- All
- Favorite
- Popular
- Most rated
| Brand | ShengAohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Detection Principle | Photometry (Visible Light Absorption at Specific Wavelength) |
| Target Analyte | Nickel (Ni²⁺) |
| Measurement Range | 0–5 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ±8% of Full Scale |
| Analysis Time | 20–30 minutes per sample |
| Light Source | Cold LED with Narrow-Band Interference Filter (Lifetime ≥100,000 hours) |
| Optical Stability | ≤±0.005 A / 20 min |
| Sample Cell | Standard 10-mm Cuvette |
| Data Storage Capacity | Up to 5,000,000 records |
| Interface | USB 2.0 (Host/Device mode) |
| Printer Support | Integrated thermal printer |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 15 W |
| Dimensions (W×D×H) | 360 × 280 × 150 mm |
| Net Weight | 2.5 kg |
| Operating Humidity | <85% RH (non-condensing) |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SH-9008 (V11) |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Metals | Cu, Pb, Cd, Zn, Hg, As(III) |
| Analysis Time | ≤3 min per sample |
| Accuracy | ≤±3% |
| Resolution | 0.01 ppb |
| Measurement Range (Zn) | 0.5 ppb–40 ppm |
| Measurement Range (Pb) | 0.5 ppb–50 ppm |
| Measurement Range (Cd) | 0.1 ppb–40 ppm |
| Measurement Range (Cu) | 0.1 ppb–30 ppm |
| Measurement Range (Hg) | 0.1 ppb–6 ppm |
| Measurement Range (As(III)) | 1 ppb–20 ppm |
| Repeatability (RSD) | ≤5% |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–90% RH |
| Power Supply | Internal Li-ion battery + 12 V DC adapter |
| Dimensions (L×W×H) | 220 × 110 × 40 mm |
| Net Weight | 4.8 kg |
| Brand | ShengAohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Detection Principle | ICP-OES (Inductively Coupled Plasma – Optical Emission Spectrometry) |
| Target Elements | Multi-element (37 elements from Si to Bi, customizable) |
| Analysis Time | ≤5 min per sample |
| Accuracy/Precision | ±8% RSD |
| Resolution | 5 ppm |
| Detector | Si-PIN Semiconductor Detector |
| X-ray Source | 45 kV / 200 µA Ag-anode End-window Microfocus X-ray Tube |
| Element Range | Z = 14 (Si) to 92 (U) |
| Sample Form | Solid & Powder |
| Operating Temperature | −20 °C to +60 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Weight | ≤1.7 kg (with battery) |
| Power Supply | Rechargeable Li-ion, 7.2 V / 6800 mAh, >8 h continuous operation |
| Connectivity | Wi-Fi, Bluetooth v5.0, Email export, Cloud sync |
| Safety Compliance | Complies with IEC 62471 (LED/X-ray safety), EN 61000-6-3 (EMC), and incorporates automatic beam shutdown, real-time radiation monitoring, and interlocked test window |
| Brand | ShengAohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | 6B-60Ag(V10) |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Benchtop Laboratory Photometer |
| Detection Principle | Absorption Photometry (Visible Spectrophotometry at Fixed Wavelength) |
| Target Analyte | Silver Ion (Ag⁺) |
| Analysis Time per Sample | ≤30 min |
| Accuracy | ±8% of Full Scale (FS) |
| Resolution | 0.1 mg/L |
| Measurement Range | 0–1 mg/L |
| Optical Stability | ≤±0.001 A / 20 min |
| Light Source | Long-Life Cold LED (100,000 h nominal lifetime) |
| Data Storage Capacity | 5,000,000 records |
| Sample Throughput | 6 samples/batch |
| Operating Ambient Humidity | <85% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Net Weight | 2.5 kg |
| Dimensions (W×D×H) | 360 × 280 × 150 mm |
| Rated Power | 15 W |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | SH-1600A(V10) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Detection Principle | Photometric Method (Colorimetry) |
| Detectable Metals | Cu, Ni, Total Cr, Cr(VI), Fe, Zn, Ag (Multi-parameter) |
| Measurement Time | 30–40 min per sample |
| Accuracy/Precision | ≤ ±8% |
| Resolution | 0.001 mg/L |
| Display | 5-inch Full-touch Color LCD |
| Cuvette/Tube Compatibility | Dual-mode (Cuvette & Test Tube) |
| Light Source | Cold LED with Narrow-band Interference Filter (Lifespan ≥ 100,000 h) |
| Digestion Temperature Range | Room Temp to 200 °C (Adjustable & Saveable) |
| Curve Storage | 100 total curves (15 standard + 85 expandable) |
| Data Storage Capacity | 5 million records |
| Operating Humidity | ≤85% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 15 W |
| Net Weight | 2.5 kg |