| Brand | Beijing Liuyi (LY) |
|---|---|
| Origin | Beijing, China |
| Model | DYY-4C |
| Output Voltage Range | 5–1600 V (2 V resolution) |
| Output Current Range | 2–100 mA (1 mA resolution) |
| Max Power Output | 160 W |
| Dimensions (W × D × H) | 315 × 290 × 128 mm |
| Weight | 5 kg |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | EPS |
| Application | Dedicated Power Supply for Electrophoresis Systems |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Compliance | CE, UL 61010-1, IEC 61010-2-040 |
| Safety Features | Overload Protection, Short-Circuit Protection, Auto-Restart After Power Interruption |
| Power Range | EPS 301 (1–80 W) |
| Voltage Range | EPS 301 (5–300 V DC) |
| Current Range | EPS 301 (10–400 mA) |
| Time Programming | EPS 301 (00.01–23.59 h or OFF) |
| EPS 3501XL (00 | 01–500 h) |
| Resolution | Voltage (1 V), Current (EPS 301: 1 mA |
| EPS 3501XL | 1 µA to 1 mA depending on range), Time (1 min) |
| Accuracy | Voltage (±4% ±2 V for EPS 301 |
| Timer Accuracy | ±0.1% ±1 min (EPS 301) |
| ±0.1% ±1 min (≤99 | 59 h) / ±0.1% ±10 min (100–500 h) for EPS 3501XL |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | STC-ZINCAIR-W |
| Price Range | USD 700 – 1,400 (FOB) |
| Compatible Instrumentation | X-ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR), Synchrotron Beamlines |
| Construction Material | 316 Stainless Steel Body |
| Sealing System | PTFE Cylinder + Fluoroelastomer (FKM) O-Rings |
| Optical Window | Fused Silica (Quartz), Ø10 mm × 1 mm Thickness |
| Optional Window Materials | BaF₂, Al₂O₃, CaF₂, Sapphire |
| Maximum Electrode Diameter | Ø16 mm |
| Maximum Operating Temperature | 200 °C |
| Gas Interface | Dual 1/16″ Swagelok®-Compatible Stainless Steel Needle Valves + 1/16″ SS Tubing |
| Overall Dimensions | Ø80 mm × 62 mm |
| Certification | CE Marked |
| Warranty | 12 Months Full Coverage, Lifetime Technical Support |
| Compliance | Designed for ISO/IEC 17025-aligned laboratories |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Origin | Beijing, China |
| Model | DYY-11 |
| Output Channels | 4 independent parallel outputs |
| Voltage Range | 4–1000 V (1 V resolution) |
| Current Range | 4–500 mA (1 mA resolution) |
| Power Range | 4–300 W (1 W resolution) |
| Dimensions (W×D×H) | 303 × 364 × 137 mm |
| Weight | 7.5 kg |
| Display | Large LCD with real-time parameter monitoring |
| Control Modes | Constant Voltage / Constant Current / Constant Power |
| Programming | 10 stored protocols, up to 9 steps per protocol |
| Protection Features | Over-voltage, over-current, over-load, load variation, and no-load detection with automatic shutdown |
| Memory | Non-volatile program storage |
| Cooling | Integrated forced-air cooling system |
| Compliance | Designed for laboratory electrophoresis applications per IEC 61010-1 safety standards |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Origin | Beijing, China |
| Model | DYY-15D |
| Output Channels | 4 parallel independent outputs |
| Voltage Range | 20–5000 V (2 V resolution) |
| Current Range | 3–300 mA (1 mA resolution) |
| Power Range | 5–300 W (1 W resolution) |
| Display | Large LCD showing real-time voltage, current, power, and timer |
| Programming | 10 stored protocols, each with up to 9 programmable steps |
| Operating Modes | Constant Voltage, Constant Current, Constant Power, Timer Mode, Volt-Hour Mode, Stepwise Program Mode |
| Safety Features | Overload protection, short-circuit auto-shutdown, over-temperature monitoring, low-current maintenance mode, power-fail recovery |
| Dimensions (W×D×H) | 278 × 349 × 110 mm |
| Weight | 4.0 kg |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Model | DYY-2C |
| Output Modes | Constant Voltage & Constant Current |
| Voltage Range | 0–600 V (1 V resolution) |
| Current Range | 0–100 mA (1 mA resolution) |
| Max Power | 60 W |
| Dimensions (W × D × H) | 235 × 295 × 95 mm |
| Weight | 2.5 kg |
| Display | Digital LCD showing real-time V, I, and timer |
| Protection | Overvoltage, overcurrent, overload, variable-load, and no-load detection with auto-shutdown |
| Cooling | Passive convection |
| Output | 4 parallel DC output terminals |
| Control | Microprocessor-based digital regulation with memory recall |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Model | DYY-6D |
| Output Channels | 4 independent parallel outputs |
| Voltage Range | 6–600 V (1 V resolution) |
| Current Range | 4–600 mA (1 mA resolution) |
| Power Range | 1–300 W (1 W resolution) |
| Display | Large LCD showing real-time V, I, P, and timer |
| Memory | 10 user-programmable 3-step protocols |
| Control | Microprocessor-based with continuous parameter adjustment |
| Safety | Overload, short-circuit, over-temperature, and automatic shutdown protection |
| Dimensions (W×D×H) | 246 × 360 × 80 mm |
| Weight | 3.2 kg |
| Compliance | Designed for GLP-compliant electrophoresis workflows in molecular biology labs |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Origin | Beijing, China |
| Model No. | 112-0730 |
| Output Voltage Range | 2–300 V (1 V resolution) |
| Output Current Range | 5–2000 mA (2 mA resolution) |
| Max. Power Output | 300 W |
| Dimensions (W × D × H) | 315 × 290 × 128 mm |
| Weight | 5 kg |
| Output Channels | 4 independent parallel outputs |
| Protection Features | Over-voltage, over-current, over-load, and load-mismatch detection |
| Control System | Microprocessor-based with real-time parameter adjustment |
| Display | LCD showing simultaneous voltage, current, and timer values |
| Memory Function | Parameter storage for repeat protocols |
| Power Architecture | High-efficiency switching-mode power supply |
| Brand | LY (Beijing Liuyi) |
|---|---|
| Origin | Beijing, China |
| Model | DYY-8C |
| Output Modes | Constant Voltage & Constant Current |
| Voltage Range | 5–600 V (1 V resolution) |
| Current Range | 2–200 mA (1 mA resolution) |
| Max Power | 120 W |
| Output Channels | 4 parallel DC outputs |
| Dimensions (W×D×H) | 235 × 295 × 95 mm |
| Weight | 2.5 kg |
| Display | LCD showing real-time voltage, current, and timer |
| Protection Features | Over-voltage, over-current, over-load, load variation, and no-load detection |
| Control System | Microprocessor-based with memory recall function |
| Cooling | Integrated forced-air cooling system |
| Compliance | Designed for laboratory electrophoresis applications per standard molecular biology protocols (e.g., SDS-PAGE, agarose gel electrophoresis) |
| Brand | Piezodrive |
|---|---|
| Origin | Australia |
| Model | PDUS210 |
| Output Power | 210 W |
| Output Voltage Range | 17–282 Vrms |
| Output Current Range | 0.7–11 Arms |
| Load Impedance Range | 1.5–400 Ω (optimized) |
| Frequency Range | 6–500 kHz |
| Waveform | Pure Sine |
| Control Interfaces | USB, RS485, Digital I/O (4-channel), Front Panel, Footswitch |
| Compliance | CE, RoHS |
| Software | Included PC-based control suite with real-time impedance analysis and resonance tracking |
| Brand | Semicircle-Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HVP10P10BN-DS |
| Output Voltage | 0–10 kV DC |
| Output Current | 0–2 mA |
| Max. Output Power | 10 W |
| Filament Supply | 0–4 V DC / 0–2 A (adjustable current limit) |
| Input | 24 V DC ±10%, max. 2.0 A |
| Voltage Regulation | ≤0.01% (load) |
| Current Regulation | ≤0.01% (load) |
| Stability (8 h) | ≤0.05% after 30-min warm-up |
| Ripple | ≤0.3% pk-pk of rated output voltage |
| Monitoring Output | 0–10 V DC proportional to 0–Vmax & 0–Imax (Zout = 1 kΩ, accuracy ±1%) |
| Temp. Coefficient | 0.01% / °C |
| Inrush Surge Peak | ≤1 A @ 25°C |
| Operating Temp. | 0–50°C |
| Storage Temp. | −40 to +85°C |
| Weight | 0.4 kg |
| Dimensions | See mechanical drawing |
| Brand | SRS (Stanford Research Systems) |
|---|---|
| Origin | USA |
| Model | CS580 |
| Compliance | Imported Instrument |
| Output Compliance Voltage | ±50 V |
| Current Range | 100 fA to 100 mA (source/sink) |
| Transconductance Gain | 1 nA/V to 50 mA/V (selectable ranges) |
| AC Bandwidth | Up to 150 kHz |
| DC Bias Superposition | Yes |
| Noise Floor | Ultra-low (sub-pA/√Hz typical) |
| Leakage Current | <10 fA |
| Thermal Drift | <10 pA/°C |
| Interfaces | RS-232, Optical Fiber (isolated remote control) |
| Application Context | X-ray instrumentation, cryogenic transport measurements, quantum device characterization |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Invitrogen PowerEase Touch Touchscreen Electrophoresis Power Supply |
| Pricing | Available Upon Request |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | AMW |
| Output Voltage | ±20 kV DC or AC peak |
| Output Power | 400 W |
| Output Current | ±20 mA DC or AC peak |
| Input Range | ±10 V DC or AC peak |
| Gain | 2000 V/V (DC) |
| Gain Accuracy | < ±0.1% of full scale |
| Output Noise | < 1.5 Vrms |
| Slew Rate | > 450 V/µs (10–90%) |
| Large-Signal Bandwidth | DC to > 7.5 kHz (–3 dB), DC to > 3.75 kHz (1% THD) |
| Small-Signal Bandwidth | DC to > 20 kHz (–3 dB) |
| Stability | < 50 ppm/hr (non-cumulative) |
| Tempco | < 25 ppm/°C |
| Operating Temp | 0–40 °C |
| Humidity | ≤85% RH, non-condensing |
| Altitude | ≤2000 m |
| Dimensions | 264 × 483 × 635 mm (H×W×D) |
| Weight | 25 kg |
| Input Impedance | 25 kΩ |
| Output Impedance | 47 Ω |
| Display Resolution | Voltage: 2000:1 (0.1% FS accuracy) |
| Current | 1 V / 6 mA (0.5% FS accuracy) |
| Brand | Wiseman |
|---|---|
| Model | AMX |
| Output Voltage | ±30 kV DC or AC peak |
| Output Current | ±20 mA DC or AC peak |
| Power Rating | 600 W |
| Input Voltage | 220 V AC ±10% |
| Input Current | 10 A |
| Gain | 3000 V/V (DC) |
| Gain Accuracy | < 0.1% of full scale |
| Output Noise | < 1.5 V RMS |
| Slew Rate | > 550 V/µs (10%–90%) |
| Large-Signal Bandwidth | DC to > 2.5 kHz |
| Small-Signal Bandwidth (−3 dB, 1% THD) | DC to > 30 Hz |
| Stability | < 50 ppm/hr (non-cumulative) |
| Temperature Coefficient | < 25 ppm/°C |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Altitude | ≤2000 m |
| Dimensions | 1040 mm H × 430 mm W × 870 mm D |
| Weight | 70 kg |
| Input Impedance | 25 kΩ |
| Output Impedance | 47 Ω |
| Voltage Display Scale | 3000:1 |
| Current Display Scale | 1 V / 6 mA |
| Voltage Display Accuracy | < 0.1% FS |
| Voltage Display Offset | < ±5 mV |
| Voltage Display Noise | < 20 mV RMS |
| Current Display Accuracy | < 0.5% FS |
| Current Display Offset | < ±10 mV |
| Current Display Noise | < 30 mV RMS |
| Quadrant Operation | Four-quadrant active output (source/sink) |
| Load Compatibility | Resistive, capacitive, and reactive loads |
| Isolation | Fully solid-state high-voltage insulation |
| Application Focus | Mass spectrometry biasing, electro-optic modulation, ferroelectric polarization, plasma actuation, ion beam steering |
| Brand | Wiseman |
|---|---|
| Model | AMY |
| Output Voltage | ±40 kV (DC or AC peak) |
| Output Current | ±15 mA (DC or AC peak) |
| Power Rating | 600 W |
| Input Voltage Range | ±10 V DC or AC peak |
| Voltage Gain | 4000 V/V (DC) |
| Gain Accuracy | < 0.1% of full scale |
| Output Noise | < 5 V RMS |
| Slew Rate | > 350 V/µs (10%–90%) |
| Small-Signal Bandwidth (−3 dB, 1% THD) | DC to > 20 Hz |
| Large-Signal Bandwidth | DC to > 1.4 kHz |
| Stability | < 50 ppm/hr (non-cumulative) |
| Temperature Coefficient | < 25 ppm/°C |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Altitude | ≤2000 m |
| Dimensions (H×W×D) | 1040 × 430 × 870 mm |
| Weight | 90 kg |
| Input Impedance | 25 kΩ |
| Output Impedance | 47 Ω |
| Display Resolution | 4000:1 (voltage), 1 V/5 mA (current) |
| Protection | Active short-circuit protection, four-quadrant active output, thermal and overcurrent monitoring |
| Brand | Wiseman |
|---|---|
| Model | AMZ |
| Output Voltage | ±50 kV DC or AC peak |
| Output Power | 600 W |
| Output Current | ±12 mA DC or AC peak |
| Input Signal Range | ±10 V DC or AC peak |
| Voltage Gain | 5000 V/V (DC) |
| Gain Accuracy | < ±0.1% of full scale |
| Output Noise | < 10 V RMS |
| Slew Rate | > 350 V/µs (10–90%) |
| Large-Signal Bandwidth | DC to > 1.4 kHz |
| Small-Signal Bandwidth (−3 dB, 1% THD) | DC to > 20 Hz |
| Stability | < 50 ppm/hr (non-cumulative) |
| Temperature Coefficient | < 25 ppm/°C |
| Operating Temperature | 0–40 °C |
| Humidity | ≤75% RH (non-condensing) |
| Altitude | Up to 2000 m |
| Dimensions | 1473.5 × 628.7 × 948.4 mm |
| Weight | 125–136 kg |
| Input Impedance | 25 kΩ |
| Output Impedance | 47 Ω |
| Voltage Display Ratio | 5000:1 |
| Current Display Ratio | 0.5 V/mA |
| Short-Circuit Protection | Active, programmable |
| Quadrant Operation | Four-quadrant active output (source/sink) |
| Load Compatibility | Resistive, capacitive, and reactive loads |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | B |
| Output Voltage Range | 0.3–25 kV (selectable in standard steps) |
| Output Power | 6 W |
| Input Voltage | 2–24 VDC |
| Input Current | ≤360 mA |
| Polarity | Reversible Bipolar (±) |
| Isolation Voltage | ±7 kV DC (≤6 kV models) |
| Load Regulation | 12% (for 50% load change) |
| Protection | Arc detection & transient short-circuit protection |
| Operating Temperature | −10 °C to +60 °C |
| Humidity | 30–85% RH (non-condensing) |
| Compliance | Designed for OEM integration in analytical instrumentation requiring IEC 61010-1 safety isolation and EMC robustness |
| Primary Applications | Mass spectrometry ion sources, PMTs, MCPs, electron/ion beam focusing, electrostatic chucks, piezoelectric actuators, avalanche photodiodes |
| Brand | Wiseman |
|---|---|
| Output Voltage Range | 0.1–10 kV (selectable) |
| Output Power | 0.5–1.25 W |
| Input Voltage Options | +5 VDC ±2% (standard), +12/+15/+24 VDC (optional) |
| Input Current | 550 mA |
| Isolation Voltage | ≤ ±500 VDC |
| Voltage Accuracy | ±10% at rated load |
| Operating Temperature | +25 °C to +75 °C |
| Storage Temperature | −55 °C to +105 °C |
| Humidity | ≤80% RH, non-condensing |
| Dimensions | 11 mm × 11 mm × 11 mm (≤2 kV) |
| Weight | 5 g (≤2 kV) |
| Polarity | Bipolar (simultaneous or reversible ± output) |
| Mounting | Floating operation compatible |
| Compliance | Designed for OEM integration in analytical and scientific instrumentation |
| Brand | Wiseman |
|---|---|
| Model | BP |
| Output Voltage | 0.5 kV (100–500 V DC selectable) |
| Output Power | 2.5 W |
| Input Voltage Range | +2 to +24 V DC |
| Isolation Voltage | 500 V DC (input-to-output) |
| Ripple | ≤0.5% p-p |
| Temperature Coefficient | 25 ppm/°C |
| Load Regulation | ≤5% over 20–100% load |
| Operating Temperature | −10 °C to +50 °C |
| Storage Temperature | −20 °C to +60 °C |
| Dimensions | 60 mm × 40 mm × 17 mm |
| Weight | 50 g |
| Compliance | Designed for OEM integration in analytical instrumentation requiring stable, isolated HV bias |
| Brand | Wiseman |
|---|---|
| Model | DED |
| Output Voltage Range | 0.5–50 kV (adjustable) |
| Output Current Range | 0–50 mA |
| Maximum Output Power | 100 W |
| Input | AC 86–256 V ±10%, 3 A |
| Ripple | ≤0.1% peak-to-peak of rated output voltage |
| Stability | <25 ppm/h (after 30 min warm-up) |
| Temperature Coefficient | ≤25 ppm/°C |
| Voltage & Current Regulation | Local (multi-turn potentiometer) or Remote (0–10 V analog, USB/RS-232/RS-422 digital) |
| Protection Features | Overvoltage, Short-Circuit, Arc Detection, Interlock Safety |
| Dimensions | 310 × 130 × 185 mm |
| Weight | 2.5–6.2 kg |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Wiseman |
|---|---|
| Model | DEF |
| Output Voltage Range | 1–70 kV DC |
| Maximum Continuous Output Power | 350 W |
| Input Voltage | 86–265 VAC, 47–63 Hz |
| Power Factor | ≥0.99 (with active PFC) |
| Ripple | ≤0.1% RMS (≤20 kHz) |
| Voltage Stability | <25 ppm/8 h (after 2-h warm-up) |
| Temperature Coefficient | ≤25 ppm/°C |
| Output Polarity | Selectable Positive or Negative HV |
| Control Interfaces | Local front-panel potentiometer, Analog 0–10 V remote control, RS-232, RS-485, Ethernet (optional) |
| Protection Features | Overvoltage, Overcurrent, Arc Detection, Short-Circuit, Interlock |
| Dimensions (W×H×D) | 80 × 254 × 280 mm |
| Weight | 5.5 kg |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40–85 °C |
| Compliance | Designed for laboratory and industrial HV applications requiring IEC 61010-1 safety principles and electromagnetic compatibility per EN 61326-1 |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | DF |
| Output Voltage Range | 1–70 kV DC |
| Output Power | 4 kW |
| Ripple | 0.03% p-p |
| Stability | <0.02% per 8 hours (after 1-hr warm-up) |
| Temperature Coefficient | 25 ppm/°C |
| Input | AC 220 V ±10% (3-phase optional) |
| Interfaces | Standard Ethernet & RS-232 |
| Protection | Overvoltage, Overcurrent, Short-Circuit, Arc Detection, Overtemperature, Safety Interlock |
| Compliance | CE certified |
| Remote Control | 0–10 V analog voltage/current setpoint & monitor signals |
| Dimensions (4 kW unit, ≤60 kV) | 132 mm H × 483 mm W × 610 mm D (3U 19″ rack) |
| Application | Mass spectrometry systems, electron/ion beam sources, X-ray generators, high-energy physics instrumentation, semiconductor processing equipment |
| Brand | Wiseman |
|---|---|
| Origin | Shaanxi, China |
| Model | DH |
| Output Voltage | 0–150 kV (200 kV standard option, 300 kV customizable) |
| Output Power | 2 kW |
| Input | AC 220 V ±10%, 15 A |
| Ripple | 0.1% P-P + 1 Vrms |
| Stability | <100 ppm/h after 30-min warm-up |
| Temperature Coefficient | 100 ppm/°C |
| Voltage & Current Control | Local (multi-turn potentiometers) and Remote (0–10 V analog interface) |
| Communication Interfaces | Standard Ethernet + RS-232, optional RS-485 |
| Protection Features | Overvoltage, overcurrent, short-circuit, arc detection, overtemperature, safety interlock |
| Compliance | CE certified |
| Dimensions (150 kV unit) | 4U (176 mm H × 483 mm W × 559 mm D) |
| Display | 4-digit LED panel meter (±1% accuracy at rated output) |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40–85 °C |
| Brand | Wiseman |
|---|---|
| Output Voltage Range | 1–130 kV (selectable) |
| Output Power | Up to 1.2 kW |
| Ripple | 0.1% P-P |
| Voltage Stability | <100 ppm/8 h (after 30-min warm-up) |
| Temperature Coefficient | ≤25 ppm/°C |
| Control Interface | RS-232, Ethernet (standard), RS-485 (optional) |
| Safety Features | Overvoltage, Overcurrent, Arc Detection, Short-Circuit, Overtemperature, Interlock |
| Compliance | CE Certified |
| Input | AC 220 V ±10%, 10 A (AC 110 V optional) |
| Operating Temperature | 0–50 °C |
| Dimensions | 1U or 2U (44 mm or 88 mm H) × 483 mm W × 483 mm / 610 mm D |
| Application-Specific Design | Optimized for electrophoresis systems and high-voltage scientific instrumentation |
| Brand | Wiseman |
|---|---|
| Model | DNA30kV/15W |
| Output Voltage | 30 kV (adjustable from 600 V to 30 kV) |
| Output Current | 0.5 mA |
| Output Power | 15 W |
| Ripple & Noise | <0.01% p-p |
| Stability | ±0.02% over 8 hours |
| Temperature Coefficient | 25 ppm/°C |
| Input | DC 24 V |
| Communication Interface | Optional RS-232 / RS-485 |
| Polarity | Selectable Positive or Negative |
| Protection | Arc detection, short-circuit protection |
| Dimensions (H×W×D) | 43.0 × 100.0 × 205.0 mm |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40–+85 °C |
| Humidity | 20–85% RH (non-condensing) |
| Compliance | Designed for OEM integration in analytical instrumentation requiring IEC 61010-1 safety and EMC robustness |
| Brand | Wiseman |
|---|---|
| Model | DR |
| Output Polarity | Reversible |
| Max Output Voltage | 300 kV |
| Max Output Power | 6 kW |
| Ripple | 0.1% P-P + 1 Vrms |
| Stability | <100 ppm/h (after 30 min warm-up) |
| Temperature Coefficient | 25 ppm/°C |
| Control Interfaces | Standard Ethernet & RS-232, Optional RS-485 |
| Protection | Overvoltage, Overcurrent, Short-Circuit, Arc Detection, Overtemperature, Safety Interlock |
| Compliance | CE Certified |
| Dimensions (1–120 kV) | 266 mm H × 483 mm W × 533 mm D (6U 19″ rack) |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40–85 °C |
| Display | 4-digit LED panel meter (±1% accuracy at rated output) |
| Remote Control | 0–10 V analog for voltage/current setpoint and monitoring |
| Optional Feature | Constant Power Control (CPC) |
| Brand | Wiseman |
|---|---|
| Model | EM30kV/9W |
| Output Voltage Range (Accelerator) | –30 kV to +30 V |
| Output Current | 200 µA |
| Load Regulation | < ±100 ppm (0–100% load) |
| Line Regulation | < ±100 ppm (±10% input variation) |
| Ripple | ≤10 ppm |
| Temperature Coefficient | 100 ppm/°C |
| Short-Term Stability | 10 ppm / 3 min (after 1-hr warm-up) |
| BIAS Output | 0 to –2000 V, 0–150 µA |
| FIL+ Output | 0–3 A @ 1 Ω |
| SCI Output | 0–10 kV, 0–250 µA |
| COL Output | 0–400 V, 0–500 µA |
| PMT/MCP Output | 0–1500 V, 0–1000 µA |
| Operating Temperature | 0–40 °C |
| Cooling | Forced-air (front intake / rear exhaust) |
| Weight | 5 kg |
| Brand | Wiseman |
|---|---|
| Output Voltage | 7.5 V |
| Output Power | 37.5 W |
| Input Voltage | 24 V ±10 V |
| Input Current (Full Load) | 3 A |
| Output Voltage Stability | ≤0.1 %/h after warm-up |
| Ripple & Noise | ≤200 mVpp (typ.) |
| Voltage Regulation (Line) | ≤0.01 % (typ.) |
| Load Regulation | ≤0.01 % (typ.) |
| Temperature Coefficient | <0.1 %/°C |
| Isolation Voltage | 5–30 kV (selectable) |
| Control Interface | 0–10 V analog input (5 kΩ input impedance) |
| Rise Time (0–99%) | 100 ms |
| Operating Temperature | 10–50 °C |
| Storage Temperature | −35–+85 °C |
| Humidity | ≤80 % RH (non-condensing) |
| Dimensions | 205 × 100 × 43 mm |
| Weight | 1.5 kg |
| Protection Features | Reverse polarity, overvoltage, short-circuit, arc detection, continuous overload |
| Compliance | Designed for OEM integration in mass spectrometry systems |
| Brand | Wiseman |
|---|---|
| Model | MA |
| Output Voltage | 0–10 kV (customizable) |
| Output Power | Up to 6 W |
| Output Current | 1–20 mA (model-dependent) |
| Input Voltage | DC 24 V ±1 V (optional: ±5 V, ±12 V, ±15 V) |
| Voltage Stability | ±0.001% |
| Ripple | ≤0.001% RMS |
| Temperature Coefficient | ±0.001%/°C |
| Line & Load Regulation | ±0.001% |
| Protection | Short-Circuit & Arc-Discharge |
| Operating Temp. | -10°C to +50°C (S-grade), -25°C to +65°C (G-grade), -40°C to +95°C (T-grade) |
| Dimensions | Ø70 × W57 × H22 mm |
| Certifications | ISO 9001, CE (per applicable directives), RoHS compliant |
| Application | Mass Spectrometry, Electron Microscopy, PMT Biasing, Ion/Electron Beam Acceleration, Electrostatic Applications |