Empowering Scientific Discovery

HORIBA (China) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelPartica CENTRIFUGE CN-300
Measurement PrincipleCentrifugal Sedimentation
Measured Range10 nm – 40 µm
Maximum Centrifugal Force30,000 × g
Temperature ControlIntegrated Peltier Cooling for Sample Cell and Rotor
Measurement ModesDensity Gradient Mode & Homogeneous Mode
Sample VolumeAs low as 2 µL (undiluted) or 10 µL (diluted)
ComplianceIEC 61010-1:2010 / IEC 61010-2-020:2016
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
Manufacturer TypeManufacturer
Origin CategoryImported
ModelLA-960 V2
Dispersion MethodDry & Wet Dispersion
Measurement Range10 nm – 5000 µm
Repeatability±0.1%
Measurement Time10 seconds
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelSZ-100 V2
Dispersion MethodWet Dispersion
Instrument TypeLaboratory Laser-Based Particle Characterization System
Size Range0.3 nm – 10 µm
Reproducibility±2%
Measurement Time< 2 min
Zeta Potential Range−500 mV to +500 mV
Molecular Weight Range1,000 – 2×10⁷ Da
Detection Angles90° and 173° (automatically or manually selectable)
Sample Volume12 µL – 1,000 µL
Measurement Principle for SizeDynamic Light Scattering (DLS), also known as Photon Correlation Spectroscopy (PCS)
Zeta Potential PrincipleLaser Doppler Electrophoresis
Molecular Weight DeterminationDebye Plot Analysis
Second Virial Coefficient (A₂)Yes
Integrated Auto-TitratorYes (for pH-controlled zeta potential studies)
ComplianceNIST-traceable calibration with 100 nm standard particles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelViewSizer 3000
PricingUpon Request
Dispersion MethodWet Dispersion
Measurement Range10 nm – 15 µm
RepeatabilityNot Specified
Measurement Time6 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelSA-9650
Instrument TypeSpecific Surface Area Analyzer
Measurement PrincipleDynamic Flow Method (Gas Adsorption)
Number of Analysis Stations1–3
Specific Surface Area Range0.10 to >2000 m²/g
RepeatabilityRSD < 1%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelLA-350
Dispersion MethodWet Dispersion
Measurement Range100 nm – 1000 µm
Repeatability<1% RSD
Measurement Time10 s
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0