Industrial Process Control Instruments
Filter
Showing 271–300 of 490 results
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ALT-1 Online Titration Analyzer for Lithium Battery Manufacturing |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ALT-1 |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH, 10 °C min (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV), pH: 0.001 pH (0–20 pH), Photometric: 0.003 Abs (0–1 Abs) |
| IP Rating | IP55/IP65 (when enclosure door is closed and latched) |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Type | Domestic |
| Model | ALT-1-C Online |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ALT-SED |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | ALT-SED |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PI-200-I |
| Pricing | Upon Request |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | HK-5100 |
| Pricing | Upon Request |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-5500 |
| Pricing | Upon Request |
| Heat Exchanger Area | 2 × 15–2 × 30 m² |
| Deionized Water Tank Volume | 2 m³ |
| Pump Configuration | Dual (1 active + 1 standby), H-(30–65)-30-2002, 2 × (5.5–7.5) kW |
| DI Water Flow Rate | 10–40 t/h |
| DI Water Outlet Temperature | ≤33 °C |
| DI Water Outlet Pressure | 0.2–0.6 MPa |
| Industrial Cooling Water Inlet Flow | 15–60 t/h |
| Industrial Water Inlet Temp | ≤33 °C |
| Industrial Water Inlet Pressure | 0.2–0.6 MPa |
| Power Supply | 380 VAC, 50 Hz |
| Dimensions (L×W×H) | 3200 × 2000 × 2300 mm |
| Weight | 3.2 t |
| Construction Material | AISI 304 stainless steel for all wetted parts |
| Heat Exchanger Type | Weld-free gasketed plate heat exchanger |
| Control Features | Low/high level alarms, dry-run protection, auto-refill solenoid valve, dual-pump redundancy |
| Brand | Junfang Lihua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HXPQX-2020 |
| Price Range | USD 28,000–42,500 |
| Internal Volume | 0.60 m³ |
| Cross-Sectional Dimensions | 400 × 300 mm |
| Tunnel Length (Centerline) | 1850 mm |
| Temperature Range (High Temp Test) | 50–70 °C ±2 °C |
| Temperature Range (Low Temp Test) | 0–−40 °C ±2 °C |
| Humidity Range (Steady-State Damp Heat) | 93 %RH ±3 %RH at 40 °C ±2 °C |
| Air Velocity Range | 0–6.5 m/s ±0.2 m/s |
| Rotational Step | 45° per increment |
| Temp Measurement Accuracy | ±0.5 °C (Resolution ≤0.1 °C) |
| RH Measurement Accuracy | ±0.5 %RH (Resolution ≤0.1 %RH) |
| Air Velocity Measurement | 0.2–10 m/s, ±5 % error (Resolution ≤0.1 m/s) |
| Heating Rate | ≤1 °C/min |
| Cooling Rate | 0.5–1 °C/min |
| Humidification Rate | ≤5 %RH/min |
| Dehumidification Rate | ≤1 °C/min |
| Brand | Hydramotion |
|---|---|
| Origin | United Kingdom |
| Model | XL7 |
| Measurement Range | 0–10 cP |
| Accuracy | ±1% of reading |
| Temperature Range | −50 to +400 °C |
| Pressure Rating | 700 bar |
| Sensor Repeatability | ±0.3% |
| Process Connections | Customizable flanged, threaded, or sanitary clamp interfaces |
| Wetted Materials | Super Duplex Stainless Steel (S32750 / UNS S32750, marketed as SAR2507) |
| Sensor IP Rating | IP67 |
| Transmitter IP Rating | IP65 |
| Safety Certifications | ATEX II 2G Ex ia IIC T1–T6 Ga, IECEx Ex ia IIC T1–T6, UKCA, CE, ISO 9001 certified |
| Electrical Supply | 24 VDC ±10%, 150 mA max |
| Analog Outputs | Three isolated 4–20 mA outputs (e.g., dynamic viscosity, intrinsic viscosity, temperature-compensated viscosity) |
| Digital Interfaces | RS485 Modbus RTU, USB for configuration and diagnostics |
| Alarm Outputs | Two voltage-free relay contacts (SPST, 250 VAC/30 VDC, 2 A) |
| Dimensions (Transmitter) | 200 × 120 × 90 mm |
| Enclosure Material | Polycarbonate (UL94 V-0 rated) |
| Weight | 920 g |
| Brand | Hydramotion |
|---|---|
| Origin | United Kingdom |
| Model | XL7-HT |
| Temperature Range (HT) | –50 °C to +400+ °C |
| Viscosity Range | 0–1 mPa·s to 0–10⁹ mPa·s |
| Accuracy | ±1% of reading or ±1 digit |
| Repeatability | ±0.3% of reading or ±1 digit |
| Measurement Interval | 1 s |
| Process Connection | Customizable (flanged, threaded, sanitary clamp) |
| Electrical Output | 4–20 mA analog + digital serial (RS-485/Modbus RTU) |
| Intrinsically Safe Certification | ATEX 2014/34/EU, IECEx Ex ia IIC T1–T6 Ga, Ex ia IIIC T135 °C Da, UL Class I Div 1 Groups A–D |
| Enclosure Rating | IP67 |
| Max Cable Length | 1000 m |
| Sensor Material Standard | SS316 (EN 1.4401) / SS316L (EN 1.4404) |
| Optional Materials | Alloy C22 (EN 2.4602), Alloy C276 (EN 2.4819), S32750 Duplex (EN 1.4410) |
| Software | ViscoLink PC-based data acquisition & logging |
| Brand | Hydramotion |
|---|---|
| Origin | United Kingdom |
| Model | XL7-LR |
| Measurement Range | 0–1 cP to 0–10⁹ cP |
| Accuracy | ±1% of reading or ±1 digit |
| Repeatability | ±0.3% of reading or ±1 digit |
| Response Time | 1 second |
| Temperature Range (Standard) | −50°C to +150°C |
| HT Option | −50°C to +400°C |
| Pressure Rating | Standard process-rated fittings |
| Process Connections | Tri-clamp, RJT, IDF, DIN, SMS, Varivent®, NPT, BSPP, custom flanges |
| Electrical Interface | Digital intrinsically safe (IS) output |
| Enclosure Rating | IP67 |
| Wetted Materials | Standard 316/316L stainless steel (EN 1.4401 / 1.4404) |
| optional alloys | Alloy C22 (EN 2.4602), Alloy C276 (EN 2.4819), S32750 duplex (EN 1.4410) |
| Surface Finish | Ra < 0.4 µm (electropolished standard) |
| CIP Compatibility | Fully compatible |
| Hazardous Area Certification | ATEX 2014/34/EU, IECEx Ex ia IIC T1–T6 Ga, Ex ia IIIC T135°C Da, UL/cUL Class I Div 1 Groups A–D, IS certified for Zone 0 |
| Brand | Instrulink |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 3.101.0000 |
| Pricing | Upon Request |
| Brand | iTEST17 |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ACM-LBRIX02 |
| Price Range | USD 4,200 – 7,000 |
| Brix Range Options | 0.00–35.00%, 0.00–80.00%, or 0.00–100.00% (selectable) |
| Accuracy Options | ±0.5%, ±0.1%, or ±0.05% Brix (selectable) |
| Operating Temperature | up to 100 °C |
| Max Process Pressure | 1.0 MPa |
| Temp Measurement Range | 0–100 °C |
| Process Temp Tolerance | −30 to +150 °C |
| Auto Temp Compensation Range | 5–100 °C |
| Wetted Materials | SUS 316L stainless steel & sapphire optical interface |
| Installation | Clamp, flange, or threaded |
| Output Signals | 4–20 mA, 0–10 V, relay, RS485 (Modbus RTU) |
| Display | High-resolution touchscreen HMI |
| Control Logic | Integrated PID, high/low limit control, programmable cleaning cycles, alarm logic, data logging with power-fail retention |
| Power Supply | 110/220 VAC, 50/60 Hz, ≤100 W |
| Ambient Operating Temp | 0–50 °C |
| Brand | Itioture |
|---|---|
| Model | ACDR-B85 |
| Measurement Range | Brix 0–85%, Temperature 0–60°C |
| Accuracy | ±0.1% Brix |
| Resolution | 0.01% Brix |
| Output | 4–20 mA (concentration), RS485 Modbus RTU |
| Power Supply | DC 24 V, 5 VA |
| Pressure Rating | 1.5 MPa (max) |
| Temperature Limit | 100°C (process fluid) |
| Enclosure Rating | IP67 |
| Installation | Clamp-type inline (standard), optional threaded or flanged mounting |
| Optional Accessories | ACL-02S pipe adapter, ACL-03S ultrasonic cleaning module |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoCon 6500C |
| Conductivity Range | 0.00–20.00 / 200.0 / 2000 µS/cm, 0.00–20.00 / 200.0 / 2000 mS/cm |
| Resistivity Range | 0.00–20.00 MΩ·cm |
| TDS Range | 0.00 ppm–200.0 ppt |
| Resolution | 0.01/0.1/1 µS/cm, 0.1/1 mS/cm, 0.01 MΩ·cm, 0.01/0.1/1 ppm, 0.1 ppt |
| Accuracy | ±1% FS |
| Temperature Sensor | Pt1000 |
| Temp. Compensation | Automatic (with ±10.0 °C offset adjustment) or Manual |
| Operating Temp. | −10.0 to +60.0 °C |
| Humidity | 10–90% RH (non-condensing) |
| Display | Backlit LCD (44×65 mm), yellow backlight |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Outputs | Two isolated 4–20 mA analog outputs (configurable, max. 600 Ω load) |
| Relay Outputs | Two independent SPST relays (Hi/Lo alarm, hysteresis adjustable |
| Enclosure Rating | IP54 |
| Mounting | Panel mount (cutout: 92×92 mm) |
| Dimensions | 96×96×130 mm |
| Weight | 0.45 kg |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoMag 300-1 |
| Body Type | Integral or Remote (S/L) |
| Pipe Size Range | DN10–DN2000 |
| Flow Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Minimum Conductivity | ≥5 µS/cm |
| Electrode Materials | 316L SS, Hastelloy C, Tantalum, Titanium, Platinum |
| Lining Materials | PTFE (DN10–DN1000), Hard Rubber (DN50–DN2000) |
| Process Temperature | PTFE: –40 to +150°C |
| Rubber | –10 to +80°C |
| Ambient Temperature | –20 to +70°C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse/Frequency, Alarm Relay |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | InnoMag 320 |
| Pricing | Available Upon Request |
| Construction Type | Integral (S-type) or Remote (L-type) |
| Nominal Diameter Range | DN10–DN2000 |
| Flow Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Display | Backlit LCD |
| Installation | Flanged (custom clamp-on option available) |
| Minimum Conductivity | ≥10 µS/cm |
| Electrode Materials | 316 Stainless Steel, Hastelloy C, Tantalum, Titanium |
| Lining Materials | PTFE (DN10–DN1000), Rubber (DN50–DN2000) |
| Housing Materials | Controller – Aluminum |
| Temperature Limits | PTFE Lining – –40 to +150 °C |
| Ambient Operating Temperature | –20 to +70 °C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse Output, Frequency Output |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoMag300 |
| Nominal Diameter Range | DN10–DN2000 |
| Flow Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Minimum Conductivity | ≥5 µS/cm |
| Electrode Materials | 316 Stainless Steel, Hastelloy C, Tantalum, Titanium |
| Lining Materials | PTFE (DN10–DN1000), Rubber (DN50–DN2000) |
| Lining Temperature Limits | PTFE: –40 to +150 °C |
| Rubber | –10 to +80 °C |
| Ambient Operating Temperature | –20 to +70 °C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse, Alarm |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Housing Material | Aluminum |
| Installation Types | Integral (S-type), Remote (L-type) |
| Bidirectional Flow Measurement | Yes |
| Pressure Loss | Negligible (no obstruction) |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoMag 300 |
| Measurement Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Minimum Conductivity | ≥5 µS/cm |
| Electrode Materials | 316 Stainless Steel, Hastelloy C, Tantalum, Titanium |
| Lining Materials | PTFE (DN10–DN1000), Rubber (DN50–DN2000) |
| Temperature Limits | PTFE Lining –40 to +150 °C |
| Ambient Temperature | –20 to +70 °C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse, Alarm |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Display | Backlit LCD |
| Installation Types | Integral (S-type), Remote (L-type) |
| Pressure Loss | Negligible (no obstruction in flow path) |
| Bidirectional Flow Measurement | Yes |
| Pipe Size Range | DN10–DN2000 |
| Brand | Junfang Lihua |
|---|---|
| Origin | Beijing, China |
| Model | HXPQX-500 |
| Internal Volume | 500 L |
| Cross-sectional Dimensions | 460 mm × 400 mm |
| Centerline Length of Wind Tunnel | 945 mm |
| Airflow Velocity Range | 0–7 m/s ±0.2 m/s (adjustable via frequency converter) |
| Preset Airflow Setpoints | 0.8, 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 6.5 m/s |
| Control Interface | 7-inch TFT touch LCD panel |
| Rotation Capability | 360° continuous |
| Power Consumption | ≤2 kW |
| Supply Voltage | 3N 380 V, 50 Hz |
| External Dimensions | 2094 mm × 568 mm × 1034 mm |
| Exhaust System | Automated gas purging |
| Communication | RS485 / RS232, MODBUS-RTU protocol, multi-channel digital output interfaces |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA 8000Plus |
| Repeatability | <1% RSD |
| Detection Limit | 0.5 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | –4 °C to 450 °C |
| Carrier Gas Requirement | Ultra-High-Purity Gases |
| Regulatory Status | Import-Class Industrial Instrument |
| Brand | KA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KA8000Ex |
| Price Range | USD 68,000–136,000 (FOB) |
| Repeatability | <1% RSD |
| Detection Limit | <1 ppb (H₂S, COS, SO₂, CH₃SH) |
| Detector Type | Enhanced Plasma Detector (EPD) |
| Column Oven Temperature Range | −5°C to 300°C |
| Carrier Gas Requirements | Argon, Helium, or Nitrogen (inert only) |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA6000 |
| Repeatability | <1% |
| Detection Limit | 1 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | −5 °C to 300 °C |
| Carrier Gases | N₂, Ar, He |
| Compliance | Fully compatible with ASTM D7622, ISO 8573-5, USP <467>, and EPA Method TO-15/TO-17 workflows |
| Software | Embedded GC control platform with 21 CFR Part 11–compliant audit trail and GLP/GMP data integrity architecture |
| Brand | Kanomax |
|---|---|
| Model | DALT6900 |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Baro Accuracy | ±2% of reading |
| Baro Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54×50×120 cm |
| Data Storage | 1000 test records |
| Display | 5-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XG-010 |
| Conductivity Range (� | S/cm): K=0.01 cm⁻¹: 0.000–2.000 & 0.00–20.00 μS/cm |
| K=0.10 cm⁻¹ | 0.00–20.00 & 0.0–200.0 μS/cm |
| K=1.00 cm⁻¹ | 0.0–200.0 & 0–2000 μS/cm |
| K=10.0 cm⁻¹ | 0–2000 & 0–20000 μS/cm |
| Temperature Range | 5–60 °C |
| Basic Accuracy | ±2.5% F.S. |
| Resolution | 0.001 μS/cm |
| Dimensions | 145 mm × 120 mm × 145 mm (L×D×H) |
| Weight | 0.63 kg |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XG09 |
| Measurement Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.02 pH |
| Temperature Compensation Range | 0.0–60.0 °C |
| Dimensions | 145 mm × 120 mm × 145 mm (L×D×H) |
| Weight | 0.63 kg |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Input Impedance | ≥10¹² Ω |
| Temperature Sensor | Pt1000 |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable, load <750 Ω) |
| Relay Outputs | 2 SPST (AC220 V/3 A or DC30 V/3 A) |
| Protection Rating | IP65 |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Data Retention Time | >10 years after power loss |
| Operating Ambient | 5–45 °C, ≤85% RH (non-condensing) |
| Storage Temperature | −25–55 °C (electrode storage >0 °C) |
| Sample Temp. Range | 5–60 °C |
| Brand | Knick |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SE 706X/1-NMSN |
| Price | Upon Request |
| Resolution | 1% + 4 ppb |
| Measurement Range | 0.00–20.00 mg/L |
| Repeatability | 1% + 4 ppb |
| Stability | ±1% of reading per month |
| Temperature Compensation Range | –5 to +135 °C |
| Communication Interface | Memosens digital interface |
| Dimensions | Ø12 × 120 mm |
| Ambient Operating Temperature | 0–80 °C |
| Brand | Knick |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SE610 |
| Pricing | Available Upon Request |
| Brand | Knick |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SE670 |
| Pricing | Available Upon Request |