| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | KLDC50-1 |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Hollow Fiber Membrane Separation |
| Output Flow Rate | 50 L/min |
| Output Pressure Range | 0–5 bar |
| Nitrogen Purity | 99.9% |
| Noise Level | <55 dB(A) |
| Filtration Stages | 3-stage (water, oil, particulates) |
| Particulate Removal Efficiency | ≥99.999% at 0.01 µm |
| Hydrocarbon Content | <0.1 ppm |
| Dew Point | ≤−40 °C |
| Power Supply | 220 V AC, 50 Hz |
| Dimensions (W×D×H) | 560 × 520 × 820 mm |
| Weight | ~72 kg |
| Compressor Type | Oil-free scroll air compressor |
| Integrated Buffer Tank Capacity | 12 L |
| Auto-standby Function | Yes |
| Energy Savings Mode | Yes (up to 30% reduction in power consumption vs. conventional continuous-run systems) |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | KLIC-1 |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Hollow Fiber Membrane Separation |
| Output Flow Rate | 2 L/min |
| Output Pressure Range | 0–6 bar |
| Nitrogen Purity | ≥99.9% |
| Hydrocarbon Content | ≤0.1 ppm |
| Acidic Gas Removal Efficiency (SO₂/H₂S/HF) | >99% |
| Operating Noise Level | <60 dB(A) |
| Flow Stability (Pulsation Error) | <0.5% |
| Design | Integrated Compact Module with Built-in Buffer Tank and Oil-Free Air Compressor |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 0–160 L/min |
| Output Pressure | 0–7 bar |
| Nitrogen Purity | 99.9% |
| Design Architecture | Split-System (Requires External Air Compressor) |
| Control Interface | Touchscreen LCD with Real-Time Monitoring |
| Connectivity | IoT-Enabled Remote Monitoring & Management |
| Operational Duty Cycle | Continuous 24/7 Operation |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| compatible with ASTM D857 and ISO 8573-1 | 2010 Class 2 compressed air input requirements |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | N2 Haloes |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) using Carbon Molecular Sieves |
| Output Flow Rate | Up to 50 L/min (typical configuration) |
| Purity | 99.5%–99.9995% (adjustable per application requirement) |
| Outlet Pressure | 0–7 bar (g) adjustable |
| Dew Point | ≤ –40 °C (standard), optional down to –70 °C |
| Power Supply | 220 V AC, 50/60 Hz |
| Ambient Operating Temperature | 5–35 °C |
| Noise Level | < 60 dB(A) |
| Compliance | CE-marked, ISO 8573-1 Class 2:2:2 (compressed air feed required), compatible with GLP/GMP environments |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | On-Site Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 0–240 L/min |
| Output Pressure | 0–7 bar(g) |
| Nitrogen Purity | 99.9% |
| Control Interface | Touchscreen LCD with Real-Time Monitoring |
| Remote Management | IoT-Enabled Cloud Connectivity |
| Structural Design | Split-System (Requires External Air Compressor) |
| Duty Cycle | Continuous 24/7 Operation |
| Compliance | Designed for GLP/GMP-Compliant Laboratories |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | On-Site Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 0–320 L/min |
| Output Pressure | 0–7 bar(g) |
| Nitrogen Purity | 99.9% |
| Control Interface | Touchscreen LCD with Real-Time Monitoring |
| Remote Management | IoT-Enabled Cloud Connectivity |
| Structural Design | Split-System (Air Compressor Not Included) |
| Duty Cycle | Continuous 24/7 Operation |
| Compliance | Designed for GLP/GMP-Compliant Laboratories |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | i-Lab Technology Co., Ltd. |
| Model | N45-1Pro |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with dual-tower configuration and imported high-efficiency carbon molecular sieve (CMS) |
| Output Flow Rate | 45 L/min |
| Output Pressure Range | 0–8 bar |
| Nitrogen Purity | 99.9% |
| Noise Level | <60 dB(A) |
| CMS Surface Area | BET >800 m²/g |
| Tower Switching Accuracy | <0.1 s |
| Power Consumption Reduction (ECO Mode) | 15% |
| CMS Service Life | 5–8 years |
| Flow Stability Error | ≤±2% |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | i-Lab Technology Co., Ltd. |
| Model | N60-1Pro |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with dual-tower configuration and imported high-efficiency carbon molecular sieve (CMS) columns |
| Output Flow Rate | 60 L/min |
| Output Pressure Range | 0–8 bar |
| Nitrogen Purity | 99.9% (up to 99.95% under optimized conditions) |
| Noise Level | <60 dB(A) |
| CMS Surface Area | BET >800 m²/g |
| Tower Switching Accuracy | <0.1 s |
| Power Consumption Reduction (ECO Mode) | 15% |
| CMS Service Life | 5–8 years |
| Flow Stability Error | ≤±2% |
| Modular Design | Yes |
| IoT Connectivity | Yes |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| compatible with ASTM D6349, ISO 8573-1 Class 2 | 2:2 (for particle, water, oil), and FDA 21 CFR Part 11-ready data logging (via optional software module) |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 75 L/min |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | 99.9% |
| Integrated Buffer Tank Capacity | 25 L |
| Operating Mode | Continuous 24/7 Unattended Operation |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Interface | Touchscreen LCD with real-time pressure, flow, and status monitoring |
| Structural Design | Split-system (requires external air compressor) |
| Mobility | Heavy-duty swivel casters rated for high-pressure lab environments |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UHAN1-1 |
| Gas Purity | 99.99996% (N₂), Zero Air (HC < 0.1 ppm, CO < 0.1 ppm, NOₓ < 0.1 ppm, SO₂ < 0.1 ppm, H₂O < 1 ppm) |
| Output Flow Rate | 1.2 L/min (combined or individually configurable) |
| Output Pressure Range | 0–7 bar (adjustable and pressure-stabilized) |
| Design | Integrated Monoblock Architecture |
| Control Interface | Intelligent Full-Color Touchscreen with Embedded IoT Module |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | UHAN2-1 |
| Gas Purity | 99.99996% (N₂) |
| Nitrogen Output Flow | 2 L/min |
| Output Pressure Range | 0–7 bar |
| Design | Integrated Monoblock Architecture |
| Control Interface | Intelligent Touchscreen HMI |
| Noise Level | <45 dB(A) |
| Core Technology | Imported PSA Molecular Sieve Modules + Oil-Free Compressor |
| Safety Features | Overpressure Protection, Automatic Pressure Relief |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | UHAN5-1 |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieves |
| Air Output Flow | 3000 mL/min |
| Nitrogen Output Flow | 5000 mL/min |
| Nitrogen Output Pressure | 0–7 bar |
| Air Output Pressure | 0–8 bar |
| Nitrogen Purity | 99.9999% |
| Particle Filtration Efficiency | 0.01 µm |
| Noise Level | <45 dB(A) |
| Certification | ISO 9001 |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | UHN1-1 |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 1.2 L/min |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | 99.999% |
| Noise Level | <45 dB(A) |
| Control Interface | Full-color TFT touchscreen |
| Connectivity | Embedded IoT module for remote monitoring and status reporting |
| Compliance | Designed to meet ISO 8573-1 Class 1 compressed air quality requirements for nitrogen supply to analytical instruments |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UHN15-1EL |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 15 L/min |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | ≥99.99% |
| Dew Point | ≤−60 °C |
| Key Components | Imported CMS beds, high-efficiency coalescing filters, precision pressure regulators, and integrated oxygen analyzer |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 2 L/min |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | 99.999% |
| Noise Level | <45 dB(A) |
| Compliance | Designed for GC/GC-MS integration per ASTM D6346 & ISO 8573-1 Class 1 compressed air/nitrogen quality requirements |
| Safety Features | Overpressure protection, automatic pressure relief, thermal cut-off |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UHN5-1 |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 5000 mL/min |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | 99.9999% |
| Dew Point | −40 °C |
| Particulate Filtration Efficiency | 0.01 µm |
| Pressure Stability | < ±0.5% |
| Noise Level | < 45 dB(A) |
| Operating Mode | Continuous 7×24 h |
| Certification | ISO 9001 |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | UHN5-1EL |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 5 L/min |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | ≥99.999% (O₂ < 3 ppm, Dew Point ≤ −60 °C) |
| Flow Stability | ±1% |
| Pressure Fluctuation | < 0.3% |
| Noise Level | < 60 dB(A) |
| Certifications | ISO 9001, CE |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | i-Lab |
| Type | Domestic |
| Model | ZeroAir1 |
| Price | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 1 L/min |
| Output Pressure Range | 0–6 bar |
| Total Hydrocarbon Content (THC) | <0.1 ppm |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | ZeroAir10 |
| Quotation | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 10 L/min |
| Output Pressure Range | 0–6 bar |
| Total Hydrocarbon Content | < 0.1 ppm (as methane equivalent) |
| Dew Point | –60 °C |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZeroAir35 |
| Quotation | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Oxidation |
| Output Flow Rate | 35 L/min |
| Output Pressure Range | 0–6 bar (adjustable) |
| Total Hydrocarbon Content (THC) | <0.1 ppm (as methane equivalent) |
| Residual THC after dual-stage purification | <0.05 ppm |
| Particulate Filtration | 0.01 µm absolute rating |
| Noise Level | ≤55 dB(A) |
| Continuous Operation Rating | 7×24 hours |
| Rated Service Life | >30,000 operating hours |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | ZeroAir5 |
| Pricing | Available Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 5 L/min |
| Output Pressure Range | 0–6 bar |
| Total Hydrocarbon Content (THC) | <0.1 ppm |
| Brand | ibidi |
|---|---|
| Origin | Germany |
| Model | 11920 / 11922 / 11929 |
| Application | Live-cell imaging, hypoxia/anoxia studies, shear stress assays, TIRF & confocal microscopy |
| Compatibility | ibidi Heating Systems (universal & multiwell plate variants) |
| Humidification | Dynamic inline humidification column |
| Gas Delivery | Pressure-driven, vibration-free flow |
| Optional Accessory | Integrated gas compressor module |
| Brand | INNOTEG |
|---|---|
| Origin | Italy |
| Model | HP-HG250 |
| Hydrogen Generation Principle | PEM Electrolysis of Deionized Water |
| Output Flow Rate | 250 mL/min |
| Output Pressure | 11 bar |
| Hydrogen Purity | >99.9996% |
| Power Consumption | 200 W |
| Certifications | CE, FCC, MET (UL/CSA) |
| Continuous Operation | 24/7, 365 days/year |
| Safety Features | Dual Internal/External H₂ Leak Detection with Auto-Shutdown, Liquid Level Monitoring, Conductivity-Based Water Quality Monitoring |
| Optional Functions | Automatic Refill, Cascade Operation |
| Brand | INNOTEG |
|---|---|
| Origin | Italy |
| Model | Hybrid LCMS1 |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 12 L/min |
| Output Pressure | 5 bar |
| Nitrogen Purity | >98% |
| Dew Point | −40 °C |
| Certifications | CE, FCC, MET (UL/CSA) |
| Compressor Type | Integrated Oil-Free Air Compressor |
| Operating Duty Cycle | Continuous 24/7 Operation |
| Mobility | Casters for Easy Relocation |
| Safety Features | Multi-Stage Pressure Monitoring, Real-Time System Diagnostics |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TH-300 |
| Pricing | Available Upon Request |
| Hydrogen Generation Principle | Solid Polymer Electrolyte (SPE) Technology |
| Output Flow Rate | 0–300 mL/min |
| Output Pressure | 0–0.4 MPa |
| Hydrogen Purity | 99.999% |
| Power Consumption | 150 W |
| Brand | INNOTEG |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | UHP-HG250 |
| Hydrogen Generation Principle | Proton Exchange Membrane (PEM) Electrolysis of Deionized Water |
| Output Flow Rate | 250 mL/min |
| Output Pressure | 11 bar |
| Hydrogen Purity | >99.99996% (6.6 N) |
| Power Consumption | 200 W |
| Certifications | CE, FCC, MET (UL/CSA) |
| Continuous Operation | 24/7, 365 days/year |
| Optional Features | Auto-refill System, Multi-unit Cascade Control |
| Brand | JIAYUAN |
|---|---|
| Model | HA-300 |
| Hydrogen Purity | 99.999% |
| Hydrogen Flow Rate | 0–300 mL/min |
| Hydrogen Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| Air Flow Rate | 0–2000 mL/min |
| Air Pressure | 0–0.4 MPa |
| Operating Noise | <40 dB(A) |
| Ambient Humidity | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 500 × 300 × 380 mm |
| Weight | 20 kg |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HG1802 |
| Hydrogen Purity | 99.999% |
| Hydrogen Flow Rate | 0–200 mL/min |
| Flow Display | LED Digital |
| Operating Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| Pressure Stability | ±0.02 MPa |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 150 W |
| Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions (W×D×H) | 400 × 180 × 380 mm |
| Net Weight | ~12 kg |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | NA-300 |
| Nitrogen Purity | 99.999% (O₂ < 3 ppm, Dew Point: −56 °C) |
| Nitrogen Flow Rate | 0–300 mL/min |
| Nitrogen Pressure | 0–0.4 MPa |
| Air Flow Rate | 0–2000 mL/min |
| Air Pressure | 0–0.4 MPa |
| Noise Level | < 40 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Ambient Humidity | ≤85% RH |
| Dimensions (W×D×H) | 500 × 300 × 380 mm |
| Weight | 20 kg |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | NG1903 |
| Nitrogen Purity | 99.999% (O₂ < 3 ppm, Dew Point: −56 °C) |
| Flow Rate | 0–300 mL/min |
| Output Pressure | 0.4 MPa |
| Pressure Stability | ±0.003 MPa |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 150 W |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions (W×D×H) | 400 × 180 × 380 mm |
| Net Weight | 12.5 kg |