BrandYDWG
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic (PRC-manufactured)
ModelSGW®-1
PricingUpon Request
Instrument TypeAutomatic Polarimeter
Temperature ControlNot Equipped
Digital DisplayYes
Light SourceHigh-Efficiency LED
Optical Path Length Compatibility100 mm & 200 mm cells
Measurement Range±45° (optical rotation), ±120°Z (saccharimetric scale)
Minimum Resolution0.001° (optical rotation), 0.01°Z (sugar scale)
Accuracy±(0.05° + 0.03% of reading) for optical rotation
Repeatability (Std. Dev. δ)≤0.002°
Wavelength589.3 nm (Na D-line equivalent, stabilized via LED + interference filter)
Display7-inch color TFT touchscreen
InterfaceRS232 and USB
Power Supply220 V ±10%, 50 Hz ±1 Hz, 150 W
Dimensions (L×W×H)710 × 400 × 240 mm
Net Weight28 kg
Accuracy Class0.02
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelWXG-4 (Sodium Lamp)
Product TypeCircular Scale Polarimeter
Temperature ControlNot Available
Digital DisplayNone
Light SourceSodium Lamp (589 nm)
Measurement Range±180°
Angular Resolution0.05°
Angular Accuracy0.05°
Scale Division
Eyepiece Magnification
Sample Tube Length Options100 mm / 200 mm
Power Supply220 V ± 22 V, 50 Hz ± 1 Hz
Dimensions (L×W×H)435 mm × 135 mm × 320 mm
Net Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelWXG-4L
Product TypeCircular Scale Visual Polarimeter
Temperature ControlNone
Digital DisplayNone
Light SourceLED (589 nm via interference filter)
Measurement Range±180°
Angular Resolution0.05°
Angular Accuracy±0.05°
Scale Division
Eyepiece Magnification
Sample Tube Lengths100 mm and 200 mm (standard)
Power Supply220 V ± 22 V, 50 Hz ± 1 Hz
Dimensions (L×W×H)435 × 135 × 320 mm
Net Weight3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
Product TypePolarimeter Sample Cells (for Circular Dichroism & Optical Rotation Measurement)
Material OptionsBorosilicate Glass, Quartz, Stainless Steel, Hastelloy C-276
Cell Pathlengths50 mm to 200 mm
Internal DiametersØ5 mm to Ø9 mm
Sample Volumes0.8 mL to 21 mL
Calibration ComplianceTraceable to NIM (National Institute of Metrology, China)
Optional CertificationsISO/IEC 17025-compliant calibration certificate, IQ/OQ/PQ documentation support, NIST-traceable quartz standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelSGW®-532
Product TypeAutomatic Polarimeter
Temperature ControlPeltier-based (heating & cooling)
Display8-inch color TFT touchscreen
Light SourceLED with precision interference filter (589 nm, Na D-line equivalent)
Measurement Range±90° (optical rotation), ±259°Z (saccharimetric scale)
Minimum Resolution0.001°
Accuracy±0.004°
Repeatability (σ)≤0.002°
Zero Repeatability0.001°
Response Speed8°/s (full-scale)
Avg. Measurement Time26 s (6 readings)
Temp. Control Range10–50 °C
Temp. Accuracy±0.2 °C
Sample Transmittance Limit≥0.1%
Data Storage Capacity10,000 records
ComplianceJJG 536–2015 Class 0.01
InterfacesUSB, RS232, dedicated printer port, USB flash drive support
Power220 V ±22 V, 50 Hz ±1 Hz, 200 W
Dimensions (W×D×H)702 × 376 × 240 mm
Net Weight21 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYidian Woguang (YDWG)
OriginShanghai, China
ModelWZZ-2B
Product TypeAutomatic Polarimeter
Temperature ControlNone
Digital DisplayYes
Light SourceLED with Interference Filter
Wavelength589 nm (Sodium D-line)
Measurement Range±45° (optical rotation)
Minimum Resolution0.002°
Accuracy±0.02° (for –15° to +15°), ±0.05° (outside that range)
Repeatability (σ)≤0.01°
Sample Transmittance Requirement≥10%
Standard Cells100 mm and 200 mm path length
InterfaceRS232
Power Supply220 V ±22 V, 50 Hz ±1 Hz, 150 W
Dimensions605 × 370 × 260 mm
Net Weight21 kg
Accuracy Class0.05
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelSGW®-2
Product TypeAutomatic Polarimeter
Temperature ControlYes (Peltier-based)
Display7-inch Color Touchscreen LCD
Light SourceLED with Interference Filter
Wavelength589 nm (Na D-line)
Measurement Range±45° (optical rotation), ±120°Z (saccharimetric scale)
Minimum Resolution0.001° (optical rotation), 0.01°Z (sugar scale)
Accuracy±0.01° (for –15° ≤ α ≤ +15°), ±0.02° (outside that range)
Repeatability (σ)≤0.002°
Temperature Control Range15–30 °C
Temperature Stability±0.5 °C
Sample Transmittance Limit≥1%
InterfacesRS232, USB
Dimensions710 × 400 × 240 mm
Net Weight28 kg
Accuracy Class0.02
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelSGW®-531
Product TypeAutomatic Polarimeter
Temperature ControlNone
Digital DisplayYes
Light SourceLED (589 nm, Na D-line equivalent)
Measurement Range±90° (optical rotation), ±259°Z (saccharimetric scale)
Minimum Readability0.001°
Accuracy±0.006°
Repeatability (Std. Dev. δ)≤0.002°
Zero Repeatability0.001°
Minimum Sample Transmittance0.1%
Response Speed8°/s (full scale)
Average Measurement Time26 s (6 measurements)
Data Storage Capacity10,000 records
Communication InterfacesUSB, RS232, dedicated printer port, USB flash drive support
Standard Cell Path Lengths100 mm and 200 mm
Optional Cells50 mm micro-cell
Power Supply220 V ±22 V, 50 Hz ±1 Hz, 200 W
Dimensions (L×W×H)702 × 376 × 240 mm
Net Weight21 kg
ComplianceJJG 536–2015 Class 0.01
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelWZZ-1
Instrument TypeAutomatic Polarimeter
Light SourceSodium Lamp (589 nm)
Measurement Range±45° (optical rotation)
Minimum Scale Division0.001°
Accuracy Class0.05
Permissible Error±(0.01 + 0.05% of reading)°
Repeatability (Std. Dev. δ)≤0.01°
Sample Transmittance Requirement≥10%
Power Supply220 V ±22 V, 50 Hz ±1 Hz, 150 W
Dimensions (L×W×H)605 × 320 × 220 mm
Net Weight26 kg
Temperature ControlNone
DisplayAnalog scale dial (no digital readout)
Standard Cells100 mm and 200 mm path-length glass tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYidian Woguang (YDWG)
OriginShanghai, China
ModelWZZ-3
Product TypeAutomatic Polarimeter
Temperature ControlNot temperature-controlled
DisplayDigital LCD touchscreen
Light SourceLED with 589 nm interference filter (sodium D-line equivalent)
Measurement Range±45° (optical rotation), ±120°Z (saccharimetric scale)
Minimum Resolution0.001° (optical rotation), 0.001°Z
Accuracy±(0.01 + 0.05% of reading)° (optical rotation)
Repeatability (std. dev. δ)≤0.003°
Sample Transmittance Requirement≥10%
InterfaceUSB & RS232
Power Supply220 V ±10%, 50 Hz ±1 Hz, 150 W
Dimensions (L×W×H)605 × 370 × 260 mm
Net Weight21 kg
Accuracy Class0.05
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelWZZ-2S
Product TypeAutomatic Polarimeter
Temperature ControlNone
DisplayBacklit LCD (5-inch)
Light SourceLED with Interference Filter (589 nm)
Measurement Range±45° (optical rotation), ±120°Z (saccharimetric scale)
Minimum Resolution0.001° (optical rotation), 0.01°Z (sugar scale)
Accuracy±(0.01 + 0.05% of reading)° (optical rotation), ±(0.03 + 0.05% of reading)°Z (sugar scale)
Repeatability (Std. Dev. δ)≤0.002°
Data StorageUp to 3 measurements with auto-averaging
InterfaceOptional dedicated thermal printer (RD-TH32 SC)
Power Supply220 V ± 22 V, 50 Hz ± 1 Hz, 150 W
Dimensions605 × 370 × 260 mm
Net Weight21 kg
Accuracy Class0.05
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelSGW®-568
Product TypeAutomated Polarimeter
Temperature ControlPeltier-based, 10–50 °C (±0.2 °C accuracy)
Display8-inch color touch LCD
Light SourceLED with precision interference filter (589 nm, Na D-line)
Measurement Range±90° (optical rotation), ±259°Z (saccharimetric scale)
Minimum Resolution0.0001°
Accuracy±0.003°
Repeatability (SD)≤0.002°
Zero Repeatability0.0005°
Response Speed8°/s (full-scale)
Avg. Measurement Time26 s (6 measurements)
Sample Transmittance Limit≥0.01%
CalibrationMulti-point automatic calibration
Data Storage16 GB internal
ConnectivityUSB, VGA, Ethernet, optional Wi-Fi & thermal printer
Standard Cells100 mm and 200 mm pathlength (ambient & thermostatted)
ComplianceJJG 536–2015 Class 0.01, supports 21 CFR Part 11 audit trail (optional upgrade), GLP/GMP-ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelSGW®-533
Product TypeAutomatic Polarimeter
Temperature ControlPeltier-integrated, 10–50 °C (±0.2 °C accuracy)
Display8-inch color touch LCD
Light SourceLED (589 nm, Na D-line equivalent) with precision interference filter
Measurement Range±90° (optical rotation), ±259°Z (saccharimetric scale)
Minimum Resolution0.001°
Accuracy±0.004°
Repeatability (SD)≤0.002°
Zero Repeatability0.001°
Response Speed8°/s (full-scale)
Average Measurement Time26 s (6 measurements)
Sample Transmittance Limit≥0.05%
Data Storage16 GB internal
User Management4-tier password hierarchy, up to 500 users
Electronic Signatures & Audit TrailCompliant with FDA 21 CFR Part 11 requirements
Predefined Methods1000 user-configurable protocols
ConnectivityUSB, VGA, Ethernet, optional Wi-Fi & thermal printer
Standard Cells100 mm and 200 mm pathlength (ambient & thermostatted)
Dimensions702 × 376 × 240 mm
Net Weight21 kg
ComplianceJJG 536–2015 Class 0.01, USP <781>, EP 2.2.7, ISO 13871, GLP/GMP-ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYDWG
OriginShanghai, China
ModelSGW®-537
Product TypeAutomated Polarimeter
Temperature ControlPeltier-integrated (10–50 °C, ±0.2 °C accuracy)
Display8-inch color TFT touchscreen
Light Source20 W halogen lamp
Standard Wavelengths546 nm, 589 nm
Optional Wavelengths365, 405, 436, 578, 633 nm (7 total)
Measurement Range±90° (optical rotation), ±259°Z (saccharimetric scale)
Minimum Resolution0.001°
Accuracy±0.004°
Repeatability (σ)≤0.002°
Zero repeatability0.001°
Response Speed8°/s (full scale)
Avg. Measurement Time26 s (6 measurements)
Sample Transmittance Limit≥0.1%
Data Storage16 GB internal
Compliance OptionsFDA 21 CFR Part 11 audit trail software (optional), GMP/GLP-ready configuration
OSWindows-based, LIMS-compatible
InterfacesUSB, VGA, Ethernet, optional Wi-Fi & thermal printer
Standard Cells100 mm / 200 mm pathlength (ambient & thermostatted)
Dimensions702 × 376 × 240 mm
Net Weight21 kg
CalibrationMulti-point automatic calibration
Regulatory ConformanceJJG 536–2015 Class 0.01