Empowering Scientific Discovery

Hangzhou Kexiao Chemical Instrument & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelZDY-501
PricingUSD 680 (FOB Shanghai)
Titration ModeFully Automatic Volumetric and Coulometric Dual-Mode
Instrument TypeDual-Principle Karl Fischer Moisture Analyzer (Volumetric + Coulometric)
Water Content Range0.1 mg to 250 mg
Measurement Accuracy±3% RSD
Minimum Dispensing Resolution1/20,000 of full-scale burette volume
Polarization Current1 µA
Endpoint Detection Voltage Range40–120 mV
Sample Temperature Range5–30 °C
Dimensions (W×D×H)280 × 210 × 120 mm
Net Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeiCi
ModelDGB-423
Measurement ParameterAmmonia-Nitrogen (NH₃-N)
MethodNesslerization Spectrophotometry
Light Source420 nm LED
Range0.000–4.000 mg/L
Accuracy±10% FS
Repeatability≤3% RSD
Sample Vessel16 mm OD × 100 mm glass cuvette (10 mL)
Dimensions220 × 85 × 50 mm
Weight0.4 kg
Operating Environment5–35 °C, 0–85% RH
Power Supply4 × AA alkaline batteries or USB 5 V DC
DisplayBacklit LCD with adjustable contrast and backlight timeout
Protection RatingIP65
CalibrationUp to 5-point user-defined calibration
Data ManagementGLP-compliant storage, review, deletion, and print export via USB
Firmware UpgradeableYes
ComplianceSupports audit-trail-ready data handling per GLP requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDWG-8002A
Instrument TypeOnline Analyzer
Measurement PrincipleAmmonia Gas-Sensing Electrode Method
Measurement Range0.05–1000.00 mg/L NH₃–N
Accuracy±0.2 mg/L (≤2.00 mg/L)
Repeatability≤2.0% (0.10–10.00 mg/L), ≤5.0% (10.00–1000.00 mg/L)
Drift (24 h)≤0.02 mg/L (low range), ≤2% (high range)
Minimum Detection Limit≤0.15 mg/L
Output SignalIsolated 4–20 mA DC (max load 600 Ω), RS-485
Data Storage4000 measurement records + 500 calibration logs
Power SupplyAC 220 V ±10%, 50 Hz
Dimensions470 × 325 × 700 mm (L×W×H)
Weight~32 kg (dry)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Model7890B + 7000C/D
ConfigurationGC with ALS G7693A, Heated EI Extractor Ion Source, Gold-Plated Quadrupole Mass Filters, HED-EM Detector, Dual Turbo Molecular Pumping System, MassHunter Software Suite
ComplianceASTM D5845, EPA Methods 8270/1613/1631, USP <621>, ISO/IEC 17025
Service HistoryFully Refurbished & Performance-Verified per Agilent OEM Standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBoxun
OriginShanghai, China
ModelBXM-75M
Instrument TypeVertical
Max Temperature135°C
Max Working Pressure0.22 MPa
Chamber DimensionsØ400 × 700 mm
External Dimensions750 × 800 × 1080 mm
Chamber Volume75 L
Sterilization Temp Range105–135°C
Drying Temp Range102°C
Melting Temp Range40–100°C
Holding Temp Range25–85°C
Sterilization Time4–120 min
Drying Time0–999 min
Melting/Holding Time0–999 min
Delay StartUp to 99 h 60 min
Design Pressure0.25 MPa
Drying Residual Moisture<1%
Heating Power5.9 kW
Power Supply~220 V ± 22 V, 50 Hz ± 1 Hz
Ambient Operating Conditions5–40°C, 20–80% RH
Chamber & Basket MaterialSUS304 stainless steel
Cooling MethodForced-air rapid cooling
Air Intake FiltrationBuilt-in HEPA-grade filter
Dual Water Inlet SystemSelectable pure water or tap water
Condensate Recycling System (C.W.S.)Integrated
Waste Gas & Effluent Purification System (W.P.S.)Integrated
Standard Sample Temperature ProbeYes
Data Logging & ExportYes
Safety FeaturesMechanical self-locking + electronic interlock door, overtemperature cutoff, independent safety limiter, overpressure relief valve, fault self-diagnosis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Instrument TypeBenchtop Laboratory Conductivity Meter
Measurement ParameterSingle-parameter (Conductivity)
Conductivity Range0.00 µS/cm to 200 mS/cm
Accuracy±1.0% FS
Minimum Resolution0.01 µS/cm (auto-ranging)
Temperature CompensationManual
Calibration1-point calibration with auto-recognition of 4 GB-standard conductivity solutions
Electrode Constant SupportAutomatic frequency switching compatible with K = 1.0 cell
Data Storage50 measurement sets
DisplayHigh-resolution LCD with key-based navigation
Enclosure RatingIP54
Power SupplyAC/DC adapter (Input: 100–240 V AC
Output20 V DC / 1500 mA)
Dimensions (W×D×H)242 × 195 × 68 mm
Weight0.9 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelDGB-404F
Instrument TypePortable/Handheld Colorimetric Water Quality Analyzer
Measurement PrincipleDPD (N,N-Diethyl-p-phenylenediamine) Colorimetric Method
Wavelength545 nm LED Source
Measurement Range0.00–2.00 mg/L Cr(VI)
Accuracy±0.05 mg/L (≤1 mg/L)
Detection Limit≤0.02 mg/L
Calibration PointsUp to 5-point user-defined calibration
Data Storage200 measurement records with timestamp, operator ID, and calibration metadata
Cuvette Format16 mm round glass or plastic tubes
Power Supply4 × AA alkaline batteries (1.5 V) or USB 5 V DC
IP RatingIP65
Dimensions (L×W×H)230 × 85 × 50 mm
Weight~0.4 kg
ComplianceSupports GLP data integrity requirements (audit trail-capable storage, user authentication via ID entry)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelBSC-1360A2
Instrument TypeClass II A2 Biological Safety Cabinet
External Dimensions (L×W×H)1420 × 860 × 2225 mm
Internal Work Area Dimensions (L×W×H)1300 × 500 × 640 mm
HEPA Filter Efficiency≥99.99% @ 0.3 µm
Inflow Velocity0.55 m/s ±0.02 m/s
Downflow Velocity0.35 m/s ±0.02 m/s
Air Recirculation Ratio70%
Exhaust Ratio30%
Noise Level≤67 dB(A)
Vibration Peak-to-Peak≤5 µm
Average Illuminance≥650 lux
Operating Temperature Range10–30 °C
Relative Humidity Limit≤70% @ 25 °C
Atmospheric Pressure Range80–105 kPa
Personnel Protection Factor (KI Test)≥1×10⁵
Product Protection (Settle Plate)≤5 CFU/plate/test
Cross-Contamination Protection (Impactor Sampler)≤2 CFU/plate/test
Lighting & UV Lamp30 W × 1 each
Total Power Consumption1.4 kW
Electrical SupplyAC 220 V ±10%, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao
OriginZhejiang, China
ModelSGN-300
Output Flow0–300 mL/min
Output Pressure0–0.4 MPa (factory-set at 0.4 MPa)
Nitrogen Purity≥99.999%
Dew Point≤−40 °C
Power Consumption150 W
Dimensions (L×W×H)390 × 185 × 320 mm
Weight10 kg
Input PowerAC 220 V, 50 Hz
Operating Temperature5–40 °C
Relative Humidity<85% RH (non-condensing)
ConstructionStainless steel electrolytic cell with noble-metal catalyst layer
Purification MethodIntegrated physical adsorption and electrochemical separation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelWRS-1C
Temperature RangeAmbient to 400 °C
Heating Rate0.1–20 °C/min (continuously adjustable)
Temperature Repeatability±0.3 °C (at 1 °C/min)
Temperature Accuracy±0.4 °C ≤200 °C
Temperature Resolution0.1 °C
Capillary DimensionsOD 1.4 mm, ID 1.0 mm, Length 90 mm
Sample Capacity1 capillary per run
Display7-inch color TFT touchscreen
Data Storage1000 measurement records
InterfaceRS232 and USB
Power Supply220 V ±10%, 50 Hz, 80 W
Dimensions360 × 290 × 170 mm
Net Weight9 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYidian Wuguang (YDWG)
OriginShanghai, China
ModelWGW
TypeManual Operation
Haze Range0–30%
Transmittance Range0–100%
Haze Repeatability≤0.2%
Transmittance Repeatability≤0.5%
Light SourceC-illuminant (6774 K)
Minimum Display Resolution0.1% (both haze and transmittance)
Accuracy±0.5% (haze), ±1.5% (transmittance)
Sample ChamberClosed-type, 50 mm × 50 mm max sample size
Dimensions470 mm × 270 mm × 160 mm
Net Weight7 kg
Power Supply220 V ± 22 V, 50 Hz ± 1 Hz, 30 W
DisplayLCD, 3½-digit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield (BOXUN)
OriginShanghai, China
ModelBXM-60EI
Instrument TypeVertical
Max Temperature150 °C
Max Pressure0.38 MPa
Chamber DimensionsØ400 × 635 mm
External Dimensions535 × 640 × 1075 mm
Chamber Volume60 L
Temperature Uniformity±0.5 °C
Temperature Fluctuation< +1 °C
Sterilization Time Range0–120 min (customizable up to 6000 min)
Power Supply~220 V ±22 V, 50 Hz ±1 Hz
Heating Power3.2 kW
Ambient Operating Conditions5–40 °C, 20–80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ConfigurationStandalone Detectors for HPLC Systems
Model Designation1100/1200 FLR Detector (G1321A/G1321B) and 1200 RID (G1362A)
ComplianceFully Tested per Agilent Functional Specifications
ConditionProfessionally Refurbished, Factory-Calibrated, Ready for GLP-Compliant Operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelBSC-1360B2
Instrument TypeClass II Biological Safety Cabinet
External Dimensions (L×W×H)1420 × 895 × 2340 mm
Internal Work Area Dimensions (L×W×H)1300 × 500 × 640 mm
HEPA Filter Efficiency≥99.99% @ 0.3 µm
Inflow Velocity0.55 m/s
Downflow Velocity0.33 m/s
Downflow Control Accuracy±0.015 m/s
Pressure Differential Range0–500 Pa
Noise Level≤67 dB(A)
Vibration Half-Peak≤5 µm
Average Illuminance≥650 lx
Operating Ambient Temperature10–30 °C
Relative Humidity≤70% @ 25 °C
Atmospheric Pressure Range80–105 kPa
Power SupplyAC 220 V ±10%, 50/60 Hz
Total Power Consumption2.2 kW
Lighting2 × 40 W fluorescent lamps + 1 × 30 W UV lamp
Supply Filter Size1326 × 606 × 70 mm
Exhaust Filter Size782 × 515 × 90 mm
Work SurfaceRemovable SUS304 stainless steel with integrated liquid collection trough and drain valve
Airflow SensorsImported U.S.-made constant-velocity anemometers
Fan SystemEBMPAPST (Germany) centrifugal blowers
Safety InterlocksUV/light interlock, sash position alarm, fan shutdown at sash closure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYiDian Analytical
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelFP6400A
Price RangeUSD 2,200 – 12,600 (FOB Shanghai)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelZDJ-5B-T
Instrument TypeGeneral-purpose Potentiometric Titrator
Application ScopeUniversal
Measurement Range(−2000.00 to +2000.00) mV
Meter AccuracymV: ±0.03% or ±0.2 mV
pH±0.002 pH
Meter Resolution0.01 mV, 0.001 pH
Titration Precision0.0003 mL
Titration Resolution1/30000
Added to wishlistRemoved from wishlist 1
Add to compare
BrandLeici
OriginShanghai, China
ModelJB-12
Stirrer TypeMagnetic Stirrer
Speed Range60–2000 rpm
Housing MaterialPolycarbonate (PC)
Panel MaterialPolyethylene Terephthalate (PET)
Stirring ModeContinuous Rotational
Direction ControlClockwise & Counterclockwise
IP RatingIP65
Dimensions (L×W×H)110 × 169 × 109 mm
Timer FunctionNot Supported
Speed DisplayNot Supported
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBOXUN
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelVS-840-2
Instrument TypeVertical Flow Clean Bench
Cleanliness ClassISO Class 5 (100-grade, ≥99.99% filtration efficiency for particles ≥0.5 µm)
Noise Level≤67 dB(A)
User CapacitySingle-operator, dual-front access
Airflow PatternVertical downward laminar flow
Work Area Dimensions (W×D×H)830 × 650 × 520 mm
Overall Dimensions (W×D×H)990 × 700 × 1650 mm
HEPA Filter Specification780 × 565 × 50 mm (1 unit)
Pre-filterMedium-efficiency panel filter
Air Velocity Range0.3–0.6 m/s (adjustable in six steps)
Illumination≥300 lux
UV Lamp20 W × 1 (timer-controlled, 0–999 min)
Fluorescent Lamp20 W × 1
Vibration Amplitude (peak-to-peak)≤5 µm (X/Y/Z axes)
Weight120 kg
Power Consumption0.15 kW
Electrical SupplyAC 220 V ±10%, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelLC-40X3B
CategoryLiquid Chromatograph (HPLC/UHPLC)
ConfigurationLC Front-End for LC-MS Coupling
Warranty12 months
ComplianceDesigned for ISO/IEC 17025, GLP, and FDA 21 CFR Part 11–ready workflows
Software PlatformLabSolutions LCMS v5.1 or later
Power Consumption (Standby)≤68% reduction vs. prior generation
Auto-sampler Injection Speed≤5 sec per injection
Carryover<0.001% (typical, validated with caffeine/benzodiazepine test mixtures)
Sample CapacityUp to 44 × 96-well MTP plates via optional Plate Changer
Dual-Independent Flow Path SupportYes (via SIL-40CX dual-inlet configuration)
Temperature ControlActive airflow management in sample compartment (±0.5 °C stability, condensation-suppressed)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelPHB-4
Instrument TypePortable
Parameter TypesMulti-parameter
pH Range(0.00–14.00) pH
Resolution0.01 pH
Accuracy±0.03 pH
Calibration StandardsGB buffer solutions at pH 4.00, 6.86, and 9.18
mV Range(−1400–1400) mV
mV Resolution1 mV
mV Accuracy±0.2% FS
Temperature CompensationManual
IP RatingIP65
Dimensions80 × 225 × 35 mm
Weight0.4 kg
PowerRechargeable Li-ion battery
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelHS-20 / HS-20LT / HS-20 TRAP (90-position)
ConfigurationQuantitative Loop or Cold Trap Mode
Sample Capacity90 vials (20 mL standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWO
OriginShanghai, China
ModelWYA-2S
Product TypeBenchtop Refractometer
DisplayDigital LCD
Measurement Range (nD)1.3000–1.7000
Resolution (nD)0.0001
Accuracy (nD)±0.0002
Temperature Display Range0–50 °C
Power Supply220 V ± 22 V, 50 Hz ± 1 Hz, 30 W
Dimensions290 × 180 × 390 mm
Net Weight10 kg
ComplianceGB/T 12143–2008, GB/T 18963–2012, GB/T 21730–2008
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJiedao
OriginZhejiang, China
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose with Pesticide Residue Focus
Temperature Control Zones6 independent zones (including column oven, injector, detector, AUX1–AUX3)
Column Oven Temp Range+7 °C to 420 °C
Programmed Temperature Ramping5-step linear ramping
Injector Max Temp420 °C
Carrier Gas Pressure ControlElectronic pressure control (EPC) compatible
Carrier Gas Flow ControlMass flow controller (MFC) optional
Detector CompatibilityFID, TCD, FPD, NPD, ECD (up to 3 simultaneously)
Injection ModesSplit/splitless, on-column, packed-column vaporizing, WBC for wide-bore capillary, 6-port gas sampling valve
Safety ProtectionsOver-temperature, over-current (TCD), and system crash protection circuits
Data InterfaceRS-232 or USB (legacy PC connectivity)
ComplianceDesigned to support GLP-compliant workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeichi
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSJG-750
PricingAvailable Upon Request
pH Range0–14 pH, Resolution: 0.01 pH, Accuracy: ±0.05 pH ±1 digit
Conductivity Range0–200.0 mS/cm, Accuracy: ±1.5% FS
Dissolved Oxygen Range0.00–20.00 mg/L, Resolution: 0.01 mg/L, Sensor Error: ±0.2 mg/L
Turbidity Range0–1000 NTU, Resolution: 0.1 NTU, Linearity Error: ±5%
Temperature Range0.0–60.0 °C, Resolution: 0.1 °C, Accuracy: ±0.5 °C ±1 digit
Power SupplyAC 220 V ±10%, 50 Hz ±2%
Dimensions285 × 205 × 97 mm, Weight: 3 kg