Gas Detector
Filter
Showing 661–690 of 1036 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000B |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Measurement Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±0.5% FS/24h (Span Drift) |
| Response Time | ≤ 200 s |
| Stability | ≤ ±1% FS/24h (Zero Drift) |
| Measured Parameters | Gaseous Pollutants (SO₂, NO, NO₂, CO, CO₂, O₂), Particulate Matter (PM), Temperature, Pressure, Flow Velocity, Humidity |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000B Hg |
| Pricing | Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Flue Gas Heavy Metal Analyzer |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Elemental Coverage | Pb, Hg, Cr, Cd, As, and up to 26 heavy metals (expandable via spectral library calibration) |
| Detection Limit | < 0.1 µg/m³ (for key elements under ISO 14927-compliant sampling conditions) |
| Filter Replacement Interval | ≥ 30 days (typical, dependent on particulate loading) |
| Operating Ambient Temperature | 0–40 °C |
| Operating Ambient Humidity | 10–90 % RH (non-condensing) |
| Operating Ambient Pressure | 86–106 kPa |
| Compliance | Meets China’s HJ 1131–2020 and EU EN 14385 technical requirements for continuous heavy metal emission monitoring |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | FPI DS7000 Series |
| Safety Rating | Explosion-Proof (Class I, Division 1, Groups C/D |
| Measurement Principle | Electrostatic Induction Sensing |
| Compliance | CE, RoHS, GB/T 18204.1–2013 (China), IEC 60079-0:2017, IEC 60079-1:2014 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Atmospheric Heavy Metal & VOC Online Analyzer |
| Model | Expec-3000 |
| Compliance | Designed for ISO 16000-6, ASTM D6196, USP <467>, and EPA TO-15/TO-17 workflows |
| Sample Introduction | Cryogenic pre-concentration coupled with thermal desorption |
| Detection Modes | Dual-channel GC-FID (C₂–C₅ hydrocarbons) and GC-MS (C₆–C₁₂ & oxygenated VOCs) |
| Analyte Coverage | >100 target VOCs including alkanes, alkenes, aromatics, halocarbons, aldehydes, ketones, esters, and organic acids |
| Data Handling | Fully automated peak integration, spectral deconvolution, and NIST library matching |
| System Architecture | 19″ rack-mountable, air-cooled cryogenic module, integrated GLP-compliant audit trail |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Extractive FTIR |
| Configuration | Online Continuous Monitoring System |
| Optical Resolution | 1 cm⁻¹ |
| Effective Path Length | Adjustable from 10 m to 64 m |
| Detector Operating Temperature | −196 °C (Liquid Nitrogen Cooled MCT) |
| Detection Limit | Sub-ppb for Selected Analytes |
| Spectral Library | >300 Certified Reference Spectra (Developed with Anhui Institute of Optics and Fine Mechanics, CAS |
| Simultaneous Quantification | ≥20 Gaseous Species (e.g., VOCs, CO, CO₂, NH₃, SO₂, NO, HCl, HF, CH₄) |
| Interference Compensation | Multi-point Calibration + Multi-spectral Band Fitting Algorithm |
| Sample Handling | Direct Extractive Sampling — No Pre-concentration or Chemical Derivatization Required |
| Compliance Readiness | Designed for ASTM D6348, ISO 12039, EPA Method 320, and GLP/GMP-aligned Data Integrity Frameworks |
| Software Architecture | Supports 21 CFR Part 11 Audit Trail, Electronic Signatures, and Secure Data Export (CSV, XML, PDF) |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GC955-615/815 |
| Detection Principle | Gas Chromatography with Dual FID/PID Detection |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Modular VOC Monitoring System |
| Detection Range | 0–300 ppb (user-selectable) |
| Detection Limit | 0.4 µg/m³ (trans-2-butene) |
| Repeatability | <3% RSD at 10 ppb (trans-2-butene) |
| Analysis Cycle | 30 minutes |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–95% RH |
| Power Supply | 220 VAC ±10% |
| Carrier Gas Flow Control | MFC (0–10 mL/min) |
| Preconcentrator Thermal Desorption Time | <10 s |
| Calibration | 5-point manual + automated sensitivity verification |
| Data Interface | Analog (4–20 mA) and digital (RS-485, Modbus TCP) compliant |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LDM-100 |
| Instrument Type | In-Situ Optical Transmissometer for Particulate Emissions Monitoring |
| Extinction Accuracy | ±0.004 |
| Repeatability | ≤2% |
| Response Time | 1–600 s (configurable) |
| Stability | Transmittance/Turbidity ±1% |
| Compliance | Meets GB/T 16157, HJ 76–2017, and HJ 836–2017 requirements for fixed-source emission monitoring |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | LGA-4500IC |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | In-Situ Online Analyzer |
| Technology | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Explosion Protection | Ex d IIB T4 Gb certified |
| Mounting | Flanged in-situ probe configuration |
| Compliance | Designed for industrial process environments per IEC 60079-0/-1/-28 and GB 3836 series |
| Target Gases | CO, CO₂, CH₄, NH₃, HCl, HF, O₂ (configurable via wavelength selection) |
| Operating Ambient Temperature | −20 °C to +60 °C |
| Process Temperature Range | Up to 1800 °C (probe-dependent) |
| Dust Load Tolerance | ≤100 g/m³ |
| Corrosion Resistance | Hastelloy C-276 probe housing standard |
| Power Supply | 24 VDC ±10% or 220 VAC 50/60 Hz |
| Output Interfaces | 4–20 mA analog, RS485 Modbus RTU, Ethernet TCP/IP, optional PROFIBUS DP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Methane / NMHC Online Analyzer |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Thermal Design | Full-Stream 175 °C High-Temperature Heating |
| Column Configuration | Dual-Valve Dual-Column (Model 115) / Dual-Valve Triple-Column (Model 120) |
| Analysis Cycle Time | <90 s per cycle |
| Target Analytes | CH₄, Total NMHC, Benzene, Toluene, Xylenes (BTX) |
| Safety Feature | Auto-H₂ shutoff upon FID flameout |
| Compliance Basis | Aligned with HJ 38–2017, HJ 1012–2018, EPA Method 25A, ASTM D6420 |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Ambient Air VOCs & Hydrocarbon Monitoring System |
| Measurement Principle | Dual-Channel GC-FID with Valve-Switched Cut-and-Backflush Separation |
| Detection Method | Flame Ionization Detection (FID) |
| Analyte Specificity | CH₄ and Total NMHC (C₂–C₁₂ hydrocarbons) |
| Carrier Gas | High-Purity Nitrogen or Helium |
| Hydrogen Fuel Gas | Ultra-High-Purity H₂ (99.999%) |
| Air for Combustion | Clean, Oil-Free Compressed Air |
| Flow Control | Electronic Pressure Control (EPC) and Electronic Flow Control (EFC) for Carrier, H₂, and Air |
| Safety Protocol | Auto-H₂-Shutoff upon Flame-Out Detection |
| Sample Introduction | Integrated Diaphragm Vacuum Pump with 1/8" PTFE-Lined Sampling Line |
| Quantitation Mode | External Standard Calibration with Certified Gas Mixtures |
| Data Output | RS485, Modbus TCP, 4–20 mA Analog Outputs |
| Environmental Operating Range | 5–40 °C, 20–90 % RH (non-condensing) |
| Power Supply | 220 VAC ±10 %, 50/60 Hz, 800 W Max |
| Enclosure Rating | IP54 Industrial Cabinet |
| Compliance | Meets CNEMC Guideline HJ 1012–2018, ASTM D6348–20, ISO 12010:2012 (for FID-based hydrocarbon analysis), GLP-Ready Data Logging |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Original Equipment Manufacturer) |
| Instrument Type | Online Aerosol Organic Carbon/Elemental Carbon Analyzer |
| Measurement Principle | Thermal-Optical Transmittance (TOT) or Thermal-Optical Reflectance (TOR) |
| Compliance | Designed for ASTM D7520, IMPROVE_A, NIOSH 5040-compatible protocols |
| Sample Inlet | Standard PM2.5 or PM10 inlet with heated line (optional) |
| Detection Method | Laser transmittance/reflectance monitoring during thermal desorption |
| Flow Control | Proportional solenoid valves + mass flow controllers (MFCs) |
| Furnace Construction | High-purity alumina ceramic furnace bricks with ceramic fiber-insulated heating elements |
| OC/EC Split Point Determination | Automated optical carbon charring correction algorithm |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | OCEC-100 |
| Instrument Principle | Thermal-Optical Transmission/Reflection (TOT/TOR) |
| Configuration | Continuous Online Monitoring System |
| Compliance | Designed for ASTM D7520, IMPROVE_A, NIOSH 5040, EUSAAR-2 protocol alignment |
| Data Output | Real-time OC/EC mass concentration (µg/m³), split point identification, charring correction trace |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Online Analyzer |
| Optical Configuration | Dual-Station Open-Path FTIR |
| Spectral Resolution | 1 cm⁻¹ |
| Detector Operating Temperature | −196 °C (Liquid Nitrogen Cooled MCT) |
| Detection Limit | Sub-ppb for Selected Analytes |
| Spectral Library | >300 Reference Spectra (Validated Against Bruker and Anhui Institute of Optics and Fine Mechanics Libraries) |
| Gas Coverage | ≥20 Target Species Including VOCs, CO, CO₂, NH₃, SO₂, NO, HCl, HF, CH₄ (Customizable) |
| Sample Handling | Direct Ambient Air Measurement — No Pre-concentration, No Chemical Derivatization, No Sampling Line Required |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Continuous Emission Monitor |
| Detection Principle | Dual-Detector Gas Chromatography (GC-PID/GC-FID) |
| Sample Introduction | Stepper Motor-Driven Piston Sampling System with Temperature/Pressure Compensation |
| Preconcentration | Integrated Tenax TA or Cryo-Focused Trap with Thermal Desorption |
| Separation Architecture | Two-Dimensional GC (2D-GC) with Primary Pre-Separation Column and Analytical Capillary Column |
| Detector Configuration | Photoionization Detector (PID) + Flame Ionization Detector (FID) |
| Data Acquisition & Control | Embedded Industrial PC with Real-Time OS |
| Communication Interfaces | Ethernet, RS-232 (COM), USB, 4–20 mA Analog Output, Digital I/O |
| Compliance Support | Designed for EPA TO-15 / TO-17 alignment, compatible with ISO 8573-6 (hydrocarbon analysis in ambient air), supports audit-ready data logging per GLP/GMP principles |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Model | PFS-100 |
| Type | Online Multicomponent Photolysis Rate Analyzer |
| Measurement Principle | Actinic Flux-Based Spectral Radiometry |
| Optical Path | Quartz Collector + UV-VIS Optical Fiber Coupling |
| Detector | Thermoelectrically Cooled CCD Array |
| Spectral Range | 280–450 nm (configurable) |
| Spectral Resolution | ≤0.5 nm (FWHM) |
| Calibration Traceability | NIST-traceable actinic flux calibration |
| Data Output | Real-time J-value time series (s⁻¹) for O¹D, NO₂, OH, HONO, HCHO, and other photolabile species |
| Compliance | Designed per ISO 17025 laboratory practice guidelines |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PMS-200 |
| Configuration | Dual-Channel Integrated Sampler |
| Flow Rate | Single-Channel: 16.67 L/min |
| Dual-Channel | 15 L/min (PM₂.₅) and 16.67 L/min (PM₁₀–PM₂.₅) |
| Vacuum Pressure Range | 80–106 kPa |
| Flow Stability | ≤2% of setpoint over 24 h |
| Maximum Flow Accuracy | ±2% of setpoint |
| Continuous Operation at Max Flow & Backpressure | 24 h |
| Service Life Under Max Load & Resistance | 2–3 years |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PMS-200A |
| Configuration | Integrated Low-Flow PM Sampler |
| Nominal Flow Rate | 16.67 L/min |
| PM10 & PM2.5 Fractionation | Equipped with ISO/EPA-compliant impactor or cyclonic PM2.5 separator |
| Filter Capacity | 16 pre-loaded filters per cassette |
| Automation | Pneumatically actuated filter exchange |
| Environmental Operating Range | -30 °C to +50 °C with active thermal regulation |
| Data Interface | RS-232, USB, and GPRS telemetry |
| Compliance | Designed to meet EPA Reference Method EQPM-0899-004, ISO 23270:2023 (Ambient air — Measurement of mass concentration of PM2.5 and PM10), and Chinese HJ 93-2013 technical specifications |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PMS-200M |
| Instrument Type | 24-Hour Temperature- and Flow-Controlled Ambient Air Sampler |
| Instrument Architecture | Multi-Channel Sequential Gas & Aerosol Sampler |
| Flow Range | Customizable (Typical Standard Range: 16.7–100 L/min per Channel) |
| Pressure Drop Handling | Up to 25 kPa (at max flow) |
| Flow Stability | ±2% over 24 h (with active feedback control) |
| Flowmeter Accuracy | ±1.5% of reading (NIST-traceable thermal mass flow sensors) |
| Rated Service Life at Max Load | ≥12,000 operating hours |
| Continuous Operation Duration at Max Flow & Backpressure | ≥24 h per cycle |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Pre-3000 + 315 VOC Online Analyzer |
| Product Category | Atmospheric VOC Online Monitoring System |
| Measurement Principle | Cryogenic Preconcentration Coupled with Capillary Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Detection Target | C2–C12 Volatile Organic Compounds (VOCs), including alcohols, ketones, esters, halogenated hydrocarbons, and aromatic compounds |
| Typical Detection Limit | Sub-ppbv (dependent on compound, integration time, and system configuration) |
| Water Removal Efficiency | >99% at −100 °C |
| Cryogenic Temperature Range | −100 °C to ambient |
| Thermal Desorption Rate | >40 °C/s (direct-resistive heating) |
| Carrier Gas Control | Electronic Pressure Control (EPC) and Electronic Flow Control (EFC) for H₂, air, and carrier gas (N₂ or He) |
| Enclosure | 19-inch rack-mount industrial chassis (standard 4U height) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | RC-1000/2000 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | SG-100 |
| Pricing | Available Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TOFMS-100 |
| Detection Principle | Single-Photon Ionization Time-of-Flight Mass Spectrometry (SPI-TOFMS) |
| Instrument Type | Continuous Online Analyzer |
| Configuration | Integrated VOC Monitoring System with GIS-enabled Mobile Deployment Capability |
| Detection Range | 0.1 ppb – 1000 ppm (v/v) |
| Mass Resolution | >800 (FWHM at m/z 92) |
| Accuracy | < ±1% Full Scale (0–500 ppb) |
| Response Time | ≤1 s (T90) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WAGA |
| Configuration | Online Continuous Monitoring System |
| Measurement Principle | Wet-Chemical Extraction Coupled with Ion Chromatography (IC) |
| Instrument Type | Online Multicomponent Aerosol Ion Analyzer |
| Compliance | Designed for ambient air quality monitoring per Chinese HJ 653–2013 and compatible with ISO 12884, EN 14902, and US EPA OTM-33A method frameworks |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WPR-Series |
| Laser Source | Not applicable (UHF/VHF passive radar principle) |
| Detector | Coherent pulsed Doppler receiver with 16-bit A/D sampling |
| Operating Frequency Band | UHF (915 MHz) or VHF (50 MHz typical, configurable) |
| Maximum Detection Altitude | Up to 12 km (dependent on frequency band and atmospheric conditions) |
| Pulse Repetition Frequency (PRF) | Configurable, typically 100–2,000 Hz |
| Measurement Parameters | Horizontal wind vector (u/v), vertical velocity (w), virtual temperature gradient, refractivity structure parameter (Cn²) |
| Compliance | Designed per MIL-STD-810G environmental ruggedization |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | FLV 600 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Configuration | Multi-component VOCs Analyzer |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GA-S |
| Pricing | Upon Request |
| Brand | GAINWAY |
|---|---|
| Model | GW-2081 |
| Origin | Hubei, China |
| Instrument Type | Online CEMS |
| Detection Target | Multi-component gases (CO₂, CH₄, N₂O, CO, O₂) |
| Measurement Ranges | 0–50 ppm (N₂O), 0–1000 ppm (CH₄), 0–20% (CO₂) |
| Response Time | <60 s |
| Flow Rate | 800 mL/min (standard), up to 3000 mL/min (dust-free) |
| Operating Temperature | 15–35 °C |
| Dimensions | 800 mm × 850 mm × 2000 mm (L×W×H) |
| Weight | 125 kg |
| Max Power Consumption | 1200 W |
| Zero Drift (24 h) | ≤0.10% FS (CO₂), ≤1 ppm (CH₄), ≤0.2 ppm (N₂O) |
| Span Drift (24 h) | ±1% FS |
| Flow Velocity Range | 0–40 m/s |
| Temperature Range | 0–300 °C |
| Humidity Range | 0–40% RH |
| Detection Principle | Gas Filter Correlation (GFC) + Long-Path Absorption Cell (L-Cell) for CH₄/N₂O |
| Brand | Galvanic |
|---|---|
| Origin | Canada |
| Model | 903W |
| Instrument Type | Online Gas Analyzer |
| Target Gas | Hydrogen Sulfide (H₂S) |
| Response Time (T₉₀) | < 20 s |
| Measurement Accuracy | ±10 ppb (LOD) |
| Measurement Range | 0–2000 ppm (undiluted) |
| Linearity | ±1% FS |
| Repeatability | ±1% FS (>1 ppm), ±2.5% FS (<1 ppm) |
| Operating Temperature | 10–50 °C |
| Power Input | 90–240 VAC / 10–36 VDC |
| Certifications | CSA C/US, Class I, Div 2, Groups B, C, D, T3 |