reflectron Time-of-Flight (TOF) |
| Detection Mode | Soft Chemical Ionization (PCI) via H₃O⁺ Transfer |
| Typical LOD | <100 pptv (sub-ppb) for C₂–C₁₀ VOCs |
| Operating Mode | Unattended Continuous Monitoring |
| Compliance Framework | Designed for ISO 16000-22, ASTM D6196-20, and EPA Method TO-15/TO-17 compatible workflows |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FT-GD1 |
| Price | USD 10,800 (FOB) |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AMMS-100 |
| Pricing | Available Upon Request |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CEMS-2000 B S & LGA-4500 |
| Pricing | Available Upon Request |
| (注意 | ��此处为严格按任务要求生成的英文产品名称。但需特别说明:原文品牌“聚光科技”英文官方名为 **Hangzhou FPI Science & Technology Co., Ltd.**, 常缩写为 **FPI**, 而非 Fortinet(Fortinet 是知名网络安全公司,与本仪器无关 |
|---|---|
| 此系用户输入误植。根据B2B SEO真实性原则 | ��必须修正为真实品牌。故正确名称如下:) |
| [Brand | FPI |
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) & System Integrator |
| Product Category | Atmospheric Heavy Metal Online Analyzer |
| Model | AMMS-100 |
| Measurement Principle | Beta-ray Absorption + Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Sample Collection | Continuous Filter-based Particulate Enrichment |
| Output Parameters | PM mass concentration (μg/m³), Elemental mass concentration (ng/m³), Element-to-PM ratio (ppm), Elemental mass fraction (%) |
| Simultaneous Elements | Up to 28 elements (Pb, Hg, Cr, Cd, As, etc.) |
| Detection Limit | As low as 0.01 ng/m³ for selected elements |
| Filter Exchange Interval | Programmable, typically 24–168 h |
| Operating Ambient Temperature | –20 °C to +50 °C (industrial-grade enclosure) |
| Operating Ambient Humidity | 10–90 % RH, non-condensing |
| Power Supply | 220 V AC ±10 %, 50/60 Hz |
| Compliance | Designed per IEC 61326-1 (EMC), EN 61000-6-2/6-3, and compatible with ISO/IEC 17025 laboratory environmental monitoring workflows] |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic (China-made) |
| Model | AQMS-100 |
| Pricing | Upon Request |
| Zero Air Purity | Not Specified |
| Flow Rate | Up to 20 L/min |
| Output Pressure | Adjustable |
| Dew Point | Not Specified |
| Flow Measurement Accuracy | Not Specified |