| Brand | PerkinElmer |
|---|---|
| Model | Avio 550 |
| Origin | Imported |
| Configuration | Refurbished Unit |
| Dimensions (W×D×H) | 76 × 84 × 87 cm |
| Plasma Observation | Dual-view (Axial and Radial) |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) |
| Nebulization System | 4-channel, 12-roller peristaltic pump |
| Plasma Torch Design | Vertical, tool-free, maintenance-free torch with integrated tail-flame cutoff |
| Argon Consumption | Ultra-low |
| Diagnostic Capability | Real-time plasma imaging via integrated color plasma camera |
| Data Acquisition | Universal Data Acquisition (UDA) — full-wavelength, simultaneous, time-resolved detection |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Avio 550/560 |
| Pricing | Upon Request |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Plasma Configuration | Dual-View (Axial and Radial) |
| Detection Technology | Solid-State CCD Detector Array |
| Gas Consumption | Ultra-Low Argon Flow (<10 L/min typical plasma gas) |
| Torch Design | Vertical, Tool-Free, Maintenance-Free Plasma Torch with Integrated Tail-Flame Suppression |
| Optical System | Flat-Field Echelle Spectrometer with UV-Visible Wavelength Coverage (165–900 nm) |
| Pump System | 4-Channel, 12-Roller Peristaltic Pump |
| Dimensions (W×D×H) | 76 × 84 × 87 cm |
| Camera Integration | Integrated Color Plasma Torch Imaging System for Real-Time Torch & Injector Monitoring |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Avio® 550 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Plasma Orientation | Vertical Torch Configuration |
| Software Platform | Syngistix™ for ICP |
| Sample Introduction System | Scott/Cross-Flow Nebulizer with Cyclonic Spray Chamber |
| Optional Capability | HF-Compatible Sample Handling |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 7000 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Distribution Channel | Authorized Third-Party Reseller |
| Import Status | Imported Instrument |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 5300DV |
| Instrument Type | Simultaneous (Multi-Channel) ICP-OES |
| Detection Limit (Zn at 213.856 nm) | ≤0.003 µg/L |
| Precision (RSD) | ≤1.5% |
| Long-Term Stability (4-hr drift) | ≤2.0% |
| Wavelength Range | 165–870 nm |
| Optical Resolution (FWHM) | ≤0.007 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Optima 8000 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | 1 ppm |
| Precision (RSD) | ≤1.5% |
| Short-Term Stability (1 hr) | RSD <1% |
| Long-Term Stability (4 hr) | RSD <2% |
| Wavelength Range | 160–900 nm |
| Optical Resolution | ≤0.003 nm (pixel resolution at 200 nm) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Optima 8300 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Wavelength Range | 167–782 nm |
| Optical Resolution | 0.006 nm at 200 nm |
| Configuration | Used (Refurbished & Verified) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICPE-9800 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Argon Purity Requirement | ≥99.95% |
| Minimum Argon Flow (Eco Mode) | 5 L/min |
| UV Spectral Range | 165–190 nm |
| Optical System | Two-Dimensional Cross-Dispersion with Sealed Vacuum Chamber |
| Detector | High-Resolution Megapixel CCD |
| Torch Configuration | Vertical Dual-View Design |
| Software Platform | ICPESolution v3.x with Automatic Interference-Free Wavelength Selection |
| Brand | SHINE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | Sub-ppb to low-ppb range |
| Precision (RSD) | ≤0.5% (short-term) |
| Wavelength Range | 180–800 nm (2400 grooves/mm grating) / 190–500 nm (3600 grooves/mm grating) |
| Optical Resolution | 0.004 nm (2400 L/mm) / 0.002 nm (3600 L/mm) |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | ICP 2060T (Petrochemical-Optimized) |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | 0.5–10 ppb |
| Precision (RSD) | ≤1.5% |
| Long-Term Stability (2 h) | ≤2.0% |
| Wavelength Range | 190–500 nm (with 3600 l/mm grating) |
| Optical Resolution | ≤0.008 nm |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Domestic |
| Model | ICP-3000 |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limits | Zn 213.856 nm: 0.47 µg/L |
| Ni 231.604 nm | 1.73 µg/L |
| Mn 257.61 nm | 0.18 µg/L |
| Cr 267.716 nm | 1.18 µg/L |
| Cu 324.754 nm | 1.1 µg/L |
| Ba 445.403 nm | 0.1 µg/L |
| Precision (RSD) | <0.5% |
| Long-Term Stability (2 h RSD) | <1.0% |
| Wavelength Range | 165–900 nm |
| Optical Resolution | 6.8 pm @ 200 nm |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | ICP2060T |
| Price Range | USD 70,000 – 100,000 |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | 1–10 µg/L (ppb) for most elements |
| Precision (Short-Term) | RSD < 0.5% |
| Stability (2-hr) | RSD < 1.0% |
| Wavelength Range | 165–900 nm |
| Optical Resolution | < 0.0068 nm @ 200 nm |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | ICP 3200 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Power Supply | Frequency-Convertible RF Generator |
| Optical Configuration | Dual-View (Axial & Radial) Simultaneous Observation |
| Spectral Coverage | 165–900 nm |
| Detector | Back-Illuminated CCD with Deep Depletion Technology |
| Resolution | ≤0.007 nm at 200 nm |
| Wavelength Calibration | Automated 2D Spatial Mapping Algorithm |
| Software Compliance | Supports Audit Trail, User Access Levels, and Electronic Signature per FDA 21 CFR Part 11 Requirements |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OES8000S |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | ≤0.001 wt% |
| Repeatability | ≤1.5% RSD |
| Stability | ≤1.2% RSD |
| Wavelength Range | 140–680 nm |
| Optical Resolution | 10 pm |
| Spectrometer Design | Paschen-Runge mounting with 400 mm Rowland circle diameter |
| Grating | 3600 lines/mm concave holographic grating |
| Detector | High-performance linear CMOS array |
| Excitation Source | Fully digital plasma spark source with HEPS (High-Energy Pre-Spark) technology |
| Analysis Time | <40 s per sample |
| Argon Consumption | Optimized low-flow gas system |
| Operating Temperature | 15–30 °C |
| Relative Humidity | ≤70% RH |
| Power Requirement | 220 V ±5%, 50 Hz, single-phase, ground resistance <1 Ω |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SPEC Pro 6000 |
| Instrument Type | Full-Spectrum Simultaneous Readout |
| Safety Integration | Integrated Glovebox System |
| RF Generator Architecture | Separated Solid-State RF Source |
| Optical System | Echelle Grating with Thermally Stabilized Optics |
| Detector | Back-Illuminated High-Speed CCD with Anti-Blooming Design |
| RF Power Range | 700–1600 W (Continuously Adjustable) |
| RF Cooling | Water-Cooled |
| Power Stability | <0.1% |
| Gas Control | Multi-Channel Digital Mass Flow Controllers (Accuracy: ±0.01 L/min) |
| Nebulization System | 12-Rotor, 4-Channel Peristaltic Pump with Optional Internal Standard/Standard Addition Capability |
| Torch Design | Modular, Self-Aligning, Center-Tube-Replaceable Echelle Torch |
| Software Platform | Element V (Fully Localized Chinese Interface with GLP-Compliant Audit Trail) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | ARCOS |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Sub-ppb to ppm |
| Precision (RSD) | ≤1% |
| Long-Term Stability (Drift) | ≤0.1% |
| Wavelength Range | 130–770 nm |
| Optical Resolution | ≤0.008 nm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | New SPECTRO ARCOS |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | <1 ppb |
| Precision (RSD) | 0.5% |
| Long-Term Stability | 1% |
| Wavelength Range | 130–770 nm |
| Optical Resolution | <8.5 pm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPECTRO ARCOS |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | Sub-ppb to ppm |
| Repeatability | ≤1% RSD |
| Long-Term Stability | ≤0.1% RSD |
| Wavelength Range | 130–770 nm |
| Optical Resolution | ≤0.008 nm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO GENESIS |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Optical Detection | Dual-View Vertical Torch Configuration |
| Cooling | Air-Cooled Only |
| Purge Gas Flow | As Low as 0.5 L/min |
| Linear Dynamic Range | Sub-ppb to Percent Level |
| Sample Throughput | Up to 700 Samples per Day |
| Optical Architecture | DSOI (Dual-Spectrometer Optimized Imaging) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO GENESIS |
| Type | Full-Spectrum Simultaneous ICP-OES |
| Wavelength Range | 175–770 nm |
| RF Generator | 27 MHz Solid-State |
| Optical Purge Flow | ≥0.5 L/min (Argon or Nitrogen) |
| Sample Throughput | Up to 700 samples/day |
| Detector | High-Quantum-Efficiency CCD Array |
| Compliance | ASTM D5185, D6595, ISO 11885, USP <233>, EPA Methods 200.7, 6010D, 6020B, GLP/GMP-ready with 21 CFR Part 11–compliant software options |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | GENESIS |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | ppb–ppm |
| Repeatability | ≤0.2% |
| Stability | ≤0.2% |
| Wavelength Range | 130–770 nm |
| Optical Resolution | 1 pm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | GREEN |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | sub-ppb |
| Precision (RSD) | <1.5% |
| Stability (RSD) | <1.5% |
| Wavelength Range | 165–770 nm |
| Optical Resolution | <0.008 nm across full spectrum |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpectrOil 100 |
| Pricing | Available Upon Request |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPECTROGREEN |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Sub-ppb |
| Precision (RSD) | <1.5% |
| Long-Term Stability (RSD) | <0.5% |
| Wavelength Range | 165–770 nm |
| Optical Resolution | 0.007 nm |
| Brand | SpectrUM / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Model | EXPEC 6000 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | Not Specified |
| Long-Term Stability | Not Specified |
| Wavelength Range | Not Specified |
| Optical Resolution | Not Specified |
| Brand | Supernova / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EXPEC 6500 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | <1% @ 8 h |
| Wavelength Range | 160–900 nm |
| Optical Resolution | Not Specified |
| RF Power Range | 500–1600 W (Digital Self-Excited Solid-State Generator) |
| Observation Mode | Dual-View Vertical Torch (Axial & Radial) |
| Detector | Custom Large-Area E-CCD |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy DC Arc |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Repeatability | ≤1.5% RSD |
| Stability | ≤2% RSD |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm (at 200 nm) |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Precision (RSD) | ≤1.5% |
| Stability (Drift) | ≤2% |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy Plus |
| Instrument Type | Full-Spectrum Direct-Reading ICP Optical Emission Spectrometer |
| Detection Limit (Zn @ 213.856 nm) | < 0.1 µg/L |
| Precision (RSD) | ≤ 0.5% |
| Long-Term Stability (RSD, 4h) | ≤ 1.0% |
| Wavelength Range | 130–1100 nm |
| Optical Resolution | 0.005 nm @ 200 nm |
| Detector | Custom 28 × 28 mm CMOS sensor with 3.38 million effective pixels |
| Readout Speed | >10× faster than conventional CID/CCD detectors |