Empowering Scientific Discovery

Hangzhou Kexiao Chemical Instrument & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Model7890B + 7000C/D
ConfigurationGC with ALS G7693A, Heated EI Extractor Ion Source, Gold-Plated Quadrupole Mass Filters, HED-EM Detector, Dual Turbo Molecular Pumping System, MassHunter Software Suite
ComplianceASTM D5845, EPA Methods 8270/1613/1631, USP <621>, ISO/IEC 17025
Service HistoryFully Refurbished & Performance-Verified per Agilent OEM Standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGCMS-QP2010Plus
ConditionRefurbished & Fully Qualified
ComplianceMeets Original Shimadzu Factory Specifications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelQP2010
ConfigurationVOC/SVOC Analysis-Optimized (per GB/T 23986.2–2023)
Regulatory AlignmentCompliant with ISO 11843, ASTM D6886, and US EPA Method TO-17 for VOC quantification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ModelAgilent 7890B + 5977A
ConfigurationGas Chromatography–Mass Spectrometry (GC-MS) System
Ion SourceHigh Efficiency Source (HES) with Electron Ionization (EI)
Detection Limit (IDL)1.5 fg (as reported for chlorobenzene, per Agilent specification)
Sensitivity GainUp to 10× vs. prior-generation single quadrupole MSDs
Pump OptionIDP-3 Dry Scroll Vacuum Pump (optional, low-noise, oil-free operation)
Software PlatformAgilent MassHunter Workstation (v10.x or later, license transferable per Agilent policy)
ComplianceDesigned to support GLP/GMP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGCMS-QP2020 NX
ConfigurationSingle Quadrupole GC-MS
Vacuum SystemDual-stage Turbo Molecular Pump (High-Capacity)
Ionization ModesElectron Impact (EI) and Chemical Ionization (CI) with Quick-CI™
Gas ControlAdvanced Flow Control (AFC) with Constant Linear Velocity (CLV) mode
Scan SpeedUp to 20,000 u/sec with ASSP™ (Advanced Scanning Speed Protocol)
Software PlatformLabSolutions Insight v2.x with GCMS Insight, Smart SIM, AART, and Retention Index–Enabled Libraries
Compliance SupportASTM D5847, ISO 17025 workflows, USP <621>, FDA 21 CFR Part 11 audit trail ready (configuration-dependent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Model7890A + 7000A/B
ConfigurationGas Chromatography–Triple Quadrupole Mass Spectrometry (GC–MS/MS)
Ion SourceElectron Ionization (EI)
Collision GasNitrogen/He Mix
Detector TypeTriple Quadrupole (QqQ)
Regulatory Compliance SupportASTM D5845, EPA Method 8270/1613/1631, USP <621>, FDA 21 CFR Part 11 (Software-Enabled)
Data SystemMassHunter Workstation (vB.08.x or later)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginUSA
Model450-GC+300MS
ConfigurationGC-MS/MS (Triple Quadrupole)
Instrument ConditionRefurbished & Fully Qualified Used System
Regulatory ComplianceDesigned to meet ASTM D5845, EPA Method 8270/8260, and ISO 17025 laboratory requirements
Software PlatformBruker Compass DataAnalysis 5.4+ with QuantAnalysis and TargetScreener modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Instrument OriginImported
Model7890B + 7010B
PriceUSD 95,000 (FOB)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelDFS High-Resolution Magnetic Sector GC/MS
ConfigurationDual-Trace 1300 GC + TriPlus RSH Autosampler
DetectorDual-mode Faraday Cup / Secondary Electron Multiplier (SEM)
Mass ResolutionUp to 10,000–100,000 (M/ΔM, 10% valley)
Mass Accuracy< 1 ppm (with internal lock mass)
Ion SourceRemovable, maintenance-optimized EI/CI source
Vacuum SystemPneumatic valve–locked ion box
ComplianceFully compatible with EPA Methods 1613, 23, 8270, USP <1225>, ISO/IEC 17025, and GLP/GMP audit trails (when configured with Thermo Xcalibur 3.1+ and 21 CFR Part 11–enabled software modules)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginUSA
ModelGC456-SCION TQ
ConfigurationUsed, Refurbished & Fully Qualified Triple Quadrupole GC-MS/MS System
ComplianceMeets ASTM D5845, EPA Method 8270/8260, and ISO 17025-aligned operational readiness standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Model7890A + 5975C
Ion Source Temp Range100–300 °C (independently controlled)
Electron Energy10–200 eV
Sensitivity (EI)≥185:1 S/N for 1 pg OFN (m/z 272, full scan)
Sensitivity (NCI)≥300:1 S/N for 10 fg OFN (m/z 272, SIM)
Mass Range1.5–1050 amu
ResolutionUnit mass
Scan Speed≥10,000 amu/sec
Mass Axis Stability≤0.1 amu/48 h
DetectorOff-axis electron multiplier
QuadrupoleAll-metal molybdenum, pre-filtered, permanently contamination-resistant
Carrier Gas OptionsHelium, Hydrogen, Nitrogen
SoftwareMSD ChemStation with Deconvolution Reporting Software (DRS), Retention Time Locking (RTL), Capillary Flow Technology support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGCMS-QP2010
Price¥150,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model6890N + 5973N
PriceUSD 22,000 (FOB)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGCMS-QP2020
GC UnitGC-2010
Oven Temperature Range2 °C above ambient to 450 °C
Column Oven Ramp RateUp to 120 °C/min
Injector Temperature RangeAmbient to 450 °C
AFC Pressure Range0–1035 kPa
Retention Time Reproducibility<0.0008 min
Peak Area RSD<1%
MS Interface Temperature50–350 °C
Ion SourceFront-access, maintenance-friendly EI/CI/NCI source with dual filaments
Ionization Energy10–200 eV
Filament Current5–250 µA
Mass AnalyzerAll-metal quadrupole with pre-quadrupole
m/z Range1.5–1090
Optional DI ProbeAmbient to 500 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJEOL
OriginJapan
ModelJMS-800D
ConfigurationMagnetic Sector GC-MS System for Dioxin Analysis
Detector TypePhotomultiplier Tube (PMT)
SoftwareDiok Suite for Dioxin/Furan Quantitation
Vacuum SystemOil-diffusion or Turbo-molecular Pumping (Typical for JMS-800D Era)
Mass Resolution>10,000 (10% Valley) at m/z 320
Mass RangeUp to m/z 1000
Ion SourceElectron Ionization (EI), Dual-Channel Design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelQP2010 Ultra
PriceUSD 27,500 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGCMS-TQ8040
ConfigurationRefurbished Unit with Full Functional Validation
ComplianceMeets Original Shimadzu Factory Specifications for GC-MS/MS Operation
SoftwareIncludes Licensed GCMSsolution Ver. 5.x (with Smart MRM, ASSP, and Scan/MRM Simultaneous Acquisition Modules)
Instrument StatusFully Recertified with Performance Verification Report (PVR) per ISO/IEC 17025 Traceable Protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelTRACE GC Ultra + TSQ Quantum GC/XLS/ULTRA
ConfigurationUsed, Fully Functional, Pre-Owned
ComplianceMeets Original Factory Specifications (as verified per pre-delivery QC checklist)
Service HistoryFull maintenance log available upon request
Calibration StatusRequires user-site requalification per ISO/IEC 17025 or GLP protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Model6890 Plus GC + 5973 MSD
ConfigurationGC-MS System for VOC/SVOC Quantification per GB/T 23986.2–2023
ConditionProfessionally Refurbished & Functionally Verified
ComplianceFully Compatible with ASTM D6886, ISO 11890-2, and US EPA Method 8260D workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ModelAgilent 7890B + 5977B
ConfigurationGas Chromatography–Mass Spectrometry (GC-MS) System
Vacuum SystemHigh-Performance Turbomolecular Pump
Ion SourceDual-Filament EI Source, Inert (Non-Coated, Non-Stainless Steel)
Mass AnalyzerGold-Plated Quartz Quadrupole with Turner-Kruge Lenses
Mass Range1.6–1050 u (0.1 u increments)
ResolutionUnit Mass Resolution
Mass Stability≤0.10 u / 48 h
Full-Scan Sensitivity (EI)≥400:1 S/N for 1 pg OFN (m/z 272, 50–300 u scan)
SIM Sensitivity (EI)≥10:1 S/N for 20 fg OFN
Max Scan Rate12,500 u/s (1 ms dwell in SIM)
Dynamic Range10⁶
SIM Capacity100 groups, up to 60 ions/group
GC Oven Temp Range4 °C above ambient to 450 °C
Max Ramp Rate120 °C/min
Temperature Stability<0.01 °C per 1 °C ambient change
Programmable Temperature Zones≥6 heated zones (including inlet, detector, transfer line), all independently controlled up to 400 °C
EPC Pressure Control Accuracy±0.001 psi
Split/Splitless InletUp to 7500:1 split ratio, 0–1250 mL/min H₂/He flow range
Auto-sampler16-position (standard), optional 150-position tray
Detectors IncludedFID (detection limit <1.8 pg C/s), micro-ECD (<6 fg/mL lindane), NPD (<0.4 pg N/s, <0.2 pg P/s)
ComplianceFully compatible with EPA Methods (e.g., 502.2, 524.4, 8260, 8270), USP <621>, ASTM D5845, and GLP/GMP data integrity requirements per FDA 21 CFR Part 11
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0