| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LabRAM Soleil™ |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–2100 nm |
| Spectral Resolution | 0.5 cm⁻¹ |
| Spatial Resolution | <250 nm |
| Minimum Wavenumber | <5 cm⁻¹ |
| Spectral Reproducibility | Better than ±0.01 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | RZ-660 |
| Price | Upon Request |
| Spectral Range | 680 – 3,800 cm⁻¹ |
| Spatial Resolution | < 5 µm |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | XploRA Nano |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated Atomic Force Microscopy |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution (TERS mode) | <10 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | <0.1 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | OEM Customizable Spectrometer |
| Price | Upon Request |
| Spectral Range | 190–2100 nm |
| Optical Resolution | 10–1 nm (FWHM, configurable per design) |
| Focal Length | 20–140 mm |
| Detector Options | Single-channel PMT, Linear/2D CCD, CMOS, InGaAs, NMOS, PDA arrays |
| Optical Design | Monolithic Czerny–Turner or Crossed-beam configuration with Aberration-Corrected (Type-4) holographic grating |
| Compliance | Designed for integration into ISO/IEC 17025-accredited analytical systems, compatible with FDA 21 CFR Part 11–ready software environments |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EV 2.0 |
| Detector Type | CCD |
| Spectral Range | 200–1050 nm |
| Dynamic Range | >3000:1 |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | HCLUE |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | VS7000+ |
| Detector Type | Back-Illuminated CCD |
| Spectral Range | 200 nm – 1050 nm |
| Spectral Resolution (UV-Vis) | 2.7 nm @ 75 µm slit, 2048-pixel array |
| Numerical Aperture | f/2.8 |
| Stray Light Suppression | ≤ 0.08% (max) |
| Dynamic Range | 7000:1 |
| Quantum Efficiency | >65% at 250 nm, >70% at 650 nm, >55% at 850 nm |
| Readout Speed | up to 223 spectra/s (ultra-fast mode, zero exposure) |
| A/D Conversion | 16-bit, 500 kHz |
| Dark Current | 2.8 counts/ms @ 20°C |
| Read Noise | ≤45 e⁻ (sensitive mode), ≤90 e⁻ (high full-well mode) |
| Linearity Error (factory corrected) | <0.4% (sensitive mode), <0.8% (high full-well mode) |
| On-board Linearization & Wavelength Calibration | Yes |
| Interface | USB 2.0 |
| Optical Design | Monolithic aberration-corrected Czerny–Turner with Type-4 flat-field concave holographic grating |
| Compliance | CE, RoHS, ISO 9001-manufactured |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | NanoLog® |
| Dispersion Element | Grating |
| Slit (Spectral Bandpass) | Not Specified |
| Resolution | Not Specified |
| Sensitivity | Not Specified |
| Wavelength Accuracy | Not Specified |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Ultima Expert |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | ≤1% |
| Long-Term Stability (RSD) | ≤2% |
| Wavelength Range | 160–800 nm |
| Optical Resolution | ≤0.005 nm at 200 nm (Constant Resolution Across Full Range) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | iHR320 / iHR550 |
| Application System | Universal |
| Grating Mount | Dual-grating turret (motorized, selectable) |
| Spectral Resolution | 0.06 nm (iHR320), 0.025 nm (iHR550) |
| Linear Dispersion | 2.31 nm/mm (iHR320), 1.34 nm/mm (iHR550) |
| Wavelength Range | 150 nm – 40 µm |
| F-number | f/4.1 (iHR320), f/6.4 (iHR550) |
| Wavelength Accuracy | ±0.20 nm |
| Stray Light | 1.5 × 10⁻⁴ (iHR320), 1.0 × 10⁻⁵ (iHR550) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MicroHR |
| Price | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | H1034 (Single-Stage) |
| Grating Mount | Motorized 3-Grating Turret |
| Spectral Resolution | ≤5 nm (with 100 µm slit) |
| Wavelength Range | 200–1200 nm (optional blaze wavelengths: 250 nm, 350 nm, 500 nm) |
| F-number | F/2.8 |
| Stray Light | < 0.1% (typical) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | H1034 (Dual-Stage) |
| Grating Configuration | Dual Grating |
| Spectral Resolution | ≤5 nm (with 100 µm slit) |
| Wavelength Range | 200–1200 nm (optional blaze wavelengths: 250 nm, 350 nm, 500 nm) |
| F/# | F/2.8 |
| Stray Light | < 0.1% (typical) |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DeltaFlex |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | Adjustable from 1 to 64 nm |
| Optical Resolution | 1 nm |
| Detection Sensitivity | Single-Photon Counting |
| Wavelength Accuracy | ±1 nm |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | XploRA PLUS |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | Lateral 0.4 µm, Axial 1.5 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.03 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Aqualog® |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 5 nm |
| Optical Resolution | 0.58 nm |
| Sensitivity | 20,000:1 (SNR, RMS, water Raman at 350 nm excitation, 30 s integration) |
| Wavelength Accuracy | ±1.0 nm |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | InverTau |
| Pricing | Upon Request |
| Dispersive Element | Filter-Based |
| Resolution | 4096 × 4096 |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Series | VS20 |
| Resolution | ≤6.5 nm (with 50 µm slit) |
| Stray Light | <0.25% @ 260 nm, <0.1% @ 400 nm, <0.2% @ 600 nm |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Flex-CLUE |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FHR1000 |
| Application System | Universal |
| Grating Mount | Dual-Grating Turret |
| Spectral Resolution | 0.010 nm |
| Dispersion | 0.8 nm/mm |
| F-number | f/9.0 |
| Focal Length | 1000 mm |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.015 nm |
| Maximum Scanning Speed | >300 nm/s |
| Grating Dimensions | Single grating: 110 mm × 110 mm |
| Dual-grating configuration | 80 mm × 110 mm each |
| Stray Light | <1×10⁻⁶ (typical, per ISO 14785) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MacroRAM |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 100–3400 cm⁻¹ |
| Spectral Resolution | 8 cm⁻¹ at 914.9 nm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Repeatability | ≤ ±0.03 cm⁻¹ |
| Excitation Wavelength | 785 nm |
| Max Laser Power | 450 mW (software-controllable, continuous variable) |
| Detector | Back-Thinned CCD, cooled to –50 °C, 80% QE at 800 nm |
| Dark Current | 0.05 e⁻/pixel/sec at –50 °C |
| Dynamic Range | 42,550:1 |
| Fiber Input | 100 µm core diameter, female FC/PC connector, NA = 0.15 |
| Dimensions (W × D × H) | 432 × 432 × 381 mm (17 × 17 × 15 in) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | HE |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 100–3200 cm⁻¹ |
| Spectral Resolution | 3 cm⁻¹ |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | < 0.25 cm⁻¹ |
| Detector | 1024 × 256-pixel CCD (MPP mode) |
| Cooling | Peltier-cooled to –70 °C (air-cooled, no water required) |
| Read Noise | < 8 e⁻/pixel |
| Dark Current | < 0.01 e⁻/pixel/s |
| Laser Options | 532 nm, 633 nm, or 785 nm (output power 80–300+ mW) |
| Fiber Probe Support | Up to 4 simultaneous SuperHead™ probes |
| Optical Configurations | Standard, confocal, immersion, or microscope-coupled via 40 mm, 10×, or 50× long-working-distance objectives |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Fluorolog-QM |
| Wavelength Range | 180–5500 nm |
| Spectral Resolution | < ±0.1 nm |
| Sensitivity | > 35,000:1 (Water Raman S/N) |
| Wavelength Accuracy | < ±0.1 nm |
| Monochromator Type | Reflective Czerny-Turner |
| Focal Length | 350 mm (single stage), 700 mm (dual stage) |
| Stray Light Rejection | 1×10⁻⁵ (single), 1×10⁻¹⁰ (dual) |
| Grating Options | >30 selectable gratings |
| Slit Control | Motorized, step resolution down to 0.01 nm |
| Light Sources | Up to 4 simultaneously controlled (Xe arc, pulsed LEDs, lasers, OPOs) |
| Detectors | Up to 6 concurrently addressable (PMT, NIR PMT, InGaAs, InAs, InSb) |
| Lifetime Techniques | TCSPC (5 ps – ∞), MCS, SSTD (1 µs – seconds), gated detection |
| Software Platform | FelixFL v5.x with FDA 21 CFR Part 11 compliance mode |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | LabRAM Odyssey |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 200–2100 nm |
| Spectral Resolution | 0.35–0.65 cm⁻¹ |
| Spatial Resolution | down to 250 nm |
| Minimum Wavenumber | as low as 3.5 cm⁻¹ |
| Spectral Reproducibility | ±0.02 cm⁻¹ |