- All
- Favorite
- Popular
- Most rated
| Brand | Apkji |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AP-HX-A4 |
| Instrument Type | Benchtop |
| Condensation Method | Air-Cooled |
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 20–98 % RH |
| Temperature Uniformity | ±2.0 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Fluctuation | ±2 °C |
| Humidity Uniformity | ≤±3 % RH |
| Humidity Stability | ±2 % RH |
| Humidity Fluctuation | ±3 % RH |
| Heating Rate | 1.0–3.0 °C/min (empty chamber) |
| Internal Chamber Dimensions | 500 × 600 × 500 mm (W × H × D) |
| Internal Volume | 150 L |
| Brand | APKJ |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP-HX-B2 |
| Pricing | Available Upon Request |
| Internal Volume Options | 80 L, 150 L, 408 L, 800 L, 1000 L (custom volumes up to 100 m³ walk-in) |
| Temperature Range | –150 °C to +200 °C |
| Humidity Range | 10–98 % RH (standard: 20–98 % RH) |
| Temp. Uniformity | ±2 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Uniformity | ±2.5 % RH |
| Humidity Stability | ±3 % RH |
| Heating Rate | ≥3 °C/min (up to 5 °C/min typical) |
| Cooling Rate | ≥1 °C/min (up to 5 °C/min typical) |
| Control System | Balanced Temperature & Humidity Control (BTHC) with PID-driven SSR regulation |
| Inner Chamber Material | SUS#304 mirror-finish stainless steel |
| Outer Chamber Material | SUS#304 brushed or powder-coated stainless steel |
| Insulation | Rigid polyurethane foam + glass wool |
| Refrigeration | Hermetic French Tecumseh compressors, eco-friendly refrigerant |
| Controller | TEMI touchscreen HMI (South Korea), integrated with Italian/Danish/Japanese components |
| Safety Protections | Compressor overheat/overcurrent/overpressure, dry-run prevention for heaters/humidifiers, chamber over-temperature, low-water alarm |
| Power Supply | 3-phase 5-wire 380 VAC ±10% or 2-phase 3-wire 220 VAC ±10% |
| Brand | Apkji |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Ap-CJ-150L |
| Temperature Range Options | A-Type (−20 °C to +100 °C / +150 °C), B-Type (−40 °C to +100 °C / +150 °C), C-Type (−70 °C to +100 °C / +150 °C) |
| Temperature Uniformity | ≤ ±0.5 °C |
| Temperature Stability | ≤ 2 °C |
| Heating Rate | 1.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Internal Dimensions (W×D×H) | 700 × 600 × 600 mm |
| External Dimensions (W×D×H) | 1900 × 2000 × 1640 mm |
| Control System | Fuji Electric Intelligent LCD Temperature & Humidity Controller (AP-CJ-250 variant referenced) |
| Refrigeration | Twin-stage cascade refrigeration system with French Tecumseh hermetic compressors and multi-plate evaporators |
| Heating | Nickel-chromium alloy electric heaters |
| Air Circulation | Low-noise, high-efficiency centrifugal blower with stainless-steel impeller and adjustable multi-wing airflow ducting |
| Insulation | High-density polyurethane foam + ultra-fine glass fiber composite |
| Sensor | PT100 platinum resistance thermometer |
| Compliance | GB/T 2423.1–2008, GB/T 2423.2–2008, GB/T 2423.22–2012, GJB 150.5–1986, GJB 360.7–1987, GJB 367.2–1987, QC/T 17–1992, EIA-364-32, IEC 60068-2-14 |
| Safety Protections | Over-temperature/over-cooling cut-off, compressor high-pressure protection, leakage current interrupter, fast-acting fuse, grounding fault detection, audible alarm |
| Brand | Apkji |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | AP-HX-150A |
| Instrument Type | Benchtop |
| Condensation Method | Air-Cooled |
| Temperature Range | 0°C to 150°C |
| Humidity Range | 20%–98% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Humidity Uniformity | ≤ ±2% RH |
| Humidity Fluctuation | ±3% RH |
| Heating Rate | 1.0–3.0°C/min |
| Internal Chamber Dimensions | 500 × 600 × 500 mm (W × D × H) |
| Brand | APKJ |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | AP-HX-80L1 |
| Pricing | Upon Request |
| Brand | Apkji |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP-HX-80A |
| Pricing | Upon Request |
| Brand | Apkji |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Model | AP-HX-80C |
| Temperature Range | -70 °C to +150 °C |
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±2 °C |
| Humidity Uniformity | ±2% RH |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Fluctuation | ±2% RH |
| Heating Rate | ≥3 °C/min |
| Cooling Rate | ≥1 °C/min |
| Internal Dimensions (W×H×D) | 40×50×40 cm |
| Construction | SUS304 Stainless Steel Interior |
| Control System | TEMI880 Touchscreen Controller (English/Chinese UI) |
| Compliance | GB/T 10586, GB/T 10592, IEC 60068-2, MIL-STD-810D, GJB 150.9 |
| Brand | APKJ |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP-225L-HX |
| Pricing | Upon Request |
| Internal Volume | 225 L |
| Temperature Range | −40 °C to +150 °C (configurable) |
| Temperature Uniformity | ±2 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Humidity Range | 20–98% RH (optional) |
| Humidity Control Accuracy | ±2.5% RH |
| Heating Rate | ~3 °C/min (RT to +150 °C in ~40 min) |
| Cooling Rate | ~1 °C/min (RT to −40 °C in ~65 min) |
| Construction | Interior – Mirror-finish SUS304 stainless steel |
| Refrigeration System | Air-cooled, single-stage or cascade (R404A/R23) with hermetic compressors (Tecumseh or Bitzer) |
| Controller | Programmable PID-based microprocessor controller (standard) |
| Safety Features | Independent over-temperature cutoff, compressor overheat/overcurrent/overload protection, fan thermal protection, low-water alarm (for humidification), audible/visual alarms |
| Interface Options | RS-485, USB data export, optional printer connectivity |
| Compliance | Designed to support ISO 17025-compliant test environments |
| Brand | APKJ |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP-HX-5 |
| Pricing | Available Upon Request |
| Brand | Apkji |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP-DG-80A |
| Chamber Type | Upright |
| Temperature Range | -40°C to +150°C |
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ≤ ±0.5°C |
| Humidity Deviation | ≤ ±2.0% RH (at >75% RH) |
| Heating Rate | 1.0–3.0°C/min |
| Refrigeration System | Hermetic Rotary Compressor |
| Control Interface | 5.7-inch TFT Color LCD Touchscreen (Q8-902) |
| Programming Capacity | 269 programmable profiles, up to 50 steps per profile, 3200 cycles per step |
| Data Logging | Battery-backed RAM, 90-day storage (1-min sampling interval) |
| Compliance | Designed for ASTM D4332, ISO 4892-2, IEC 60068-2-1/2/14/30, GB/T 2423.1–2423.4 |
| Brand | Apkji (APKJ) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AP-HX80 |
| Price Range | USD 1,400–7,200 (est.) |
| Instrument Type | Benchtop |
| Humidity Range | 20–98% RH |
| Temperature Fluctuation | ±2°C |
| Humidity Deviation | ±3% RH |
| Heating Rate | 1.0–3.0°C/min |
| Temperature Range | −70°C to +100°C (optional up to +150°C) |
| Internal Dimensions (W×H×D) | 40×50×40 cm |
| External Dimensions (W×H×D) | 90×136×94 cm |
| Construction | SUS304 Stainless Steel Interior & Exterior (Sandblasted Finish) |
| Insulation | High-Density Polyurethane Foam (HCFC-Free) |
| Cooling System | Air-Cooled Single-Stage Compressor (≥−20°C) / Air-Water Cooled Dual-Stage Compressor (≤−40°C) |
| Controller | TEMI (South Korea) or OYO (Japan) Programmable Touchscreen PID Controller |
| Compressor | Tecumseh (France) |
| Power Supply | 1Φ 220VAC ±10%, 50/60 Hz or 3Φ 380VAC ±10%, 50/60 Hz |
| Standards Compliance | GB/T 2423.1–2423.4, GB/T 2423.22, GB 11158, GB 10589, GB 10592, GB/T 10586, IEC 60068-2-1 & -2-2, GJB 150.3/150.4/150.9 |
| Brand | Apkji (APKJ) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | 150AP-HX |
| Pricing | Available Upon Request |
| Temperature Range | RT+10°C to 100°C |
| Humidity Range | 20–98% RH |
| Temp. Uniformity | ±2°C |
| Temp. Stability | ±0.5°C |
| Humidity Accuracy | ±2% RH |
| Heating Rate | ~20 min (RT → 100°C) |
| Control Resolution | ±0.1°C / ±0.1% RH |
| Compliant Standards | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.3–1993 |
| Brand | Apkji (APKJ) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | 100AP-HX |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Benchtop |
| Humidity Range | 20–98% RH |
| Temperature Fluctuation | ±0.5°C |
| Humidity Deviation | ±2% RH |
| Heating Rate | 3.0°C/min |
| Brand | APKJ |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | APHX |
| Pricing | Upon Request |
| Temperature Range | RT+10°C to 100°C (standard) |
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Temperature Stability | ±0.2°C |
| Humidity Stability | ±2.5% RH |
| Heating Rate | ~3°C/min (RT to +150°C in ~40 min) |
| Cooling Rate | ~1°C/min (RT to −70°C in ~100 min) |
| Internal Volume Options | 80 L to 1000 L |
| Construction | Interior – SUS304 stainless steel |
| Control System | Imported microprocessor-based temperature & humidity controller with direct %RH display, PT100 platinum resistance sensors, ±0.1°C/±0.1% RH setpoint & indication accuracy |
| Safety Features | Independent over-temperature cutoff, dry-run protection, water shortage detection, liquid level monitoring, compressor overpressure/overheat/overcurrent protection, emergency stop, no-fuse breakers |
| Power Supply | 1φ3w AC220V ±10%, 50/60 Hz or 3φ5w AC380/415V ±10%, 50/60 Hz |
| Standard Accessories | Φ50 mm cable port with cover, 2 adjustable stainless steel shelves, 5 pieces of humidity wick cloth, interior LED lighting, full operation manual |
| Brand | Apkem |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | AP-HX |
| Price | Upon Request |
| Refrigeration System | Dual-stage cascade refrigeration (Low-temp stage: R23/R508B |
| High-temp stage | R404A/R507) |
| Compressor | Imported hermetic scroll compressor (Tecumseh France) |
| Temperature Range (Test Zone) | -40 °C to +150 °C (Standard A) |
| Optional | -55 °C / -65 °C to +150 °C |
| High-Temp Storage Zone | +60 °C to +200 °C |
| Low-Temp Storage Zone | -10 °C to -75 °C |
| Temp. Transition Time (Test Zone) | ≤10 s |
| Temperature Recovery Time (Test Zone) | ≤5 min |
| Temp. Uniformity | ±2.0 °C (measured at 1/10 distance from chamber walls) |
| Temp. Control Accuracy | ±0.5 °C |
| Compliance | GB/T 10589–1989, GB/T 10592–1989, GB/T 2423.1–1989 (Test Aa/Ab), GB/T 2423.4–1993 (Test Db), MIL-STD-810D Method 502.2 & 507.2 Proc. 3 |
| Interface | LAN + USB |
| Safety | Over-temperature, over-pressure, phase failure, refrigerant leak, and motor overload protection with auto-diagnostic display |
| Brand | Apkem |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AP-HX-150D3 |
| Instrument Type | Benchtop |
| Humidity Range | 20–98% RH |
| Temperature Fluctuation | ±2°C |
| Humidity Deviation | ±3% RH |
| Heating Rate | 1.0–3.0°C/min |
| Temperature Range | −70°C to +150°C |
| Temperature Uniformity | ≤2°C |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Control Accuracy | ±3% RH |
| Cooling Method | Air-Cooled Dual-Stage Cascade Refrigeration |
| Compressor | Tecumseh Hermetic Scroll Compressor |
| Controller | TEMI360 Programmable Touchscreen PID Controller |
| Internal Dimensions (W×D×H) | 500×600×500 mm |
| External Dimensions (W×D×H) | 1050×1700×1030 mm |
| Power Supply | AC 220V/380V, 50 Hz |
| Insulation | High-Density Polyurethane Foam + Ultra-Fine Glass Fiber |
| Interior Material | SUS304 Stainless Steel |
| Exterior Material | A3 Steel with Electrostatic Powder Coating |
| Sealing | Dual-Layer High/Low-Temperature Resistant Silicone Gasket |
| Air Circulation | Single-Cycle Forced Convection with Centrifugal Blower |
| Standard Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.4–1993, IEC 60068-2-1, IEC 60068-2-2 |
| Brand | APEKJ |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AP-HX-408 |
| Pricing | Upon Request |
| Internal Volume | 408 L |
| Internal Dimensions (W×D×H) | 60 × 85 × 80 cm |
| External Dimensions (W×D×H) | 105 × 165 × 125 cm |
| Weight | 300 kg |
| Temperature Range | RT+10°C to 100°C |
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ±0.5°C |
| Humidity Deviation | +2% / −3% RH |
| Heating Rate | ~20 min (from ambient to 100°C) |
| Control System | Imported microcomputer-based integrated temperature & humidity controller with PT100 sensors |
| Heating Method | Independent nickel-chromium alloy electric heaters |
| Humidification Method | External stainless-steel boiler-type shallow-surface evaporation system |
| Air Circulation | Low-noise, high-efficiency centrifugal blower with multi-blade impeller |
| Compliance Standards | GB/T 2423.1–2023 (IEC 60068-2-1), GB/T 2423.2–2023 (IEC 60068-2-2), GB/T 2423.3–2016 (IEC 60068-2-78), GB/T 2423.4–2016 (IEC 60068-2-30), GJB 150.3A–2009, GJB 150.4A–2009, GJB 150.9A–2009 |
| Brand | Apeike (APKJ) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Humidity Range | 20–98% RH (at 25–80°C) |
| Temperature Fluctuation | ±0.5°C |
| Humidity Deviation | ±2% RH |
| Heating Rate | 3.0°C/min |
| Cooling Rate | 0.7–1.2°C/min |
| Temperature Range Options | −70 to 150°C (configurable) |
| Control System | PID + SSR with PT100 Sensors |
| Power Supply | AC 380 V / 50 Hz |
| Compliance | GB/T 10592–2008, GB/T 2423.1–2023, GB/T 2423.2–2023, GJB 150.3A–2009, GJB 150.4A–2009, IEC 60068-2-1, MIL-STD-810H |