| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | FOV 3000 |
| Pricing | Upon Request |
| Explosion-Proof Enclosure | FL3000 EX (316 Stainless Steel Powder-Coated) |
| Dimensions (W×D×H) | 800 × 800 × 1800 mm |
| Compressed Air Requirement | ≥0.1 MPa, 0.5 m³/h |
| Power Supply | 220 VAC, 5 kW |
| Operating Temperature Range | −10 to +45 °C |
| Explosion Protection Rating | Ex db mb px b IIC T6 Gb |
| Detectors Supported | FID, TCD, ECD, FPD, NPD, PDHID |
| Column Oven | Five-Zone Independent Temperature Control with Back-Door Rapid Cooling & Programmable Ramp |
| Carrier Gas Control | Third-Generation Fulit EPC (Electronic Pressure Control) |
| Communication Interfaces | Ethernet, 4G, Wi-Fi, RS232/RS485/RS422, 4–20 mA Analog Output |
| Software Platform | LoongOS-5.0 (Linux-based, proprietary real-time OS) |
| Data Storage | Embedded MariaDB — ≥1 year of quantitative results |
| Compliance Standards | HJ 38–2017, HJ 604–2017, HJ 1013–2018, HJ 212, FL97, Modbus/TCP, Modbus-RTU |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Accuseries Copper Ion Concentration Analyzer |
| Measurement Principle | Bathocuproine (BCO) Colorimetric Method |
| Range | 0–10 ppm Cu²⁺ |
| Optical Technology | Dual-Wavelength Photometry |
| Probe Type | Fiber-Optic Immersion Probe |
| Display | High-Resolution LCD with Dedicated Function Keypad |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs |
| Automation | Fully Automated 24/7 Operation — Auto-Calibration, Auto-Cleaning, Reagent Auto-Fill |
| System Architecture | Physically Isolated Electronic Control Unit and Sample Analysis Module |
| Maximum Flow Paths | 6 Independent Channels |
| Corrosion Resistance | IP65-rated Enclosure |
| Diagnostic Capability | Real-Time Remote Self-Diagnosis with Alarms for Sample Absence, Low Reagent Level, Flow Failure, and Optical Path Obstruction |
| Compliance | Designed for Continuous Emission Monitoring (CEM) and Process Analytical Technology (PAT) Environments |
| Software Support | Web-based Configuration Interface with Audit Trail Logging (21 CFR Part 11 Ready) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AccuSeries |
| Pricing | Upon Request |
| Display | High-resolution LCD with auxiliary programmable keypad |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC direct connection, relay outputs |
| Architecture | Modular analytical method design with field-configurable protocols |
| Diagnostics | Remote self-diagnosis with real-time alerts for sample absence, reagent level, system fault, and maintenance status |
| Automation | Fully automated 24/7 operation including auto-calibration, auto-zeroing, reagent dispensing, line flushing, and endpoint detection |
| System Isolation | Physically separated electronic control unit and wet chemistry module |
| Corrosion Resistance | IP66-rated enclosure with H₂S- and Cl₂-resistant materials |
| Electronics Design | Partitioned motherboard architecture—failure in flow control module does not interrupt main processor or DCS/PLC communication |
| Programmability | User-defined assay sequences (reagent addition order, pre-/post-measurement rinse cycles, auto-zero timing) |
| Analytical Method | On-line potentiometric titration using 0.01 N HCl standard solution with pH electrode endpoint detection |
| Range Options | 0–1 g/L or 0–0.5 g/L OH⁻ + CO₃²⁻ (chlor-alkali brine application) |
| Accuracy | ±1% of full scale |
| Linearity | ±1% of full scale |
| Repeatability | ±1% of full scale |
| Response Time | 3–12 minutes per analysis cycle |
| Operating Ambient Temperature | –20 °C to +60 °C |
| Dimensions (H×W×D) | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Requirement | 10–32 VDC or 90–240 VAC |
| Power Consumption | 100 W |
| Analog Outputs | Up to eight isolated 4–20 mA channels |
| Digital Communication | Modbus RTU (RS232/RS485), Modbus TCP/IP |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | AccuSeries |
| Measurement Principle | Potentiometric Titration (pH electrode endpoint detection) |
| Range Options | 0–1 g/L or 0–0.5 g/L (customizable per application) |
| Accuracy | ±1% of full scale |
| Linearity | ±1% of full scale |
| Repeatability | ±1% of full scale |
| Response Time | 8–12 minutes |
| Operating Temperature | –20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 300 W |
| Analog Outputs | up to eight 4–20 mA isolated channels |
| Communication Protocols | Modbus RTU (RS232/RS485), Modbus TCP/IP, USB, GUI PC direct connection |
| Relay Outputs | configurable alarm and control relays |
| Sample Streams | up to six independent flow paths (modular architecture) |
| Enclosure Rating | NEMA 4X / IP66 equivalent (corrosion-resistant, H₂S/Cl₂ tolerant, humidity resistant) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuSeries |
| Pricing | Upon Request |
| Measurement Principle | Potentiometric Titration with pH Endpoint Detection |
| Range Options | 0–1 g/L or 0–0.5 g/L (customizable per application) |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 3–12 minutes |
| Operating Temperature | –20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Consumption | 100 W |
| Supply Voltage | 10–32 VDC or 90–240 VAC |
| Analog Outputs | Up to eight 4–20 mA isolated outputs |
| Communication Protocols | Modbus RTU (RS-232/RS-485), Modbus TCP/IP, USB, GUI PC Direct Connection |
| Relay Outputs | Configurable alarm and control relays |
| Sample Streams | Up to six independent flow paths (modular expansion) |
| Enclosure Rating | IP65-rated corrosion-resistant housing |
| Compliance | Designed for hazardous area compatibility (Class I, Div 2 optional), supports GLP/GMP audit trails via software logging |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AccuSeries |
| Price | Upon Request |
| Measurement Principle | Ion-Selective Electrode (ISE) |
| Range | 0–10,000 ppb Na⁺ |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 3–12 minutes |
| Operating Temperature | −20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 100 W |
| Analog Outputs | Up to eight 4–20 mA isolated outputs |
| Communication Protocols | Modbus RTU (RS232/RS485), Modbus TCP/IP, USB, GUI direct PC connection |
| Relay Outputs | Configurable alarm and control relays |
| Sample Pathways | Up to six independent flow paths |
| Enclosure Rating | IP65-rated corrosion-resistant cabinet (H₂S/Cl₂ resistant, moisture-proof) |
| System Architecture | Physically segregated electronics and fluidic modules |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | AccuSeries1 |
| Measurement Principle | Potentiometric Acid-Base Titration with pH Endpoint Detection |
| Range Options | 0–20 mg/L or 0–500 mg/L (customizable per application) |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 8–12 minutes |
| Operating Temperature | −20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 300 W |
| Analog Outputs | up to eight 4–20 mA isolated channels |
| Communication Protocols | Modbus RTU/ASCII (RS232/RS485), Modbus TCP/IP, USB, GUI PC Direct Connection |
| Digital I/O | Relay outputs, status alarms |
| Enclosure Rating | IP65-rated corrosion-resistant housing |
| Sample Stream Capacity | Up to six independent flow paths |
| System Architecture | Physically segregated electronics and wet chemistry modules |
| Compliance | Designed for continuous operation in hazardous area-adjacent industrial environments |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ViscoSite (Nametre) |
| Price Range | USD 14,000 – 70,000 |
| Measurement Principle | Torque-based Micro-Oscillation Rheometry |
| Probe Types | LV, MV, HV, XV (XV only for VL800) |
| Viscosity Range | 0.1–5,000,000 cP (customizable beyond) |
| Calibration | NIST-traceable Newtonian fluids pre-calibrated at factory |
| Accuracy | ±1% of reading |
| Repeatability | ±0.25% of reading |
| Linearity | ±1% |
| Operating Temperature (Process) | –40 to 450 °C (with optional cooling jacket) |
| Internal Probe Temp Range | –40 to 200 °C |
| Max Flow Velocity | 2 m/s |
| Vibration Frequency | Up to 700 Hz |
| Probe Materials | 316L stainless steel, NEMA 4X-rated housing |
| Process Connection | ANSI 3" 300#, DN80 PN40 flange |
| Cable | MIL-SPEC, up to 1000 m |
| Brand | GAOMAI |
|---|---|
| Origin | Beijing, China |
| Model | GM-800 |
| Price Range | USD 14,000 – 42,500 (FOB) |
| Linearity Error | ±2% FS |
| Repeatability | <0.5% FS |
| Drift | <1% FS/7 days |
| Response Time | ≤60 s |
| Explosion Protection | Not rated |
| Sensor Type | Imported Electrochemical Oxygen Sensor |
| Output Signal | 4–20 mA DC (isolated), RS-485 Modbus RTU |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Operating Temperature | 0–45 °C |
| Enclosure Rating | IP65 |
| Calibration Interval | Recommended every 3–6 months |
| Brand | GAOMAI |
|---|---|
| Origin | Beijing, China |
| Model | GM-816 |
| Detection Limit | <5 ppb (CH₄, with DID detector) |
| Linear Dynamic Range | >10⁶ |
| Maximum Detector Capacity | 3 simultaneous detectors (e.g., DID-V, TCD, FPD, FID) |
| Column/Valve Configuration | Up to 10 columns and 5 multi-dimensional switching valves |
| Flow Control | Electronic Pressure Control (EPC) |
| Power Supply | 220 V ±10%, 2250 W |
| Connection Standard | VCR fittings for low-dead-volume gas pathways |
| Valve Oven Protection | Integrated valve box with thermal stabilization and contamination isolation |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GBDA-180 |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| Measurement Resolution | ±1.0% FS |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 3 L |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±1% FS |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Range | 0–100 kPa |
| Pressure Accuracy | ±1% FS |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 5 kW |
| Dimensions (L×W×H) | 6950 × 1800 × 650 mm |
| Weight | 1500 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBDA-180a |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| Measurement Resolution | ±1.0% FS |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 3 L |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±1% FS |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Range | 0–100 kPa |
| Pressure Accuracy | ±1% FS |
| Gas Supply Pressure | 0.2–0.8 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 5 kW |
| Dimensions (L×W×H) | 6950 × 1800 × 650 mm |
| Weight | 1500 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GBDA-180C |
| Price Range | USD 112,000–252,000 (FOB Guangzhou) |
| Mass Measurement Resolution | ±0.01 g |
| Gas Flow Rate Range | 0.01–10 L/min |
| Reactor Volume | 500 mL |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2% FS (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–200 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Gas Supply Pressure | 0.2–0.8 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 3,000 W |
| Dimensions (W×D×H) | 3600 × 810 × 1930 mm |
| Weight | 1,100 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GBDA-180I |
| Price Range | USD 112,000 – 252,000 |
| Mass Measurement Resolution | ±0.01 g |
| Gas Flow Rate Range | 0.01–10 L/min |
| Reactor Volume | 500 mL |
| Maximum Number of Reactors per System | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2% FS (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25% |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–200 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Air Supply Pressure | 0.2–0.8 MPa |
| Test Chamber Count | 18 |
| Chamber Volume | 3.5 L |
| Dimensions | 3600 × 810 × 1930 mm |
| Weight | 1100 kg |
| Power Consumption | 3000 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GBDA-180K |
| Price Range | USD 112,000 – 252,000 (based on EUR/USD exchange rate and typical export pricing) |
| Mass Measurement Resolution | ±0.01 g |
| Gas Flow Rate Range | 0.01–10 L/min |
| Reactor Volume | 500 mL |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2% FS (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–200 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Gas Supply Pressure | 0.2–0.8 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 3,000 W |
| Dimensions (W×D×H) | 3600 × 810 × 1930 mm |
| Weight | 1,100 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Equipment Co., Ltd. |
| Model | GBDA-180L |
| Measurement Resolution | ±0.01 g |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 500 mL |
| Maximum Number of Reactors per System | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2% FS (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25% |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–200 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Gas Supply Pressure | 0.2–0.8 MPa |
| Test Chamber Count | 18 |
| Chamber Volume | 3.5 L |
| Dimensions | 3600 × 810 × 1930 mm |
| Weight | 1100 kg |
| Power Consumption | 3000 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBDA-180S |
| Price Range | USD 7,000–14,000 (FOB) |
| Measurement Resolution | ±1.0% FS |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 3.5 L |
| Maximum Number of Reactors per System | 12 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2% (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–200 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Air Supply Pressure | 0.2–0.8 MPa |
| Gas Inlet Port | φ8 mm |
| Number of Test Chambers | 18 |
| Overall Dimensions | 3600 × 810 × 1930 mm |
| Weight | 1100 kg |
| Power Consumption | 3000 W |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBDA-180W |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| Mass Resolution | ±0.01 g |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 500 mL |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Range | Ambient to 80 °C (0.1 °C increment) |
| Temperature Control Accuracy | ≤ ±0.2 °C |
| Mass Detection Range | 0–4200 g |
| Power Supply | 200 V AC, 50/60 Hz |
| Max. Power Consumption | 3 kW |
| Dimensions (W×D×H) | 2700 × 560 × 1800 mm |
| Operating Environment | 5–40 °C, <60% RH |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBW-180 |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±1% FS |
| O₂ Detection Range | 0–25% |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–100 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Gas Flow Control Range | 0.01–10 L/min |
| Flow Control Accuracy | ±1.0% FS |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Reactor Volume per Chamber | 3 L |
| Max. Number of Simultaneous Reactors | 18 |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 5 kW |
| Dimensions (L×W×H) | 6950 × 1800 × 650 mm |
| Weight | 1500 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GC-4085 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | GCDH-X |
| Price | Upon Request |
| Measurement Principle | Electrochemical (Long-Life Galvanic Cell) |
| Range Options | 0–10 / 0–100 / 0–1000 ppm O₂, or 0–1% O₂ |
| Accuracy | ≤±4% FS (0–10 ppm), ≤±2% FS (0–100 ppm and 0–1000 ppm) |
| Resolution | 0.01 ppm |
| Response Time (T90) | ≤10 s |
| Sample Flow Rate | 300–500 mL/min |
| Zero Drift | ≤±1% FS/7 days |
| Span Drift | ≤±1% FS/7 days |
| Repeatability | ≤1% |
| Inlet Pressure Range | 0.05–0.5 MPa |
| Recovery Time | 60 min (from air to 1 ppm O₂) |
| Sensor Lifetime | >24 months |
| Explosion Protection | Ex ia IIC T5 |
| Weight | ~4.5 kg |
| Dimensions (L×W×H) | 255 × 250 × 160 mm |
| Power Supply | DC (rechargeable battery, ~8 h continuous operation) |
| Built-in Sample Pump | Optional |
| Temperature Compensation | Automatic |
| Sample Compatibility | H₂, He, hydrocarbons, inert gases, acid gases (e.g., CO₂), and mixed process streams |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AKTAprocess |
| Pricing | Available Upon Request |
| Flow Rate Options | 4–180 L/h, 13–600 L/h, 45–1800 L/h |
| Column Compatibility | AxiChrom® |
| UV Detection | Single-wavelength (280 nm) or Multi-wavelength |
| pH Range | 0–14 |
| Conductivity Range | 1–200 mS/cm |
| Enclosure Rating | NEMA 4X / IP56 |
| Electrical Compliance | UL 508A, EN 61010-1 |
| Max Operating Pressure | PP tubing (6 bar @ ≤40 °C) |
| Operating Temperature | Ambient 2–30 °C |
| Process Fluid | PP system 4–60 °C (3 bar max at 40–60 °C) |
| Dimensions (L×W×H) | 1205 × 850 × 1670 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8550 |
| Pricing | Available Upon Request |
| Brand | Global Water |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | WQ401 |
| Output | 4–20 mA |
| Measurement Range | 0–100% saturation / 0–8 ppm |
| Temperature Compensation Accuracy | ±0.5% |
| Max Pressure Rating | 40 psi |
| Operating Voltage | 10–36 VDC |
| Load Current | 15.5 mA + sensor output |
| Warm-up Time | 10 s |
| Operating Temperature | −40 to +55 °C |
| Membrane Material | 0.001″ FEP Teflon (standard probe) |
| Combined Measurement Error | ±2% FS |
| Probe Dimensions (Standard) | Ø32 mm × 279 mm |
| Probe Dimensions (Inline) | Ø50 mm × 305 mm |
| Weight | 454 g |
| Standard Kit | DD0000WQ401 electrode, 7.5 m cable, manual |
| Optional Accessories | WQEXC extension cable (up to 150 m), 00-740 replaceable DO membrane electrode |
| Brand | GAOMAI |
|---|---|
| Origin | Beijing, China |
| Model | GM 1900 Explosion-Proof Series |
| Explosion Protection Mark | Ex de ib mb px IIC T4 Gb |
| IP Rating | ≥IP65 |
| Positive Pressure Range | 0–2069 Pa |
| Purge Time | 0–999 min (adjustable) |
| Alarm & Cut-off Pressure | 0–2069 Pa (adjustable) |
| Cabinet Dimensions | 90 cm × 75 cm × 50 cm |
| Gas Piping | EP-grade stainless steel tubing with orbital welding or VCR fittings |
| Pre-shipment Tests | Pressure hold, leak detection, moisture analysis, oxygen analysis, particle count |
| Compliance | Certified by National Supervisory Inspection Center for Explosion-Protected Instrumentation (Cert. No.: GYB21.3140X) |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GM 902 |
| Detector Options | Electrochemical, Catalytic Bead, NDIR, TCD, PID |
| Measurement Units | ppm, mg/m³, vol%, %LEL, pphm, ppb, mg/L |
| Sampling Method | Integrated diaphragm pump with hydrophobic particulate filter and moisture trap |
| Environmental Rating | Suitable for high-humidity ambient air sampling |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | 1400 |
| Measurement Range | 0–2 ppm / 0–20 ppm / 0–200 ppm H₂O in Ar |
| Accuracy | ±0.02 ppm (0–2 ppm), ±0.25 ppm (0–20 ppm), ±2.50 ppm (0–200 ppm) |
| Response Time (t₉₀) | ≤10 s |
| Sample Flow Rate | 2 scfh (0.88 slpm) |
| Inlet/Outlet Fittings | 1/4" VCR inlet, 1/4" Swagelok outlet |
| Operating Temperature | 16–35 °C |
| Max Inlet Pressure | 10 psig |
| Detector Type | Microwave-Induced Plasma Emission Spectroscopy (MIP-ES) |
| Sensitivity | ±0.01 ppm (Model 1400-A/1402-A), ±0.10 ppm (Model 1400-B/1402-B) |
| Output | 4–20 mA analog + dry contact alarms |
| Power | 100 W, 115/230 VAC, 50/60 Hz |
| Dimensions | 13.34 × 42.23 × 37.15 cm |
| Weight | 11.3 kg |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 200DID |
| Detector Type | Helium Discharge Ionization Detector (DID) |
| Detection Limit | <5 ppb |
| Linear Dynamic Range | >10⁶ |
| Column Oven Temperature Range | +10 °C to 150 °C |
| Column Format | Micro-packed and 1/8″ packed columns |
| Flow Control | Precision Mass Flow Controllers |
| Sample Introduction | Pneumatically Actuated Gas Sampling Valve |
| Valve Configurations | Backflush, Column Selection, Heart-Cut, Series/Bypass |
| Construction Materials | Electropolished Stainless Steel with VCR Fittings |
| Operating Modes | Manual (for method development) and Fully Automated (for continuous process analysis) |
| Compliance | Designed for GLP/GMP environments |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | 20600 |
| Detection Principle | Thermal Conductivity Detection (TCD) |
| Detector Type | Sealed-reference-cell TCD with four filament elements (rhenium-tungsten, tungsten, nickel) |
| Response Time | <10 s |
| Power Supply | Rechargeable battery or AC adapter |
| Calibration | Dual-range, user-configurable for specific binary gas pairs |
| Sensitivity | Calibratable to 0.5% O₂ in air |
| Display | Integrated LCD showing direct % concentration reading |
| Sample Handling | Integrated diaphragm pump |
| Compliance | Designed for field-deployable industrial process monitoring and leak verification per ASTM D1946 and ISO 8573-5 guidelines |
| Operating Environment | Portable, ruggedized housing for ambient industrial site use |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | 210 ACE |
| Detection Principle | Hydrogen Flame Ionization Detection (FID) with High-Selectivity Gas Chromatographic Separation |
| Detection Limit | <30 ppb |
| Linear Dynamic Range | >6 orders of magnitude |
| Compliance | ISBT Standard for Acetaldehyde in Beverage-Grade CO₂ |
| Installation | Benchtop or Rack-Mountable |
| Control Interface | Front-panel keypad + optional PC-based software with audit trail capability |
| Data Output | Real-time concentration display, analog output (4–20 mA), digital logging |