| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 94710-4 |
| Temperature Range | -40 °C to +20 °C |
| Temperature Stability | ±0.01 °C |
| Test Positions | 2 |
| Bath Volume | 7 L (oil) |
| Cooling System | Integrated refrigeration (reaches -40 °C in <4 h) |
| Safety Features | Independent overtemperature and low-fluid-level cut-off |
| Viewing Window & Insulated Top Plate | Prevents condensation |
| Compliance | ASTM D445, ASTM D446, IP 71, BS 188, BS 2000-71-2, ISO 3105, BS EN ISO 3104, BS 2000-71.1, GB/T 265 |
| Brand | TAMSON |
|---|---|
| Origin | Netherlands |
| Model | TV16000 |
| Temperature Range | 10–60 °C |
| Temperature Stability | ±0.005 °C |
| Bath Volume | 160 L |
| Temperature Resolution | 0.001 °C |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | RPV-1 |
| Compliance | ASTM D789, ISO 307, ASTM D4603, ASTM D2857, ASTM D1795, SCAN CM15:99, TAPPI T230-om94, ASTM D1243, USP <911>, ISO 1628 |
| Timing resolution | 0.001 s |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 84200-0 |
| Temperature Stability | ±0.02°C up to 100°C, ±0.05°C from 100°C to 150°C |
| Temperature Uniformity | ±0.01°C at 40°C and 100°C |
| Bath Capacity | 50 L |
| Temperature Range | Ambient to 150°C |
| Display Resolution | 0.01°C |
| Dimensions | 56 × 35 × 44 cm |
| Power Consumption | 2.2 kW |
| Weight | 33 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | D445 |
| Compliance | ASTM D445, ASTM D446, ASTM D1655, IP 71, ISO 3104, ISO 3105 |
| Operating Temperatures | –20 °C, 20 °C, 40 °C (user-selectable) |
| Sample Volume | 12 mL |
| Bath Volume | 2 L |
| Brand | Ravenfield |
|---|---|
| Origin | United Kingdom |
| Model | BS/C |
| Compliance | ASTM D4741, SH/T 0618-95, IP 320, CEC L-36-A-90, SAE J300 |
| Temperature Range | 60 °C to 180 °C |
| Shear Rate Range | 1 × 10⁵ s⁻¹ to 1.5 × 10⁶ s⁻¹ |
| Measurement Principle | Cone-and-plate Couette flow (Ravensberg method) |
| Output | Dynamic viscosity (mPa·s), torque (mN·m), temperature (°C) |
| Interface | RS-232 serial port |
| Automation Level | Fully automated with embedded microcontroller and guided workflow |
| Brand | Biolab |
|---|---|
| Model | Viscol-10A |
| Application | Fuel & Lubricant Testing |
| Temperature Control Points | 40 °C and 100 °C |
| Measurement Principle | Capillary Flow Timing (ASTM D445 / ISO 3104) |
| Viscosity Index Calculation | Integrated |
| Automation Level | Fully Automated (Measurement, Rinse, Calibration, Drain) |
| Compliance | ASTM D445, ISO 3104, IP 71, GB/T 265 |
| Temperature Stability | ±0.01 °C |
| Timing Resolution | 0.01 s |
| Sample Capacity | Up to 6 positions (configurable) |
| Cleaning Protocol | Solvent-based automated rinse cycle |
| Data Output | CSV, PDF report with VI, kinematic viscosity (mm²/s), and instrument metadata |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 14020-8 |
| Bath Quantity | 2 |
| Cylinders per Bath | 2 (total 4 × 1000 mL) |
| Diffuser Material Options | Stainless Steel or Sintered Glass |
| Flowmeters | 2 per bath |
| Temperature Range | Ambient to 100 °C ±0.5 °C |
| Power Consumption | 3 kW |
| Dimensions (W×D×H) | 70 × 48 × 40 cm |
| Weight | 50 kg |
| Compliance | ASTM D892, ISO 6247, IP 146, BS 2000-146, GB/T 12579, NF T60-129, JIS K2518, FTM 791-3211 |