Conductivity Range0.0 µS/cm to 200 mS/cm
Temperature Range−10.0 to 120.0 °C
Accuracy±2.0% FS (instrument)
Resolution0.001 µS/cm (selectable: 0.001 / 0.01 / 0.1 / 1 µS/cm)
Dimensions166 × 166 × 110 mm
Weight2 kg
IP RatingIP65
OutputIsolated 4–20 mA DC & RS-485
Sensor Cable Length10 m (standard)
Auto-Temperature Compensation−10 to 120 °C
Electrode Compatibility2-electrode and 4-electrode conductivity cells
Data Storage Capacity2000 records
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Model6890 Plus GC + 5973 MSD
ConfigurationGC-MS System for VOC/SVOC Quantification per GB/T 23986.2–2023
ConditionProfessionally Refurbished & Functionally Verified
ComplianceFully Compatible with ASTM D6886, ISO 11890-2, and US EPA Method 8260D workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelBrand- and Model-Agnostic
Service FeeUSD 1,500–3,000 (custom quoted)
Relocation Experience10+ years
Response TimeWithin 24 hours
Service ScopeFull-service laboratory instrument relocation
CoverageNationwide (U.S.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeichi
ModelPHGF Series
TypepH and ORP Transmitter
Mounting OptionsSubmersible (PHGF-27B, PHGF-28B, PHGF-43) / Flow-Through (PHGF-28B, PHGF-46)
Integrated Pre-amplifier BoardYes (PHGF-27B, PHGF-28B, PHGF-43) / No (PHGF-46)
Cable Length20 m (PHGF-27B, PHGF-28B, PHGF-43) / 10 m (PHGF-46)
Operating Temperature Range5–60 °C or 20–90 °C (selectable, PHGF-27B & PHGF-28B) / 5–45 °C (PHGF-43) / 5–55 °C (PHGF-46)
Compatible ElectrodesFG-990 (pH), ORP-1 (ORP)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ModelAgilent 7890B + 5977B
ConfigurationGas Chromatography–Mass Spectrometry (GC-MS) System
Vacuum SystemHigh-Performance Turbomolecular Pump
Ion SourceDual-Filament EI Source, Inert (Non-Coated, Non-Stainless Steel)
Mass AnalyzerGold-Plated Quartz Quadrupole with Turner-Kruge Lenses
Mass Range1.6–1050 u (0.1 u increments)
ResolutionUnit Mass Resolution
Mass Stability≤0.10 u / 48 h
Full-Scan Sensitivity (EI)≥400:1 S/N for 1 pg OFN (m/z 272, 50–300 u scan)
SIM Sensitivity (EI)≥10:1 S/N for 20 fg OFN
Max Scan Rate12,500 u/s (1 ms dwell in SIM)
Dynamic Range10⁶
SIM Capacity100 groups, up to 60 ions/group
GC Oven Temp Range4 °C above ambient to 450 °C
Max Ramp Rate120 °C/min
Temperature Stability<0.01 °C per 1 °C ambient change
Programmable Temperature Zones≥6 heated zones (including inlet, detector, transfer line), all independently controlled up to 400 °C
EPC Pressure Control Accuracy±0.001 psi
Split/Splitless InletUp to 7500:1 split ratio, 0–1250 mL/min H₂/He flow range
Auto-sampler16-position (standard), optional 150-position tray
Detectors IncludedFID (detection limit <1.8 pg C/s), micro-ECD (<6 fg/mL lindane), NPD (<0.4 pg N/s, <0.2 pg P/s)
ComplianceFully compatible with EPA Methods (e.g., 502.2, 524.4, 8260, 8270), USP <621>, ASTM D5845, and GLP/GMP data integrity requirements per FDA 21 CFR Part 11
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelPHB-5
Instrument TypePortable
Parameter TypesMulti-parameter
pH Accuracy±0.01 pH
pH Range−2.00 to 18.00 pH
pH Resolution0.01 pH
mV Range−1999 to +1999 mV
mV Resolution1 mV
mV Accuracy±0.1% FS
Temperature Range−5.0 to 110.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.2 °C
Calibration BuffersGB Standard pH 4.00, 6.86, and 9.18
Power SupplyRechargeable Li-ion battery
AC/DC adapter (InputAC 100–240 V, Output: DC 5 V)
Dimensions80 × 225 × 35 mm
Weight0.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelSGW®-537
Product TypeAutomated Polarimeter
Temperature ControlPeltier-integrated (10–50 °C, ±0.2 °C accuracy)
Display8-inch color TFT touchscreen
Light Source20 W halogen lamp
Standard Wavelengths546 nm, 589 nm
Optional Wavelengths365, 405, 436, 578, 633 nm (7 total)
Measurement Range±90° (optical rotation), ±259°Z (saccharimetric scale)
Minimum Resolution0.001°
Accuracy±0.004°
Repeatability (σ)≤0.002°
Zero repeatability0.001°
Response Speed8°/s (full scale)
Avg. Measurement Time26 s (6 measurements)
Sample Transmittance Limit≥0.1%
Data Storage16 GB internal
Compliance OptionsFDA 21 CFR Part 11 audit trail software (optional), GMP/GLP-ready configuration
OSWindows-based, LIMS-compatible
InterfacesUSB, VGA, Ethernet, optional Wi-Fi & thermal printer
Standard Cells100 mm / 200 mm pathlength (ambient & thermostatted)
Dimensions702 × 376 × 240 mm
Net Weight21 kg
CalibrationMulti-point automatic calibration
Regulatory ConformanceJJG 536–2015 Class 0.01
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelSJG-705
Instrument TypeOnline
pH Range0.00–14.00 (Res: 0.01, Acc: ±0.05 pH ±1 digit)
ORP Range±1999 mV (Res: 1 mV, Acc: ±10 mV ±1 digit)
Conductivity0.000 µS/cm–19.9 mS/cm (Res: 0.1/1 µS/cm, 0.01 mS/cm
Acc±2.0% FS)
TDS0.000 mg/L–9.9 g/L (Res: 0.1 mg/L, 0.01 g/L)
Turbidity0.00–500.0 NTU (Res: 0.01 NTU, Acc: ±10%)
Dissolved Oxygen0.00–20.00 mg/L / 0.0–200.0% sat (Res: 0.01 mg/L, 0.1%
Acc±0.50 mg/L & ±10% sat)
Temperature−10.0–120.0 °C (Res: 0.1 °C, Acc: ±0.5 °C ±1 digit @ 0–60 °C)
CommunicationRS-232 / RS-485 / Ethernet (selectable)
PowerAC 220 V ±10%, 50 Hz
Dimensions560 × 400 × 1680 mm
Weight50 kg