Industry-specific Instruments
Filter
Showing 2131–2160 of 6344 results
| Brand | HARKE |
|---|---|
| Model | HK-G6 |
| Measurement Principle | Vacuum Method (Manometric) |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ |
| Permeation Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (±0.1 °C) |
| Sample Area | 48 cm² |
| Max Sample Thickness | ≤5 mm |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Chamber | Single independent chamber (configurable to triple-chamber system) |
| Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Power | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions | 330 × 600 × 330 mm (L×D×H) |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HK-GR3 |
| Quotation | Available upon request |
| Measurement Principle | Vacuum-based differential pressure method |
| Test Range | 0.05–160,000 cm³/m²·24h·0.1MPa (standard configuration) |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Specimen Count | 1 |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5°C–95°C (external chiller/heater required) |
| Temperature Accuracy | ±0.1°C |
| Max Specimen Thickness | ≤5 mm (customizable) |
| Specimen Dimensions | ≥150 mm × 94 mm or circular |
| Effective Test Area | 48 cm² |
| Test Gases | O₂, N₂, CO₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (user-supplied gas sources) |
| Test Pressure Range | −0.1 MPa to +0.1 MPa (standard) |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Brand | HARKE |
|---|---|
| Model | HK-O-3 |
| Type | Gas Permeability Tester (O₂, CO₂, N₂, Air, He) |
| Origin | Beijing, China |
| Manufacturer | HARKE Instrument Co., Ltd. |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 730 × 590 × 350 mm |
| Net Weight | 56 kg |
| Test Area | 50 cm² |
| Sample Thickness Limit | ≤5 mm |
| Temperature Range | 5–95 °C (±0.1 °C accuracy) |
| Humidity Control | 0 %RH, 35–90 %RH, 100 %RH (±1 %RH accuracy) |
| OTR Range (Film) | 0.01–6500 cm³/m²·d (standard), 0.05–65000 cm³/m²·d (optional) |
| OTR Range (Container) | 0.0001–65 cm³/pkg·d (standard) |
| Resolution (Film) | 0.001 cm³/m²·d |
| Resolution (Container) | 0.00001 cm³/pkg·d |
| Sample Capacity | 1–3 independent stations |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Carrier Flow | 0–200 mL/min |
| Gas Inlet | 1/8″ stainless steel tubing |
| Test Gases | O₂, CO₂, N₂, air, He (user-supplied) |
| Sample Format | Flat films (≥150 mm × 94 mm or circular), containers (≤Φ120 mm × 400 mm H) |
| Brand | HARKE |
|---|---|
| Model | HK-O2 |
| Type | Gas Permeability Tester (O₂) |
| Origin | Beijing, China |
| Manufacturer | HARKE Instrument Co., Ltd. |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Measurement Principle | Vacuum Method (Manometric) |
| Test Gases | O₂, N₂, CO₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ |
| Temperature Range | 5–95 °C (optional chamber) |
| Temp. Accuracy | ±0.1 °C |
| RH Control | 0%, 35–90%, 100% RH |
| RH Accuracy | ±1% RH |
| Film OTR Range | 0.01–2500 cm³/m²·d (standard), up to 25,000 cm³/m²·d (optional) |
| Container OTR Range | 0.0001–25 cm³/pkg·d |
| Resolution (Film) | 0.001 cm³/m²·d |
| Resolution (Container) | 0.00001 cm³/pkg·d |
| Sample Area | 50 cm² |
| Sample Quantity | 3 specimens (averaged) |
| Max. Specimen Size (Film) | ≥150 mm × 94 mm or circular |
| Max. Specimen Size (Container) | ≤Φ120 mm × 400 mm (H) |
| Max. Thickness | ≤5 mm |
| Carrier Gas | 99.999% high-purity N₂ |
| Carrier Flow | 0–200 mL/min |
| Interface | 1/8″ stainless steel tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 730 × 590 × 350 mm |
| Net Weight | 56 kg |
| Gas Source | User-supplied (including hazardous gases — pre-order notification required) |
| Brand | HARKE |
|---|---|
| Model | HK-O3 |
| Application | Vacuum-Method Gas Permeability Testing for Packaging & Barrier Materials |
| Measurement Principle | Differential Pressure (Vacuum Method) per ISO 15105-1 & ASTM D1434 |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, NH₃, etc. |
| OTR Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temp. Stability | ±0.1 °C |
| Specimen Area | 48 cm² |
| Max. Thickness | ≤5 mm |
| Specimen Size | ≥150 mm × 94 mm or circular |
| Test Chamber | Single cavity, pneumatically clamped |
| Operating Pressure Range | –0.1 to +0.1 MPa |
| Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet | Ø8 mm |
| Dimensions | 330 × 600 × 330 mm (L×D×H) |
| Weight | 28 kg |
| Power | AC 220 V, 50 Hz |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HK-R3 |
| Pricing | Upon Request |
| Brand | Harke |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Harke Instrument Co., Ltd. |
| Model | HK-R7 |
| Temperature Control Range | 5 °C to 95 °C (external chiller required) |
| Temperature Accuracy | ±0.1 °C |
| Vacuum Resolution | 0.1 Pa |
| Test Area | 48 cm² |
| Sample Thickness Limit | ≤5 mm (customizable) |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Gas Permeation Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Test Gases | O₂, N₂, CO₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-order specification) |
| Operating Pressure Range | −0.1 to +0.1 MPa |
| Supply Pressure | 0.3–1.0 MPa |
| Inlet Port | Ø8 mm |
| Power | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions | 330 mm (L) × 600 mm (D) × 330 mm (H) |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Model | HK-T-391 |
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Measurement Range | 1×10⁻⁵ – 1×10⁻¹⁴ cm³(STP)·mm/cm²·s·cmHg |
| Test Method | TCD Detection + Chromatographic Calibration Curve |
| Max Sample Thickness | ≤1 mm |
| Detection Sensitivity | ≥3000 mV·mL/mg (for benzene & H₂) |
| Test Area | 50 cm² |
| Sample Capacity | 1 standard specimen (multi-specimen option available) |
| Test Chamber Temp. Range | 5–95 °C |
| Temp. Control Accuracy | ±0.1 °C |
| Carrier Gas Line Temp. Range | RT+5–100 °C |
| Carrier Gas | He or H₂ (selectable) |
| Carrier Pressure | 0.05–0.5 MPa |
| Test Gas Pressure Differential | −0.1 to +0.1 MPa |
| Vacuum Level in Test Chamber | <20 Pa |
| Applicable Gases | Air, O₂, N₂, CO, CO₂, CH₄, H₂, He, NH₃, C₃H₈, C₄H₁₀ (custom gases available |
| Dimensions | 330 × 380 × 410 mm (L×W×H) |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 46 kg |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Model | HK-T03 |
| Type | Vacuum-Method Gas Permeability Tester for Films and Containers |
| Measurement Principle | Coulometric Sensor Detection (ASTM D3985 / ISO 15105-2 Compliant) |
| OTR Range (Film) | 0.01–6500 cm³/m²·d (Standard), 0.05–65,000 cm³/m²·d (Optional) |
| OTR Range (Container) | 0.0001–65 cm³/pkg·d (Standard) |
| Resolution (Film) | 0.001 cm³/m²·d |
| Resolution (Container) | 0.00001 cm³/pkg·d |
| Temperature Control Range | 5–95 °C (External Chiller Required) |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control | 0% RH, 35–90% RH, 100% RH |
| RH Accuracy | ±1% RH |
| Test Area | 50 cm² |
| Sample Thickness Limit | ≤5 mm |
| Sample Dimensions (Film) | ≥150 mm × 94 mm or circular |
| (Container) | ≤Φ120 mm × 400 mm (H) |
| Carrier Gas | 99.999% high-purity N₂ |
| Carrier Flow Rate | 0–200 mL/min |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Net Weight | 28 kg |
| Gas Compatibility | O₂, CO₂, N₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-installation safety review) |
| Brand | HARKE |
|---|---|
| Model | HK-T103 |
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Measurement Range | 0.01–10⁴ Barrer |
| Resolution | 0.01 Barrer |
| Test Pressure | 0–101 kPa (standard), ±101 kPa (optional) |
| Mass Flow Rate | 0–20 mL/min (standard), 0–200 mL/min (optional) |
| Sample Thickness | ≤2 mm |
| Test Area | 4.9 cm² |
| Sample Capacity | 1 specimen |
| Temperature Control Range | 5–95 °C (±0.1 °C accuracy |
| Humidity Control Range | 0%, 35–90%, 100% RH (±1% RH accuracy |
| Compatible Gases | Air, O₂, N₂, CO₂, He (standard) |
| Gas Inlet | Φ6 mm push-to-connect |
| Dimensions (L×W×H) | 335 × 610 × 340 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 30 kg |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HK-T700 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Domestic Product | Yes |
| Model | HK-V3 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HK-W2 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Model | HK-X3 |
| Measurement Principle | Vacuum Method (ASTM D1434, ISO 2556, ISO 15105-1) |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, NH₃, C₃H₈, C₄H₁₀ (hazardous gases require pre-order specification) |
| Permeation Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temp. Stability | ±0.1 °C |
| Sample Thickness | ≤5 mm (customizable) |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Chamber | Single independent cavity |
| Pressure Range | −0.1 to +0.1 MPa |
| Supply Pressure | 0.3–1.0 MPa |
| Inlet Port | Ø8 mm |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Weight | 28 kg |
| Power | AC 220 V, 50 Hz |
| Brand | HARKE |
|---|---|
| Model | HK-XR-14 |
| Standard Compliance | GB/T 8301–2008, SH/T 1151–1998 |
| Stirring Speed | 14,000 ± 200 rpm |
| Temperature Control Range | 35 ± 1 °C (during test) |
| Stirrer Disc Diameter Options | 36.12 ± 0.03 mm (synthetic latex), 20.83 ± 0.03 mm (natural latex) |
| Resolution | 1 rpm |
| Display | LED via frequency converter |
| Power Supply | 220 V ± 10 %, 50 Hz, 1500 W |
| Dimensions | 400 × 350 × 720 mm |
| Operating Environment | 10–40 °C, <85 % RH |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HK-XR-14Q |
| Price | Upon Request |
| Stirring Speed | 14,000 rpm ± 200 rpm |
| Temperature Control Range | 35 °C ± 1 °C (sample) |
| Operating Ambient | 10–40 °C, <85% RH |
| Stirrer Disc Diameter (Natural Rubber Latex) | 20.83 ± 0.03 mm |
| Stirrer Disc Diameter (Synthetic Rubber Latex) | 36.12 ± 0.03 mm |
| Disc Thickness | 1.57 ± 0.05 mm |
| Stirrer Tip Diameter | 6.3 mm |
| Sample Container | Cylindrical Glass Vessel (ID 58 mm, OD 63 mm, H > 100 mm) |
| Speed Resolution | 1 rpm |
| Speed Accuracy | ≤0.1% |
| Max Speed | 20,000 rpm |
| Min Speed | 2,000 rpm |
| Power Supply | 220 V ±10%, 50 Hz, 1500 W |
| Dimensions (W×D×H) | 400 × 350 × 720 mm |
| Cooling System | Integrated Water Circulation Pump |
| Brand | HARKE |
|---|---|
| Model | HK-XR-14W |
| Standard Compliance | GB/T 8301–2008, SH/T 1151–1998 |
| Rotational Speed | 14,000 ± 200 rpm |
| Temperature Control Range | 35–37 °C |
| Sample Mass | 80 g (pre-conditioned at 55% total solids) |
| Test Endpoint Detection | Visual coagulum onset via palm test or water dispersion test |
| Power Supply | 220 V AC, 50 Hz |
| Brand | HARKE |
|---|---|
| Model | XR-14 |
| Application | Mechanical stability testing of natural and synthetic latex |
| Compliance | ISO 2006 |
| Speed Range | 3,000–20,000 rpm (preset at 14,000 ± 200 rpm) |
| Speed Stability | ≤ ±100 rpm at 14,000 rpm |
| Stirring Disc Dimensions | Natural latex disc: Ø20.83 ± 0.03 mm × 1.57 ± 0.05 mm |
| Synthetic latex disc | Ø36.12 ± 0.03 mm × 1.58 ± 0.05 mm |
| Sample Container | ID 58 ± 0.25 mm × H 127 mm, wall thickness 2.5 mm |
| Disc-to-Bottom Distance | 13 ± 1 mm |
| Power Supply | 220 V ± 10%, 5 A |
| Operating Temperature | 10–40 °C |
| pH Compatibility | 1–14 |
| Cooling Option | Optional circulating water jacket (inlet/outlet ports provided) |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HARKE-XR-14 |
| Price | Upon Request |
| Operating Temperature Range | 10–40 °C |
| Relative Humidity Limit | <85% RH |
| Stirring Speed | 14,000 rpm ±200 rpm |
| Speed Resolution | 1 rpm |
| Speed Accuracy | ≤0.1% FS |
| Max Speed | 20,000 rpm |
| Min Speed | 2,000 rpm |
| Power Supply | 220 V ±10%, 50 Hz, 1500 W |
| Dimensions (W×D×H) | 400 mm × 350 mm × 720 mm |
| Sample Container | Cylindrical borosilicate glass vessel (ID 58 mm, OD 63 mm, height >100 mm) |
| Stirrer Tip Diameter | 6.3 mm |
| Stirring Discs | Two interchangeable discs — Type A (Ø20.83 mm ±0.03 mm, thickness 1.57 mm ±0.05 mm) for natural rubber latex |
| Integrated Cooling Pump | Yes |
| Display | LED via frequency converter interface |
| Compliance Standards | GB/T 8301–2008, SH/T 1151–1998 |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | XR-14G |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | XR-14GT |
| Pricing | Upon Request |
| Speed Range | 3,000–20,000 rpm |
| Speed Stability at 14,000 rpm | ±100 rpm |
| Stirring Disk Dimensions (Natural Latex) | Ø20.83 ±0.03 mm × 1.57 ±0.05 mm |
| Stirring Disk Dimensions (Synthetic Latex) | Ø36.12 ±0.03 mm × 1.58 ±0.05 mm |
| Sample Container | Height 127 mm, ID 58 ±0.25 mm, Wall Thickness 2.5 mm |
| Disk-to-Bottom Distance | 13 ±1 mm |
| Operating Voltage | 220 V ±10%, 5 A |
| Ambient Temperature Range | 10–40 °C |
| Compatible Media | Natural or synthetic latex, pH 1–14 |
| Cooling Option | Circulating water cooling (optional, activated at ≥60 °C component temperature) |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XR-14R |
| Price | Upon Request |
| Speed Range | 3,000–20,000 rpm (preset at 14,000 ± 200 rpm) |
| Speed Stability | ≤ ±100 rpm at 14,000 rpm |
| Stirring Disk Dimensions (Natural Latex) | Ø20.83 ± 0.03 mm × 1.57 ± 0.05 mm |
| Stirring Disk Dimensions (Synthetic Latex) | Ø36.12 ± 0.03 mm × 1.58 ± 0.05 mm |
| Sample Container | ID 58 ± 0.25 mm, Height 127 mm, Wall Thickness 2.5 mm |
| Disk-to-Bottom Distance | 13 ± 1 mm |
| Operating Voltage | 220 V ± 10%, 5 A |
| Ambient Temperature Range | 10–40 °C |
| Compatible Media | Natural or synthetic latex, pH 1–14 |
| Cooling Interface | Dual-port water circulation connection for motor thermal management |
| Brand | HARKE |
|---|---|
| Model | XR-14RT |
| Application | Mechanical stability testing of natural and synthetic latex |
| Compliance | ISO 2006 |
| Speed Range | 3,000–20,000 rpm (standard test speed: 14,000 ± 200 rpm) |
| Speed Stability | ≤ ±100 rpm at 14,000 rpm |
| Stirring Disk Dimensions (Natural Latex) | Ø20.83 ± 0.03 mm × 1.57 ± 0.05 mm |
| Stirring Disk Dimensions (Synthetic Latex) | Ø36.12 ± 0.03 mm × 1.58 ± 0.05 mm |
| Sample Container | ID 58 ± 0.25 mm × H 127 mm, wall thickness 2.5 mm |
| Disk-to-Bottom Distance | 13 ± 1 mm |
| Power Supply | 220 V ± 10%, 5 A |
| Operating Temperature | 10–40 °C |
| pH Compatibility | 1–14 |
| Cooling Option | Optional recirculating water cooling (activated at ≥60 °C motor surface temperature) |
| Brand | HARKE |
|---|---|
| Model | XR-14S |
| Origin | Beijing, China |
| Manufacturer | HARKE Instrument Co., Ltd. |
| Application | Mechanical stability testing of natural and synthetic latex per ISO 2006 |
| Speed Range | 3,000–20,000 rpm (standard test speed: 14,000 ± 200 rpm) |
| Speed Stability | ≤ ±100 rpm at 14,000 rpm |
| Stirring Disk Dimensions | Natural latex disk: Ø20.83 ± 0.03 mm × 1.57 ± 0.05 mm |
| Synthetic latex disk | Ø36.12 ± 0.03 mm × 1.58 ± 0.05 mm |
| Container | Internal diameter 58 ± 0.25 mm, height 127 mm, wall thickness 2.5 mm |
| Disk-to-Bottom Distance | 13 ± 1 mm |
| Power Supply | 220 V ± 10%, 5 A |
| Operating Temperature | 10–40 °C |
| Compatible Media | Natural or synthetic latex, pH 1–14 |
| Cooling Option | Optional recirculating water cooling (inlet/outlet ports provided) |
| Brand | HARKE |
|---|---|
| Model | XR-14T |
| Origin | Beijing, China |
| Manufacturer | HARKE Instrument Co., Ltd. |
| Type | Domestic Production |
| Speed Range | 3,000–20,000 rpm (standard test speed: 14,000 ± 200 rpm) |
| Stirring Disk Dimensions (Natural Latex) | Ø20.83 ± 0.03 mm × 1.57 ± 0.05 mm |
| Stirring Disk Dimensions (Synthetic Latex) | Ø36.12 ± 0.03 mm × 1.58 ± 0.05 mm |
| Container Internal Diameter | 58 ± 0.25 mm |
| Container Height | 127 mm |
| Wall Thickness | 2.5 mm |
| Disk-to-Bottom Distance | 13 ± 1 mm |
| Power Supply | 220 V ± 10%, 5 A |
| Operating Temperature | 10–40 °C |
| pH Compatibility | 1–14 |
| Cooling Option | Circulating water jacket (optional) |
| Compliance | ISO 2006 |
| Brand | UNION |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TLD 4500 |
| Pricing | Available Upon Request |
| Brand | UNION |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TLD 5500 |
| Pricing | Available Upon Request |
| Brand | UNION |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TLD 660 |
| Price Range | USD 27,000 – 41,000 |
| Brand | UNION |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TLD 8800 |
| Price Range | USD 1,400 – 7,200 |
| Brand | Hartek |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HTBS-20A |
| Price Range | USD 14,000 – 28,000 |
| Screw Diameter | 20 mm |
| L/D Ratio | 28:1 |
| Max Screw Speed | 120 rpm |
| Heating/Cooling | Electric Heating / Air Cooling |
| Max Barrel Temperature | 350 °C |
| Temperature Control Accuracy | ±1.0 °C |
| Melt Pressure Range | 0–35 MPa |
| Melt Pressure Accuracy | ±0.2 % F.S. |
| Haul-off Speed | 0–8 m/min (infinitely variable) |
| Film Lay-flat Width | 160 mm |
| Net Weight | 503 kg |
| Overall Dimensions (L×W×H) | 2980 × 944 × 2630 mm |