| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 660 |
| Compliance | ASTM D5, D217, D937, D1321, D1403, D1831, D2884 |
| Power Supply | 220 V / 50 Hz, 50 W |
| Safety Certification | CE |
| Penetration Range | 0–50 mm |
| Cone Mass | 47.5 g (standard) |
| Needle Mass | 2.5 g (ASTM D5-compliant) |
| Timer Resolution | 0.1 s, Programmable Duration (1–60 s) |
| Temperature Control | Compatible with external thermostatic water baths (e.g., 25 °C ± 0.1 °C) |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ABA 300 & ABA 500 |
| Detection Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Temperature Range | 10 °C to 110 °C (air-cooled) |
| Ignition Source | Electronic (encapsulated hot-wire) |
| Repeatability | ±1.4 °C |
| Compliant Standards | ISO 13736, ISO 1516, ISO 1523, GB/T 21789, GB/T 21775, GB/T 21792 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ABA 500 |
| Detection Method | Closed Cup |
| Operation Mode | Automatic |
| Temperature Range | −35 °C to +130 °C |
| Ignition Method | Electronic (Encapsulated Hot Wire) |
| Applicable Standards | ISO 13736, ISO 1516, ISO 1523, GB/T 21789 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ALAB 5000 |
| Instrument Type | Integrated Online Beverage Quality Analyzer & Cap Torque Tester |
| Application Mode | In-line / At-line |
| Measurement Time (Analytic) | 8 min per sample |
| Measurement Time (Torque) | 30 s per sample |
| Alcohol Content Range | 0–12 % v/v |
| pH Range | 0–14 |
| Dimensions (L × W × H) | 1750 mm × 880 mm × 2430 mm |
| Weight | 900 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Alcolyzer Beer Analyzing System |
| Instrument Type | Beer-Specific Analyzer |
| Application Type | Laboratory |
| Measurement Time | 3 min |
| Alcohol Content | 0–12 % v/v |
| pH Range | 0–14 |
| Dimensions (L × W × H) | 495 × 330 × 230 mm |
| Weight | 30 kg |
| Technology | Infrared |
| Sample Volume per Test | 35 mL |
| Throughput | 15–20 samples/hour |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Alex 301 / Alex 501 |
| Instrument Type | Brewery-Specific Analyzer |
| Application | Laboratory Use |
| Alcohol Range | Beer 0.5–15 % v/v |
| Density Measurement Range | 0.9500–1.200 g/cm³ |
| Accuracy (Alcohol) | ±0.25 % v/v (Alex 301), ±0.2 % v/v (Alex 501) |
| Repeatability (Alcohol) | 0.15 % v/v (Alex 301), 0.1 % v/v (Alex 501) |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability (Std. Dev.) | 0.0007 g/cm³ (Alex 301), 0.0005 g/cm³ (Alex 501) |
| Density Resolution | 0.0001 g/cm³ |
| Sample Volume | 40 mL |
| Dimensions (L × W × H) | 320 mm × 230 mm × 100 mm |
| Weight | ~2.4 kg |
| Operating Temperature | 10–32 °C |
| Sample Temperature Range | 15–25 °C (Alex 301), 10–30 °C (Alex 501) |
| Interfaces | 1× Bluetooth®, 1× RS-232 (9-pin D-sub), 1× USB-B |
| Power Supply | 100–240 V~, 50/60 Hz, ±10%, DC 15 V / 2.6 A |
| Power Consumption | 20 W |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Betalyser |
| Price | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH (Petrotest GmbH, a company of Anton Paar) |
| Product Category | Imported |
| Model | BPA |
| Price | Upon Request |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | AbsorptoMeter |
| Standards Compliance | ASTM D2414, ASTM D3493, ASTM D6854 |
| Measurement Principle | Automated Titration-Based Oil Absorption (OAN) |
| Construction | Stainless Steel Housing |
| Software | Integrated PC-Based Control with Audit Trail & Data Export |
| Sample Handling | Dedicated Mixing Discs for Carbon Black & Silica |
| Viscosity Range | Up to 1,000,000 mPa·s |
| Solvent Compatibility | NMP, Paraffin Oil, and Other Standard Oils |
| Automation Level | Fully Automated Titration, Dosing, Mixing, Endpoint Detection |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | AbsorptoMeter |
| Standards Compliance | ASTM D2414, ASTM D3493, ASTM D6854 |
| Construction | Stainless steel housing |
| Automation | Software-controlled titration system |
| Titration Range | Adjustable dosing rate, suitable for viscosities up to 1,000,000 mPa·s |
| Solvent Compatibility | Compatible with aggressive solvents (e.g., NMP) |
| Data Management | Real-time result comparison, scheduled measurements, CSV/Excel export |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Aquatrac-V |
| Measurement Principle | Calcium Hydride Reaction under Vacuum |
| Compliance | DIN EN ISO 15512:2019 |
| Resolution | 0.0001% H₂O (w/w) |
| Application Scope | Polymer Residual Moisture Analysis & MFR Sample Conditioning |
| Software | Aquatrac Control Software with Audit Trail, LIMS/ERP Integration Capability |
| Regulatory Alignment | Supports GLP/GMP workflows and FDA 21 CFR Part 11–compliant data integrity requirements |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Extensograph-E |
| Compliance | ISO 27971, AACC Method 54-10, ICC Standard No. 115 |
| Sample Capacity | Standard (300 g dough) and Mini (100 g dough) configurations available |
| Measurement Principle | Uniaxial tensile deformation under controlled temperature and humidity |
| Data Output | Force (N), Extensibility (mm), Energy (mJ), Resistance to Extension (R, N), Ratio R/E, Curve Area Integration |
| Software Platform | MetaBridge v4.x with audit trail, user roles, and electronic signature support |
| Connectivity | OPC UA, CSV export, LIMS/ERP integration via REST API |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | FarinoGraph |
| Compliance | ICC, AACCI, ISO 5530-1, ISO 21415 |
| Measurement Unit | Brabender Unit (BU) / Farinograph Unit (FU) |
| Stirring Capacity | 10 g to 300 g |
| Water Dosage | Automated via AquaInject module |
| Data Management | MetaBridge web-based software |
| Connectivity | LIMS/ERP integration supported |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | FarinoGraph |
| Weight (without S300 mixer) | 56 kg |
| Weight (with S300 mixer) | 74 kg |
| Dimensions (W × H × D) | 430 mm × 630 mm × 740 mm |
| Torque | 28 N·m |
| Speed Range | 0–200 rpm |
| Power Supply | 230 V (184–264 V) + N + PE / 50–60 Hz / 4.3 A / 1 kW or 115 V (88–126 V) + PE / 50–60 Hz / 8.7 A / 1 kW |
| Interfaces | 4 × USB, 1 × HDMI, 2 × LAN |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer Entity | Authorized Distributor |
| Origin Category | Imported |
| Model | GlutoPeak |
| Pricing | Available Upon Request |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | MT-CA |
| Measurement Principle | Thermogravimetric (Heated Chamber Drying) |
| Moisture Range | 0.1% to 99.9% |
| Sample Capacity | Up to 10 positions |
| Compliance | ICC Standard 114, ISO 712, EC Tobacco Directive 2001/32/EC, USP <921>, ASTM D4457 |
| Software | MetaBridge v3.x (Web-based, Browser-Accessible) |
| Data Integrity | Audit Trail, User Access Levels, Electronic Signatures (21 CFR Part 11 Ready) |
| Footprint | Compact Benchtop Design |
| Interface | Integrated Touchscreen PC, Ethernet/Wi-Fi Connectivity |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model Series | Quadrumat Junior / Quadrumat Senior |
| Application | Laboratory-scale milling of wheat, durum, rye, barley and other cereals for flour quality analysis |
| Compliance | Designed in accordance with ISO 27971 (Cereal and cereal products — Determination of milling yield), ISO 5528 (Cereals — Sampling), and aligned with AACC International Method 26–10A (Milling of Wheat to Produce Flour for Baking Tests) |
| Key Features | Dual-roller (Junior) and quad-roller (Senior) configuration |
| Standard Sieve Aperture | 280 µm |
| Max. Feed Moisture Content | 18% w/w |
| Cleaning | Tool-free circular sieve removal |
| Optional Integration | Compatible with Brabender Debranning Unit (TorqueTec GmbH) for ash reduction and yield optimization |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar TorqueTec GmbH (formerly Brabender GmbH) |
| Model | SM 4 |
| Grinding Principle | Adjustable-gap roller mill with dual counter-rotating corrugated rollers |
| Max. Feed Capacity | 200 g per batch |
| Adjustable Gap Range | 0.1–3.0 mm (micrometer-adjustable) |
| Motor Power | 0.75 kW |
| Speed | 250 rpm (fixed) |
| Construction | Stainless steel housing, food-grade contact materials |
| Compliance | ISO 6540, ISO 712, ISO 20483, AOAC 991.20, AACC 22–10 |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | TSSR |
| Application | Isothermal and Non-isothermal Stress Relaxation Testing (TSSR/AISR Method) |
| Compliance Context | ASTM D624, ISO 37, ISO 6982, DIN 53515 |
| Software | Automated real-time data acquisition, spectral evaluation, and GLP-compliant storage |
| Measurement Principle | Torque-based viscoelastic stress decay under constrained strain in rotational rheometric configuration |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar TorqueTec GmbH (formerly Brabender GmbH) |
| Model | TwinLab Series |
| Configuration Options | Twin-screw extruder, single-screw extruder (e.g., 19/25 mm), batch mixer |
| Throughput Range | 0.05–100 kg/h |
| Drive System | MetaStation modular drive unit |
| Control Software | MetaBridge v3.x |
| Barrel Design | Split-barrel with quick-release liner |
| Material Contact Parts | Wear- and corrosion-resistant high-alloy steel (up to 500 °C service temperature) |
| Compliance | Designed for GLP/GMP-aligned R&D environments |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TwinLab Tobacco |
| Pricing | Upon Request |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | TwinLab |
| Configuration | Modular Twin-Screw / Single-Screw / Batch Mixer |
| Drive Unit | MetaStation |
| Control Software | MetaBridge |
| Temperature Range | Up to 500 °C |
| Throughput Range | 0.05–100 kg/h |
| Screw Diameter Options | 19 mm, 25 mm, and scalable modular configurations |
| Barrel Design | Split-barrel with removable liners |
| Material Compatibility | Liquids, powders, granules, high-abrasive & high-corrosive compounds |
| Compliance | Designed for GLP/GMP-aligned workflows, data audit trail capable (21 CFR Part 11–ready architecture) |
| Data Export | CSV, PDF, email-integrated reporting |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | TwinLab Rubber |
| Screw Diameter | 12 / 20 / 30 mm |
| L/D Ratio | 36 / 40 |
| Torque Capacity | 14 / 30 / 60 / 150 N·m |
| Operating Temperature | >500 °C |
| Throughput Range | 0.05–100 kg/h |
| Drive System | MetaStation Modular Drive Platform |
| Software | MetaBridge (Cross-Platform, Cloud-Ready, Audit-Trail Capable) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Viscograph-E |
| Sample Mass | 40 g |
| Compliance | ICC Standard No. 162, AACCI Method 76-15A |
| Temperature Control Accuracy | ±0.1 °C |
| Probe Type | Direct-contact immersion Pt100 sensor |
| Construction | Stainless steel bowl and stirrer |
| Software Platform | MetaBridge v3.x (supports FDA 21 CFR Part 11 audit trail, LIMS integration, multi-instrument synchronization) |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Callisto 100 |
| Temperature Range | –60 °C to +45 °C |
| Cooling Profile | Programmable stepwise or linear (6–100 °C/h) |
| Calibration | Automated calibration for sample/jacket temperature and vacuum |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 test results |
| User Programs | Up to 90 customizable methods |
| External Cooling Required | Yes (280 W at –20 °C) |
| Dimensions | 340 × 580 × 310 mm (W × D × H) |
| Weight | 14 kg |
| Power Supply | 100–240 V, 50/60 Hz, 290 VA |
| Interfaces | 4× USB, 1× RS232, 1× LAN, 1× VGA |
| Data Export | XLS, PDF via USB flash drive |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Series | CarboQC, CboxQC, OxyQC (At-line Configuration) |
| Measurement Time | 2–3 min per sample |
| Dimensions (L × W × H) | 258 mm × 201 mm × 170 mm |
| Weight | 2.6 kg |
| Data Storage Capacity | Up to 500 measurement datasets |
| Sample Volume | 150 mL |
| CO₂ Range | 0–12 g/L (0–6 vol%) at 30 °C |
| Dissolved O₂ Range | 0–4 ppm |
| Temperature Range | −3 °C to 30 °C |
| Pressure Range | 0–10 bar |
| CO₂ Repeatability (s.d.) | ±0.005 vol% |
| O₂ Repeatability (s.d.) | ±2 ppb |
| O₂ Response Time (t₉₈%) | 20 s at 25 °C |
| Pressure Accuracy | ±0.01 bar |
| CO₂ Accuracy (s.d.) | ±0.05 vol% |
| O₂ Accuracy (s.d.) | ±4 ppb |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Interfaces | 1 × USB (PC), 1 × RS-232 (printer or AP-SoftPrint) |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CLA 5 |
| Detection Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automated |
| Temperature Range | Up to 400 °C (°C/°F selectable) |
| Ignition Source | Pressurized Propane or Butane Gas |
| Compliant Standards | ASTM D92, ISO 2592, IP 36, DIN 51376, JIS K 2265 |
| Origin | France |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D525 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Diana 700 |
| Test Pressure | Atmospheric (101.3 kPa) |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling Bath Range | 0–80 °C |
| Distillation Rate | 2–12 mL/min |
| Volume Detection Range | 0–103.5 mL |
| Volume Resolution | 0.01 mL |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar (Petrotest GmbH, a company of Anton Paar) |
| Model | GUM |
| Operating Temperature Range | Ambient to 246 °C (air only) |
| Sample Positions | 5 simultaneous |
| Air Supply | 2–4 bar, oil-free and filtered |
| Steam Supply | Inlet temperature ≈140 °C, pressure 3–4 bar, controlled flow rate |
| Power Requirements | 230 V, 50/60 Hz, 2000 W (air mode) |
| Dimensions (W × D × H) | 400 × 400 × 720 mm |
| Weight | 44 kg |