- All
- Favorite
- Popular
- Most rated
| Brand | APKJ |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP-HX-80 |
| Pricing | Available Upon Request |
| Internal Dimensions (D×W×H) | 1000×1000×1000 mm |
| Temperature Range | −70 °C to +150 °C |
| Temperature Uniformity | ≤2 °C (unloaded) |
| Temperature Fluctuation | ±0.5 °C (unloaded) |
| Temperature Deviation | ≤±2 °C |
| Ramp Rate | 0.7–1.0 °C/min (unloaded) |
| Timer Range | 0–9999 h |
| Control Resolution | ±0.1 °C |
| Sensor | PT100 Platinum Resistance Thermometer |
| Heating System | Nickel-Chromium Far-Infrared Heaters |
| Refrigeration System | Hermetic French Tecumseh Compressor |
| Refrigerant | R404A |
| Cooling Method | Forced-Air Condensation |
| Compliance | GB/T 2423.1–2021, GB/T 2423.2–2021, GB/T 10592–2008 |
| Brand | APKJ |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP-DW-B |
| Price Range | USD 7,000–14,000 (FOB) |
| Temperature Range | −40 °C to +150 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Heating Rate | 1–3 °C/min |
| Cooling Rate | 0.7–1 °C/min |
| Control Precision | ±0.2 °C |
| Internal Volume | 100 L (W50×H50×D40 cm) |
| Construction | SUS304 Stainless Steel Interior & Exterior |
| Insulation | Rigid Polyurethane Foam + Glass Wool |
| Refrigeration | Single-Stage or Cascade System with HFC-404A/R23 Refrigerants |
| Compressor | Hermetic Scroll Compressor (Tecumseh or Bitzer Equivalent) |
| Humidity Control | Optional Capacitive Sensor + PID Algorithm |
| Safety Protections | Over-Temperature Cut-Off, Compressor High-Pressure & Overcurrent Protection, Dry-Run Prevention, Liquid Level Monitoring, Emergency Stop |
| Brand | APKJ |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP-GD-225A1 |
| Temperature Range | −40 °C to +150 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Heating Rate | 1–3 °C/min |
| Cooling Rate | 0.7–1 °C/min |
| Operating Temperature Range (Dust Mode) | RT+5 °C to 60 °C |
| Airflow Velocity | 0–3.5 m/s |
| Sieve Mesh Wire Diameter | 75–100 µm (100–200 mesh) |
| Test Dust | Talcum Powder, 2–4 kg/m³ |
| Dust Blowing Cycle | Programmable Intermittent Control |
| Optional Vacuum System | Available upon request |
| Chamber Internal Dimensions (W×H×D) | 1000 mm × 1000 mm × 1000 mm |
| Dust Retention Mesh Wire Diameter | 50 µm |
| Humidity Control | Capacitive or Dry/Wet Bulb Sensor-Based |
| Controller | Multi-Stage Programmable PID Controller with Fuzzy Logic Algorithm |
| Refrigerant | Eco-Friendly Non-CFC/HFC-Free Refrigerant |
Show next