Industry-specific Instruments
Filter
Showing 2101–2130 of 6344 results
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | SOA600 |
| Type | Intelligent Automated SO₂ Distillation System |
| Max. Sample Capacity | 6 channels |
| Distillation Time Range | 1–999 min |
| N₂ Flow Rate | 50–2000 mL/min per channel |
| Distillation Flask Volume | 1000 mL |
| Power per Channel | 0–500 W |
| Total Rated Power | 3100 W |
| Dimensions (W×D×H) | 970 × 500 × 470 mm |
| Net Weight | 75 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Region | Domestic (China) |
| Model | W100 |
| Pricing | Available Upon Request |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Model | CD14 |
| Instrument Type | Offline Dissolution Tester |
| Vessel Capacity | 14 vessels |
| Temperature Range | 25.0–50.0 °C |
| Temperature Accuracy | ±0.1 °C (at 37 °C) |
| Rotational Speed Range | 25–250 rpm |
| Speed Accuracy | ±1 rpm |
| Display Resolution | 0.1 rpm |
| Compliance | USP <711>, <724>, EP 2.9.3, JP XVII, ChP, ASTM E2503, FDA Mechanical Calibration Guidance, 21 CFR Part 11 |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Flodex |
| Pricing | Available Upon Request |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | G2 Autoplus / G2 Autofill |
| Instrument Type | Online Integrated Sampler & Collector |
| Compliance | FDA 21 CFR Part 11, USP <711>, <724>, ISO 9001, CE, CSA, RoHS |
| Sampling Channels | 6 or 8 (Autoplus) |
| Sampling Accuracy | ±1% |
| Minimum Sampling Interval | 2 min (down to 1 min under controlled conditions) |
| Maximum Sample Points per Run | 50 |
| Syringe Volumes | 5 mL or 10 mL (inert fluid path) |
| Valve Configuration | 4-channel solenoid manifold (expandable to 16- or 24-position dissolution systems) |
| Control Interface | Full-color capacitive touchscreen |
| Program Storage | Up to 100 user-defined dissolution methods |
| Connectivity | USB 2.0, RS-232, Ethernet |
| Regulatory Features | Audit trail, electronic signatures, calibration/ maintenance prompts, solvent replenishment & auto-rinse protocols |
| Rack Compatibility | 16×100 mm UV cuvette racks, 12×32 mm HPLC vials, 12×32 mm UPLC vials, 6×8 multi-position trays |
| Integrated Filtration | In-line sterile-grade filtration module |
| Software Architecture | 32-bit embedded control firmware with deterministic real-time sampling logic |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PHOENIX DB-6 |
| Pricing | Available Upon Request |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PHOENIX RDS |
| Pricing | Upon Request |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Model | Vision G2 Elite 8 / Vision G2 Classic 6 |
| Instrument Type | Offline Dissolution Tester |
| Number of Vessels | 6 or 8 |
| Temperature Range | 25–55 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.01 °C |
| Rotational Speed Range | 25–250 rpm |
| Speed Accuracy | ±1 rpm |
| Basket/Paddle Wobble | 0 mm |
| Bath Volume | 11.4 L (Classic 6) / 18.9 L (Elite 8) |
| Compliance | Fully compliant with 21 CFR Part 11 |
| Data Interface | RS232, USB, LAN |
| Onboard Storage | Up to 100 programmable dissolution methods |
| Power Supply | 220 V AC, 50–60 Hz, 65 W |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Daxluot-M4 |
| Power Supply | DC 24 V, 4 A |
| Rated Power | 60 W |
| Display | LCD |
| Timing Range | 1–9999 s |
| Rotational Speed | 4000 rpm |
| Throughput | 5 mL × 2 (standard) |
| Noise Level | <54 dB(A) |
| Final Particle Size | ≤1 µm |
| Grinding Media Options | Stainless Steel, Chrome Steel, Zirconia, Tungsten Carbide, Quartz Sand |
| Safety Lock | Integrated |
| Grinding Mode | Dry or Wet |
| Motion Principle | 3D Horizontal Orbital Vibration |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HNCX-1500 |
| Max. Power | 1500 W |
| Operating Frequency | 20 kHz |
| Input Voltage | 220 V / 50 Hz (optional 110 V) |
| Amplitude Range | 10–100% |
| Sample Volume Capacity | 10–1000 mL |
| Probe Diameter Options | Φ10 / Φ15 / Φ20 mm |
| Probe Material | Titanium Alloy |
| Temperature Control | Jacketed Processing Chamber (compatible with external chiller) |
| Chamber Material | Stainless Steel or Borosilicate Glass (customizable) |
| Cooling Interface | Standardized coolant ports |
| Safety Features | Overtemperature and fault alarms |
| Display | Touchscreen interface |
| Communication | RS485/RS232 |
| Software | PC-based control & data logging suite |
| Acoustic Enclosure | Optional sound-dampening cabinet or benchtop mount |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HY-779L |
| Pricing | Available Upon Request |
| Measurement Range | 0–2×10¹³ Ω |
| Resolution | 100 Ω |
| Accuracy | ≤ ±3% of full scale |
| Test Voltage | 100 V ± 3 V |
| Power Supply | AC 220 V ± 10%, 15 W |
| Compliance | GB/T 12014–2009 Clause 4.1.2 |
| Standard Electrode | Dual-weighted stainless-steel point-to-point electrode set (2.5 kg per electrode) |
| Calibration | NIST-traceable calibration certificate provided |
| Brand | Haosoo |
|---|---|
| Origin | Shandong, China |
| Model | D08 |
| Instrument Type | Offline Dissolution Tester |
| Actuation | 8-channel precision syringe pumps |
| Control Interface | 7-inch HD color touchscreen (Android OS) |
| Connectivity | USB, RS232, Wi-Fi |
| Sample Handling | 128-position 10 mL tube rack & 1.5 mL vial rack |
| Compliance Features | Audit trail, multi-level user permissions, fingerprint authentication |
| Thermal Control | Individual cup temperature sensing with calibration, real-time PID-controlled heating |
| Safety | Auto self-test, preheating, liquid level monitoring, dual overheat protection |
| Optional | Integrated camera system |
| Brand | Haosoo |
|---|---|
| Origin | Shandong, China |
| Model | DC300 |
| Instrument Type | Offline Degasser |
| Heating Temperature Range | Ambient to 45 °C |
| Flow Rate | 1 L/min |
| Oxygen Residual | ≤2.8 mg/L |
| Dispensing Accuracy | ≤±1% |
| Integrated Precision Weighing Module | Yes |
| Solvent Compatibility | Aqueous media (pH 1–14), surfactant-containing solutions, purified water |
| External Pure Water Feed Interface | Yes |
| Operating Modes | Single-vessel, Multi-vessel, Fixed-volume dispensing |
| Brand | Haosoo |
|---|---|
| Origin | Shandong, China |
| Model | DT06 |
| Type | Offline Dissolution Tester |
| Display | 7-inch HD color touchscreen (Android OS) |
| Connectivity | USB port + Wi-Fi interface |
| Temperature Control | High-precision real-time thermostatic control with calibration function |
| Safety Features | Power-on self-test, automatic preheating, multi-level overheat protection |
| Mechanical Design | Low-profile head assembly with integrated sealed cup lid |
| Sanitation | Built-in bacteriostatic device in recirculating tubing |
| Software | Method editing, storage and recall |
| Compliance Support | Designed to support 21 CFR Part 11-compliant workflows (with optional software configuration), GLP/GMP-aligned data integrity architecture |
| Brand | Haosoo |
|---|---|
| Origin | Shandong, China |
| Model | DT08 |
| Instrument Type | Offline Dissolution Tester |
| Operating System | Android-based UI on 7-inch HD color touchscreen |
| Connectivity | USB 2.0, RS-232, Wi-Fi |
| Temperature Control | Independent real-time cup-wise temperature monitoring with calibration capability |
| Safety Features | Auto self-diagnosis, preheating sequence, liquid-level sensing, dual-stage overheat protection |
| Data Management | Built-in thermal printer, audit trail, multi-level user authentication (including fingerprint unlock) |
| Optional | Integrated high-resolution dissolution video capture system |
| Regulatory Support | Designed to support 21 CFR Part 11-compliant workflows via software configuration |
| Brand | Haosoo |
|---|---|
| Origin | Shandong, China |
| Model | DT12 |
| Instrument Type | Offline Dissolution Tester |
| Dissolution Vessels | 12 × 1000 mL |
| Temperature Control Range (Bath) | Ambient to 55 °C |
| Bath Temperature Resolution | 0.01 °C |
| Bath Temperature Accuracy | ±0.2 °C |
| Rotational Speed Range | 1–300 rpm |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Volume | 40 L |
| Integrated Peristaltic/Syringe Pumps | 12 high-precision syringe pumps |
| Sample Collection Capacity | 192 × 10 mL tubes + optional 1.5 mL vial tray |
| User Interface | 7-inch HD color touchscreen with Android OS |
| Connectivity | USB, RS232, Wi-Fi |
| Compliance Features | Audit trail, multi-level user permissions, biometric fingerprint login |
| Safety | Emergency stop button, auto-level detection, overheat protection, self-diagnostic startup, real-time vessel temperature monitoring with calibration function |
| Brand | Haosoo |
|---|---|
| Origin | Shandong, China |
| Model | DT12 |
| Type | Offline Dissolution Tester |
| Configuration | 12-Vessel System with Dual Independent Zones (6+6) |
| Control Interface | 7-inch HD Color Touchscreen (Android OS) |
| Connectivity | USB, RS232, Wi-Fi |
| Compliance Features | Audit Trail, Multi-level User Permissions, Fingerprint Authentication |
| Safety | Emergency Stop Button, Obstruction Detection During Probe Descent, Dual Overheat Protection |
| Optional | Integrated High-Resolution Imaging Module |
| Temperature Control | Individual Vessel Real-time Monitoring with Calibration Function |
| Fluid Management | Built-in UV Sterilization in Recirculation Loop |
| Data Output | Onboard Thermal Printer, Export via USB/Network |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 010G-097 |
| Pricing | Available Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | GTR-3 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HARKE-TQ3 |
| Pricing | Upon Request |
| Measurement Principle | Differential Pressure (Manometric) Method |
| Compliant Standards | ISO 2556:1974, GB/T 1038–2000, ASTM D1434–75 |
| Permeation Rate Range (Chamber A) | 3–6000 cm³/(m²·d·Pa) |
| Permeation Rate Range (Chamber B) | 0.3–600 cm³/(m²·d·Pa) |
| Test Area | 38.46 cm² (Ø70 mm) |
| Specimen Size | 90 mm × 90 mm |
| Specimen Thickness Range | 10 µm – 2 mm |
| Test Gases | O₂, N₂, CO₂ |
| Pressure Differential Range | 0–10⁵ Pa |
| Pressure Measurement Accuracy | ±0.1 Pa |
| Power Supply | AC 220 V, 10 A |
| Control Interface | PC-based Windows software with real-time data logging, curve plotting, report generation (bilingual EN/CN), audit-ready export, and secure file management |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HK-100T |
| Pricing | Available Upon Request |
| Brand | HARKE |
|---|---|
| Model | HK-398A |
| Measurement Range | 0.01–1200 g/m²·24h (standard), up to 7500 g/m²·24h (optional) |
| Resolution | 0.001 g/m²·24h |
| Temperature Control Range | 5–95°C |
| Temperature Accuracy | ±0.1°C |
| Humidity Control | 0%RH, 35–90%RH, 100%RH |
| Humidity Accuracy | <±1%RH |
| Sample Quantity | 1–6 independent stations |
| Test Area | 38 cm² (standard) |
| Sample Dimensions | 150 mm × 94 mm or circular |
| Max Sample Thickness | ≤5 mm |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Gas Pressure | ≥0.16 MPa |
| Gas Flow Rate | 0–200 mL/min |
| Gas Inlet | 1/8″ metal tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 650 × 690 × 415 mm |
| Net Weight | 80 kg |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | HK-701M |
| Measurement Principle | Vacuum-Pressure Differential Method |
| Test Gases | O₂, CO₂, N₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ |
| Test Range | 0.01–150,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Capacity | 1–3 independent chambers |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range (optional) | 0%RH, 2–98.5%RH, 100%RH |
| Humidity Accuracy | ±1%RH |
| Max Sample Thickness | ≤5 mm |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×W×H) | 730 × 510 × 350 mm |
| Weight | 63 kg |
| Compliance | GB/T 1038–2000, ISO 15105-1, ISO 2556, ASTM D1434, JIS K 7126-1, YBB 00082003 |
| Brand | HARKE |
|---|---|
| Model | HK-701R |
| Principle | Vacuum Method (ASTM D3985, ISO 15105-2) |
| Test Range | 0.007–190,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Count | 1–3 independent stations |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH, 2–98.5% RH, 100% RH (optional humidity generator) |
| Humidity Accuracy | ±1% RH |
| Max Sample Thickness | ≤5 mm (customizable) |
| Sample Size | ≥150 mm × 94 mm or circular |
| Effective Test Area | 48 cm² |
| Test Gases | O₂, N₂, CO₂, air, He (user-supplied gas source) |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×W×H) | 730 × 510 × 350 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 63 kg |
| Brand | HARKE |
|---|---|
| Model | HK-C2 |
| Application | Vacuum-Method Gas Permeability Tester for Films and Flexible Packaging Materials |
| Origin | Beijing, China |
| Manufacturer | HARKE (Domestic Producer) |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, NH₃, C₃H₈, C₄H₁₀ (hazardous gases require pre-order specification) |
| Measurement Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temp. Stability | ±0.1 °C |
| Specimen Thickness | ≤5 mm (customizable) |
| Specimen Size | ≥150 mm × 94 mm or circular |
| Effective Test Area | 48 cm² |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions | 330 mm (L) × 600 mm (D) × 330 mm (H) |
| Power | AC 220 V, 50 Hz |
| Weight | 28 kg |
| Sample Capacity | 1 specimen per test chamber |
| Multi-chamber Option | Up to 3 independent test chambers (configurable) |
| Clamping Method | Pneumatic |
| Test Modes | Proportional, Fuzzy Logic, and Time-Based Endpoint Detection |
| Expandable Range | Optional high-permeability modules available |
| Hazardous Gas Compatibility | Available with custom safety interlocks and gas-handling modules (subject to engineering review) |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HK-CV2 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HK-CV3 |
| Pricing | Available Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HK-G1 |
| Price | Upon Request |
| Measurement Principle | Vacuum-based differential pressure method (ASTM D1434 compliant) |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-order specification) |
| Standard Test Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temperature Accuracy | ±0.1 °C |
| Sample Thickness | ≤5 mm (customizable) |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Sample Quantity | 1 specimen per test |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Weight | 28 kg |
| Power | AC 220 V, 50 Hz |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HK-G106 |
| Test Principle | Vacuum Method (Manometric) |
| Measurement Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temperature Accuracy | ±0.1 °C |
| Sample Thickness | ≤5 mm (customizable) |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Gases | O₂, N₂, CO₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-order specification) |
| Operating Pressure Range | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Model | HK-G3 |
| Measurement Range | 10–10,000 s/100 mL·in² at 1.22 kPa |
| Pressure Control Range | 0–20 kPa (customizable) |
| Sample Thickness Limit | ≤5 mm |
| Test Area | 0.025 in² |
| Vacuum Resolution | 0.1 Pa |
| Sample Count per Run | 1 |
| Gas Compatibility | O₂, N₂, CO₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-consultation) |
| Interface | Ø8 mm tubing |
| Dimensions (L×W×H) | 730 × 510 × 350 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 68 kg |
| Control System | Embedded 32-bit ARM processor with TFT color touchscreen |
| Automation Level | Fully automatic sample clamping, pressure regulation, vacuum evacuation, and data acquisition |
| Output Parameters | Gas Transmission Rate (GTR), Permeability Coefficient (P), Diffusion Coefficient (D), Solubility Coefficient (S) |