Empowering Scientific Discovery

Jiangsu Sheng'ao Hua Environmental Protection Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelSH-10S (V10)
Digestion MethodReflux Digestion
Heating ModuleIntegrated Aluminum Block with Forced-Air Convection
Batch Capacity10 samples
Temperature Range0–168 °C
Temperature Accuracy±1 °C
Digestion Vessel Capacity250 mL
Timer Resolution0.1 s
Power Input3000 W (AC 220 V ±10%, 50 Hz)
Display7-inch HD capacitive touchscreen (Chinese UI)
Cooling ModeDual-mode — selectable air-cooling or water-cooling
AlarmAudible end-of-digestion alert with automatic heating cutoff
Weight32 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelSH-2000
Instrument TypeLaboratory Water Quality Analyzer
Measurable ParametersCOD, Ammonia Nitrogen, Total Phosphorus, Total Nitrogen, Turbidity, Heavy Metals (e.g., Cu, Fe, Zn, Ni, Ag, Mn, Cr, Cr⁶⁺), Color, Suspended Solids, Sulfide, Silicate, Residual Chlorine, Total Chlorine, Formaldehyde, Cyanide, Phosphate, Benzidine, Phenol, Permanganate Index, Nitrate-N (UV & Vis), Nitrite-N, Sulfate, Fluoride, Ozone, Chlorine Dioxide, Hardness, etc.
Wavelength Range190–1100 nm ±1 nm
Wavelength Accuracy±1 nm (auto-calibrated)
Spectral Bandwidth2 nm
Measurement Error≤±5%
Repeatability±5%
Photometric Stability≤±0.005 A/20 min
Digestion Temperatures165 °C / 123 °C ±0.5 °C
Digestion Times10 min / 30 min
Sample Capacity30 samples/batch
Chloride Interference ToleranceCl⁻ < 1200 mg/L (standard)
Power SupplyAC 220 V ±10%, 50 Hz
Dimensions360 × 280 × 100 mm
Net Weight3 kg
InterfaceUSB
Data StorageBuilt-in high-capacity TF card (≥10 years’ logging capacity)
Display7-inch capacitive color touchscreen
Light SourcesIndependently controlled tungsten and deuterium lamps
Preloaded Calibration Curves680 standard curves + user-definable curve library
OutputIntegrated thermal printer
Software CompatibilityLIMS integration via documented communication protocol (ASCII/Modbus RTU over USB)
Regulatory AlignmentDesigned for compliance with ISO 7027 (turbidity), ISO 6060 (COD), ISO 7150-1 (ammonia nitrogen), ISO 11908 (total phosphorus), USP <643>, EPA Methods 410.4, 365.4, 353.2, and GLP/GMP data integrity requirements (audit trail, user access control, electronic signature readiness)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory BOD Analyzer
ModelSH-804S / SH-806S / SH-808 / SH-812
Measurement PrincipleManometric (Pressure-Difference) Method
Measurement Range0–4000 mg/L
Detection Limit0.01 mg/L
Accuracy±8%
Repeatability±3%
Resolution0.1 mg/L
Incubation Temperature20 °C ±1 °C
Data Logging IntervalEvery 2 hours
Storage Capacity10,000 datasets
Power Rating20 W
Dimensions (SH-804S/806S)200 × 300 × 150 mm
Dimensions (SH-808/812)300 × 300 × 150 mm
Net Weight (SH-804S/806S)1.6 kg
Net Weight (SH-808/812)2.5 kg
Sample Throughput4/6 or 8/12 samples per batch
Display5-inch color touchscreen main display + 1.5-inch auxiliary color LCD
Stirring MechanismElectromagnetic stirring
Data OutputReal-time graphing, auto-printing, wireless data aggregation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
ModelSH-16 (Dual-Zone)
Digestion MethodRapid Digestion
Heating ModuleDual Independent Heating Blocks
Batch Capacity16 tubes (8 × 2 dual-zone configuration)
Temperature RangeAmbient to 185 °C
Temperature Accuracy±0.5 °C
Timer Accuracy±0.1 s
Rated Power400 W
Input VoltageAC 220 V ±20%
Net Weight2.7 kg
Housing MaterialImported High-Transparency PP Engineering Plastic
Display5-inch IPS HD Touchscreen
Preloaded Temperature Profiles7 Standard + 11 User-Definable
Heating RateReaches Setpoint within 10 min
Protection FeaturesOverpressure & Surge Protection, Magnetic Lid Lock, Airflow-Guided Thermal Management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengAohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop Laboratory Analyzer
Detection PrinciplePhotometry (Visible Light Absorption at Specific Wavelength)
Target AnalyteNickel (Ni²⁺)
Measurement Range0–5 mg/L
Resolution0.01 mg/L
Accuracy±8% of Full Scale
Analysis Time20–30 minutes per sample
Light SourceCold LED with Narrow-Band Interference Filter (Lifetime ≥100,000 hours)
Optical Stability≤±0.005 A / 20 min
Sample CellStandard 10-mm Cuvette
Data Storage CapacityUp to 5,000,000 records
InterfaceUSB 2.0 (Host/Device mode)
Printer SupportIntegrated thermal printer
Power SupplyAC 220 V ±10%, 50 Hz
Power Consumption15 W
Dimensions (W×D×H)360 × 280 × 150 mm
Net Weight2.5 kg
Operating Humidity<85% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelSH-90
Detection MethodUV Spectrophotometric Method (Alkaline Potassium Persulfate Digestion)
Measurement Range0.01–100 mg/L (segmented)
Accuracy≤ ±5%
Detection Limit0.01 mg/L
Resolution0.01 mg/L
Wavelength Range190–1100 nm
Wavelength Repeatability≤ 0.2 nm
Data Storage Capacity5 million records
Digestion Temperature123 °C
Digestion Time30 min
Total Assay Time50 min
Sample Throughput12 / 16 / 24 / 30 samples per batch (configurable)
Dimensions485 × 438 × 190 mm
Power SupplyAC 220 V ±10%, 50 Hz
Operating Temperature−5 to 45 °C
Control Interface7-inch HD capacitive touchscreen
Pre-installed Calibration Curves100 (5 factory-standard, 95 user-editable)
ConnectivityUSB port for PC-based data management (optional), thermal printer interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Water Quality Analyzer
Detection PrincipleSpectrophotometry
Measurable ParametersCOD, Ammonia-N, Total Phosphorus, Total Nitrogen, and Expandable to SiO₂, NO₂⁻, PO₄³⁻, BrO₃⁻, Zn²⁺, Formaldehyde, Phenols, NO₃⁻-N, Cu²⁺, Fe²⁺/Fe³⁺, Cr⁶⁺, Total Cr
COD Range5–1000 mg/L
NH₃-N Range0.025–100 mg/L
Total P Range0.01–0.5 mg/L
Total N Range0.05–5 mg/L
Repeatability≤3%
Optical Stability±0.003 Abs/10 min
Absorbance Range0.000–3.000 Abs
Minimum Resolution0.0001 Abs
Temperature Control RangeAmbient–180 °C
Temperature Accuracy±1 °C
Calibration Curves100 stored
Data Storage Capacity100,000 records
Sample Throughput38 samples/batch
Dimensions900 × 700 × 500 mm
Net Weight70 kg
Power SupplyAC 220 V, 50 Hz, 200 W
Operating Environment5–40 °C, ≤85% RH (non-condensing)
Display12.3-inch true-color touchscreen
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengAohua
OriginJiangsu, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelSH-50L
Instrument TypePortable
Measurement PrincipleDPD Spectrophotometry
Measured ParametersResidual Chlorine, Total Chlorine
Range0–3 mg/L
Accuracy≤ ±5%
Repeatability≤ ±5%
Resolution0.001 mg/L
Detection Limit0.001 mg/L
Optical Stability≤ ±0.005 A/20 min
Power SupplyRechargeable Lithium-ion Battery (7-day field operation) + AC/DC Adapter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelSH-21B(V11)
Instrument TypePortable
Measurement PrincipleInfrared Spectrophotometry (Fourier-transform-free dispersive IR)
Measurement Range0–120 mg/L (for C₂Cl₄ extract, 4 cm cell)
Detection Limit0.002 mg/L (in water)
Upper Quantitation Limit640,000 mg/L (in water)
AccuracyRSD < 0.8% (for standard oil reference at 20–80 mg/L)
Resolution0.1 mg/L
Scan Time~30 s (full spectral scan, 3400–2400 cm⁻¹)
Wavenumber Accuracy±1 cm⁻¹
Wavenumber Repeatability±1 cm⁻¹
Absorbance Range0.0000–3.0000 AU (100–1% T)
Baseline DriftZero drift (mechanical chopper stabilization)
Display10.1″ Windows 10 tablet PC (backward-compatible with Win7/Win8)
Battery LifeUp to 8 h
Weight12 kg (main unit)
Dimensions470 × 360 × 230 mm (L×W×H)
Enclosure RatingIP65
Compatible SolventTetrachloroethylene (C₂Cl₄)
Data StorageLocal spectral files, measurement parameters, and results exportable to PC
Power SupplyIntegrated portable rechargeable power module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
ModelSH-24(V10)
Digestion MethodRapid Digestion
Heating ModuleDual Independent Heating Blocks
Batch Capacity24 Samples
Temperature Range0–168 °C
Temperature Accuracy±0.5 °C
Digestion Vial Capacity12 mL
Timing Resolution0.1 s
Display7-inch High-Resolution Touchscreen
Built-in Curves30 Predefined (including 13 Standard + User-Editable)
Power SupplyAC 220 V ±10%, 50 Hz
Rated Power<600 W
Dimensions380 × 250 × 165 mm
Safety FeaturesOvertemperature Cutoff (200 °C), Transparent Acid-Resistant Shield, Dynamic Load-Adaptive Power Control
Cooling PrincipleOptimized Air Convection Architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelSH-9007B
Instrument TypePortable/Handheld Water Quality Analyzer
Measurable ParametersCOD (High/Low Range), Ammonia Nitrogen, Total Phosphorus, Total Nitrogen, Heavy Metals (Cr⁶⁺, Total Cr, Ni, Cu, Fe, etc.), Residual Chlorine, Turbidity, Color, Sulfate, Nitrate Nitrogen, Chloride, pH, Dissolved Oxygen (DO), Conductivity, ORP, Temperature, Chlorophyll-a, Phycocyanin, Turbidity (Electrochemical), COD (Electrochemical), Ammonia (NH₃), and more
Display5-inch IPS Touchscreen (Host), 3.2-inch LCD (Digestion Unit)
Optical Method Wavelength Range400–750 nm
Photometric Accuracy≤ ±5%
Repeatability≤ ±5%
Digestion Temp ControlRoom Temp to 185 °C
Standard Programs165 °C ±0.5 °C (10 min), 123 °C ±0.5 °C (30 min)
Sample Throughput5–6 samples/batch
Memory Capacity32 GB microSD (≥100,000 data records)
Power SupplyAC/DC adapter & 12 V vehicle power compatible
BatteryHigh-capacity Li-ion (Extended standby)
Dimensions (H×W×D)355 × 255 × 100 mm
WeightAnalyzer: 0.8 kg
Digestion Unit3.2 kg
Operating Environment0–50 °C, 10–85% RH
Protection RatingIP43
Light SourceMulti-channel cold LED array
CalibrationDual-mode (Photometric + Electrochemical)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelSH-6S
Digestion MethodReflux Digestion
Heating ModuleIntegrated Aluminum Block with Forced Air & Optional Water Cooling
Batch Capacity6 samples
Temperature RangeAmbient to 200 °C
Temperature Accuracy±1 °C
Digestion Vessel Volume250 mL
Timer Resolution0.1 s
Power Rating3000 W (AC 220 V ±10%, 50 Hz)
Net Weight32 kg
Display7-inch TFT Touchscreen (Chinese UI)
Sample IndependencePer-channel individual temperature & timer control
Cooling ModeDual-mode (fan-cooled standard
AlarmAudible end-of-digestion alert with automatic heating cutoff
Measuring Range4–700 mg/L COD (direct)
Digestion Time Setting1–999 min (user-programmable)
Precision≤5.0% RSD for 500 mg/L potassium hydrogen phthalate standard
Operating Ambient−5 °C to 45 °C
Fan ControlAuto/Manual mode selection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelSH-9008 (V11)
Instrument TypePortable
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Detectable MetalsCu, Pb, Cd, Zn, Hg, As(III)
Analysis Time≤3 min per sample
Accuracy≤±3%
Resolution0.01 ppb
Measurement Range (Zn)0.5 ppb–40 ppm
Measurement Range (Pb)0.5 ppb–50 ppm
Measurement Range (Cd)0.1 ppb–40 ppm
Measurement Range (Cu)0.1 ppb–30 ppm
Measurement Range (Hg)0.1 ppb–6 ppm
Measurement Range (As(III))1 ppb–20 ppm
Repeatability (RSD)≤5%
Operating Temperature0–50 °C
Relative Humidity10–90% RH
Power SupplyInternal Li-ion battery + 12 V DC adapter
Dimensions (L×W×H)220 × 110 × 40 mm
Net Weight4.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelSH-10
Instrument CategoryLaboratory Benchtop Unit
Measurement Range0.01–100 mg/L
Accuracy≤ ±5%
Detection Limit0.01 mg/L
Distillation TimeUser-Programmable
Batch Capacity3 Samples per Run
Temperature Control RangeAmbient to 400 °C
Power Rating0–1500 W
Dimensions320 × 285 × 110 mm
Interference RemovalEffective against color, turbidity, suspended solids, heavy metals, and organic matrix interference
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelSH-6V10
Instrument TypePortable
Measurement PrincipleFluorescence Quenching
Range0–20 mg/L
Accuracy±3% FS
Repeatability±5% FS
Detection Limit0.01 mg/L
Temperature Range0–60 °C
Temperature Compensation Accuracy±0.5 °C
Resolution0.1 °C
Dimensions (H×W×D)200 × 100 × 35 mm
Power SupplyRechargeable Lithium-ion Battery
Electrode TypeDigital Fluorescent Sensor (No Membrane, No Electrolyte, Zero Polarization Time)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelSH-16A
Digestion MethodRapid Digestion
Heating ModuleSingle Aluminum Heating Block
Batch Capacity16 samples
Temperature RangeAmbient to 185 °C
Temperature Accuracy±0.5 °C
Digestion Vessel Capacity16 × standard COD tubes (16 mm OD)
Timer Accuracy±0.1 s
Power SupplyAC 220 V ±20%
Rated Power400 W
Net Weight2.7 kg
Housing MaterialImported high-transparency PP engineering plastic
Safety FeaturesMagnetic lid latch, overvoltage/surge protection, adaptive thermal load compensation, delayed thermal cutoff
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Benchtop Meter
Measurement PrincipleElectrochemical Galvanic Cell Probe
Range0–20 mg/L
Accuracy±0.3 mg/L
Repeatability0.05% RSD
Detection Limit0.01 mg/L
Temperature Compensation0.0–40.0 °C (Automatic)
Temperature Range0–40 °C
Saturation Range0–199%
Resolution0.01 mg/L
Temp. Accuracy±0.5 °C
Stability±0.10 mg/L over 3 h
Display4.3-inch TFT LCD
Power SupplyAC 220 V
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengAohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable
Detection PrincipleICP-OES (Inductively Coupled Plasma – Optical Emission Spectrometry)
Target ElementsMulti-element (37 elements from Si to Bi, customizable)
Analysis Time≤5 min per sample
Accuracy/Precision±8% RSD
Resolution5 ppm
DetectorSi-PIN Semiconductor Detector
X-ray Source45 kV / 200 µA Ag-anode End-window Microfocus X-ray Tube
Element RangeZ = 14 (Si) to 92 (U)
Sample FormSolid & Powder
Operating Temperature−20 °C to +60 °C
Relative Humidity≤90% RH (non-condensing)
Weight≤1.7 kg (with battery)
Power SupplyRechargeable Li-ion, 7.2 V / 6800 mAh, >8 h continuous operation
ConnectivityWi-Fi, Bluetooth v5.0, Email export, Cloud sync
Safety ComplianceComplies with IEC 62471 (LED/X-ray safety), EN 61000-6-3 (EMC), and incorporates automatic beam shutdown, real-time radiation monitoring, and interlocked test window
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelSH-12PLUS
Digestion MethodReflux Digestion
Heating ModuleIntegrated Aluminum Block with Independent Zone Control
Batch Capacity12 samples
Temperature RangeAmbient to 200 °C
Temperature Accuracy±1 °C
Digestion Vessel Volume250 mL
Timer Resolution0.1 s
Power Rating3000 W (AC 220 V ±10%, 50 Hz)
Display7-inch Capacitive Touchscreen (Chinese UI)
Cooling ModeDual-mode — Air-cooled (forced convection, sealed high-flow fan) or Optional Water-cooled Condensation
Alarm FunctionAudible End-of-Digestion Alert with Automatic Heater Shutdown
Weight32 kg
Environmental Operating Range−5 °C to 45 °C
COD Measurement Range4–700 mg/L (direct)
Digestion Time Setting1–999 min (user-programmable)
Fan ControlAuto/Manual Switching
PrecisionRSD ≤5.0% for KHP standard (500 mg/L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
Model6B-9
Digestion MethodRapid Digestion
Heating ModuleSingle Aluminum Block Heater
Batch Capacity9 samples
Temperature RangeAmbient to 200 °C
Temperature Accuracy±0.5 °C
Digestion Vessel Volume17 mL
Timer Accuracy±0.1 s at 10 min
Temperature Control Precision±1 °C at 165 °C
Timer Range1–199 min
Power SupplyAC 220 V ±10%, 50 Hz, 460 W
Dimensions (L×W×H)300 × 240 × 220 mm
Net Weight5.8 kg
Housing MaterialMolded High-Temperature Corrosion-Resistant Polymer
DisplayFull-Text Chinese Blue LCD Screen
Predefined Digestion Programs6 standard curves (COD, Total Phosphorus, Total Nitrogen, Total Copper, Hexavalent Chromium, etc.)
Safety ProtectionAutomatic thermal cutoff upon overtemperature
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengAohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (PRC)
Model6B-60Ag(V10)
Price RangeUSD 1,400–7,000
Instrument TypeBenchtop Laboratory Photometer
Detection PrincipleAbsorption Photometry (Visible Spectrophotometry at Fixed Wavelength)
Target AnalyteSilver Ion (Ag⁺)
Analysis Time per Sample≤30 min
Accuracy±8% of Full Scale (FS)
Resolution0.1 mg/L
Measurement Range0–1 mg/L
Optical Stability≤±0.001 A / 20 min
Light SourceLong-Life Cold LED (100,000 h nominal lifetime)
Data Storage Capacity5,000,000 records
Sample Throughput6 samples/batch
Operating Ambient Humidity<85% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz
Net Weight2.5 kg
Dimensions (W×D×H)360 × 280 × 150 mm
Rated Power15 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelSH-12C (V11)
Digestion MethodReflux Digestion
Heating ModuleSingle Aluminum Block Heater
Batch Capacity12 samples
Temperature RangeAmbient to 200 °C
Temperature Accuracy±1 °C
Digestion Vessel Capacity250 mL
Timer Accuracy±1 s
Power Consumption≤880 W
VoltageAC 220 V ±10%, 50 Hz
Dimensions355 × 320 × 110 mm
Operating Ambient Temperature5–40 °C
Ramp Time to Setpoint≤15 min
Uniformity Across Wells±0.2 °C
COD Measurement Range5–1000 mg/L (direct), up to 10,000 mg/L with dilution
Total Digestion Time≤150 min
Auto-ShutdownYes, after preset timer expiration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengaohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable
Measurement PrinciplePotassium Dichromate Digestion + Spectrophotometry
Wavelength Range400–750 nm
COD Range5–12,000 mg/L (multi-range)
Accuracy≤ ±5%
Repeatability≤ ±5%
LOD (COD)0.1 mg/L
Digestion & Analysis Time10–30 min
Batch Capacity12 samples per run
Data Storage5 million records
Calibration Curves119 preloaded
Chloride Interference ToleranceCl⁻ < 1200 mg/L (standard), up to 4000 mg/L (with correction)
Digestion Temp165 °C or 123 °C ±0.5 °C
Power SupplyAC 220 V ±10%, 50 Hz (adapter) / DC 24 V (rechargeable battery)
Dimensions440 × 350 × 190 mm
Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShengAohua
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelSH-6G
Price RangeUSD 700–1,400 (FOB)
Digestion MethodReflux Digestion
Heating ModuleSingle Aluminum Alloy Heating Block
Batch Capacity6 Samples
Rated Heating Power1500 W
Temperature Accuracy±1 °C
Sample Vessel Volume250 mL
Timer Resolution0.1 s
Cooling ModeDual-mode (Forced Air + Optional Water Circulation)
Compliance StandardHJ/T 70–2001 (China EPA Standard for COD Determination in High-Chloride Wastewater)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0