Industrial Process Control Instruments
Filter
Showing 241–270 of 490 results
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuSeries |
| Pricing | Upon Request |
| Measurement Principle | Potentiometric Titration with pH Endpoint Detection |
| Range Options | 0–1 g/L or 0–0.5 g/L (customizable per application) |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 3–12 minutes |
| Operating Temperature | –20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Consumption | 100 W |
| Supply Voltage | 10–32 VDC or 90–240 VAC |
| Analog Outputs | Up to eight 4–20 mA isolated outputs |
| Communication Protocols | Modbus RTU (RS-232/RS-485), Modbus TCP/IP, USB, GUI PC Direct Connection |
| Relay Outputs | Configurable alarm and control relays |
| Sample Streams | Up to six independent flow paths (modular expansion) |
| Enclosure Rating | IP65-rated corrosion-resistant housing |
| Compliance | Designed for hazardous area compatibility (Class I, Div 2 optional), supports GLP/GMP audit trails via software logging |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AccuSeries |
| Price | Upon Request |
| Measurement Principle | Ion-Selective Electrode (ISE) |
| Range | 0–10,000 ppb Na⁺ |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 3–12 minutes |
| Operating Temperature | −20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 100 W |
| Analog Outputs | Up to eight 4–20 mA isolated outputs |
| Communication Protocols | Modbus RTU (RS232/RS485), Modbus TCP/IP, USB, GUI direct PC connection |
| Relay Outputs | Configurable alarm and control relays |
| Sample Pathways | Up to six independent flow paths |
| Enclosure Rating | IP65-rated corrosion-resistant cabinet (H₂S/Cl₂ resistant, moisture-proof) |
| System Architecture | Physically segregated electronics and fluidic modules |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | AccuSeries1 |
| Measurement Principle | Potentiometric Acid-Base Titration with pH Endpoint Detection |
| Range Options | 0–20 mg/L or 0–500 mg/L (customizable per application) |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 8–12 minutes |
| Operating Temperature | −20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 300 W |
| Analog Outputs | up to eight 4–20 mA isolated channels |
| Communication Protocols | Modbus RTU/ASCII (RS232/RS485), Modbus TCP/IP, USB, GUI PC Direct Connection |
| Digital I/O | Relay outputs, status alarms |
| Enclosure Rating | IP65-rated corrosion-resistant housing |
| Sample Stream Capacity | Up to six independent flow paths |
| System Architecture | Physically segregated electronics and wet chemistry modules |
| Compliance | Designed for continuous operation in hazardous area-adjacent industrial environments |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ViscoSite (Nametre) |
| Price Range | USD 14,000 – 70,000 |
| Measurement Principle | Torque-based Micro-Oscillation Rheometry |
| Probe Types | LV, MV, HV, XV (XV only for VL800) |
| Viscosity Range | 0.1–5,000,000 cP (customizable beyond) |
| Calibration | NIST-traceable Newtonian fluids pre-calibrated at factory |
| Accuracy | ±1% of reading |
| Repeatability | ±0.25% of reading |
| Linearity | ±1% |
| Operating Temperature (Process) | –40 to 450 °C (with optional cooling jacket) |
| Internal Probe Temp Range | –40 to 200 °C |
| Max Flow Velocity | 2 m/s |
| Vibration Frequency | Up to 700 Hz |
| Probe Materials | 316L stainless steel, NEMA 4X-rated housing |
| Process Connection | ANSI 3" 300#, DN80 PN40 flange |
| Cable | MIL-SPEC, up to 1000 m |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBDA-180a |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| Measurement Resolution | ±1.0% FS |
| Gas Flow Rate | 0.01–10 L/min |
| Reactor Volume | 3 L |
| Maximum Number of Simultaneous Reactors | 18 |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±1% FS |
| O₂ Detection Range | 0–25% vol |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Range | 0–100 kPa |
| Pressure Accuracy | ±1% FS |
| Gas Supply Pressure | 0.2–0.8 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 5 kW |
| Dimensions (L×W×H) | 6950 × 1800 × 650 mm |
| Weight | 1500 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBW-180 |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±1% FS |
| O₂ Detection Range | 0–25% |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–100 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Gas Flow Control Range | 0.01–10 L/min |
| Flow Control Accuracy | ±1.0% FS |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Reactor Volume per Chamber | 3 L |
| Max. Number of Simultaneous Reactors | 18 |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 5 kW |
| Dimensions (L×W×H) | 6950 × 1800 × 650 mm |
| Weight | 1500 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GC-4085 |
| Pricing | Upon Request |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AKTAprocess |
| Pricing | Available Upon Request |
| Flow Rate Options | 4–180 L/h, 13–600 L/h, 45–1800 L/h |
| Column Compatibility | AxiChrom® |
| UV Detection | Single-wavelength (280 nm) or Multi-wavelength |
| pH Range | 0–14 |
| Conductivity Range | 1–200 mS/cm |
| Enclosure Rating | NEMA 4X / IP56 |
| Electrical Compliance | UL 508A, EN 61010-1 |
| Max Operating Pressure | PP tubing (6 bar @ ≤40 °C) |
| Operating Temperature | Ambient 2–30 °C |
| Process Fluid | PP system 4–60 °C (3 bar max at 40–60 °C) |
| Dimensions (L×W×H) | 1205 × 850 × 1670 mm |
| Brand | Global Water |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | WQ401 |
| Output | 4–20 mA |
| Measurement Range | 0–100% saturation / 0–8 ppm |
| Temperature Compensation Accuracy | ±0.5% |
| Max Pressure Rating | 40 psi |
| Operating Voltage | 10–36 VDC |
| Load Current | 15.5 mA + sensor output |
| Warm-up Time | 10 s |
| Operating Temperature | −40 to +55 °C |
| Membrane Material | 0.001″ FEP Teflon (standard probe) |
| Combined Measurement Error | ±2% FS |
| Probe Dimensions (Standard) | Ø32 mm × 279 mm |
| Probe Dimensions (Inline) | Ø50 mm × 305 mm |
| Weight | 454 g |
| Standard Kit | DD0000WQ401 electrode, 7.5 m cable, manual |
| Optional Accessories | WQEXC extension cable (up to 150 m), 00-740 replaceable DO membrane electrode |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 210 AHC |
| Detection Limit | <30 ppb |
| Carrier Gas Flow Rate | ≈30 cc/min |
| Carrier Gas Pressure | 60 psig |
| Sample Inlet Pressure | 5 psig (max 20 psig) |
| Calibration Gas Pressure | 5 psig (max 20 psig) |
| Operating Temperature | 5–40 °C |
| Power Requirement | 400 W |
| Dimensions (W×H×D) | 42.9×31.1×58.4 cm |
| Net Weight | 23 kg |
| Mounting | 19″ EIA rack (7U) or benchtop |
| Gas Fitting | 1/8″ Swagelok |
| Analog Outputs | six 4–20 mA channels |
| Input Trigger | TTL or dry contact |
| Display | 16×2 character LED-backlit LCD (99.0×24.0 mm active area) |
| User Interface | membrane keypad (non-contact digital input) |
| Linear Range | 5–120 ppb (1×10³ dynamic range) |
| Sample Introduction | dual-solenoid automated valve system with fixed-volume sampling loop |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GOW-MAC 402 |
| Price Range | USD 1,500 – 7,500 |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 5900 DID |
| Detector Type | Discharge Ionization Detector (DID) |
| Detection Range | 1 ppb to <0.5% (v/v) |
| Carrier Gas | Helium |
| Construction | Stainless Steel or Corrosion-Resistant System |
| Compliance | Designed for Industrial Process Monitoring and Trace Impurity Analysis |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | 592 |
| Detector Type | Discharge Ionization Detector (DID) |
| Detection Range | 1 ppb to <0.5% (v/v) |
| Carrier Gas | Ultra-High-Purity Helium |
| Installation Options | Benchtop or 19″ Rack-Mounted |
| Construction Options | Stainless Steel or Corrosion-Resistant Wet-Coated Surfaces |
| Compliance | Designed for ASTM D7613, ISO 8573-5, and semiconductor-grade gas purity monitoring |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Imported |
| Model | PM 8202P |
| Measurement Range | -2 to 16 pH, -2000 to +2000 mV, 0 to 130 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±0.1 mV, ±0.1 °C |
| Temperature Compensation Range | -10 to 130 °C (manual/automatic |
| Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | PM8200P |
| Measurement Range | pH: −2.00–16.00 |
| ORP | −2000–+2000 mV |
| Resolution | pH: 0.01 pH |
| ORP | 1 mV |
| Accuracy | pH: ±0.01 pH |
| ORP | ±1 mV |
| Temperature Compensation | −10–130 °C (NTC10k or PT1000, auto/manual) |
| Display | Backlit dot-matrix LCD |
| Data Storage | 600,000 records |
| Output | Dual isolated 4–20 mA (max. 500 Ω, 0.1% FS) |
| Communication | RS485, MODBUS RTU compliant |
| Relay Control | Dual programmable relays with adjustable hysteresis |
| Cleaning Function | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Operating Temperature | 0–70 °C |
| Storage Temperature | −20–70 °C |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202D |
| Measurement Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Resolution | 0.001 ppm / 0.01 ppb |
| Temperature Compensation | −10 to +130 °C (manual or automatic, NTC10K/PT1000 sensor support) |
| Communication Interface | RS485 Modbus RTU |
| Dimensions | 144 × 144 × 108 mm (H × W × D) |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer | GreenPrima GmbH |
| Product Type | Ultrasonic Level Meter |
| Model | PROLEV500 |
| Sensor Models | PSU06 (0.3–6 m range), PSU12 (0.5–12 m range) |
| Accuracy | ±0.2% FS |
| Resolution | 1 mm |
| Max Process Pressure | 1.0 bar |
| Operating Temperature (Sensor) | −30 to +70 °C |
| Operating Temperature (Controller) | −20 to +60 °C |
| Sensor Housing Material | PC/PP |
| Controller Housing Material | ABS |
| Display | 320 × 240 pixel color LCD with backlight |
| Outputs | Dual 4–20 mA analog outputs + Modbus RTU (RS-485) + 2 relays (PROLEV500) or 5 relays (PROLEV500D) |
| Power Supply | 85–230 V AC or 24 V DC |
| Ingress Protection | IP66 (controller), IP68 (sensor) |
| Mounting Options | Wall, pipe, or DIN rail |
| Dimensions (Controller) | 184 × 223 × 130 mm |
| Cable Length | 10 m standard |
| Process Connection | G1" female thread |
| Sensor Diaphragm Material | ETFE or PVDF |
| Signal Processing | Microprocessor-based echo analysis with adaptive gain control, temperature compensation, and false-echo suppression |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PSTAB500 |
| Price | Upon Request |
| Nominal Diameter Range | DN10–DN2200 |
| Flow Velocity Range | 0.1–15 m/s |
| Accuracy | ≤0.3% of reading |
| Repeatability | ±0.1% of reading |
| Minimum Conductivity | >5 µS/cm |
| Electrode Materials | 316L stainless steel, Hastelloy B/C, Titanium, Tantalum, Platinum-Iridium, Niobium |
| Lining Materials | PTFE, F46, Neoprene, Polyurethane |
| Process Temperature | –30°C to +250°C |
| Ambient Temperature | –30°C to +65°C |
| Enclosure Rating | IP65 / IP67 / IP68 |
| Configuration | Integral or Remote (Split-type) |
| Output Signals | 4–20 mA, Frequency/Pulse, Dry Contact |
| Communication Protocols | MODBUS RTU (standard), HART, GPRS (optional) |
| Power Supply | 85–260 VAC or 11–40 VDC |
| Display | Backlit LCD |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GTI-145 |
| Price | USD 295 (FOB) |
| Pressure Range | 0–5 kPa (selectable from 0–50 Pa to 0–5 kPa) |
| Accuracy | ±(1.0% FS + 1 digit) @ 23°C (for ranges ≥500 Pa) |
| Resolution | 0.1 Pa (0–50 Pa range), 1 Pa (0–500 Pa), 2 Pa (0–2 kPa), 5 Pa (0–5 kPa) |
| Overpressure Limit | 10 kPa (GTI-135), 20 kPa (GTI-145) |
| Output | 4–20 mA / 1–5 VDC (configurable) |
| Display | 4-digit segmented LCD (Pa or kPa selectable) |
| Update Rate | 200 ms |
| Zero Adjustment | Manual potentiometer |
| Temperature Coefficient | ±0.15% FS/°C (<500 Pa), ±0.10% FS/°C (≥500 Pa) |
| Power Supply | 12–24 VDC (±10%), max. 50 mA @ 12 V, 30 mA @ 24 V |
| Response Time | <5 ms |
| Filtering | Adjustable moving average (0.2 s / 1 s / 2 s / 4 s) |
| Operating Temp. | 0–60°C |
| Storage Temp. | −10–70°C |
| Humidity | 35–85% RH (non-condensing) |
| Enclosure Rating | IP40 |
| Housing Material | PC/ABS blend |
| Mounting | Wall-mount or bracket-mount with snap-fit clips |
| Dimensions | GTI-135: 30 × 30 × 35 mm |
| GTI-145 | 24 × 48 × 73 mm |
| Weight | 30 g (GTI-135), 40 g (GTI-145) |
| Process Connection | M5 internal thread + φ3.5 mm barbed fitting |
| Media Compatibility | Clean, dry, non-corrosive gases (e.g., air, nitrogen) |
| Pollution Degree | 2 per IEC 60664-2 |
| Ingress Protection | Compliant with IEC 60529 (IP40) |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GTI113 |
| Price | USD 765 (based on ¥5520 at 1 USD ≈ ¥7.2) |
| Accuracy | ±0.5% of reading ±0.5 Pa |
| Resolution | 0.1 Pa |
| Differential Pressure Range | ±500 Pa |
| Overpressure Limit | ±10 kPa |
| Air Velocity Range | 0.2–25 m/s |
| Air Velocity Accuracy | ±1.5% of reading at 10.0 m/s |
| Velocity Resolution | 0.01 m/s |
| Volumetric Flow Range | 0–999999 m³/h |
| Flow Resolution | 1 m³/h |
| Temperature Measurement | Integrated |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V adapter |
| Battery Life | >15 hours |
| Weight (with batteries) | 363 g |
| Display | High-resolution color LCD |
| Units | Multiple selectable pressure units (Pa, kPa, inH₂O, mmH₂O, psi, mbar, etc.) |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GTI135 / GTI145 |
| Price | USD 295 (FOB) |
| Sensor Technology | Micro Silicon Piezoresistive |
| Display | 4-Digit Segment LCD |
| Output Options | Dual NPN/PNP Open-Collector Switches + Analog Output (4–20 mA or 1–5 VDC) |
| Accuracy | ±(1.0–2.0)% FS + 1 digit (depending on range) |
| Resolution | 0.1 Pa to 2 Pa (range-dependent) |
| Overpressure Limit | 10 kPa (GTI135), 20 kPa (GTI145) |
| Operating Temperature | 0–60 °C |
| Power Supply | 12–24 VDC (±10%) |
| Response Time | <5 ms |
| IP Rating | IP40 |
| Enclosure Material | PC/ABS |
| Mounting | Wall-mount or bracket-mount |
| Weight | 30 g (GTI135), 40 g (GTI145) |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GTI.150 |
| Output Signal | 1–5 V DC |
| Accuracy | ±1% FS (GTI150-□A□□) |
| Pressure Ranges | 0–1 MPa / 0 to –101 kPa (gauge/vacuum) / –100 to +100 kPa (differential) |
| Overpressure Limit | 1.2 MPa / 300 kPa |
| Operating Temperature | 0–50 °C |
| Storage Temperature | –20–70 °C |
| IP Rating | IP40 |
| Power Supply | 12–24 V DC |
| Current Consumption | <10 mA |
| Output Impedance | ~1 kΩ |
| Linearity | <±0.5% FS |
| Repeatability | ±0.2% FS |
| Humidity Range | 35–85% RH (non-condensing) |
| Cable | 3-conductor round cable, Ø3 mm, 3 m length, conductor area 0.15 mm² |
| Housing Material | ABS engineering plastic |
| Wetted Parts | SUS304 stainless steel (pressure port), HPb59-1 brass (fittings), NBR O-rings |
| Dimensions | 30 × 13 × 10 mm (L×W×H) |
| Weight (with cable) | 41.2–50.1 g (model-dependent) |
| Compliance | CE marked |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LDO |
| Price | Upon Request |
| Measurement Range | 0.01–20 mg/L (ppm) and 0–200% saturation |
| Resolution | 0.01 mg/L |
| Repeatability | ±0.1 mg/L (0–8 mg/L) |
| Temperature Compensation | Automatic |
| Dimensions | 20 × 10 × 5 cm |
| Brand | Hamilton |
|---|---|
| Origin | Switzerland |
| Model | H100 pH |
| Measurement Range | pH −2.00 to 16.00 |
| ORP | −1500 to +1500 mV |
| Temperature Input | Pt100 / Pt1000 / NTC 30 kΩ |
| Temperature Range | −20 to +150 °C |
| Temperature Resolution | 0.1 °C |
| Measurement Error | <1 mV |
| Analog Outputs | Dual 4–20 mA (floating, max 10 V) |
| Relay Output | Configurable (alarm/flush), 3 A / <250 VAC or 30 VDC |
| Housing Material | PBT |
| Enclosure Rating | IP65 / NEMA 4X |
| Power Supply | 24–230 V AC/DC |
| Display | 7-segment LCD with icons |
| Operating Humidity | 0–80% RH at ≤55 °C |
| FM Certification | Class I, Div. 2, Groups A/B/C/D & IIC, T4, Ta = 55 °C, Type 2 |
| Key | Brand: Onset |
|---|---|
| Model | U26 |
| Sensor Type | Optical (Dynamic Fluorescence Quenching) |
| DO Range | 0–30 mg/L |
| Calibration Range | 0–20 mg/L |
| Accuracy | ±0.2 mg/L (0–8 mg/L), ±0.5 mg/L (8–20 mg/L) |
| Resolution | 0.02 mg/L |
| Response Time (t₉₀) | <2 min |
| Temperature Range | −5 to 40 °C |
| Temp Accuracy | ±0.2 °C |
| Temp Resolution | 0.02 °C |
| Memory | 64 KB (21,700 readings) |
| Logging Interval | 1 min – 18 hr |
| Battery Life | Up to 6 months typical |
| Depth Rating | ≤100 m |
| Dimensions | Ø3.96 cm × 26.67 cm |
| Weight | 464 g |
| Power | 3.6 V lithium battery |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT Online Copper Sulfate and Nickel Ion Analyzer for Electroplating Lines |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ALT-1 |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH, 10 °C minimum (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV) |
| pH | 0.001 pH (0–20 pH) |
| Photometric | 0.003 Abs (0–1 Abs) |
| Enclosure Rating | IP55/IP65 (with door locked), optional higher ratings available |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Product Type | Online Potentiometric Titration Analyzer |
| Model | ALT-1 |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory equivalence and GLP-compliant industrial deployment |
| Measurement Principle | Automatic potentiometric titration (pH and redox endpoint detection) |
| Accuracy | ±3% relative deviation vs. reference manual titration |
| Sampling Frequency | Configurable up to once every 30 minutes |
| Output Interface | 4–20 mA, Modbus RTU/TCP, Ethernet/IP |
| Environmental Rating | IP65 enclosure |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT-1 Online Titration Analyzer for Electroplating Baths |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Type | Online Titration Analyzer |
| Model | ALT-1 |
| Application Domain | Electroplating Chemical Process Monitoring & Automated Reagent Dosing |
| Measurement Principle | Potentiometric/Colorimetric Endpoint Detection with Programmable Burette Dispensing |
| Compliance Framework | Designed for GLP/GMP-aligned process documentation, supports audit-ready data logging per FDA 21 CFR Part 11 requirements (electronic signatures, user access control, immutable event logs) |