Empowering Scientific Discovery

Jiangsu Sheng'ao Hua Environmental Protection Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable
Measurement PrinciplePotassium Dichromate Digestion + Spectrophotometry
Wavelength Range400–750 nm
COD Range5–12,000 mg/L (multi-range)
Accuracy≤ ±5%
Repeatability≤ ±5%
LOD (COD)0.1 mg/L
Digestion & Analysis Time10–30 min
Batch Capacity12 samples per run
Data Storage5 million records
Calibration Curves119 preloaded
Chloride Interference ToleranceCl⁻ < 1200 mg/L (standard), up to 4000 mg/L (with correction)
Digestion Temp165 °C or 123 °C ±0.5 °C
Power SupplyAC 220 V ±10%, 50 Hz (adapter) / DC 24 V (rechargeable battery)
Dimensions440 × 350 × 190 mm
Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelSH-3000A
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleRapid Digestion Spectrophotometry
Wavelength610 nm ± 1 nm (COD channel)
COD Range5–6000 mg/L (segmented)
Ammonia Nitrogen0.01–100 mg/L
Total Phosphorus0.001–16 mg/L
Total Nitrogen0.01–100 mg/L
Turbidity0–200 NTU
Accuracy≤ ±5%
Repeatability≤ ±5%
LOD (COD)0.1 mg/L
Measurement Time25–30 min (including digestion)
Batch Capacity24 or 30 samples
Digestion Temp165 °C / 123 °C ± 0.5 °C
Digestion Time10 / 30 min
Chloride Tolerance≤ 1200 mg/L (standard), up to 4000 mg/L (with chloride compensation)
Photometric Stability≤ 0.001 A / 10 min
Dimensions435 × 330 × 170 mm
Weight3 kg
Power SupplyAC 220 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelSH-200
Instrument TypeLaboratory-Grade
Measurement PrincipleRapid Digestion Method
Wavelength610 ± 1 nm
Measurement Range5–6000 mg/L
Accuracy≤ ±5%
Repeatability≤ ±5%
Limit of Detection5 mg/L
Analysis Time20 minutes per batch
Sample Throughput16 samples per run
Display5-inch IPS capacitive touchscreen
Wavelength Accuracy±1 nm
Data Storage Capacity>100,000 measurement records (expandable via TF card up to 5 million entries)
Power SupplyAC 220 V, 50 Hz
Dimensions270 × 190 × 130 mm
Net Weight1.5 kg
Light SourceLong-life cold LED (≥100,000 h lifetime)
Optical DesignRear-mounted monochromator with narrow-band interference filter
Optional OutputWireless thermal printer interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelSH-9007(V11)
Instrument TypePortable
Measurement PrinciplePotassium Dichromate Digestion Method (Portable)
Wavelength Range400–860 nm
COD Range10–100 mg/L and 30–5000 mg/L (dual-range)
Accuracy≤ ±5%
Repeatability≤ ±5%
LOD0.01 mg/L
Analysis Time15 min per batch
Batch Capacity5 samples
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeOEM Producer
Product CategoryDomestic Lab Instrument
ModelSH-2000A
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleRapid Digestion Spectrophotometry
Wavelength Range190–1100 nm ±1 nm
COD Range5–1000 mg/L
Accuracy≤±5%
Repeatability≤±5%
LOD (COD)0.1 mg/L
Analysis Time20–40 min per batch
Batch Capacity24 samples
Temperature Control RangeAmbient to 200 °C
Dual-Zone Digestion Temperatures165 °C / 123 °C ±0.5 °C
Digestion Times10 / 30 min
Chloride Interference ToleranceCl⁻ < 1200 mg/L (standard), < 4000 mg/L (with correction)
Photometric Stability≤±0.005 A / 20 min
Data Storage5 million records
Preloaded Calibration Curves680
Dimensions360 × 280 × 100 mm
Net Weight3 kg
Power SupplyAC 220 V ±10%, 50 Hz
InterfaceUSB
Optional ConnectivityIoT-enabled remote monitoring (PC & mobile)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengAohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Benchtop
Measurement PrincipleRapid Digestion Method (HJ/T 399–2007)
Wavelength420 nm / 610 nm ±1 nm
COD Range50–1000 mg/L
Accuracy±5%
Repeatability±5%
LOD50 mg/L
Analysis Time per Batch10–20 min
Sample Throughput20 samples/batch
Optical Stability≤±0.002 Abs/h
Photometric Repeatability0.2% T
Absorbance Reproducibility±0.003 Abs
Liquid Dispensing Accuracy≤1%
Heating ControlAdaptive PID at 165 °C ±1 °C
CoolingHigh-airflow silent fan
Dimension (Cabinet)830 × 800 × 1780 mm
Dimension (Desktop)830 × 700 × 700 mm
Weight~60 kg
Power SupplyAC 220 V ±10%, 50 Hz
Rated Power~780 W
Operating Environment0–50 °C, 10–90% RH
Positioning Precision (Robotic Arm)0.1 mm
Display8-inch IPS capacitive touchscreen
Light SourceImported cold-light LED (100,000 h lifetime)
Optical PathPost-dispersion design
Data InterfaceIoT-enabled cloud upload (ShengAohua Cloud Data Service)
ComplianceHJ/T 399–2007, HJ 924–2017, GB/T 32208–2015, GB/T 12519–2010
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelSH-8
Instrument TypeLaboratory-Grade Portable Analyzer
Measurement PrincipleDual-Optical-Path Digital Electrode-Based Optical Absorption (Reagent-Free)
Measurement Range0.15–300 mg/L COD
Accuracy≤ ±8%
Repeatability≤ ±5%
Limit of Detection0.01 mg/L
Measurement Time1 minute per sample
Batch Capacity12 / 16 / 25 / 30 / 35 / 56 samples
Display3.1-inch amber-tinted LCD
Sensor DimensionsØ33.7 mm × 176.5 mm (excluding cable)
Housing MaterialsPOM, Nylon, and 316 Stainless Steel
Device Dimensions200 × 100 × 35 mm
Net Weight0.3 kg
Operating Temperature5–45 °C
Max Pressure Rating1 bar
CalibrationSingle-point user calibration
Power SupplyDC 5 V ±5%, <50 mA
BatteryIntegrated rechargeable lithium-ion battery
Data StorageBuilt-in microSD card slot for local data logging and retrieval
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0