| Brand | DoctorWater |
|---|---|
| Model | Dr-W390 |
| Measurement Parameters | pH (0–14), Residual Chlorine (0–2 / 0–20 mg/L), Dissolved Oxygen (0–20 mg/L), Conductivity (0–2000 / 0–20000 µS/cm), Temperature (0–60 °C) |
| Conductivity Range | 0–2000 µS/cm, 0–20000 µS/cm |
| Temp. Range | 0–60 °C |
| Accuracy | ±2% F.S. (all parameters) |
| Conductivity Resolution | 0.01 µS/cm |
| Temp. Compensation | Automatic |
| Data Storage | 500,000 records |
| Output | Dual 4–20 mA (±0.05 mA accuracy), RS485 Modbus RTU |
| Relay Outputs | 1 multifunctional relay (cleaning/interval/error alarm), 2 controllable relays with adjustable delay |
| Update Interval | 1–60 s adjustable |
| Enclosure Rating | IP68 (electrode), IP65 (controller) |
| Max. Pressure Rating | up to 4 bar (conductivity sensor) |
| Cable Length | 5 m standard (customizable) |
| Brand | Drexelbrook |
|---|---|
| Origin | Shanghai, China |
| Model | DR5400 Series |
| Measurement Principle | FMCW (Frequency-Modulated Continuous Wave) Radar |
| Output Signal | 2-wire 4–20 mA with HART® Protocol |
| Max. Measuring Range | 30 m |
| Accuracy | ±5 mm (standard), ±10 mm (extended range) |
| Beam Angle | as low as 6° |
| Antenna Options | 316L Stainless Steel Horn or PP/PTFE Rod Antenna (extendable) |
| Process Temperature | –40 °C to +250 °C |
| Process Pressure | –0.1 MPa to +4 MPa |
| Enclosure Rating | IP66/IP67 |
| Brand | Drexelbrook |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-sourced) |
| Model | Usonic Series |
| Product Type | Ultrasonic Level Transmitter |
| Measurement Principle | Pulse-Echo Ultrasonic Time-of-Flight |
| Maximum Range | 9.1 m |
| Beam Angle | 5° |
| Brand | Beijing Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | DYM3 |
| Price | Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | DYM3 |
| Pricing | Upon Request |
| Measurement Range | 800–1064 hPa |
| Operating Temperature | −10 to +40 °C |
| Accuracy | ±2.5 hPa |
| Scale Division | 1 hPa |
| Thermometer Division | 1 °C |
| Weight | ≤1.5 kg |
| Dimensions | 156 × 156 × 115 mm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ecotec® E3000 |
| Pricing | Upon Request |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1153 |
| Conductivity Range | 0–2000 pS/m |
| Accuracy | ±2% of reading |
| Resolution | ±1 pS/m (0–2000 pS/m) |
| Dimensions | 200.7 mm × 70 mm × 43.2 mm (L×W×D) |
| Operating Temperature | 0–50 °C |
| Power Supply | Three 3 V lithium batteries |
| Intrinsic Safety Certification | Class I, Division 1, Group D |
| Display | 5-digit LCD with status text |
| Probe Diameter | 19.05 mm |
| Weight | 365.8 g |
| Enclosure | Solvent-resistant rigid plastic carrying case |
| Origin | Switzerland |
|---|---|
| Type | Imported Instrument |
| Model | 712 |
| Compliance | USP, GLP, ISO 9000 |
| Conductivity Range | 0.001 µS/cm to 20 S/cm |
| Temperature Range (Pt100/Pt1000) | −170 °C to +500 °C |
| TDS Range (as NaCl) | 0.5 mg/L to 300 g/L |
| Measurement Frequencies | 300 Hz / 2.4 kHz (auto-selectable) |
| Auto-Zero Function | Yes |
| Reference Temperature | User-Selectable |
| Cell Constant & Temp. Coefficient | Auto-Determined |
| Analog Output | Programmable |
| Digital Interface | RS-232C (bidirectional) |
| Platinization Current | 20 mA |
| Real-Time Plotting | Conductivity & Temperature vs. Time |
| I/O Lines | Min/Max Limit Outputs, Sample Changer Control |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8869 |
| Pricing | Upon Request |
| Measurement Principle | Thermal Conductivity |
| Full Scale Range | 0–100% H₂ |
| Certifications | CE, EN 61326-1:2013/A1:2016, EN 61010-1:2010 |
| Power Supply | 220 VAC, 47–63 Hz, 20 W |
| Enclosure Rating | IP65 per EN 60529 |
| Weight | ~25 kg |
| Sample Gas Connection | 1.4571 stainless steel tubing, Ø6 mm or 1/4″ |
| Leak Rate | <1 µL/s |
| Sample Gas Pressure | 800–1100 hPa (absolute) |
| Sample Flow Rate | 0.5–1.5 L/min |
| Sample Temperature | 0–50 °C |
| Measurement Cell Temperature | ~60 °C |
| Sample Humidity | <90% RH |
| Purge Gas Pressure | 165 hPa (short-term purge: 250 hPa) |
| Warm-up Time | 2 h |
| Response Time (T₉₀) | 5 s |
| Dead Time | ~0.5 s |
| Damping Time | Adjustable 0–100 s |
| Zero Drift | <1% of minimum span/month |
| Repeatability Error | <1% of full scale |
| Linearity Error | ±1% of full scale |
| Output Signal Stability | ±0.75% of minimum span |
| Relay Outputs | 6 × 24 V AC/DC, 1 A, floating, freely configurable |
| Analog Inputs | 2 × 0/2/4–20 mA, cross-interference compensation |
| Binary Inputs | 6 × 24 V, floating, freely configurable |
| Communication Interface | RS-485 |
| Operating Ambient Temperature | 5–45 °C |
| Storage & Transport Temperature | −30 to +70 °C |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 8866 |
| Price | USD 9,400 (FOB) |
| Measurement Principle | Thermal Conductivity Detection (TCD) |
| Range Options | 0–1%, 0–2%, 0–5%, 0–10%, 0–15%, 0–20%, 0–30%, 0–40%, 0–75%, 0–100%, 80–100%, 95–100%, 98–100% He in Ar (also configurable for H₂, CH₄, CO, CO₂, N₂, Ar mixtures) |
| Accuracy | ±1% FS |
| Repeatability | ≤0.3% FS |
| Linearity Error | ≤1% FS |
| Response Time (t₆₀/t₉₀/t₉₉) | H₂ <1 s / 13 s / 24 s / 40 s |
| Zero Drift | ≤1% FS/week |
| Sample Flow Rate | 100 mL/min to 2 L/min |
| Inlet Fitting | 1/4" Swagelok or 6 mm compression |
| Analog Outputs | Four isolated 4–20 mA outputs |
| Digital Communication | RS232 & RS485 (Modbus RTU) |
| Power Supply | 24–30 VDC (sensor), or 115 VAC ±10% / 220 VAC ±20%, 50 ±0.5 Hz, 150 VA |
| Enclosure Rating | IP66 |
| Explosion Protection | ATEX II 2G Ex d IIC T6 Gb, CSA Class I, Division 1, Groups A, B, C, D, T6 |
| Hazardous Area Classification | Zone 1, Zone 2, Class I Div 1 |
| Controller Options | Intrinsically Safe (Ex ia) and Non-Explosive Versions Available |
| Brand | Eranntex |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | LMIC-600-CH3Br |
| Detection Principle | Photoionization Detection (PID) |
| Measurement Range | 0–100 ppm CH₃Br |
| Resolution | 0.01 ppm (0–100 ppm) |
| Output Signals | RS485 (Modbus RTU), 4–20 mA, 3 relay outputs |
| Environmental Rating | IP66, Exd IIC T6 Gb |
| Operating Temperature | −40 °C to +70 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Power Supply | 12–36 VDC |
| Display | 2.5″ color LCD |
| Compliance | GB 15322.1–2019, GB 3836.1/2–2010, CMC certification, EMI/EMC compliant |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 875 SupLab |
| Pricing | Available Upon Request |
| Dimensions (Total System) | 1200 mm (W) × 650 mm (D) × 1750 mm (H) |
| Control Unit | 260 mm (W) × 100 mm (D) × 200 mm (H) |
| Sample Handling Unit | 450 mm (W) × 650 mm (D) × 750 mm (H) |
| Analytical Unit | 650 mm (W) × 500 mm (D) × 1550 mm (H) |
| Power Supply | 198–242 V AC, 50 Hz ± 0.5 Hz, 500 VA |
| Operating Environment | 15–30 °C, RH 45–85 % (max. daily temperature fluctuation ≤5 °C) |
| Touchscreen Interface | 10-inch full-color serial touch panel |
| Standard Configuration | 4 modular detection channels |
| Throughput | ~10 min for simultaneous quantification of up to 4 analytes in a single sample |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Model | PA4011 |
| Measurement Principle | Spectrophotometry |
| Analysis Time | ≤30 s per measurement |
| Sample Channels | 1–3 (configurable) |
| Analytes | Cu²⁺ and/or Fe²⁺/Fe³⁺ in plating baths |
| Detection Method | Absorbance-based quantification using pre-calibrated calibration curves |
| Reagent-Free Operation | Yes |
| Waste Generation | None |
| Display | 7-inch full-color touchscreen |
| Enclosure Dimensions (PA4011, without reagent cabinet) | 300 mm (W) × 170 mm (D) × 400 mm (H) |
| Power Supply | 198–242 V AC, 50 Hz ±0.5 Hz, 100 W |
| Operating Environment | 15–35 °C, RH ≤95% (non-condensing) |
| Communication Interfaces | RS232, RS485, 4–20 mA analog output, TCP/IP Ethernet |
| Operational Modes | Manual, timed cycle, continuous, and external trigger-controlled |
| Data Management | Time-stamped historical storage, categorized query, exportable CSV/Excel |
| Alarm Functions | Concentration limit violation detection with visual/audio alerts and configurable relay outputs |
| Compliance | Designed for GLP-aligned process monitoring |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PA4015 |
| Pricing | Available Upon Request |
| Measurable Parameters | Nitric Acid, Hydrochloric Acid, Sulfuric Acid, Sodium Hydroxide, Carbonates, Nitrates, Phosphates, Free Ammonia, Chlorides, Fluorides, Hypochlorites, Persulfates, Hydrogen Peroxide, and others |
| Brand | ETI |
|---|---|
| Model | PA4025 |
| Origin | Guangdong, China |
| Type | Online Reaction Analysis System |
| Measurement Principles | Potentiometric Titration, Photometric Detection, Ion-Selective Electrode (ISE), Direct Sensor Measurement (pH, Conductivity, Refractometry) |
| Sample Compatibility | Aqueous acidic/alkaline process streams containing HNO₃, HCl, H₂SO₄, NaOH, Na₂CO₃, NH₃ (free), Cl⁻, F⁻, ClO⁻, S₂O₈²⁻, H₂O₂, PO₄³⁻, NO₃⁻, Cu²⁺, Fe²⁺/³⁺, Ni²⁺, Cr³⁺/⁶⁺, Zn²⁺, Ag⁺, Cd²⁺, Mn²⁺, Co²⁺, Li⁺, SO₄²⁻, CN⁻, EDTA, etc. |
| Cabinet Dimensions | ~620 mm (W) × 550 mm (D) × 1735 mm (H) |
| Power Supply | 198–242 V AC, 50 Hz ±0.5 Hz |
| Operating Environment | 15–35 °C, RH ≤95% (non-condensing) |
| Interface | 15″ color touchscreen (Windows OS) |
| Communication | RS232, RS485, 4–20 mA analog outputs, Ethernet |
| Programmability | Up to 15 customizable analysis workflows |
| Compliance Support | ASTM D129, ISO 9297, USP <731>, EPA Method 300.0, GLP/GMP-ready audit trail logging (via optional software module) |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PA4030 |
| Price | Upon Request |
| Analyte Range | Nitric Acid, Hydrochloric Acid, Sulfuric Acid, Sodium Hydroxide, Carbonates, Nitrates, Phosphates, Free Ammonia, Chlorides, Fluorides, Hypochlorites, Persulfates, Hydrogen Peroxide, and more |
| Dimensions | 620 mm (W) × 550 mm (D) × 1850 mm (H) |
| Power Supply | 198–242 V, 50 Hz ± 0.5 Hz, 350 W |
| Operating Environment | 15–30 °C, RH 65 % ± 20 % (max. daily temp. swing ≤5 °C) |
| Display | 12-inch full-color touchscreen (serial interface) |
| Communication | RS485 or TCP/IP |
| Detection Methods | Potentiometric Titration, Photometric Titration, Direct Electrode Measurement (pH, Conductivity, Refractometry), Ion-Selective Electrode (ISE) with Standard Addition, UV-Vis Absorbance-based Quantification |
| Workflow Modes | Manual, Scheduled, Continuous, Triggered |
| Data Management | Audit-trail-enabled logging, QC flagging, concentration limit alerts, reagent level monitoring, sample absence detection, leak detection |
| Cabinet Type | Freestanding floor-mounted enclosure |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PA5030 |
| Price | Upon Request |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Sample Throughput | Up to 12 sample positions (configurable) |
| Elemental Range | Z = 14 (Si) to 92 (U) |
| Analysis Time per Sample | ≤ 300 s |
| Detection Geometry | Fixed vertical beam path with automated sample positioning |
| Power Supply | 198–242 V AC, 50 Hz ± 0.5 Hz, 100 W |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 45–85 % RH (non-condensing) |
| Enclosure Dimensions | Approx. 800 mm (W) × 820 mm (D) × 1710 mm (H) |
| User Interface | 15″ capacitive touch display running Windows 10 IoT Enterprise |
| Communication Protocols | RS-485 (Modbus RTU), TCP/IP (Ethernet), OPC UA optional |
| Compliance | CE, RoHS, IEC 61000-6-3/6-4, ISO 21043 (XRF performance verification guidelines), ASTM E1621–22 (Standard Guide for XRF Analysis of Ceramic Whiteware) |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PA5080 |
| Pricing | Upon Request |
| Application Domain | Electroplating Process Monitoring in Electronics, Semiconductor Fabrication, and Metal Surface Finishing |
| Electrode Configuration | Three-Electrode System (Platinum Rotating Disk Working Electrode, 5 mm diameter |
| Temperature Control | Full-System & Flow-Path Thermal Regulation (±0.2 °C stability) |
| Power Supply | 198–242 V AC, 50 Hz ±0.5 Hz, 1000 W |
| Ambient Operating Range | 15–35 °C |
| Human-Machine Interface | 15-inch Full-Color Touchscreen (Windows OS) |
| Cabinet Dimensions | Approx. 650 mm (W) × 750 mm (D) × 1750 mm (H) |
| Measurement Principle | Cyclic Voltammetric Stripping (CVS) with Potentiodynamic Scanning and Faradaic Current Integration |
| Automation Capability | Integrated Reagent Dosing Control for Organic Additive Correction Based on Real-Time Analytical Deviation |
| Software Compliance | Audit Trail, User Access Levels, Electronic Signature Support (FDA 21 CFR Part 11 Ready) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | EyeTech Online Oil-in-Water Analyzer |
| Price | Upon Request |
| Measurement Parameters | Particle Size & Shape |
| Concentration Range | 0–2000 ppm |
| Particle Size Range | 2–300 µm |
| Accuracy | ±4% or ±4 ppm |
| Sample Temperature | 2–120 °C |
| Sample Pressure | Up to 20 bar |
| Automation Level | Fully Automatic |
| Cleaning System | Integrated Thermal Boosted Water Wash |
| Real-time Output | Alarm triggers on oil concentration threshold, particle size threshold, and wash pressure failure |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | EyeTech Online Particle Size and Shape Analyzer |
| Pricing | Available Upon Request |
| Brand | SOLGE |
|---|---|
| Origin | South Korea |
| Model | Solge EZ-LubeCheck |
| Type | Portable In-Field Oil Moisture Analyzer |
| Power | Integrated Rechargeable Battery |
| Measurement Principle | Capacitive Dielectric Spectroscopy |
| Output | % Water by Volume (v/v) and ppm (optional calibration) |
| Compliance | Designed for ISO 4406, ASTM D6304 (Karl Fischer correlation), and OEM lubrication condition monitoring protocols |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | SIGMASCOPE SMP350 |
| Measurement Principle | Phase-Sensitive Eddy Current Method |
| Compliance | DIN EN 2004-1, ASTM E1004 |
| Frequency Range | 15 kHz to 1 MHz |
| Calibration Standards | Traceable to International Reference Standards (MS/m and %IACS) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FJA-04 |
| Price | USD 410 (FOB) |
| Enclosure Rating | IP65 |
| Output Options | 4–20 mA / 0–1400 mV |
| Measurement Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.02 pH ±1 digit (at 25 °C) |
| Input Impedance | >10¹² Ω |
| Temperature Compensation | Automatic (NTC 10 kΩ, 25 °C nominal) |
| Installation | Panel-mount (92.7 × 92.7 mm cutout), wall-mount compatible |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FluidMaster |
| Type | Turnkey Laser Imaging System for Quantitative Fluid Mixing & Thermal Flow Analysis |
| Imaging Modalities | Planar Laser-Induced Fluorescence (LIF), Rayleigh Scattering, Raman Scattering |
| Measurement Outputs | Instantaneous 2D/3D concentration fields, temperature fields, pH distribution, reactive mixing degree, gas density maps |
| Spatial Resolution | µm-to-mm scale (application-dependent) |
| Temporal Resolution | Up to kHz frame rates (camera- and laser-pulse-limited) |
| Calibration | Traceable hardware and signal calibration per ISO/IEC 17025 principles |
| Software Platform | DaVis v10+ with real-time acquisition, multi-parameter synchronization, and GLP-compliant data logging |
| Brand | LINGXI OPTOELECTRONICS |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | TGA-321 |
| Pricing | Upon Request |
| Brand | LINGXI OPTOELECTRONICS |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | TGA-323 |
| Pricing | Upon Request |
| Brand | LINGXI OPTOELECTRONICS |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TGA-327 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CLA-8000 |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GC-1010-AA/AE |
| Pricing | Upon Request |
| Channel Count | 10 |
| Mounting Type | Wall-Mounted |
| Sensor Interface | 2-wire & 3-wire toxic/combustible gas detectors |
| Display | LCD + High-Brightness LED Indicators |
| Communication Interfaces | RS485, Ethernet |
| Output | 1 × 24 V DC Active Output |
| Alarm Logic | Multi-sensor Intelligent Voting Algorithm |
| Signal Acquisition | Synchronized Real-Time Sampling |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GRD-2000 |
| Pricing | Upon Request |