| Brand | Sundhy |
|---|---|
| Origin | Hunan, China |
| Model | SDAF1200(a/b) |
| Sample Capacity | 1–10 specimens |
| Temperature Range | Ambient to 1600 °C |
| Temperature Resolution | 1 °C |
| Temperature Control Accuracy | ±1 °C |
| Atmosphere Control | Oxidizing / Weakly Reducing (SDAF1200a: Carbon-Sealing Method only |
| SDAF1200b | Carbon-Sealing + Gas-Flow Method with CO/CO₂ or H₂/CO₂ mixtures) |
| Max. Power | 4.2 kW |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 850 mm × 550 mm × 843 mm |
| Net Weight | ~108 kg |
| Compliance | GB/T 219–2008, GB/T 30726–2014 |
| Brand | Sundhy |
|---|---|
| Origin | Hunan, China |
| Model | SDTGA1200 |
| Sample Mass Range | 0.5–1.1 g (user-definable) |
| Furnace Temperature Range | Ambient to 1000 °C |
| Number of Samples per Run | 18 |
| Temperature Control Accuracy | ±2 °C |
| Full Industrial Analysis Cycle Time | ≤8 h for 54 samples (3 batches) |
| Max Power Consumption | 5.5 kW |
| Supply Voltage | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Balance Resolution | 0.1 mg |
| Compliance | GB/T 212–2008, GB/T 30732–2014, ASTM D5142–2009 |
| Brand | Sundy |
|---|---|
| Model | SDLM1250 |
| Origin | Hunan, China |
| Type | Fixed-mount 3D LiDAR-based coal stockpile volume measurement system |
| Measurement Range | 250 m |
| Scan Angle | 360° horizontal, ±30° vertical (typical) |
| Accuracy | <0.3% relative error |
| Measurement Time per Stack | ≤20 min (for up to 100,000 m³ pile, coverage area 280 × 60 m) |
| Data Acquisition Interval | ≥10 ms |
| Response Time | ≤20 s |
| Operating Temperature | −40 °C to +70 °C |
| Power Supply | 24 V DC ±15% |
| Total Power Consumption | 36 W (scanner), 140 W (heating unit) |
| Ingress Protection | IP67 |
| Mounting | Integrated with stacker-reclaimer or bucket-wheel stacker via rigid mechanical interface |
| Travel Sensor Compatibility | Optional encoder-based linear displacement sensor for synchronized motion compensation |
| Brand | Sundy |
|---|---|
| Model | SDLM300 |
| Origin | Hunan, China |
| Type | Portable 3D Laser-Based Volumetric Measurement System for Bulk Material Stacks |
| Volume Accuracy | ≤1.5% (V < 1000 m³), ≤1.0% (V ≥ 1000 m³) |
| Operating Temperature | −30 °C to +55 °C (laser unit: −30 °C to +60 °C) |
| Battery Life | 4 h (laser rangefinder, single battery), 3 h (rugged tablet, full charge) |
| IP Rating | IP56 |
| Drop Resistance | MIL-STD-810G compliant (tablet) |
| Laser Range | 1900 m (≥10% reflectivity), ±4 cm accuracy (typical target < 400 m) |
| Inclination Measurement | ±85°, ±0.1° resolution |
| Horizontal Angle | 0–360°, ±0.01° resolution |
| Total Unit Weight | ~3.5 kg (varies with tablet/stabilization mount) |
| Compliance | ASTM D6172 (standard practice for volumetric measurement of stockpiles), ISO 11222:2017 (geospatial data quality for volume estimation), GLP-aligned data traceability |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SDUAV |
| Pricing | Available Upon Request |
| Endurance | 40 min |
| Wind Resistance | 12 m/s |
| Camera Resolution | 20 MP |
| Volumetric Measurement Accuracy | < 0.5% |
| Ground Sampling Distance (GSD) | 4 cm |
| Operating Temperature Range | −35 °C to +50 °C |
| UAV Weight | 915 g |
| Brand | SUNJUNE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VP-TA1 |
| RF Frequency | 13.56 MHz |
| RF Power | 500 W |
| Maximum Chamber Temperature | ≤150 °C |
| Continuous Unattended Operation | ≥8 h |
| Vacuum Display | Digital Real-Time Readout |
| Gas Inlets | 2 Independent Mass-Flow-Controlled Ports |
| Control Interface | Touchscreen with Integrated Plasma Control Software (Registration No. 2021SR1026389) |
| Warranty | 2 Years Comprehensive |
| Brand | SUNJUNE |
|---|---|
| Model | VS-Q2 |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 2,800 – 12,600 |
| Vacuum Performance (Mechanical Pump Only) | < 5 Pa |
| Vacuum Performance (MPU-90i Molecular Pump Unit) | < 1×10⁻⁵ Pa (with full-range vacuum gauge) |
| Ultimate Vacuum (MPU-90i in optimized configuration) | ≤ 1×10⁻⁶ Pa |
| Quartz Tube Compatibility | OD 5–50 mm, Length 80–1500 mm |
| Rotational Speed Control | Adjustable |
| Vacuum Pumping Rate | Adjustable |
| Protective Gas Backfilling Rate | Adjustable |
| Control Interface | Touchscreen with IL Intelligent Logic Program |
| Operating Modes | Manual (independent mechanical pump control) and Auto (interlocked mechanical + molecular pump sequencing) |
| Enclosure | One-piece stainless steel housing |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Sunny Optical (SOPTOP) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MINLMJ-100 |
| Pricing | Available Upon Request |
| Dimensions (L×W×H) | 2100 × 1510 × 2100 mm |
| Weight | 2000 kg |
| Power Supply | AC 220 V |
| Power Consumption | 6500 W |
| Pneumatic Supply Pressure | 0.5 MPa |
| Z-axis Repeatability (Loading/Unloading) | ±0.05 mm |
| Z-axis Repeatability (Inspection Transfer) | ±0.02 mm |
| Y-axis Repeatability (Inspection Transfer) | ±0.01 mm |
| X-axis Repeatability (Imaging Module) | ±0.01 mm |
| Z-axis Repeatability (Imaging Module) | ±0.02 mm |
| X/Y-axis Repeatability (Buffer Stage) | ±0.01 mm |
| Y/Z-axis Repeatability (Sorting Transfer) | ±0.01 mm / ±0.02 mm |
| X/Z-axis Repeatability (Sorting Actuator) | ±0.01 mm / ±0.02 mm |
| Compatible Tray Sizes | 76 × 76 mm and 101.6 × 101.6 mm |
| Detectable Component Footprint | ≥4.5 × 4.5 mm |
| Field of View | 15 mm × 20 mm |
| Glass Surface Defect Miss Rate | <500 ppm |
| Orientation Detection Miss Rate | <100 ppm |
| Glass Surface False Call Rate | <5% |
| Orientation False Call Rate | <1% |
| Throughput (UPH) | ≥15,000 (CSP yield = 90%), ≥13,500 (CSP yield = 85%) |
| Applicable Packages | CSP and COM image sensor modules |
| Brand | Suruga Seiki |
|---|---|
| Origin | Japan |
| Model | BSS16-70CZ |
| Platform Surface | 70 × 70 mm |
| Travel Range | ±6.5 mm (13 mm total) |
| Load Capacity | 219.5 N (22.4 kgf) |
| Feed Mechanism | Standard Micrometer Head (Pitch = 0.5 mm) |
| Minimum Micrometer Resolution | 10 µm/div |
| Positioning Accuracy | Straightness ≤1 µm, Pitch ≤25″, Yaw ≤15″, Roll Parallelism ≤12 µm |
| Permissible Moment Loads | Pitch/Yaw/Roll = 12.9 / 13.8 / 12.9 N·m |
| Torque Rigidity | Pitch/Yaw/Roll = 0.09 / 0.1 / 0.09 ″/N·cm |
| Permissible Parallelism Tolerance | ≤30 µm |
| Perpendicularity Tolerance | ≤10 µm |
| Mass | 1.16 kg |
| Guide Type | Linear Ball Bearing Rail |
| Construction Material | Stainless Steel with Electroless Nickel Plating |
| Brand | Suying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer (not distributor) |
| Country of Manufacture | China |
| Model | WH-100 |
| Temperature Range – Heating Chamber | 45–160 °C |
| Temperature Range – Cooling Chamber | −28–100 °C |
| Compliance | ISO 6452, DIN 75201, SAE J1756, GB/T 27630 |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | SV10 |
| Compliance | ASTM D7157 |
| Automation | Fully Automated Dilution, Titration & Cleaning |
| Temperature Control | High-Precision Patented Thermal Regulation |
| Sample Throughput | 3 Parallel Measurement Positions |
| Solvent Handling | Sealed Enclosure, Operator-Solvent Isolation |
| Application Scope | Crude Oil, Residua, Heavy Fuel Oils, Marine Bunker Fuels |
| Brand | SWIN |
|---|---|
| Origin | Taiwan |
| Model | HL8800 |
| Operating Temperature | Ambient & Liquid Nitrogen (77 K) |
| Magnetic Field Strength | 0.65 T / 1 T (selectable) |
| Constant Current Source Range | 2 nA – 100 mA |
| Voltage Measurement Range | ±2000 V |
| Maximum Applied Voltage | 200 V |
| Carrier Concentration Range | 1 × 10⁷ – 1 × 10²¹ cm⁻³ |
| Mobility Range | 1 – 1 × 10⁷ cm²/(V·s) |
| Resistivity Range | 1 × 10⁻⁶ – 1 × 10⁷ Ω·cm |
| Sample Compatibility | Bulk and thin-film semiconductors (n- and p-type) |
| Hall Coefficient Accuracy | < ±0.5% typical |
| Voltage Resolution | ≤1 nV |
| Current Resolution | ≤2 nA |
| Dimensions (W × D × H) | 260 × 220 × 180 mm |
| Weight | 6 kg |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | SYD-2806H |
| Pricing | Upon Request |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SysNova SF1000 |
| Pricing | Available Upon Request |
| Temperature Range | Up to 1000 °C |
| Current Accuracy | ±0.03% F.S. |
| Voltage Accuracy | ±0.02% F.S. |
| Fuel Compatibility | H₂, CO, CO₂, NH₃, reformate gas mixtures |
| Cell/Stack Compatibility | Button, planar, and tubular SOFC configurations |
| Safety Features | Integrated H₂ leak detection, dual-stage thermal monitoring, emergency shutdown logic |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7101 |
| Pricing | Available Upon Request |
| Measurement Range | 0.002–70 g/(m²·d) (unmasked) |
| Temperature Control Range | 10–40 °C (50–104 °F) |
| Relative Humidity Control Range | 20–90 % RH |
| Sample Area | 50 cm² (adapters available for smaller specimens) |
| Sensor Technology | High-sensitivity Coulometric P₂O₅ sensor |
| Compliance | ASTM F3299–18 |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | 8101e |
| Test Gas | O₂ |
| RH Control Range | 0–90% ±2% |
| Temperature Control Range | 10–40°C ±0.1°C |
| Sensor Type | eMetric™ Coulometric Sensor |
| Sample Types | Flexible Films & Rigid Packaging |
| Maximum Configurable Stations | 32 |
| Operating System | Windows®-based Platform |
| Sealing Method | Q-Seal™ Chamberless Seal |
| Compliance | ASTM F2622, ASTM D3985, ISO 15105-2, ISO 1186 |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | Lyssy L80-6000 |
| WVTR Range | 0.03 – 10,000 g/m²/day (standard) |
| Test Temperature Range | 5 – 50°C |
| Relative Humidity Control Range | 5 – 60% RH |
| Ambient Humidity Tolerance | 10 – 90% RH (non-condensing) |
| Dimensions | 400 × 400 × 350 mm |
| Weight | 24 kg |
| Software | Permetrace™ |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | DIT-ASTM D1709 |
| Test Methods | ASTM D1709 (Method A & B), GB/T 9639, JIS K7124 |
| Mass Range | Method A: 50–2000 g |
| Method B | 300–2000 g |
| Resolution | 0.1 g (0.1 J) |
| Sample Clamping | Pneumatic, ≤1.1 MPa air supply required |
| Sample Size | >150 mm × 150 mm |
| Dimensions (A/B) | 450×450×1365 mm / 450×450×2160 mm |
| Power | AC 220 V, 50 Hz |
| Weight | 70 kg |
| Interface | Standard RS232/USB |
| Data Analysis | Built-in min/max/mean/SD calculation |
| Optional | Ball Impact Module, DSM Lab Data Management System, Safety Guard Kit |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GB 8809-1988 Pendulum Impact Tester |
| Impact Energy Options | 1 J, 2 J, 3 J, 5 J (selectable) |
| Resolution | 0.001 J |
| Impact Head Diameter | Ø25.4 mm, Ø19 mm, Ø12.7 mm |
| Clamp Aperture | Ø89 mm, Ø60 mm |
| Specimen Size | 100 mm × 100 mm or Ø100 mm |
| Pneumatic Pressure Range | 0.3–1.5 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 492 × 383 × 752 mm |
| Net Weight | 44 kg |
| Compliance | GB/T 8809–1988, ASTM D3420, NF T54-116 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GTR-7004 |
| Price Range | USD 14,000–21,500 |
| Test Range | 15–15,000 s/100 mL (standard) |
| Resolution | 0.1 s/100 mL |
| Sample Count | 1 |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Max Sample Thickness | ≤5 mm |
| Test Gas | Clean compressed air (user-supplied) |
| Air Supply Pressure | 0.3–1.0 MPa |
| Interface | Ø6 mm pneumatic fitting |
| Dimensions | 320 × 380 × 410 mm (L×D×H) |
| Power | AC 220 V, 50 Hz |
| Net Weight | 25 kg |
| Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GTR-704R |
| Test Range | 10–15,000 s/100 mL |
| Resolution | 0.1 s/100 mL |
| Sample Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Max Sample Thickness | ≤5 mm |
| Gas Supply | Clean compressed air (0.3–1.0 MPa) |
| Interface | Ø6 mm pneumatic fitting |
| Power | AC 220 V, 50 Hz |
| Dimensions | 370 × 320 × 220 mm (L×D×H) |
| Weight | 20 kg |
| Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GTR-704R |
| Test Range | 10–15,000 s/100 mL (standard) |
| Resolution | 0.1 s/100 mL |
| Specimen Count | 1 |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Max Specimen Thickness | ≤5 mm |
| Test Gas | Clean Compressed Air (user-supplied) |
| Air Supply Pressure | 0.3–1.0 MPa |
| Interface | Ø6 mm pneumatic fitting |
| Dimensions (L×D×H) | 370 × 320 × 220 mm |
| Power | AC 220 V, 50 Hz |
| Net Weight | 20 kg |
| Standards Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYSTESTER GTR-1 |
| Price Range | USD 14,000 – 28,000 |
| Test Principle | Vacuum Pressure-Difference Method |
| Test Chamber | Single-cell |
| Temperature Control | Circulating medium thermostatic control (5 °C to 95 °C, optional) |
| Temperature Accuracy | ±0.1 °C |
| Vacuum Resolution | 0.1 Pa |
| Permeation Range | 0.01–170,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Thickness Limit | ≤3 mm |
| Effective Test Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Gases | O₂, N₂, CO₂, air, He (user-supplied gas source, 0.3–1.0 MPa) |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Compliance Standards | GB/T 1038–2000, ISO 15105-1, ISO 2556, ASTM D1434, JIS K 7126-1, YBB 00082003 |
| Software Features | Audit trail, system logging, 5-level user permission management, DSM LIMS integration (optional) |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Jinan SYSTESTER Heat Sealing Tester |
| Price Range | USD 4,200 – 7,000 |
| Touchscreen Interface | Industrial TFT LCD |
| UI Design | Zero-navigation-depth flat interface |
| Temperature Control | Dual independent sealing bars |
| Max Operating Temperature | 300 °C |
| Temp Range | RT + 6 °C to 300 °C |
| Temp Accuracy | ±0.2 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.05–1.1 MPa |
| Sealing Area | 265 mm × 12 mm (customizable) |
| Sealing Mode | Dual-bar independent control |
| Pneumatic Interface | Ø6 mm |
| Air Supply Requirement | 0.05–1.1 MPa (user-supplied) |
| Dimensions (L×W×H) | 410 × 396 × 416 mm |
| Weight | 33 kg |
| Power | AC 220 V, 50 Hz |
| Safety Features | Emergency stop button, anti-scald housing, fanless design |
| Noise Level | <35 dB(A) |
| Standard Compliance | QB/T 2358 (equivalent to ZBY 28004), ASTM F2029, YBB00212005-2015 |
| Data Output | Integrated thermal printer |
| Communication Interface | Standard RS232/USB |
| Optional Integration | DSM Laboratory Data Management System (sold separately) |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | Membrane Separation Performance Evaluation System |
| Test Range | 0.01–2×10⁴ Barrer |
| Gas Flow Rate | 0–100 mL/min (200/300 mL/min optional) |
| Measurement Accuracy | ±0.01 Barrer |
| Vacuum Accuracy | ±0.1 Pa |
| Test Pressure Differential | 0–10 bar (system rated to 16 bar) |
| Temperature Control Range | 5–95 °C (±0.1 °C with optional chiller/heater) |
| Effective Test Area | Φ20 mm (3.14 cm²) |
| Sample Thickness Limit | ≤2 mm |
| Sample Capacity | 1 specimen per run |
| Detector Sensitivity | ≥5000 or 10000 mV·mL/mg (configurable) |
| Baseline Drift | ≤0.10 mV |
| Noise | ≤0.015 mV |
| Carrier Gas Pressure | 2 bar |
| Compatible Carrier Gases | N₂, H₂, He, Ar |
| Dimensions (Host) | 320 × 625 × 335 mm (W×D×H) |
| (GC Unit) | 590 × 480 × 500 mm (L×W×H) |
| Power Supply | AC 220 V, 50 Hz |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OX2/231 |
| Price Range | USD 28,000 – 42,500 |
| Measurement Principle | Coulometric Sensor (ISO 15105-2 Compliant) |
| Test Method | Isobaric Equal-Pressure Mode |
| Chambers | 3 Independent Testing Cells |
| Temperature Control Range | 5–95 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control | 0%RH, 35–90%RH (±1%RH accuracy) |
| Film OTR Range | 0.01–6500 cm³/m²·d (standard), up to 63,000 cm³/m²·d (optional) |
| Container OTR Range | 0.0001–62 cm³/pkg·d |
| Film Resolution | 0.001 cm³/m²·d |
| Container Resolution | 0.00001 cm³/pkg·d |
| Test Area | 48 cm² |
| Sample Size (Film) | ≥150 mm × 94 mm or circular |
| Sample Size (Container) | ≤Φ120 mm × 400 mm (H) |
| Max. Thickness | 3 mm |
| Carrier Gas | 99.999% High-Purity N₂ |
| Flow Rate | 0–200 mL/min |
| Interface | 1/8″ Stainless Steel Tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 730 × 590 × 350 mm |
| Net Weight | 56 kg |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 |
| Software | Embedded Win-based Control & Analysis Suite with Audit Trail, Multi-level User Access (5 tiers), Real-time Curve Logging (T, RH, Flow, OTR), Optional DSM Laboratory Data Management System Integration |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QBT 2411 |
| Price Range | USD 18,000 – 24,500 |
| Test Principle | Gravimetric Cup Method |
| Test Range | 0.001–220 µg/(m²·s) |
| Permeability Range | 1×10⁻³–40,000 ng/(m²·s·Pa) |
| Sample Capacity | 6 independent stations |
| Weight Resolution | 0.0001 g |
| WVTR Resolution | 0.00001 µg/(m²·s) |
| Temperature Range | 15–55 °C (±0.1 °C control accuracy) |
| Humidity Range | 10–95 %RH (±1 %RH control accuracy |
| Air Sweep Velocity | 0.5–2.5 m/s |
| Specimen Thickness Limit | ≤25 mm |
| Test Area | 33.17 cm² |
| Specimen Diameter | Φ81 mm |
| Chamber Volume | 36 L |
| Air Supply | Compressed air, 0.2–1.0 MPa, Φ8 quick-connect fitting |
| Power | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 650 × 550 × 475 mm |
| Net Weight | 67 kg |
| Compliance | GB/T 1037, QB/T 2411–1998 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | TSL-1002 |
| Load Capacity Options | 50 N, 100 N, 250 N, 500 N, 1000 N, 2000 N |
| Test Speed Range | 0.1–1000 mm/min (software-controlled, infinitely variable) |
| Stroke | 1000 mm |
| Displacement Resolution | 0.01 mm |
| Clamp Width (standard) | 30 mm |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 300 W |
| Dimensions (L×W×H) | 380 × 450 × 1309 mm |
| Net Weight | 92 kg |
| Accuracy Class | Better than Grade 0.5 |
| Compliance Standards | GB/T 3923.1–2013, GB/T 17200, ISO 37, ASTM D882, ASTM D1938, ASTM F88, EN ISO 11600, JIS P8113 |
| Brand | T/A |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FP-2260 |
| Price Range | USD 14,000 – 70,000 |
| Standards Compliance | ASTM D1894, D4521, D3330, F88 |
| Load Cell Options | 0.5 kg, 1 kg, 2 kg, 10 kg |
| Resolution | 0.1 g |
| Accuracy | ±0.25% of full scale |
| Force Units | g, kg, oz, lb, N |
| Test Speed | Standard: 1–20 in/min |
| High-Speed | 10–110 in/min |
| Standard Sled Masses | 200 g, 500 g, 1000 g, 3 lb |
| Test Duration | 0.1–99 s |
| Travel Distance | 0.1–14.0 in |
| Display | 240 × 64 pixel LCD |
| Data Storage | 127 test records |
| Test Area | 225 mm × 350 mm |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 27 in × 12 in × 7 in |
| Weight | 20 kg |
| Brand | T&R |
|---|---|
| Origin | United Kingdom |
| Model | 750ADM MK4 |
| Output Capacity | 750 A (primary), 40 A / 16 V (secondary) |
| Open-Circuit Voltage | 5.0 V (230 V supply) |
| Continuous Current Rating | 125 A |
| Short-Term Current Rating | 750 A for 20 s (230 V) |
| True RMS Measurement Accuracy | ±0.5% rdg + 2–5 digits |
| Timing Resolution | 1 ms |
| Timing Accuracy | ±0.01% rdg + 2d (conventional mode) |
| Storage | USB-based CSV logging with real-time clock timestamping |
| Safety Compliance | BS EN 61010-1, UKCA certified |
| Dimensions (metal enclosure) | 560 × 456 × 265 mm |
| Weight | 27.4 kg |
| Power Input | Auto-ranging 115 V / 230 V ±10%, 50/60 Hz, single-phase |