Gas Detector
Filter
Showing 211–240 of 1055 results
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AMS Flue Gas Heavy Metal Sampler |
| Instrument Type | Particulate and Heavy Metal Sampling System |
| Target Analytes | Heavy Metals (e.g., Pb, Cd, Hg, As, Ni, Cr) |
| Flow Accuracy | ±2% |
| Compliance Standard | UNI-EN 14385 |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS Flue Gas Particulate Sampling System |
| Instrument Type | Isokinetic Particulate Sampler |
| Flow Accuracy | ±2% |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Dioxin |
| Instrument Type | Flue Gas Dioxin Sampling System |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 1948:2006 |
| Sampling Methods | Filter-Condensation, Dilution, Cooled Probe |
| Primary Adsorbent | XAD-2 Resin or PUF Foam |
| Heating Zone Temperature | <125 °C (maintained above gas dew point) |
| Condenser Outlet Temperature | <20 °C |
| Main Flow Rate | 3–5 m³/h |
| Side Stream Flow Rate | 0.5–0.7 m³/h |
| Side-to-Main Flow Ratio Tolerance | ±10% |
| Linear Velocity in XAD-2 Tube | ≤34 cm/s |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GVP |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 0–2 L/min |
| Operating Pressure | Ambient Atmospheric Pressure |
| Flow Stability | <2% over 1 h |
| Flowmeter Accuracy | ±2% FS |
| Service Life at Max Flow & Backpressure | >1000 h |
| Continuous Run Time at Max Flow & Backpressure | >2 h |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS HCl Flue Gas Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Flow Accuracy | ±2% |
| Compliance | EN 1911, ISO 9096:1992 |
| Operating Probe Temperature | ≥120 °C (≥20 °C above HCl acid dew point) |
| Filter Efficiency | >99.5% (glass fiber or quartz fiber) |
| Sample Transit Time | <5 s (nozzle to impinger) |
| Main Stream Flow Rate | 30–150 L/min (isokinetic mode) |
| Impinger Flow Rate | 2–3 L/min |
| Typical Sampling Volume | 50–200 L (for [HCl] = 1–10 mg/m³ |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Mercury Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Target Analyte | Mercury (Hg) and Other Heavy Metals |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 13211 |
| Sample Path Material | Borosilicate Glass & Inert Heated Components |
| Probe Operating Temperature | ≥120 °C (≥20 °C above acid dew point) |
| Max. Sample Residence Time | <5 s (from probe inlet to impinger train) |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | Stack Gas2001 (600/ISS1400K) |
| Instrument Type | Heated Flue Gas Sampling Probe |
| Flow Accuracy | ±2% of full scale |
| Probe Length Options | 350 mm / 750 mm |
| Heating Element | Integrated, temperature-controlled |
| Filter | In-probe heated particulate filter (ceramic or sintered metal, typical operating temp: 180–200 °C) |
| Power Supply | Internal 14 Ah sealed lead-acid battery (rechargeable, designed for ≥500 cycles) |
| Sampling Line Assembly | Dual-layer polyethylene tubing (1.25 m length), integrated cooling jacket + electronic control unit (P/N 2100152) |
| Optional Integration | Compatible with DiluGas™ dynamic dilution system (dual-input interface) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ASP-BB02-Y1101 |
| Instrument Type | Portable |
| Detection Target | Single Gas (CO₂) |
| Range | 0–5 %vol (0–50,000 ppm) |
| Resolution | 0.01 %vol |
| Repeatability | ±1 % of reading |
| Zero Drift | ±1 % FS/month |
| Span Drift | ±2 % FS/month |
| Linearity Error | ±2 % FS |
| Response Time (T90) | <60 s |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| EMC Compliance | 2004/108/EC |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida O₂ |
| Instrument Type | Portable |
| Measurement Range | 0.1–25% O₂ (v/v) |
| Accuracy | ±0.0075% O₂ |
| Resolution | 0.1% O₂ |
| Repeatability | ±1% of reading |
| Zero Drift | <1% O₂ per month |
| Span Drift | <1% O₂ per month |
| Linearity Error | ±1% of full scale |
| Visual Indication | Green (normal), Amber (fault), Triple Red (alarm) |
| Audible Alarm | 95 dB @ 30 cm |
| Emergency Alarm | 110 dB @ 30 cm |
| Vibration Alert | Yes |
| T90 Response Time | <30 s |
| Operating Temperature | −5 °C to +50 °C |
| IP Rating | IP65 |
| Dimensions | 127 mm × 44 mm × 90 mm |
| Weight | 355 g |
| Power | Dual-mode — rechargeable Li-ion battery or two AA alkaline cells |
| Data Logging | Time-weighted average (TWA), STEL, peak hold |
| Compliance | ATEX II 2G Ex ib IIC T4 Gb, IECEx Ex ib IIC T4 Gb, UKCA, CE |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida O2 |
| Instrument Type | Portable |
| Sensor Range | 0.1–25% O₂ |
| Accuracy | ±0.0075% O₂ |
| Visual Alarm Indicators | 1× green (normal), 1× amber (fault), 3× red (alarm) |
| Audible Alarm | 95 dB @ 30 cm |
| Emergency Alarm | 110 dB @ 30 cm |
| Response Time (T90) | <30 s |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| Dimensions | 127 × 44 × 90 mm |
| Weight | 355 g |
| Power | Dual-mode — rechargeable Li-ion battery or two standard AA alkaline cells |
| TWA Calculation | Yes |
| Vibration Alert | Yes |
| Multi-user Support | Up to 2 users with individual calibration & usage logs |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | ASPIDA |
| Instrument Type | Portable |
| Detection Target | Single-component (CO₂) |
| Measurement Range | 0.01–5.00% vol CO₂ |
| Resolution | 0.01% vol |
| Accuracy | ±2% FS (0.01–2.5% range), ±3% FS (2.5–5.0% range) |
| Response Time (T90) | <60 s |
| Zero Drift | <±1% FS/6 months |
| Span Drift | <±1% FS/6 months |
| Linearity Error | ≤1% FS |
| Operating Temperature | –5 to +50 °C |
| Battery | 2×2100 mAh NiMH AA |
| Runtime | >12 h per charge |
| Charging Time | 4.5 h |
| Display | High-visibility OLED |
| Audible Alarm | 95 dB @ 30 cm (110 dB for fall detection) |
| Visual Indicators | 1 green LED (normal), 1 yellow LED (fault), 3 red LEDs (alarm) |
| Sensor Technology | Non-dispersive infrared (NDIR), MIR-based |
| CO₂ Sensor Lifetime | 5 years |
| Optional O₂ Sensor | Electrochemical, 0.1–25.0% vol, T90 <30 s, lifetime 2 years |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | ASPIDA |
| Instrument Type | Portable |
| Detection Target | Single-Gas (CO₂) |
| Measurement Range | 0.01–5.00% vol CO₂ |
| Resolution | 0.01% vol |
| Accuracy | ±2% FS (0.01–2.5% range), ±3% FS (2.5–5.0% range) |
| Response Time (T90) | <60 s |
| Zero Drift | ±1% FS/6 months |
| Span Drift | ±1% FS/6 months |
| Linearity Error | ±1% FS |
| Operating Temperature | –5 to +50 °C |
| Battery | 2 × 2100 mAh NiMH AA |
| Runtime | >12 h (continuous) |
| Charging Time | 4.5 h |
| Display | High-visibility OLED |
| Alarm | 95 dB @ 30 cm (audible), tri-color LED indicators, fall detection alarm (110 dB) |
| Sensor Technology | Non-dispersive infrared (NDIR), MIR-based |
| CO₂ Sensor Lifetime | 5 years |
| Optional O₂ Sensor | Electrochemical, 0.1–25.0% vol, T90 <30 s, 2-year lifetime |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida |
| Instrument Type | Portable |
| Detection Target | Single-Gas (CO₂) |
| Measurement Range | 0.01–5% vol CO₂ |
| Repeatability | ±2% FS (0.01–2.5% vol), ±3% FS (2.5–5% vol) |
| Resolution | 0.01% vol |
| Response Time (T90) | 20 s |
| Zero Drift | ≤±5% FS |
| Span Drift | ≤±1% FS |
| Linearity Error | ≤±2% FS |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| EMC Compliance | 2004/108/EC |
| Battery Life | 12 h (fully charged or with two AA alkaline batteries) |
| Acoustic Alarm | 95 dB @ 30 cm |
| Man-Down/Emergency Alarm | 110 dB @ 30 cm |
| Visual Indication | Tri-color LED status (green/yellow/red) |
| Display | High-contrast OLED |
| Data Logging | Internal storage with PC export capability |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida |
| Instrument Type | Portable |
| Detection Target | Single-Gas (CO₂) |
| Measurement Range | 0.01–5% vol CO₂ |
| Repeatability | ±2% FS (0.01–2.5% vol), ±3% FS (2.5–5% vol) |
| Resolution | 0.01% vol |
| Response Time (T90) | 20 s |
| Zero Drift | ≤±5% FS |
| Span Drift | ≤±1% FS |
| Linearity Error | ≤±2% FS |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| EMC Compliance | 2004/108/EC |
| Battery Life | 12 h (fully charged or with two AA batteries) |
| Audible Alarm | 95 dB @ 30 cm |
| Man-Down / Emergency Alarm | 110 dB @ 30 cm |
| Visual Indicators | Green (OK), Yellow (Fault), Triple Red (Alarm) |
| Alarm Configuration | Three user-set CO₂ concentration thresholds + one TWA alarm |
| Brand | ANALOX |
|---|---|
| Origin | United Kingdom |
| Model | HYP-MO2HBYY03 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Clark-type pO₂ sensor) |
| Range | 0–2 bar ppO₂ |
| Accuracy | ±1% of reading ±1 LSD |
| Temperature Effect | ±0.2% of reading / °C |
| Long-term Drift | ≤5% of reading per year |
| Zero Drift | <1% FS/year |
| Span Drift | <1% FS/year |
| Linearity Error | ±1% FS |
| Resolution | 0.01 bar ppO₂ |
| Repeatability | ±1% FS |
| Operating Temperature | 0–40 °C |
| Operating Pressure | 0.8–60 bar absolute (≈600 msw / 2000 fsw) |
| Compression/Decompression Rate Limit | <2 bar/min |
| Power Supply | 9 V PP3 battery |
| Battery Life | 800 h continuous operation |
| Dimensions | 64 × 98 × 36 mm |
| Weight | 0.200 kg |
| Sensor Module | Analox 9100-9212-5H |
| Optional Probe | 9100-9212-2 |
| Brand | ANALOX |
|---|---|
| Origin | United Kingdom |
| Model | HYP-MO2HBYY03 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Clark-type pO₂ sensor) |
| Range | 0–2 bar ppO₂ |
| Accuracy | ±1% of reading ±1 LSD |
| Temperature Effect | ±0.2% of reading / °C |
| Long-term Drift | ≤5% of reading per year |
| Zero Drift | <1% FS/year |
| Span Drift | <1% FS/year |
| Linearity Error | ±1% FS |
| Resolution | 0.01 bar ppO₂ |
| Repeatability | ±1% FS |
| Operating Temperature | 0–40 °C |
| Operating Pressure | 0.8–60 bar absolute (≈600 msw / 2000 fsw) |
| Response Time (t₉₀) | <15 s |
| Power Supply | 9 V PP3 battery |
| Battery Life | 800 h continuous operation |
| Dimensions | 64 × 98 × 36 mm |
| Weight | 0.200 kg |
| Sensor Model | Analox 9100-9212-5H |
| Optional Probe | 9100-9212-2 |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | SDA-CO2 |
| Sensor Range | 0–5000 ppm and 0–2% CO₂ |
| Accuracy | ±25 ppm or ±1% of reading (0–5000 ppm) |
| Display | Full-color graphical LCD |
| Output Options | 4–20 mA, relay, Ethernet (protocol available on request) |
| Data Logging | Optional internal memory |
| Alarm | Configurable audio/visual alerts via front panel |
| Compliance | DNV, IMCA, Lloyd’s Register, ABS, ADCI |
| Sensor Type | Dual-beam NDIR (Non-Dispersive Infrared) |
| Mounting | Rack-mountable or panel-mountable |
| Replacement Sensor | Advanced digital 5S3 NDIR sensor |
| Legacy Compatibility | Direct drop-in replacement for Analox 5001 |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | SDA-CO2 |
| Measurement Principle | Dual-Beam Non-Dispersive Infrared (NDIR) |
| Full-Scale Range | 0–5000 ppm / 0–2% CO₂ |
| Accuracy | ±25 ppm or ±1% of reading (0–5000 ppm) |
| Repeatability | ±1% of full scale |
| Resolution | 1 ppm (0–5000 ppm range) |
| Zero Drift | <±1% FS/month |
| Span Drift | <±1% FS/month |
| Linearity Error | ±1% of full scale |
| Display | High-brightness full-color TFT LCD |
| Output Options | 4–20 mA analog, relay outputs, Ethernet (Modbus TCP/IP configurable), optional data logging |
| Compliance | DNV GL OS-F101, IMCA D 018, Lloyds Register IR Class Rules, ABS Guide for Diving Systems, ADCI Consensus Standards |
| Sensor Type | Advanced digital 5S3 NDIR sensor |
| Mounting | Rack-mountable or panel-mountable |
| Enclosure Rating | IP65 front panel |
| Operating Temperature | 0–45 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Ankersmid |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Ankersmid |
| Price Range | USD 1,400 – 7,000 (est.) |
| Instrument Type | Continuous Emission Monitoring System (CEMS) Preconditioning Unit |
| Measurement Accuracy | ±1% FS |
| Repeatability | ≤1% RSD |
| Response Time | ≤1 s (T90) |
| Drift Stability | ≤2% over 1 h |
| Measured Medium | Flue Gas (including CO, CO₂, SO₂, NOₓ, O₂, HCl, HF, NH₃, hydrocarbons, particulates, moisture) |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DNM-4024 |
| Mixing Method | Dynamic Flow-Based Dilution |
| Instrument Type | Constant-Volume Dilutor |
| Dilution Ratio Range | 1:1 to 3000:1 (configurable or custom-expandable) |
| Dilution Accuracy | ±0.5% of reading or ±0.1% of full scale |
| Equilibration Time | 2–30 minutes |
| Operating Temperature | 10–35 °C (recommended at 25 °C) |
| Operating Humidity | 10–90% RH (non-condensing) |
| Input Gas Channels | 2 (standard, expandable) |
| Output Flow Rate | 0–500 mL/min |
| Output Volume Range | 0–999 L |
| Flow Measurement Range | 0–1000 mL |
| Flow Accuracy | ±0.5% of reading or ±0.1% of full scale |
| Power Supply | 24 V DC, 1 A |
| Max Power Consumption | 20 W |
| Dimensions (W×D×H) | 260 × 160 × 90 mm |
| Weight | ~1 kg |
| Applicable Gases | CH₄, CO, CO₂, volatile halogenated hydrocarbons, BTEX, sulfur compounds (e.g., H₂S, methanethiol), NOₓ, and other VOCs |
| Diluent Gases | Clean air, N₂, He |
| Compliance Standards | GB/T 14678–1993, HJ 1078–2019 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DNS-4024 |
| Mixing Method | Dynamic Flow-Based Dilution |
| Instrument Type | Multi-Channel Dynamic Gas Dilutor |
| Dilution Ratio Range | 1:1 to 1000:1 (standard configuration |
| Dilution Accuracy | ±0.5% of reading or ±0.1% of full scale |
| Equilibration Time | 0.1–999 min |
| Input Channels | 2 (standard |
| Output Flow Rate | 0–5000 mL/min |
| Flow Accuracy | ±0.5% of reading or ±0.1% of full scale |
| Analytical Timing Range | 0.1–999 min |
| Max Power Consumption | 20 W |
| Dimensions | 320 × 260 × 150 mm |
| Power Supply | 24 V DC, 1 A |
| Weight | ~2 kg |
| Compatible Carrier Gases | Clean Air, N₂, He |
| Target Analytes | CH₄, CO, CO₂, VOCs (e.g., halogenated hydrocarbons, BTEX), H₂S, other sulfur compounds, NOₓ |
| Concentration Range Supported | 10 ppb – 10,000 ppm |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | THB-8021 |
| Instrument Type | Portable |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Measurement Range | 1.0–50,000 ppm (as methane or propane equivalent) |
| Detection Limit | 0.5 ppm (FID, ethane |
| Repeatability | ±2% at 100 ppm methane (FID) |
| Accuracy | ±10% of reading or ±1.0 ppm (FID, whichever is greater) |
| Response Time (FID) | ≤3.5 s to 90% of final value (10,000 ppm CH₄) |
| Recovery Time (FID) | ≤4.5 s to within 10% of baseline (10,000 ppm CH₄) |
| Dynamic & Linear Range (FID) | 1.0–50,000 ppm |
| Detector Lifetime (FID) | >5,000 h (with routine maintenance) |
| Power Supply | Internal rechargeable battery (10 h operation, 4 h charge) |
| Dimensions | 219 × 260 × 70 mm |
| Weight | 4.1 kg |
| Operating Temperature | −10 to +50 °C |
| Data Output | USB (TXT format), Bluetooth, optional 4G/GPS |
| Intrinsic Safety | Certified for Class I, Division 1 hazardous areas (per IECEx/ATEX standards) |
| Compliance | Designed to support LDAR (Leak Detection and Repair) programs per US EPA Method 21, ASTM D6420, and ISO 16000-29 |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Model | AGA800 |
| Measurement Principle | Ultraviolet Differential Optical Absorption Spectroscopy (UV-DOAS) |
| Installation Type | In-situ probe-mounted |
| Response Time | ≤8 s |
| Operating Temperature (Probe) | Up to 400 °C (heated optical path) |
| Target Gases | SO₂, NO, NO₂ (total NOₓ) |
| Calibration | Automated in-situ optical zero/span correction |
| Compliance Context | Designed for continuous emission monitoring systems (CEMS) per HJ 75-2017 & HJ 76-2017 (China), compatible with ISO 12039, EN 15267, and EPA Method 6C/7E requirements |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ARX-C200 / ARX-G310 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±2% of Full Scale (F.S.) |
| Response Time | ≤ 200 s |
| Measured Parameters | SO₂, NO, NO₂, O₂, Particulate Matter (PM), Flue Gas Temperature, Static Pressure, Flow Velocity, Relative Humidity |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ARX-C200H |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±2% F.S. |
| Response Time | ≤120 s |
| Measured Parameters | SO₂, NO, NO₂, O₂, NH₃, Particulate Matter (PM), Temperature, Pressure, Flue Gas Velocity, Relative Humidity |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ARX-MA100 |
| Measurement Principle | Optical Scattering (for Particulates), Electrochemical (for SO₂/NO₂/CO/O₃), Photoionization Detection (PID) for TVOC |
| Measured Parameters | TSP, PM₁₀, PM₂.₅, NO₂, CO, SO₂, O₃, TVOC, Temperature, Relative Humidity, Wind Speed, Wind Direction, Atmospheric Pressure |
| Optional Gases | NH₃, H₂S |
| Sampling Pump | Brushless Vacuum Pump with Stable Flow Control |
| Sample Conditioning | Dynamic Heating System (DHS) with Real-time Temperature Feedback |
| Data Transmission | Industrial-grade Multi-protocol Module (RS485, 4G LTE, Ethernet, LoRaWAN) |
| Alarm Function | Full-range Configurable Thresholds with Dry Contact Output for Dust Suppression Integration (e.g., Fog Cannon Trigger) |
| Compliance | Designed to Support ISO 12103-1, EPA EQOA-1 Reference Methods (for comparative monitoring), and GLP-aligned data logging architecture |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Model | LFS800 |
| Measurement Principle | Laser Forward Scattering |
| Sample Type | Wet Flue Gas |
| Measured Parameter | Particulate Matter (PM) |
| Range | 0–5 mg/m³ (Low Range), Dual-Range Auto-Switching |
| Detection Limit | 0.01 mg/m³ |
| Accuracy | ±10% (Gravimetric Reference Method) |
| Isokinetic Sampling Flow Rate | Up to 200 L/min |
| Heating | Full-Path Heated Sampling Line |
| Calibration | Automated Zero and Span Calibration |
| Display | Integrated LED Interface |
| Output | Analog 4–20 mA + Digital RS485/Modbus RTU |
| Compliance | Designed for China’s HJ 75–2017 & HJ 76–2017 CEMS Technical Specifications |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Model | LSS2014 |
| Measurement Principle | Laser Backscatter (90°–180° detection geometry) |
| Measurand | Particulate Matter (PM) in Flue Gas |
| Range | 0–20 mg/m³ (Ultra-Low Mode), Dual-Range Operation Supported |
| LOD | 0.05 mg/m³ |
| Installation Type | In-Situ, Non-Extractive |
| Gas Condition Requirement | Dry, Non-Condensing Flue Gas |
| Compliance Context | Designed for continuous emission monitoring systems (CEMS) per Chinese HJ 76-2017 and compatible with international flue gas monitoring frameworks (e.g., EN 15267, ISO 12141, US EPA Method 9 and Performance Specification PS-11) |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Model | MB11 |
| Instrument Type | Online Gas Analyzer |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Optical Technique | High-Frequency Scanned Wavelength Modulation Spectroscopy with Dual-Wavelength Differential Compensation |
| Operating Environment | High-Temperature In-Situ or Extractive Sampling |
| Sample Handling | Heated Probe + Heated Sample Line (up to 200 °C) |
| Interference Resistance | Immune to H₂O, CO₂, SO₂, NOₓ, and Particulate Obscuration |
| Output Interfaces | 4–20 mA Analog, RS485 Modbus RTU, Relay Status Outputs, Optional Integrated Humidity Sensor |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Model | MB22-NH3 |
| Type | Online Gas Analyzer |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sample Path Temperature | Fully Heated to ≥180 °C (Adjustable) |
| Detection Limit | Sub-ppm Range (Typical LOD < 0.5 ppmv) |
| Response Time (T90) | < 10 s |
| Optical Path | Multi-Pass Herriott Cell with Pressure Compensation |
| Wavelength Stabilization | Integrated Reference Gas Cell |
| Calibration | Full-Path Zero/ Span Auto-Calibration |
| Environmental Rating | IP65 Enclosure |
| Operating Temperature | −20 °C to +50 °C |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Output Interfaces | 4–20 mA, RS485, Modbus TCP, Optional Ethernet/Profibus |