Empowering Scientific Discovery

Jiebi Technology (Beijing) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
Model94710-4
Temperature Range-40 °C to +20 °C
Temperature Stability±0.01 °C
Test Positions2
Bath Volume7 L (oil)
Cooling SystemIntegrated refrigeration (reaches -40 °C in <4 h)
Safety FeaturesIndependent overtemperature and low-fluid-level cut-off
Viewing Window & Insulated Top PlatePrevents condensation
ComplianceASTM D445, ASTM D446, IP 71, BS 188, BS 2000-71-2, ISO 3105, BS EN ISO 3104, BS 2000-71.1, GB/T 265
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTAMSON
OriginNetherlands
ModelTV16000
Temperature Range10–60 °C
Temperature Stability±0.005 °C
Bath Volume160 L
Temperature Resolution0.001 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
ModelRPV-1
ComplianceASTM D789, ISO 307, ASTM D4603, ASTM D2857, ASTM D1795, SCAN CM15:99, TAPPI T230-om94, ASTM D1243, USP <911>, ISO 1628
Timing resolution0.001 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
Model84200-0
Temperature Stability±0.02°C up to 100°C, ±0.05°C from 100°C to 150°C
Temperature Uniformity±0.01°C at 40°C and 100°C
Bath Capacity50 L
Temperature RangeAmbient to 150°C
Display Resolution0.01°C
Dimensions56 × 35 × 44 cm
Power Consumption2.2 kW
Weight33 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
ModelD445
ComplianceASTM D445, ASTM D446, ASTM D1655, IP 71, ISO 3104, ISO 3105
Operating Temperatures–20 °C, 20 °C, 40 °C (user-selectable)
Sample Volume12 mL
Bath Volume2 L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRavenfield
OriginUnited Kingdom
ModelBS/C
ComplianceASTM D4741, SH/T 0618-95, IP 320, CEC L-36-A-90, SAE J300
Temperature Range60 °C to 180 °C
Shear Rate Range1 × 10⁵ s⁻¹ to 1.5 × 10⁶ s⁻¹
Measurement PrincipleCone-and-plate Couette flow (Ravensberg method)
OutputDynamic viscosity (mPa·s), torque (mN·m), temperature (°C)
InterfaceRS-232 serial port
Automation LevelFully automated with embedded microcontroller and guided workflow
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiolab
ModelViscol-10A
ApplicationFuel & Lubricant Testing
Temperature Control Points40 °C and 100 °C
Measurement PrincipleCapillary Flow Timing (ASTM D445 / ISO 3104)
Viscosity Index CalculationIntegrated
Automation LevelFully Automated (Measurement, Rinse, Calibration, Drain)
ComplianceASTM D445, ISO 3104, IP 71, GB/T 265
Temperature Stability±0.01 °C
Timing Resolution0.01 s
Sample CapacityUp to 6 positions (configurable)
Cleaning ProtocolSolvent-based automated rinse cycle
Data OutputCSV, PDF report with VI, kinematic viscosity (mm²/s), and instrument metadata
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
Model14020-8
Bath Quantity2
Cylinders per Bath2 (total 4 × 1000 mL)
Diffuser Material OptionsStainless Steel or Sintered Glass
Flowmeters2 per bath
Temperature RangeAmbient to 100 °C ±0.5 °C
Power Consumption3 kW
Dimensions (W×D×H)70 × 48 × 40 cm
Weight50 kg
ComplianceASTM D892, ISO 6247, IP 146, BS 2000-146, GB/T 12579, NF T60-129, JIS K2518, FTM 791-3211
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0